Echo-Planar Imaging: Magnetic Resonance Imaging in a Fraction of a Second
The DOI matches its Crossref record; 93 of the 93 references it cites were found in a registry or an index.
Abstract
Progress has recently been made in implementing magnetic resonance imaging (MRI) techniques that can be used to obtain images in a fraction of a second rather than in minutes. Echo-planar imaging (EPI) uses only one nuclear spin excitation per image and lends itself to a variety of critical medical and scientific applications. Among these are evaluation of cardiac function in real time, mapping of water diffusion and temperature in tissue, mapping of organ blood pool and perfusion, functional imaging of the central nervous system, depiction of blood and cerebrospinal fluid flow dynamics, and movie imaging of the mobile fetus in utero. Through shortened patient examination times, higher patient throughput, and lower cost per MRI examination, EPI may become a powerful tool for early diagnosis of some common and potentially treatable diseases such as ischemic heart disease, stroke, and cancer.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Resonance Absorption by Nuclear Magnetic Moments in a Solid
Purcell, E. M., Torrey, H. C., & Pound, R. V. (1946) · Physical Review · doi:10.1103/physrev.69.37 · Cited by 6,053
Hahn, E. L. (1950) · Physical Review · doi:10.1103/physrev.80.580 · Cited by 5,085
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Le Bihan, D., Breton, E., Lallemand, D., Aubin, M. L., Vignaud, J., & Laval-Jeantet, M. (1988) · Radiology · doi:10.1148/radiology.168.2.3393671 · Cited by 3,169
RARE imaging: A fast imaging method for clinical MR
Hennig, J., Nauerth, A., & Friedburg, H. (1986) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910030602 · Cited by 2,081
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Self-citationTumor Detection by Nuclear Magnetic Resonance
Damadian, R. (1971) · Science · doi:10.1126/science.171.3976.1151 · Cited by 1,466
FLASH imaging: Rapid NMR imaging using low flip-angle pulses
Haase, A., Frahm, J., Matthaei, D., Hänicke, W., & Merboldt, K.-D. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.09.021 · Cited by 1,153
Research works printed but not linked: 22
- Belliveau, J. W., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 202 (1991).
- Bourland, J. D., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 1157 (1990).
- Budinger, T. F., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 276 (1990).
- EHMAN, L.R., AM J ROENTGENOL 143: 1175 (1985).
- Fischer, H., 75th Annual Meeting of the Radiological Society of North America: 276 (1989).
- HENKELMAN, R.M., REV MAGN RESON MED 2: 1 (1987).
- Higuchi, N., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 638 (1990).
- Kose, K., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 168 (1990).
- KUMAR, A, NMR FOURIER ZEUGMATOGRAPHY, JOURNAL OF MAGNETIC RESONANCE 18: 69 (1975).
- MOONEN, CTW, RADIOLOGY 171: 853 (1989). · DOI · Paper page
- Ordidge, R. J., Eighth Annual Meeting of the Society of Magnetic Resonance in Medicine Book of Abstracts: 889 (1989).
- PATRONAS, N, NEURORADIOLOGY 33 Supplement: 267 (1991).
- RADON, J, BER VERH SACHS AK MN 69: 262 (1917).
- Roemer, P. B., Fifth Annual Meeting of the Society of Magnetic Resonance in Medicine Book of Abstracts: 1067 (1986).
- ROSEN, B.R., JOURNAL OF GEOLOGICAL EDUCATION 5: 263 (1989).
- Stehling M. K. American Journal of Roentgenology in press.
- Stehling M. K. Radiology in press.
- STEHLING, M.K., ECHO-PLANAR MAGNETIC-RESONANCE IMAGING IN ABNORMAL PREGNANCIES, LANCET 2: 157 (1989).
- STEHLING, M.K., 8TH ANN M SOC MAGN R: 50 (1990).
- Wedeen, V. J., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 164 (1990).
- White, D., Ninth Annual Meeting of the Society of Magnetic Resonance in Medicine: Books of Abstracts: 57 (1990).
- Wilke N. Radiology in press.
