The DOI matches its Crossref record; 93 of the 93 references it cites were found in a registry or an index.
Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
Abstract
Progress has recently been made in implementing magnetic resonance imaging (MRI) techniques that can be used to obtain images in a fraction of a second rather than in minutes. Echo-planar imaging (EPI) uses only one nuclear spin excitation per image and lends itself to a variety of critical medical and scientific applications. Among these are evaluation of cardiac function in real time, mapping of water diffusion and temperature in tissue, mapping of organ blood pool and perfusion, functional imaging of the central nervous system, depiction of blood and cerebrospinal fluid flow dynamics, and movie imaging of the mobile fetus in utero. Through shortened patient examination times, higher patient throughput, and lower cost per MRI examination, EPI may become a powerful tool for early diagnosis of some common and potentially treatable diseases such as ischemic heart disease, stroke, and cancer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Resonance Absorption by Nuclear Magnetic Moments in a Solid
Purcell, E. M., Torrey, H. C., & Pound, R. V. (1946) · Physical Review · doi:10.1103/physrev.69.37 · Cited by 6,053
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Self-citationTumor Detection by Nuclear Magnetic Resonance
Damadian, R. (1971) · Science · doi:10.1126/science.171.3976.1151 · Cited by 1,466
FLASH imaging: Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hänicke, W., & Merboldt, K.-D. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.021 · Cited by 1,153
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151
Diffusion-weighted MR imaging of anisotropic water diffusion in cat central nervous system.
Moseley, M. E., Cohen, Y., Kucharczyk, J., Mintorovitch, J., Asgari, H. S., Wendland, M. F., Tsuruda, J., & Norman, D. (1990) · Radiology · doi:10.1148/radiology.176.2.2367658 · Cited by 1,133
(2024) · American Journal of Neuroradiology · doi:10.3174/ajnr.45-12.s8 · Cited by 890
Bloch, F., Hansen, W. W., & Packard, M. (1946) · Physical Review · doi:10.1103/physrev.69.127 · Cited by 883
Spin warp NMR imaging and applications to human whole-body imaging
Edelstein, W. A., Hutchison, J. M. S., Johnson, G., & Redpath, T. (1980) · Physics in Medicine & Biology · doi:10.1088/0031-9155/25/4/017 · Cited by 803
Snapshot flash mri. applications to t1, t2, and chemical‐shift imaging
Haase, A. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130109 · Cited by 693
Echo-planar imaging of intravoxel incoherent motion.
Turner, R., Le Bihan, D., Maier, J., Vavrek, R., Hedges, L. K., & Pekar, J. (1990) · Radiology · doi:10.1148/radiology.177.2.2217777 · Cited by 581
Self-citationMansfield, P., & Grannell, P. K. (1973) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/6/22/007 · Cited by 551
Self-citationMeasurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference Technique
Bryant, D. J., Payne, J. A., Firmin, D. N., & Longmore, D. B. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198408000-00002 · Cited by 545
Anisotropic diffusion in human white matter: demonstration with MR techniques in vivo.
Chenevert, T. L., Brunberg, J. A., & Pipe, J. G. (1990) · Radiology · doi:10.1148/radiology.177.2.2217776 · Cited by 503
Temperature mapping with MR imaging of molecular diffusion: application to hyperthermia.
Le Bihan, D., Delannoy, J., & Levin, R. L. (1989) · Radiology · doi:10.1148/radiology.171.3.2717764 · Cited by 493
High-Speed Spiral-Scan Echo Planar NMR Imaging-I
Ahn, C. B., Kim, J. H., & Cho, Z. H. (1986) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1986.4307732 · Cited by 487
Clinical magnetic resonance imaging
Edelman, R. R., Hesselink, J. R., & Zlatkin, M. B. (1990) · Saunders eBooks · Cited by 420
Human brain motion and cerebrospinal fluid circulation demonstrated with MR velocity imaging.
