Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
The DOI matches its Crossref record; 93 of the 93 references it cites were found in a registry or an index.
Abstract
Progress has recently been made in implementing magnetic resonance imaging (MRI) techniques that can be used to obtain images in a fraction of a second rather than in minutes. Echo-planar imaging (EPI) uses only one nuclear spin excitation per image and lends itself to a variety of critical medical and scientific applications. Among these are evaluation of cardiac function in real time, mapping of water diffusion and temperature in tissue, mapping of organ blood pool and perfusion, functional imaging of the central nervous system, depiction of blood and cerebrospinal fluid flow dynamics, and movie imaging of the mobile fetus in utero. Through shortened patient examination times, higher patient throughput, and lower cost per MRI examination, EPI may become a powerful tool for early diagnosis of some common and potentially treatable diseases such as ischemic heart disease, stroke, and cancer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Resonance Absorption by Nuclear Magnetic Moments in a Solid
Purcell, E. M., Torrey, H. C., & Pound, R. V. (1946) · Physical Review · doi:10.1103/physrev.69.37 · Cited by 6,053
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Self-citationTumor Detection by Nuclear Magnetic Resonance
Damadian, R. (1971) · Science · doi:10.1126/science.171.3976.1151 · Cited by 1,466
FLASH imaging: Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hänicke, W., & Merboldt, K.-D. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.021 · Cited by 1,153
Research works printed but not linked: 22
- Belliveau, J. W., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 202 (1991).
- Bourland, J. D., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 1157 (1990).
- Budinger, T. F., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 276 (1990).
- EHMAN, L.R., AM J ROENTGENOL 143: 1175 (1985).
- Fischer, H., 75th Annual Meeting of the Radiological Society of North America: 276 (1989).
- HENKELMAN, R.M., REV MAGN RESON MED 2: 1 (1987).
- Higuchi, N., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 638 (1990).
- Kose, K., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 168 (1990).
- KUMAR, A, NMR FOURIER ZEUGMATOGRAPHY, JOURNAL OF MAGNETIC RESONANCE 18: 69 (1975).
- MOONEN, CTW, RADIOLOGY 171: 853 (1989). · DOI · Paper page
- Ordidge, R. J., Eighth Annual Meeting of the Society of Magnetic Resonance in Medicine Book of Abstracts: 889 (1989).
- PATRONAS, N, NEURORADIOLOGY 33 Supplement: 267 (1991).
- RADON, J, BER VERH SACHS AK MN 69: 262 (1917).
- Roemer, P. B., Fifth Annual Meeting of the Society of Magnetic Resonance in Medicine Book of Abstracts: 1067 (1986).
- ROSEN, B.R., JOURNAL OF GEOLOGICAL EDUCATION 5: 263 (1989).
- Stehling M. K. American Journal of Roentgenology in press.
- Stehling M. K. Radiology in press.
- STEHLING, M.K., ECHO-PLANAR MAGNETIC-RESONANCE IMAGING IN ABNORMAL PREGNANCIES, LANCET 2: 157 (1989).
- STEHLING, M.K., 8TH ANN M SOC MAGN R: 50 (1990).
- Wedeen, V. J., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 164 (1990).
- White, D., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 57 (1990).
- Wilke N. Radiology in press.