Cited by
Items 501–600 of 729
The role of diffusion-weighted MRI in biological image-guided radiation therapy: a roadmap
Deng, J., Tadimalla, S., Seibert, T. M., Gach, H. M., van Houdt, P. J., Hormuth, D. A., Jia, X., Zou, J., Conlin, C. C., Karaman, M., et al. (2026) · Physics in Medicine and Biology · doi:10.1088/1361-6560/ae5d80 · Cited by 1
Tian, R., & Scheffler, K. (2026) · Magnetic Resonance in Medicine · doi:10.1002/mrm.70439 · Cited by 1
Les méthodes de la neuropsychologie
Mazoyer, B. M. (2001) · Questions de personne · doi:10.3917/dbu.eusta.2001.01.0179 · Cited by 1
Kumazawa, S., Yoshiura, T., & Honda, H. (2015) · Concepts in Magnetic Resonance Part B · doi:10.1002/cmr.b.21293 · Cited by 1
Experimental study on HASTE sequences: impacts of parameters on liver imaging
Tang, Y., Yamashita, Y., Abe, Y., Namimoto, T., & Takahashi, M. (1999) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(99)00019-1 · Cited by 1
Hawighorst, H., Knopp, M. V., Debus, J., Brix, G., Engenhart‐Cabillic, R., Schad, L. R., Grandy, M., Essig, M., & KAICK, G. V. (1997) · Der Radiologe · doi:10.1007/s001170050206 · Cited by 1
Basics and Performance of Cardiac Computed Tomography
Alomar, X., Castillo-Gallo, E., & Pons‐Lladó, G. (2007) · Springer eBooks · doi:10.1007/978-0-387-33048-8_2 · Cited by 1
Transcranial magnetic stimulation combined with EEG: a new brain imaging tool
Ilmoniemi, R. J., Karhu, J., Ollikainen, M., Näätänen, R., Ruohonen, J., Virtanen, J. P., Tiitinen, H., Ylöstalo, J., & Katila, T. E. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1998.746909 · Cited by 1
Estimating fetal brain motion with total-variation-based magnetic resonance image registration
Chen, L., Zhang, H., Wu, S., Yu, S., & Xie, Y. (2016) · World Congress on Intelligent Control and Automation · doi:10.1109/wcica.2016.7578230 · Cited by 1
Zhang, J., Yi, Z., Zhao, Y., Xiao, L., Hu, J., Man, C., Lau, V., Su, S. C., Chen, F., Leong, A. T. L., et al. (2023) · Magnetic Resonance in Medicine · doi:10.1002/mrm.29625 · Cited by 1
Physiology of Functional Activation
Detre, J. A. (2003) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-0205-0_60 · Cited by 1
Bano, S., Afzal, M. B., & Waraich, M. M. (2013) · Cited by 1
Miyati, T., Narita, H., AKAIWA, N., ISHIHARA, S., Kasai, H., SAKURAI, H., Sakurai, Y., NISHIGAKI, F., & YAMAUCHI, T. (1998) · Japanese Journal of Radiological Technology · doi:10.6009/jjrt.kj00001351911 · Cited by 1
Daimiwal, N., Martin, B., Sundararajan, M., & Shriram, R. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-981-10-8228-3_37 · Cited by 1
Peter, T., & Cherian, D. (2018) · Al-Azhar Assiut Medical Journal · doi:10.4103/azmj.azmj_34_17 · Cited by 1
Towards Gamers’ Experience Level Decoding with Optical Brain Imaging
Kiani, M., Andreu-Pérez, J., Hagras, H., Andreu, A. R., Pinto, M., Andreu, J., Reddy, P., & İzzetoğlu, K. (2019) · Computer Science and Electronic Engineering Conference · doi:10.1109/ceec47804.2019.8974320 · Cited by 1
Sappey‐Marinier, D., & Briguet, A. (2014) · Wiley eBooks · doi:10.1002/9781118761236.ch2 · Cited by 1
Lin, Y.-S., Chen, C., & Greenlee, M. W. (2022) · Scientific Reports · doi:10.1038/s41598-022-20592-y · Cited by 1
DWI Physics and Imaging Techniques
Kotian, R. P., & Koteshwar, P. (2022) · Springer eBooks · doi:10.1007/978-981-19-5001-8_3 · Cited by 1
Recent Advances of Magnetic Resonance Imaging in the Diagnosis of Spinal Cord Injury
(2022) · Biointerface Research in Applied Chemistry · doi:10.33263/briac133.288 · Cited by 1
Application of magnetic resonance imaging technology in the diagnosis of brain diseases