Feinberg, D. A., & Mark, A. S. (1987) · Radiology · doi:10.1148/radiology.163.3.3575734 · Cited by 379
Twieg, D. B. (1983) · Medical Physics · doi:10.1118/1.595331 · Cited by 373
Blood flow effects in magnetic resonance imaging
Axel, L. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.143.6.1157 · Cited by 327
Bailes, D. R., Gilderdale, D. J., Bydder, G. M., Collins, A. G., & Firmin, D. N. (1985) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198507010-00039 · Cited by 313
MR image artifacts from periodic motion
Wood, M. L., & Henkelman, R. M. (1985) · Medical Physics · doi:10.1118/1.595782 · Cited by 302
Bailes, D. R., Gilderdale, D. J., Bydder, G. M., et al. (1985) · PubMed · Cited by 300
Magnetic resonance imaging with respiratory gating: techniques and advantages
Ehman, R., McNamara, M., Pallack, M., Hricak, H., & Higgins, C. (1984) · American Journal of Roentgenology · doi:10.2214/ajr.143.6.1175 · Cited by 299
Peripheral nerve stimulation by induced electric currents: Exposure to time-varying magnetic fields
Reilly, J. P. (1989) · Medical & Biological Engineering & Computing · doi:10.1007/bf02446217 · Cited by 293
A simple graphical representation of fourier-based imaging methods
Ljunggren, S. (1983) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(83)90060-4 · Cited by 292
Image formation in NMR by a selective irradiative process
Garroway, A. N., Grannell, P. K., & Mansfield, P. (1974) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/7/24/006 · Cited by 271
Self-citation"Diffraction" and microscopy in solids and liquids by NMR
Mansfield, P., & Grannell, P. K. (1975) · Physical Review B · doi:10.1103/physrevb.12.3618 · Cited by 266
Self-citationBlood Flow Rates by Nuclear Magnetic Resonance Measurements
Singer, J. R. (1959) · Science · doi:10.1126/science.130.3389.1652 · Cited by 248
Flowing cerebrospinal fluid in normal and hydrocephalic states: appearance on MR images.
Bradley, W. G., Kortman, K. E., & Burgoyne, B. (1986) · Radiology · doi:10.1148/radiology.159.3.3704142 · Cited by 236
Motion Artifact Suppression Technique (MAST) for MR Imaging
Pattany, P. M., Phillips, J. J., Chiu, L. C., Lipcamon, J. D., Duerk, J. L., McNally, J. M., & Mohapatra, S. N. (1987) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198705000-00001 · Cited by 217
Reducing motion artifacts in two-dimensional Fourier transform imaging
Haacke, E. M., & Patrick, J. L. (1986) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(86)91046-5 · Cited by 201
Initial Clinical Evaluation of a Whole Body Nuclear Magnetic Resonance (NMR) Tomograph
Young, I. R., Bailes, D. R., Burl, M., Collins, A. G., Smith, D. T., McDonnell, M. J., Orr, J. S., Banks, L. M., Bydder, G. M., Greenspan, R. H., et al. (1982) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198202000-00001 · Cited by 190
Functional Magnetic Resonance Imaging in Medicine and Physiology
Moonen, C. T. W., van Zijl, P. C. M., Frank, J. A., Le Bihan, D., & Becker, E. D. (1990) · Science · doi:10.1126/science.2218514 · Cited by 185
Magnetic resonance imaging of cavernous hemangioma of the liver: tissue-specific characterization
Stark, D., Felder, R., Wittenberg, J., Saini, S., Butch, R., White, M., Edelman, R., Mueller, P., Simeone, J., Cohen, A., et al. (1985) · American Journal of Roentgenology · doi:10.2214/ajr.145.2.213 · Cited by 183
Turner, R. (1988) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/21/10/008 · Cited by 175
Self-citationReal‐time movie imaging from a single cardiac cycle by NMR
Chapman, B. L. W., Turner, R., Ordidge, R. J., Doyle, M., Cawley, M. G., Coxon, R., Glover, P. M., & Mansfield, P. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050305 · Cited by 168
Self-citationPassive screening of switched magnetic field gradients
Turner, R., & Bowley, R. M. (1986) · Journal of Physics E: Scientific Instruments · doi:10.1088/0022-3735/19/10/023 · Cited by 166
Self-citationSensory stimulation by time‐varying magnetic fields
Cohen, M. S., Weisskoff, R. M., Rzedzian, R. R., & Kantor, H. L. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140226 · Cited by 164
Sensitivity in Fourier transform NMR spectroscopy of slowly relaxing systems
Waugh, J. S. (1970) · Journal of Molecular Spectroscopy · doi:10.1016/0022-2852(70)90205-5 · Cited by 164
Pituitary adenomas: high-resolution MR imaging at 1.5 T.