Cited by
Items 101–200 of 729
(1994) · American Journal of Psychiatry · doi:10.1176/ajp.151.10.1493 · Cited by 75
Off‐resonance artifact correction for MRI: A review
Haskell, M. W., Nielsen, J., & Noll, D. C. (2022) · NMR in Biomedicine · doi:10.1002/nbm.4867 · Cited by 75
Single-Shot Gradient-Assisted Photon Echo Electronic Spectroscopy
Harel, E., Fidler, A. F., & Engel, G. S. (2010) · The Journal of Physical Chemistry A · doi:10.1021/jp107022f · Cited by 74
A practical and flexible implementation of 3D MRI in the Earth’s magnetic field
Halse, M. E., Coy, A., Dykstra, R., Eccles, C. D., Hunter, M. W., Ward, R., & Callaghan, P. T. (2006) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2006.06.011 · Cited by 74
High-resolution functional magnetic resonance imaging of the animal brain
Kim, S., & Uǧurbil, K. (2003) · Methods · doi:10.1016/s1046-2023(03)00005-7 · Cited by 71
New magnetic resonance techniques for evaluating cerebrovascular disease
Fisher, M., Sotak, C. H., Minematsu, K., & Li, L. (1992) · Annals of Neurology · doi:10.1002/ana.410320202 · Cited by 71
Anagnostara, A., Stoeckli, S. J., Weber, O. M., & Kollias, S. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1172 · Cited by 70
Dual dynamic contrast‐enhanced MR imaging
Miyati, T., Banno, T., Mase, M., Kasai, H., Shundo, H., Imazawa, M., & Ohba, S. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070136 · Cited by 69
Dyscalculia and Dyslexia After Right Hemisphere Injury in Infancy
Levin, H. S., Scheller, J., Rickard, T., Grafman, J., Martinkowski, K., Winslow, M., & Mirvis, S. (1996) · Archives of Neurology · doi:10.1001/archneur.1996.00550010108024 · Cited by 57
Imaging of acute stroke: CT and/or MRI
Lövblad, K., Altrichter, S., Pereira, V. M., Vargas, M. I., Gonzalez, A. M. D., Haller, S., & Sztajzel, R. F. (2014) · Journal of Neuroradiology · doi:10.1016/j.neurad.2014.10.005 · Cited by 68
Functional magnetic resonance imaging
Bullmore, E. T., & Suckling, J. (2001) · International Review of Psychiatry · doi:10.1080/09540260020024169 · Cited by 67
Chemical imaging of multicomponent viscous fingering in chromatography
Dickson, M. L., Norton, T. T., & Fernández, E. (1997) · AIChE Journal · doi:10.1002/aic.690430214 · Cited by 67
Referenceless interleaved echo-planar imaging
Reeder, S. B., Atalar, E., Faranesh, A. Z., & McVeigh, E. R. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199901)41:1<87::aid-mrm13>3.0.co;2-x · Cited by 66
Effects of low-field magnetic stimulation on brain glucose metabolism
Volkow, N. D., Tomasi, D., Wang, G.-J., Fowler, J. S., Telang, F., Wang, R., Alexoff, D., Logan, J., Wong, C., Pradhan, K., et al. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.02.015 · Cited by 56
In Vivo Relaxation Time Measurements in the Human Placenta Using Echo Planar Imaging at 0.5 T
Gowland, P. A., Freeman, A., Issa, B. A., Boulby, P. A., Duncan, K. R., Moore, R. J., Baker, P. N., Bowtell, R. W., Johnson, I. R., & Worthington, B. S. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(97)00308-1 · Cited by 65
Paulesu, E., Connelly, A., Frith, C. D., Friston, K. J., Heather, J., Myers, R., Gadian, D. G., & Frackowiak, R. S. J. (1995) · Neuroimaging Clinics of North America · doi:10.1016/s1052-5149(25)00291-6 · Cited by 56
Magnetic Resonance Imaging to Visualize Stroke and Characterize Stroke Recovery: A Review
MacIntosh, B. J., & Graham, S. J. (2013) · Frontiers in Neurology · doi:10.3389/fneur.2013.00060 · Cited by 64
Statistical methods for detecting activated regions in functional MRI of the brain
Ardekani, B. A., & Kanno, I. (1998) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(98)00125-8 · Cited by 64
Hampel, U., Babout, L., Banasiak, R., Schleicher, E., Soleimani, M., Wondrak, T., Vauhkonen, M. J., Lähivaara, T., Tan, C., Hoyle, B., et al. (2022) · Sensors · doi:10.3390/s22062309 · Cited by 63
Improving resolution in single-scan 2D spectroscopy
Pelupessy, P., Duma, L., & Bodenhausen, G. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.06.023 · Cited by 63
The Benefit of Slice Timing Correction in Common fMRI Preprocessing Pipelines
Parker, D. B., & Razlighi, Q. R. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00821 · Cited by 63
Real‐Time Monitoring of Organic Reactions with Two‐Dimensional Ultrafast TOCSY NMR Spectroscopy
Herrera, A., Fernández-Valle, M. E., Martínez‐Álvarez, R., Molero, D., Pardo, Z. D., Sáez, E., & Gal, M. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200902387 · Cited by 61
Ultrafast Brain MRI: Clinical Deployment and Comparison to Conventional Brain MRI at 3T