Zhu, Z. (2023) · Advances in Engineering Technology Research · doi:10.56028/aetr.6.1.563.2023 · Cited by 1
Diffusion MRI acquisition for tractography: Diffusion sequences
Campbell, J. S. W., Baete, S. H., Cohen‐Adad, J., Tournier, J., Szczepankiewicz, F., Beaulieu, C., Baron, C. A., Mani, M., Setsompop, K., Liao, C., et al. (2025) · Elsevier eBooks · doi:10.1016/b978-0-12-818894-1.00019-7 · Cited by 1
A self-attention model for robust rigid slice-to-volume registration of functional MRI
Khawaled, S., Afacan, O., Warfield, S. K., & Freiman, M. (2025) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2025.102643 · Cited by 2
Functional MRI: Theory and Practice
Turner, R., & Gadian, D. G. (2007) · Wiley eBooks · doi:10.1002/9780470034590.emrstm0180 · Cited by 1
Self-citationArantes, P. R. (2005) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.5.2005.tde-13102014-102921 · Cited by 1
Rullkötter, N. (2008) · PUB – Publications at Bielefeld University (Bielefeld University) · Cited by 1
Physiological MR signal variations within the brain at 3 T
Klose, U., Friese, S., Erb, M., & Grodd, W. (2007) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2007.024 · Cited by 1
Evaluating Computational Models of Vision with Functional Magnetic Resonance Imaging
Eickenberg, M. (2015) · theses.fr (ABES) · doi:10.70675/e993ca3fzfacbz4a13z8bc3zc7f28975f05a · Cited by 1
Investigating the effects of microstructure and magnetic susceptibility in MRI
Cronin, M. J. (2016) · Nottingham ePrints (University of Nottingham) · Cited by 1
Tchistiakova, E. (2016) · TSpace (University of Toronto) · Cited by 1
Bour, P. (2017) · theses.fr (ABES) · doi:10.70675/3cbb4ceez115az41c0z8311zd4ed6f7b165d · Cited by 1
Wang, J. (2017) · Apollo (University of Cambridge) · doi:10.17863/cam.20898 · Cited by 1
Advances in spatially encoded single-scan magnetic resonance imaging
Marhabaie, S. (2017) · theses.fr (ABES) · doi:10.70675/4df4494cz596dz4b7ez9492za07eed2ee153 · Cited by 1
Simegn, G. L. (2018) · Open University of Cape Town (University of Cape Town) · Cited by 1
Bennett, D. (2007) · Digital WPI · Cited by 1
Stomby, A. (2015) · DiVA at Umeå University (Umeå University) · Cited by 1
Magnetic Field Dependence of Spatial Frequency Encoding NMR
Plainchont, B., Farjon, J., & Giraud, N. (2016) · Wiley eBooks · doi:10.1002/9780470034590.emrstm1528 · Cited by 1
Rademakers, F. E., & Bogaert, J. G. (2000) · Medical radiology · doi:10.1007/978-3-642-60252-8_6 · Cited by 1
Application of Phase Imaging at High Field - MR Thermometry at 7 Tesla
Streicher, M. (2017) · Qucosa (Saxon State and University Library Dresden) · Cited by 1
Schnell, M. (1998) · FreiDok plus (Universitätsbibliothek Freiburg) · Cited by 1
Developing fMRI Technology for Stroke Recovery Research
Macintosh, B. J., & Macintosh, B. J. (2007) · TSpace (University of Toronto) · Cited by 1
Tian, R., Uecker, M., Holder, O., Povolni, P., Steffen, T., & Scheffler, K. (2026) · arXiv (Cornell University) · doi:10.48550/arxiv.2601.05469 · Cited by 1
Rolland, X. (2022) · theses.fr (ABES) · doi:10.70675/5b1d2250zbda7z4fb6z8549z332f95038cda · Cited by 1
Applications of Magnetic Resonance to Current Detection and Microscale Flow Imaging
Halpern-Manners, N. W. (2011) · eScholarship (California Digital Library) · Cited by 1
Functional MRI in Image Guided Neurosurgery
Sankar, T., & Cosgrove, G. R. (2009) · Springer eBooks · doi:10.1007/978-3-540-69960-6_20 · Cited by 1
Clinical Applications of Neuroimaging Using Echo-Planar Imaging
Siewert, B., & Warach, S. J. (1998) · Springer eBooks · doi:10.1007/978-3-642-80443-4_14
RF Pulse Designs for Signal Recovery in T2*-Weighted Functional Magnetic Resonance Imaging.