Kucharczyk, W., Davis, D. O., Kelly, W. M., Sze, G., Norman, D., & Newton, T. H. (1986) · Radiology · doi:10.1148/radiology.161.3.3786729 · Cited by 158
REAL-TIME CARDIAC IMAGING OF ADULTS AT VIDEO FRAME RATES BY MAGNETIC RESONANCE IMAGING
Doyle, M., Chapman, B., Turner, R., Ordidge, R. J., Cawley, M., Coxon, R., Glover, P., Coupland, R. E., Morris, G. K., & Worthington, B. S. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90185-6 · Cited by 144
Self-citationImprovements in snap-shot nuclear magnetic resonance imaging
Howseman, A., Stehling, M. K., Chapman, B. L. W., Coxon, R., Turner, R., Ordidge, R. J., Cawley, M. G., Glover, P. M., Mansfield, P., & COUPLAND, R. E. (1988) · British Journal of Radiology · doi:10.1259/0007-1285-61-729-822 · Cited by 140
Self-citationContrast in Rapid MR Imaging: T1− and T2-Weighted Imaging
Buxton, R. B., Edelman, R. R., Rosen, B. R., Wismer, G. L., & Brady, T. J. (1987) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198701000-00003 · Cited by 139
Instant images of the human heart using a new, whole-body MR imaging system
Rzedzian, R. R., & Pykett, I. L. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.149.2.245 · Cited by 139
Mechanisms of Contrast in NMR Imaging
Wehrli, F. W., MacFall, J. R., Shutts, D., Breger, R. K., & Herfkens, R. J. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198406000-00001 · Cited by 129
Volumetric NMR imaging with time‐varying gradients
Macovski, A. (1985) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910020105 · Cited by 125
IMPACT OF INTEGRATED CHILD DEVELOPMENT SERVICES ON INFANT MORTALITY RATE IN INDIA
Tandon, B. N., Sahai, A., & Vardhan, A. (1984) · The Lancet · doi:10.1016/s0140-6736(84)91066-3 · Cited by 122
Fast MR imaging: techniques and clinical applications.
Haacke, E. M., & Tkach, J. A. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.155.5.2120964 · Cited by 118
Echo‐planar high‐resolution flow velocity mapping
Firmin, D. N., Klipstein, R. H., Hounsfield, G. L., Paley, M. N. J., & Longmore, D. B. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910120304 · Cited by 113
Magnetic Resonance Imaging the Velocity Vector Components of Fluid Flow
Feinberg, D. A., Crooks, L. E., Sheldon, P. E., Hoenninger, J. C., Watts, J. C., & Arakawa, M. (1985) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910020606 · Cited by 112
High‐speed multislice T1 mapping using inversion‐recovery echo‐planar imaging
Ordidge, R. J., Gibbs, P., Chapman, B. L. W., Stehling, M. K., & Mansfield, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910160205 · Cited by 111
Self-citationThe potential impact of nuclear magnetic resonance imaging on cardiovascular diagnosis.
Kaufman, L., Crooks, L. E., Sheldon, P. W. E., Hricak, H., Herfkens, R. J., & Bank, W. (1983) · Circulation · doi:10.1161/01.cir.67.2.251 · Cited by 110
Measuring Random Microscopic Motion of Water in Tissues with MR Imaging: A Cat Brain Study
Bihan, D. L., MOONEN, C. T. W., van Zijl, P. C. M., Pekar, J. J., & Despres, D. (1991) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199101000-00002 · Cited by 106
Whole-body echo-planar MR imaging at 0.5 T.