Prakkamakul, S., Witzel, T., Huang, S. Y., Boulter, D. J., Borja, M. J., Schaefer, P. W., Rosen, B. R., Heberlein, K., Ratai, E., González, R. G., et al. (2016) · Journal of Neuroimaging · doi:10.1111/jon.12365 · Cited by 61
Echo‐planar MR imaging of human brain oxygenation changes
Stehling, M. K., Schmitt, F., & Ladebeck, R. (1993) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880030307 · Cited by 59
Self-citationApplications of magnetic resonance imaging to the study of human brain function
Bihan, D. L., & Karni, A. (1995) · Current Opinion in Neurobiology · doi:10.1016/0959-4388(95)80031-x · Cited by 59
Optimal slice timing correction and its interaction with fMRI parameters and artifacts
Parker, D., Liu, X., & Razlighi, Q. R. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.08.006 · Cited by 58
Reconstruction techniques for cardiac cine MRI
Menchón-Lara, R.-M., Simmross‐Wattenberg, F., Casaseca‐de‐la‐Higuera, P., Martín‐Fernández, M., & Alberola‐López, C. (2019) · Insights into Imaging · doi:10.1186/s13244-019-0754-2 · Cited by 58
Perfusion imaging of the human brain at 1.5 T using a single‐shot EPI spin tagging approach
Ye, F. Q., Pekar, J. J., Jezzard, P., Duyn, J. H., Frank, J. A., & McLaughlin, A. C. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360208 · Cited by 58
Clinical Neuroimaging in Psychiatry
Rauch, S. L., & Renshaw, P. F. (1995) · Harvard Review of Psychiatry · doi:10.3109/10673229509017151 · Cited by 52
Solomon, E., Avni, R., Hadas, R., Raz, T., Garbow, J. R., Bendel, P., Frydman, L., & Neeman, M. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1401695111 · Cited by 57
Real-Time Magnetic Resonance Imaging of Bubble Behavior and Particle Velocity in Fluidized Beds
Penn, A., Boyce, C. M., Kovar, T. M., Tsuji, T., Pruessmann, K. P., & Müller, C. R. (2018) · Industrial & Engineering Chemistry Research · doi:10.1021/acs.iecr.8b00932 · Cited by 57
The inversion effect in visual word form processing
Kao, C., Chen, D.-Y., & Chen, C. (2009) · Cortex · doi:10.1016/j.cortex.2009.04.003 · Cited by 57
Spatial and temporal resolution of functional magnetic resonance imaging
Menon, R. S., Gati, J. S., Goodyear, B. G., Luknowsky, D. C., & Thomas, C. G. (1998) · Biochemistry and Cell Biology · doi:10.1139/bcb-76-2-3-560 · Cited by 56
Cortical Responses to Single Mechanoreceptive Afferent Microstimulation Revealed with fMRI
Trulsson, M., Francis, S., Kelly, E. F., Westling, G., Bowtell, R. W., & McGlone, F. P. (2001) · NeuroImage · doi:10.1006/nimg.2000.0723 · Cited by 55
Exploring the sensitivity of magnetic resonance fingerprinting to motion
Yu, Z., Zhao, T., Assländer, J., Lattanzi, R., Sodickson, D. K., & Cloos, M. A. (2018) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2018.09.002 · Cited by 53
Magnetic Resonance Imaging of Human Brain Function
Bandettini, P. A., & Wong, E. C. (1997) · Neurosurgery Clinics of North America · doi:10.1016/s1042-3680(18)30309-7 · Cited by 53
Nonaxial whole‐body instant imaging
Weisskoff, R. M., Cohen, M. S., & Rzedzian, R. R. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290612 · Cited by 53
Evolving Toward Effective Therapy for Acute Ischemic Stroke
Fisher, M., & Bogousslavsky, J. (1993) · JAMA · doi:10.1001/jama.1993.03510030084039 · Cited by 53
Furber, A., Balzer, P., Cavaro‐Ménard, C., Croué, A., Costa, E. D., Lethimonnier, F., Geslin, P., Tadéi, A., JALLET, P., & Jeune, J. L. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080503 · Cited by 52
A simple noise correction scheme for diffusional kurtosis imaging
Glenn, G. R., Tabesh, A., & Jensen, J. H. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.08.028 · Cited by 43
Rubin, D. A., & Kneeland, J. B. (1994) · American Journal of Roentgenology · doi:10.2214/ajr.163.5.7976893 · Cited by 51
Cauley, S., Setsompop, K., Bilgiç, B., Bhat, H., Gagoski, B. A., & Wald, L. L. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26499 · Cited by 50
Evaluating phase synchronization methods in fMRI: A comparison study and new approaches
Honari, H., Choe, A. S., & Lindquist, M. A. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117704 · Cited by 51
Principles and implementation of diffusion-weighted and diffusion tensor imaging
Roberts, T. P. L., & Schwartz, E. S. (2007) · Pediatric Radiology · doi:10.1007/s00247-007-0516-z · Cited by 50
The Temporal Resolution of Functional MRI
Bandettini, P. A. (2000) · Medical radiology · doi:10.1007/978-3-642-58716-0_19 · Cited by 50
Cognitive stimulation with the Wisconsin Card Sorting Test: functional MR imaging at 1.5 T.