Yip, C. (2007) · Deep Blue (University of Michigan)
Criteria and awareness in perceptual decision
Fleming, S. M. (2011) · UCL Discovery (University College London)
Optimal signal recovery from interleaved FMRI data
Parker, D., Gerraty, R. T., & Razlighi, Q. R. (2015) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2015.7164131
Liu, X., Zhong, J., & Waag, R. C. (2009) · UR Research (University of Rochester)
Statistical wavelet analysis of functional images of the brain
Feilner, M. (2002) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-2671
Ischemic Heart Disease: Assessment of Ventricular Function with MRI
Dymarkowski, S., & Bogaert, J. G. (2006) · Springer eBooks · doi:10.1007/0-387-21590-5_30
Diffusion-Weighted Whole-Body Imaging: Tumor Staging Applications
Sperling, D., & Bard, R. L. (2013) · Springer eBooks · doi:10.1007/978-3-642-40429-0_9
Meier, S. (2004) · edoc (University of Basel) · doi:10.5451/unibas-003413444
Diffusion Tensor Imaging as a Diagnostic and Research Tool: A Study on Preterm Infants
Saunavaara, V. (2014) · UTUPub (University of Turku)
Mansfield, P. R. (2007) · Wiley eBooks · doi:10.1002/9780470034590.emrstm0145
Self-citationECHO-PLANAR MAGNETIC RESONANCE ANGIOGRAPHY
Cohen, M. S. (1993) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/s1064-9689(21)00314-7
Coronary Artery Disease Evaluated by MRI
Edelman, R. R., & Manning, W. J. (2007) · Wiley eBooks · doi:10.1002/9780470034590.emrstm0094
Magnetic Resonance Imaging, Functional
Richter, W. (2000) · Wiley eBooks · doi:10.1002/9780470027318.a0109
16-MDCT : A New Modality for Diagnosis of Cardiac Diseases
Lim, T. (2003) · Journal of the Korean Medical Association · doi:10.5124/jkma.2003.46.6.535
Choi, K.-W., Son, S.-Y., Jeong, M., & Min, J.-W. (2011) · Journal of the Korea Academia-Industrial cooperation Society · doi:10.5762/kais.2011.12.11.5005
Joint multi-shot multi-channel image reconstruction in compressive diffusion weighted MR imaging
Zhang, H., Chen, Y., Pasiliao, E. L., & Huang, F. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2082104
The Historical Development of Echo-Planar Magnetic Resonance Imaging
Turner, R., Schmitt, F., & Stehling, M. K. (1998) · Springer eBooks · doi:10.1007/978-3-642-80443-4_1
Self-citationUltrafast Imaging of the Cardiovascular System
Debatin, J. F. (1996) · Springer eBooks · doi:10.1007/978-88-470-2194-5_27
Stimulus content effect on the visual cortex with functional MRI
Munoz, P., & Micheli-Tzanakou, E. (2002) · IEEE Annual Northeast Bioengineering Conference (NEBEC) · doi:10.1109/nebc.1998.664871
Designing Scalable Biological Interfaces
Marblestone, A. H. (2014) · Digital Access to Scholarship at Harvard (DASH) (Harvard University)
An optimized magnetic tissue tagging sequence for echo-planar imaging
Al‐Omari, F. A., Chwialkowski, M. P., Clarke, G. D., & Peshock, R. M. (2002) · Proceedings - IEEE Symposium on Computer-Based Medical Systems · doi:10.1109/cbms.1998.701326
Bildgebende Verfahren bei psychischen Störungen
Braus, D. F., Tost, H., & Demirakça, T. (2010) · Springer eBooks · doi:10.1007/978-3-540-72340-0_6
Bogren, H. G., & Buonocore, M. H. (2006) · Springer eBooks · doi:10.1007/0-387-21590-5_14
Minna, & Mäkiranta (2004)
Elias, L. J. (2013) · Springer eBooks · doi:10.1007/978-1-4614-6852-3_17
Abdominal Diffusion Imaging Using Echo-Planar Imaging
Müller, M. F., & Prasad, P. V. (1998) · Springer eBooks · doi:10.1007/978-3-642-80443-4_11
Taschner, C. A. (2000) · edoc Publication server (Humboldt University of Berlin) · doi:10.18452/14527
Ayad, O. (2016) · uO Research (University of Ottawa) · doi:10.20381/ruor-5979
Gehi, A. K. (1996) · DSpace@MIT (Massachusetts Institute of Technology)