Stehling, M. K., Howseman, A., Ordidge, R. J., Chapman, B. L. W., Turner, R., Coxon, R., Glover, P. M., Mansfield, P., & COUPLAND, R. E. (1989) · Radiology · doi:10.1148/radiology.170.1.2909106 · Cited by 95
Self-citationEcho‐planar imaging with asymmetric gradient modulation and inner‐volume excitation
Feinberg, D. A., Turner, R., Jakab, P. D., & von Kienlin, M. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130116 · Cited by 94
Self-citation0.3‐second flash mri of the human heart
Frahm, J., Merboldt, K. D., Bruhn, H., Gyngell, M. L., Hänicke, W., & Chien, D. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130114 · Cited by 93
Characteristics of partial flip angle and gradient reversal MR imaging.
Winkler, M. L., Ortendahl, D. A., Mills, T. C., Crooks, L. E., Sheldon, P. E., Kaufman, L., & Kramer, D. M. (1988) · Radiology · doi:10.1148/radiology.166.1.3275967 · Cited by 91
A unified description of NMR imaging, data‐collection strategies, and reconstruction
King, K. F., & Moran, P. R. (1984) · Medical Physics · doi:10.1118/1.595470 · Cited by 87
Lewis, C. E., Prato, F. S., Drost, D. J., & Nicholson, R. L. (1986) · Radiology · doi:10.1148/radiology.160.3.3737921 · Cited by 85
MR imaging: possibility of tissue characterization of brain tumors using T1 and T2 values.
Komiyama, M., Yagura, H., Baba, M., Yasui, T., Hakuba, A., Nishimura, S., & Inoue, Y. (1987) · PubMed · Cited by 85
MRI of “diffusion” in the human brain: New results using a modified CE‐FAST sequence
Merboldt, K., Bruhn, H., Frahm, J., Gyngell, M. L., Hänicke, W., & Deimling, M. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090316 · Cited by 84
Multishield active magnetic screening of coil structures in NMR
Mansfield, P., & Chapman, B. L. W. (1987) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(87)90283-6 · Cited by 82
Self-citationOptimizing tissue contrast in magnetic resonance imaging
Hendrick, R. E., Nelson, T. R., & Hendee, W. R. (1984) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(84)90005-5 · Cited by 81
Echo planar imaging of the human fetus in utero at 0.5 T
Mansfield, P., Stehling, M. K., Ordidge, R. J., Coxon, R., Chapman, B. L. W., Blamire, A. M., Gibbs, P., Johnson, I. R., Symonds, M. E., Worthington, B. S., et al. (1990) · British Journal of Radiology · doi:10.1259/0007-1285-63-755-833 · Cited by 79
Self-citationGastrointestinal tract: dynamic MR studies with echo-planar imaging.