Mentzel, H. J., Gaser, C., Volz, H. P., Rzanny, R., Häger, F., Sauer, H., & Kaiser, W. A. (1998) · Radiology · doi:10.1148/radiology.207.2.9577487 · Cited by 49
Magnetic Resonance Imaging for Quality Evaluation of Fruits: a Review
Srivastava, R. K., Talluri, S., Shaik, K. B., & Kumar, B. R. (2018) · Food Analytical Methods · doi:10.1007/s12161-018-1262-6 · Cited by 49
Cerebral changes in hepatic encephalopathy
Watanabe, A. (1998) · Journal of Gastroenterology and Hepatology · doi:10.1111/j.1440-1746.1998.tb00728.x · Cited by 49
Diffusion-weighted MR Imaging of the Kidneys and the Urinary Tract
Kim, S., Naik, M., Sigmund, E. E., & Taouli, B. A. (2008) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2008.07.006 · Cited by 48
Sutherland, G. R., Kaibara, T., Wallace, C. J., Tomanek, B., & Richter, M. C. (2002) · Neurosurgery · doi:10.1097/00006123-200204000-00044 · Cited by 48
Functional Study of the Brain by NMR
Prichard, J. W., & Rosen, B. R. (1994) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1994.47 · Cited by 44
Pitfalls in 16–Detector Row CT of the Coronary Arteries
Nakanishi, T., Kayashima, Y., Inoue, R., Sumii, K., & Gomyo, Y. (2005) · Radiographics · doi:10.1148/rg.252045098 · Cited by 45
Wielopolski, P. A., van Geuns, R., de Feyter, P. J., & Oudkerk, M. (1998) · European Radiology · doi:10.1007/s003300050484 · Cited by 45
Harel, E., Schröder, L., & Xu, S. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113018 · Cited by 44
Dietrich, O., Heiland, S., Benner, T., & Sartor, K. J. (2000) · Neuroradiology · doi:10.1007/s002340050020 · Cited by 44
Yang, J.-C. (2004) · Korean Journal of Radiology · doi:10.3348/kjr.2004.5.2.87 · Cited by 40
Pharmacological MRI in animal models: A useful tool for 5-HT research?
Martin, C. J., & Sibson, N. R. (2008) · Neuropharmacology · doi:10.1016/j.neuropharm.2008.08.014 · Cited by 42
Peripheral Nerve Stimulation by Time-Varying Magnetic Fields
Abart, J., Eberhardt, K., Fischer, H., Huk, W. J., Richter, E., Schmitt, Storch, T., & Zeitler, E. (1997) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199707000-00005 · Cited by 42
Imaging neuronal development with magnetic resonance imaging (NMR) microscopy
Jacobs, R. E., & Fraser, S. E. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90192-9 · Cited by 41
David, A. S., Blamire, A. M., & Breiter, H. (1994) · The British Journal of Psychiatry · doi:10.1192/bjp.164.1.2 · Cited by 41
Learning Optimal K-space Acquisition and Reconstruction using Physics-Informed Neural Networks
Peng, W., Feng, L., Zhao, G., & Liu, F. (2022) · IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings - IEEE Computer Society Conference on Computer Vision and Pattern Recognition/Proceedings · doi:10.1109/cvpr52688.2022.02013 · Cited by 40
Compressed Sensing MRI via Two-stage Reconstruction
Yang, Y., Liu, F., Xu, W., & Crozier, . (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2341621 · Cited by 40
Spatial mapping of velocity power spectra in Taylor-Couette flow using ultrafast NMR imaging
Kose, K. (1994) · Physical Review Letters · doi:10.1103/physrevlett.72.1467 · Cited by 40
Schubert, G. A., Poli, S., Schilling, L., Heiland, S., & Thomé, C. (2008) · Journal of Neurotrauma · doi:10.1089/neu.2007.0443 · Cited by 39
Farjadian, F., Moradi, S., & Hosseini, M. H. (2017) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-017-5854-2 · Cited by 39
A Brief Review on: MRI Images Reconstruction using GAN
Shende, P., Pawar, M., & Kakde, S. (2019) · International Conference on Communications and Signal Processing (ICCSP) · doi:10.1109/iccsp.2019.8698083 · Cited by 39
