The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Primary Sequence Information from Intact Proteins by Electrospray Ionization Tandem Mass Spectrometry
Abstract
Tandem mass spectrometry has been used to obtain information related to portions of the primary sequence for an intact protein, bovine ribonuclease A. Multiply charged molecular ions, generated by electrospray ionization, were collisionally dissociated at low energies in a triple quadrupole mass spectrometer to yield singly and multiply charged fragment ions that can be assigned to the known sequence of the protein. Dissociation of the highly charged molecular ions resulted in pairs of complementary product ions. The higher order (gas-phase) protein structure affects the dissociation processes, as observed in comparisons of tandem mass spectra of the native and disulfide-reduced forms of ribonuclease A.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Protein sequencing by tandem mass spectrometry.
Hunt, D. F., Yates, J. R., Shabanowitz, J., Winston, S., & Hauer, C. R. (1986) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.83.17.6233 · Cited by 1,180
Contributions of mass spectrometry to peptide and protein structure
Biemann, K. (1988) · Biological Mass Spectrometry · doi:10.1002/bms.1200160119 · Cited by 1,015
Covey, T. R., Bonner, R. F., Shushan, B. I., Henion, J., & Boyd, R. K. (1988) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290021111 · Cited by 593
Interpreting mass spectra of multiply charged ions
Mann, M., Meng, C. K., & Fenn, J. B. (1989) · Analytical Chemistry · doi:10.1021/ac00190a023 · Cited by 588
McLafferty, F. W. (1981) · Science · doi:10.1126/science.7280693 · Cited by 384
Characterization by Tandem Mass Spectrometry of Structural Modifications in Proteins
Biemann, K., & Scoble, H. A. (1987) · Science · doi:10.1126/science.3303336 · Cited by 365
252Cf‐Plasma Desorption Mass Spectrometry
Sundqvist, B., & Macfarlane, R. D. (1985) · Mass Spectrometry Reviews · doi:10.1002/mas.1280040403 · Cited by 309
Loo, J. A., Udseth, H. R., & Smith, R. D. (1989) · Analytical Biochemistry · doi:10.1016/0003-2697(89)90153-x · Cited by 264
Self-citation
Cited by
Mass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Studying noncovalent protein complexes by electrospray ionization mass spectrometry
Loo, J. A. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:1<1::aid-mas1>3.0.co;2-l · Cited by 1,182
Self-citationBanerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Smith, R. D., Loo, J. A., Loo, R. R. O., Busman, M., & Udseth, H. R. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100504 · Cited by 569
Self-citation[22] Electrospray ionization mass spectrometry
Edmonds, C. G., & Smith, R. D. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93430-s · Cited by 508
Self-citationLoo, J. A. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00298-0 · Cited by 444
Self-citationExtending Top-Down Mass Spectrometry to Proteins with Masses Greater Than 200 Kilodaltons
Han, X., Jin, M., Breuker, K., & McLafferty, F. W. (2006) · Science · doi:10.1126/science.1128868 · Cited by 328
Hoaglund-Hyzer, C. S., Counterman, A. E., & Clemmer, D. E. (1999) · Chemical Reviews · doi:10.1021/cr980139g · Cited by 320
Mass spectrometry of peptides and proteins
Wysocki, V. H., Resing, K. A., Zhang, Q., & Cheng, G. (2005) · Methods · doi:10.1016/j.ymeth.2004.08.013 · Cited by 307
Loo, J. A., Loo, R. R. O., Udseth, H. R., Edmonds, C. G., & Smith, R. D. (1991) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290050303 · Cited by 291
Self-citation‘Top down’ protein characterization via tandem mass spectrometry
Reid, G. E., & McLuckey, S. A. (2002) · Journal of Mass Spectrometry · doi:10.1002/jms.346 · Cited by 285
Henderson, L. E., Bowers, M. A., Sowder, R. C., Serabyn, S. A., Johnson, D. G., Bess, J. W., Arthur, L. O., Bryant, D. K., & Fenselau, C. (1992) · Journal of Virology · doi:10.1128/jvi.66.4.1856-1865.1992 · Cited by 283
Collisional Activation of Large Multiply Charged Ions Using Fourier Transform Mass Spectrometry
Senko, M. W., Speir, J. P., & McLafferty, F. W. (1994) · Analytical Chemistry · doi:10.1021/ac00090a003 · Cited by 263
Direct Calculation of Electron Transfer Parameters through Constrained Density Functional Theory
Wu, Q., & Van Voorhis, T. (2006) · The Journal of Physical Chemistry A · doi:10.1021/jp061848y · Cited by 257
Deconvolution and Database Search of Complex Tandem Mass Spectra of Intact Proteins
Liu, X., Inbar, Y., Dorrestein, P. C., Wynne, C., Edwards, N., Souda, P., Whitelegge, J. P., Bafna, V., & Pevzner, P. A. (2010) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m110.002766 · Cited by 170
Roberts, D. S., Loo, J. A., Tsybin, Y. O., Liu, X., Wu, S., Chamot-Rooke, J., Agar, J. N., Paša-Tolić, L., Smith, L. M., & Ge, Y. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00318-2 · Cited by 161
Self-citationProtein Identification Using Top-Down Spectra
Liu, X., Sirotkin, Y., Shen, Y., Anderson, G., Tsai, Y. S., Ting, Y. S., Goodlett, D. R., Smith, R. D., Bafna, V., & Pevzner, P. A. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.008524 · Cited by 153
Self-citationLermyte, F., Tsybin, Y. O., O’Connor, P. B., & Loo, J. A. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02201-x · Cited by 132
Self-citationWongkongkathep, P., Han, J. Y., Choi, T. S., Yin, S., Kim, H. I., & Loo, J. A. (2018) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-018-2002-2 · Cited by 71
“(This process was previously termed nozzle-skimmer dissociation (NSD) [65] and now sometimes called in-source CAD or IS-CAD.)”
InfluentialSelf-citationThe benefits (and misfortunes) of SDS in top-down proteomics
Kachuk, C., & Doucette, A. A. (2018) · Journal of Proteomics · doi:10.1016/j.jprot.2017.03.002 · Cited by 39
Lakshmanan, R., Wolff, J. J., Alvarado, R., & Loo, J. A. (2014) · PROTEOMICS · doi:10.1002/pmic.201300339 · Cited by 24
“Protein top-down MS yields the intact mass(es) of the proteins [4, 5] and the presence of “proteoforms” [6], which cannot be efficiently identified by conventional bottomup methods.”
BackgroundSelf-citation
Metadata
- Authors
- Loo, J. A., Edmonds, C. G., & Smith, R. D.
- Venue
- Science
- Published
- 1990-04-13
- Volume
- 248
- Issue
- 4952
- Pages
- 201-204
- ISSN
- 0036-8075 (ISSN-L)
- 1095-9203
- OpenAlex
- W2023887263
- Cited by
- 300
- References
- 16
- FWCI
- 11.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.