Stehling, M. K., Evans, D. F., Lamont, G., Ordidge, R. J., Howseman, A., Chapman, B. L. W., Coxon, R., Mansfield, P., Hardcastle, J. D., & COUPLAND, R. E. (1989) · Radiology · doi:10.1148/radiology.171.1.2928545 · Cited by 73
Self-citationChien, D., Atkinson, D. J., & Edelman, R. R. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010108 · Cited by 72
Leo J. Rigler lecture. MR imaging of the liver
Ferrucci, J. T. (1986) · American Journal of Roentgenology · doi:10.2214/ajr.147.6.1103 · Cited by 68
Hyperthermia system combined with a magnetic resonance imaging unit
Delannoy, J., Bihan, D. L., Hoult, D. I., & Levin, R. L. (1990) · Medical Physics · doi:10.1118/1.596477 · Cited by 65
The limitations of NMR recalled-echo imaging techniques
Johnson, G., & Hutchison, J. M. S. (1985) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(85)90149-0 · Cited by 59
Dynamic spin-echo MRI of liver cancer using Gadolinium-DTPA: animal investigation
Saini, S., Stark, D. D., Brady, T. J., WITTENBERG, J., & Ferrucci, J. T. (1986) · American Journal of Roentgenology · doi:10.2214/ajr.147.2.357 · Cited by 58
Echo‐planar imaging of the human fetus in utero
Stehling, M. K., Mansfield, P., Ordidge, R. J., Coxon, R., Chapman, B. L. W., Blamire, A. M., Gibbs, P., Johnson, I. R., Symonds, M. E., Worhington, B. S., et al. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130214 · Cited by 47
Self-citationHepatic metastases in perspective
Adson, M. (1983) · American Journal of Roentgenology · doi:10.2214/ajr.140.4.695 · Cited by 46
Willis, A. L., Smith, D. L., Vigo, C., & Kluge, A. F. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90186-8 · Cited by 46
Inversion‐recovery echo‐planar imaging (ir‐epi) at 0.5 T
Stehling, M. K., Ordidge, R. J., Coxon, R., & Mansfield, P. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130320 · Cited by 42
Self-citationDyke award. Imaging of spinal CSF pulsation by 2DFT MR: significance during clinical imaging
Rubin, J. B., & Enzmann, D. R. (1987) · American Journal of Roentgenology · doi:10.2214/ajr.148.5.973 · Cited by 33
Advances in cardiac applications of subsecond flash MRI
Chien, D., Merboldt, K., Hänicke, W., Bruhn, H., Gyngell, M. L., & Frahm, J. (1990) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(90)90022-t · Cited by 33
On NMR spin imaging by magnetic field modulation
Feiner, L. F., & Locher, P. (1980) · Applied Physics A · doi:10.1007/bf00899875 · Cited by 29
Bradley, W. G., Kortman, K. E., & Crues, J. V. (1985) · Radiology · doi:10.1148/radiology.156.1.4001426 · Cited by 29
Transectional echo planar imaging of the heart in cyanotic congenital heart disease
Chrispin, A. R., Small, P., Rutter, N., COUPLAND, R. E., Doyle, M., Chapman, B. L. W., Coxon, R., Guilfoyle, D. N., Cawley, M. G., & Mansfield, P. (1986) · Pediatric Radiology · doi:10.1007/bf02386865 · Cited by 27
Self-citationComparative Efficiency of Different Pulse Sequences in MR Imaging
YOUNG, I. R., Burl, M., & Bydder, G. M. (1986) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198603000-00020 · Cited by 26
Observation of cerebrospinal fluid flow with echo-planar magnetic resonance imaging
Stehling, M. K., Firth, J. L., Worthington, B. S., Guilfoyle, D. N., Ordidge, R. J., Coxon, R., Blamire, A. M., Gibbs, P., Bullock, P. R., & Mansfield, P. (1991) · British Journal of Radiology · doi:10.1259/0007-1285-64-758-89 · Cited by 22
Self-citationUltrafast magnetic resonance scanning of the liver with echo-planar imaging
Stehling, M. K., Charnley, R., Blamire, A. M., Ordidge, R. J., Coxon, R., Gibbs, P., Hardcastle, J. D., & Mansfield, P. (1990) · British Journal of Radiology · doi:10.1259/0007-1285-63-750-430 · Cited by 21
Self-citationCrooks, L. E., Arakawa, M., Hylton, N. M., Avram, H. E., Hoenninger, J. C., Watts, J. C., Hale, J. D., & Kaufman, L. (1988) · Radiology · doi:10.1148/radiology.166.1.3336674 · Cited by 17
Snapshot echo-planar imaging methods: current trends and future perspectives
Mansfield, P., Blamire, A. M., Coxon, R., Gibbs, P., Guilfoyle, D. N., Harvey, P., & Symms, M. R. (1990) · Philosophical Transactions of the Royal Society of London Series A Physical and Engineering Sciences · doi:10.1098/rsta.1990.0177 · Cited by 17
Self-citationO’Callaghan, C., Small, P., Chapman, B. L. W., Coxon, R., Glover, P. M., Turner, R., Jaroszkiewicz, G., Howseman, A., Mansfield, P., & COUPLAND, R. E. (1987) · PubMed · Cited by 11
Self-citationCampbell, R. E. (1989) · Radiology · doi:10.1148/radiology.172.2.575 · Cited by 2
Research works printed but not linked: 22
- Belliveau, J. W., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 202 (1991).