Advancements in Gradient System Performance for Clinical and Research MRI
Gudino, N., & Littin, S. (2022) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.28421 · Cited by 39
A review on statistical noise models for Magnetic Resonance Imaging 1
Aja‐Fernández, S., & Trist, A. (2013) · Cited by 39
Hyperelastic Susceptibility Artifact Correction of DTI in SPM
Ruthotto, L., Mohammadi, S., Heck, C., Modersitzki, J., & Weiskopf, N. (2013) · Informatik aktuell · doi:10.1007/978-3-642-36480-8_60 · Cited by 39
CHEMICAL AND PHYSIOLOGIC BRAIN IMAGING IN SCHIZOPHRENIA
McClure, R. J., Keshavan, M. S., & Pettegrew, J. W. (1998) · Psychiatric Clinics of North America · doi:10.1016/s0193-953x(05)70363-4 · Cited by 39
Diffusion weighted imaging for acute cerebral infarction
Schäbitz, W.-R., & Fisher, M. (1995) · Neurological Research · doi:10.1080/01616412.1995.11740325 · Cited by 39
Diffusion weighted MRI by spatiotemporal encoding: Analytical description and in vivo validations
Solomon, E., Shemesh, N., & Frydman, L. (2013) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2013.02.014 · Cited by 38
Lundin, B., Cooper, T. G., Meyer, R. A., & Potchen, E. J. (1993) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(93)90411-6 · Cited by 38
Simon, N. G., Talbott, J. F., Chin, C. T., & Kliot, M. (2016) · Handbook of clinical neurology · doi:10.1016/b978-0-444-53486-6.00040-5 · Cited by 37
Huh, J., Park, K., Hwang, I. S., Jung, S. I., Kim, H.-J., Chung, T. W., & Jeong, G. (2008) · The Journal of Sexual Medicine · doi:10.1111/j.1743-6109.2007.00717.x · Cited by 37
Spectrally resolved flow imaging of fluids inside a microfluidic chip with ultrahigh time resolution
Harel, E., & Pines, A. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.04.037 · Cited by 37
Comparison of echo-planar sequences for perfusion-weighted MRI: which is best?
Heiland, S., Kreibich, W., Reith, W., Benner, T., Dörfler, A., Forsting, M., & Sartor, K. J. (1998) · Neuroradiology · doi:10.1007/s002340050570 · Cited by 37
Real-time magnetic resonance imaging of fluidized beds with internals
Penn, A., Boyce, C. M., Conzelmann, N. A., Bezinge, G., Pruessmann, K. P., & Müller, C. R. (2019) · Chemical Engineering Science · doi:10.1016/j.ces.2018.12.041 · Cited by 36
Prospective motion correction of segmented diffusion weighted EPI
Herbst, M., Zahneisen, B., Knowles, B. R., Zaitsev, M., & Ernst, T. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25547 · Cited by 36
Two-step navigatorless correction algorithm for radialk-space MRI acquisitions
Shankaranarayanan, A., Wendt, M., Lewin, J. S., & Duerk, J. L. (2001) · Magnetic Resonance in Medicine · doi:10.1002/1522-2594(200102)45:2<277::aid-mrm1037>3.0.co;2-1 · Cited by 36
BlochLib: a fast NMR C++ tool kit
Blanton, W. B. (2003) · Journal of Magnetic Resonance · doi:10.1016/s1090-7807(03)00035-1 · Cited by 36
Phase-locking of resting-state brain networks with the gastric basal electrical rhythm
Choe, A. S., Tang, B., Smith, K., Honari, H., Lindquist, M. A., Caffo, B. S., & Pekar, J. J. (2021) · PLoS ONE · doi:10.1371/journal.pone.0244756 · Cited by 35
Magnetic resonance imaging of single bubbles injected into incipiently fluidized beds
Boyce, C. M., Penn, A., Lehnert, M., Pruessmann, K. P., & Müller, C. R. (2019) · Chemical Engineering Science · doi:10.1016/j.ces.2019.01.047 · Cited by 35
Mishkovsky, M., Eliav, U., Navon, G., & Frydman, L. (2009) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.06.002 · Cited by 34
Magnetic resonance imaging of gas–solid fluidization with liquid bridging
Boyce, C. M., Penn, A., Pruessmann, K. P., & Müller, C. R. (2017) · AIChE Journal · doi:10.1002/aic.16036 · Cited by 34