Nosrat-Makouei, B. (2008) · Summit (Simon Fraser University)
Kim, J., Yoo, J., & Ye, J. C. (2007) · Springer eBooks · doi:10.1007/978-3-540-36841-0_392
Siewert, B., Edelman, R. R., & Manning, W. J. (1996) · Medical radiology · doi:10.1007/978-3-642-97926-2_13
Neuroimaging as a Research Tool in Human Essential Hypertension
Dyson, K. S., & Hoge, R. D. (2016) · Springer eBooks · doi:10.1007/978-3-319-25616-0_4
Spettroscopia RM del protone nella diagnosi dei tumori cerebrali
Falini, A., Calabrese, G., Lipari, S., Terreni, M. R., & Scotti, G. (1994) · Rivista di Neuroradiologia · doi:10.1177/19714009940070s126
Comparetto, C., & Borruto, F. (2014) · Evidence Based Women s Health Journal · doi:10.1097/01.ebx.0000438947.86514.90
20 Functional MRI in Image Guided
Sankar, N., & Cosgrove, G. R. (2009)
Microcirculation and Perfusion
Bihan, D. L. (1994) · Elsevier eBooks · doi:10.1016/b978-0-12-283980-1.50008-9
A bright future for magnetic resonance
Bodenhausen, G. (2015) · Resonance · doi:10.1007/s12045-015-0274-4
Diffusion Magnetic Resonance Imaging
Fütterer, J. J. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4377-1575-0.10006-4
G N Ramachandran’s contributions to medical imaging: Substance from shadows
Kumar, A., & Ajoy, A. (2016) · Resonance · doi:10.1007/s12045-016-0378-5
Neurovascular Coupling, the BOLD Signal and MRI
Gabbiani, F., & Cox, S. J. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801895-8.00015-4
Kim, S. (2017) · MPG.PuRe (Max Planck Society)
Correlation Imaging for Real-time Cardiac MRI
Silva, D., & Kumara, W. M. (2016) · OhioLink ETD Center (Ohio Library and Information Network)
Magnetic resonance imaging of granular matter
Penn, A., Köhl, M. H., Pruessmann, K. P., & Müller, C. R. (2014) · tub.dok (Hamburg University of Technology)
Burazanis, S. (2009) · mediaTUM (Technical University of Munich)
Kämpfe, N. (2005) · mediaTUM (Technical University of Munich)
Sairanen, V. (2018) · Helda - University of Helsinki Institutional Repository
Barreto, F. R. (2016) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/t.59.2016.tde-29092016-142720
Translationale interventionelle Kinderkardiologie
Schmitt, B. (2018) · doi:10.17169/refubium-14
Early Tumor Detection and Therapeutics Using an Advanced Magnetic Resonance Nano-Theranostic System
Wang, C. (2018) · eScholarship (California Digital Library)
Kinetic Modelling of Dynamic Contrast-Enhanced MR Images: Impact of the Arterial Input Function
Evensen, T. S. (2018) · NVA (Nasjonalt vitenarkiv)
Ruthotto, L., & Modersitzki, J. (2014) · Springer eBooks · doi:10.1007/978-3-642-27795-5_39-2
Metadata
- Authors
- Stehling, M. K., Turner, R., & Mansfield, P.
- Affiliations
- Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
- Venue
- Science
- Published
- 1991-10-04
- Volume
- 254
- Issue
- 5028
- Pages
- 43-50
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W1991844483
- Cited by
- 623
- References
- 93
- Citations by year
- 2026: 11 · 2025: 18 · 2024: 11 · 2023: 18 · 2022: 21 · 2021: 22 · 2020: 25 · 2019: 29 · 2018: 19 · 2017: 23 · 2016: 23 · 2015: 21 · 2014: 18 · 2013: 18 · 2012: 8
- FWCI
- 5.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Science (publishedVersion)
- PubMed (publishedVersion)
- Max Planck Digital Library (submittedVersion)
- MPG.PuRe (Max Planck Society) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- echo planar imaging, rapid MRI, cardiac function imaging, temperature mapping, blood pool imaging, perfusion imaging, functional MRI, cerebrospinal fluid flow, fetal MRI, ischemic heart disease, stroke, cancer diagnosis
- MeSH terms
- Diffusion, Humans, Magnetic Resonance Imaging, Motion, Regional Blood Flow, Time Factors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.