- Bourland, J. D., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 1157 (1990).
- Budinger, T. F., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 276 (1990).
- EHMAN, L.R., AM J ROENTGENOL 143: 1175 (1985).
- Fischer, H., 75th Annual Meeting of the Radiological Society of North America: 276 (1989).
- HENKELMAN, R.M., REV MAGN RESON MED 2: 1 (1987).
- Higuchi, N., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 638 (1990).
- Kose, K., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 168 (1990).
- KUMAR, A, NMR FOURIER ZEUGMATOGRAPHY, JOURNAL OF MAGNETIC RESONANCE 18: 69 (1975).
- MOONEN, CTW, RADIOLOGY 171: 853 (1989). · DOI · Paper page
- Ordidge, R. J., Eighth Annual Meeting of the Society of Magnetic Resonance in Medicine Book of Abstracts: 889 (1989).
- PATRONAS, N, NEURORADIOLOGY 33 Supplement: 267 (1991).
- RADON, J, BER VERH SACHS AK MN 69: 262 (1917).
- Roemer, P. B., Fifth Annual Meeting of the Society of Magnetic Resonance in Medicine Book of Abstracts: 1067 (1986).
- ROSEN, B.R., JOURNAL OF GEOLOGICAL EDUCATION 5: 263 (1989).
- Stehling M. K. American Journal of Roentgenology in press.
- Stehling M. K. Radiology in press.
- STEHLING, M.K., ECHO-PLANAR MAGNETIC-RESONANCE IMAGING IN ABNORMAL PREGNANCIES, LANCET 2: 157 (1989).
- STEHLING, M.K., 8TH ANN M SOC MAGN R: 50 (1990).
- Wedeen, V. J., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 164 (1990).
- White, D., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 57 (1990).
- Wilke N. Radiology in press.
Cited by
Hämäläinen, M., Hari, R., Ilmoniemi, R. J., Knuutila, J., & Lounasmaa, O. V. (1993) · Reviews of Modern Physics · doi:10.1103/revmodphys.65.413 · Cited by 4,684
Ogawa, S., Tank, D. W., Menon, R., Ellermann, J. M., Kim, S. G., Merkle, H., & Ugurbil, K. (1992) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.89.13.5951 · Cited by 3,681
Edelman, R. R., & Warach, S. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303183281109 · Cited by 1,206
Yang, G., Yu, S., Dong, H., Slabaugh, G., Dragotti, P. L., Ye, X., Liu, F., Arridge, S., Keegan, J., Guo, Y., et al. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2785879 · Cited by 1,081
A hitchhiker's guide to diffusion tensor imaging
Soares, J. M., Marques, P., Alves, V., & Sousa, N. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00031 · Cited by 893
Metadata
- Authors
- Stehling, M. K., Turner, R., & Mansfield, P.
- Affiliations
- Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
- Venue
- Science
- Published
- 1991-10-04
- Volume
- 254
- Issue
- 5028
- Pages
- 43-50
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1991844483
- Cited by
- 623
- References
- 93
- Citations by year
- 2026: 11 · 2025: 18 · 2024: 11 · 2023: 18 · 2022: 21 · 2021: 22 · 2020: 25 · 2019: 29 · 2018: 19 · 2017: 23 · 2016: 23 · 2015: 21 · 2014: 18 · 2013: 18 · 2012: 8
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- Max Planck Digital Library (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- echo planar imaging, rapid MRI, cardiac function imaging, temperature mapping, blood pool imaging, perfusion imaging, functional MRI, cerebrospinal fluid flow, fetal MRI, ischemic heart disease, stroke, cancer diagnosis
- MeSH terms
- Diffusion, Humans, Magnetic Resonance Imaging, Motion, Regional Blood Flow, Time Factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.