A 16-channel AC/DC array coil for anesthetized monkey whole-brain imaging at 7T
Gao, Y., Mareyam, A., Sun, Y., Witzel, T., Arango, N. S., Kuang, I., White, J., Roe, A. W., Wald, L. L., Stockmann, J., et al. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.116396 · Cited by 34
Signal Sources in Bold Contrast FMRI
Turner, R. (1997) · Advances in experimental medicine and biology · doi:10.1007/978-1-4899-0056-2_2 · Cited by 34
Self-citationFast magnetic resonance imaging of the heart
Sakuma, H., Takeda, K., & Higgins, C. B. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(98)00173-9 · Cited by 34
Autry, A. W., Gordon, J. W., Carvajal, L. E., Mareyam, A., Chen, H., Park, I., Mammoli, D., Vareth, M., Chang, S. M., Wald, L. L., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27743 · Cited by 33
Kawamura, M., Tamada, D., Funayama, S., Kromrey, M., Ichikawa, S., Onishi, H., & Motosugi, U. (2020) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.tn.2019-0081 · Cited by 33
Hodge, C. J., Huckins, S. C., Szeverenyi, N. M., Fonte, M. M., Dubroff, J. G., & Davuluri, K. (1998) · Journal of neurosurgery · doi:10.3171/jns.1998.89.5.0769 · Cited by 33
Magnetic resonance imaging of brain function
Turner, R. (1994) · Annals of Neurology · doi:10.1002/ana.410350602 · Cited by 32
Self-citationGilbert, R., Daftary, S., Campbell, T. A., & Weisskoff, R. M. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080307 · Cited by 32
Müller, R. (1992) · Aphasiology · doi:10.1080/02687039208249484 · Cited by 32
Non-Cartesian MRI scan time reduction through sparse sampling
Wajer, F. T. A. W. (2001) · Research Repository (Delft University of Technology) · Cited by 32
Penn, A., Boyce, C. M., Pruessmann, K. P., & Müller, C. R. (2019) · Chemical Engineering Journal · doi:10.1016/j.cej.2019.123185 · Cited by 31
In vivo structural analysis of articular cartilage using diffusion tensor magnetic resonance imaging
Azuma, T., Nakai, R., Takizawa, O., & Tsutsumi, S. (2009) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2009.05.012 · Cited by 31
Clinical applications of functional MRI in neuropsychiatry
Levin, J. M., Ross, M. H., & Renshaw, P. F. (1995) · Journal of Neuropsychiatry · doi:10.1176/jnp.7.4.511 · Cited by 31
Topical Review: Functional Brain Imaging in Neuropsychiatric Disorders of Childhood
O’Tuama, L. A., Dickstein, D. P., Neeper, R., & Gascon, G. G. (1999) · Journal of Child Neurology · doi:10.1177/088307389901400401 · Cited by 31
Zhang, Z., Chen, H., Wu, C., Wu, R., Cai, S., & Chen, Z. (2012) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.020 · Cited by 30
Metadata
- Authors
- Stehling, M. K., Turner, R., & Mansfield, P.
- Affiliations
- Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
- Venue
- Science
- Published
- 1991-10-04
- Volume
- 254
- Issue
- 5028
- Pages
- 43-50
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1991844483
- Cited by
- 623
- References
- 93
- Citations by year
- 2026: 11 · 2025: 18 · 2024: 11 · 2023: 18 · 2022: 21 · 2021: 22 · 2020: 25 · 2019: 29 · 2018: 19 · 2017: 23 · 2016: 23 · 2015: 21 · 2014: 18 · 2013: 18 · 2012: 8
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- Max Planck Digital Library (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- echo planar imaging, rapid MRI, cardiac function imaging, temperature mapping, blood pool imaging, perfusion imaging, functional MRI, cerebrospinal fluid flow, fetal MRI, ischemic heart disease, stroke, cancer diagnosis
- MeSH terms
- Diffusion, Humans, Magnetic Resonance Imaging, Motion, Regional Blood Flow, Time Factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.