Simultaneous Detection of Influenza Viruses A and B Using Real-Time Quantitative PCR
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Since influenza viruses can cause severe illness, timely diagnosis is important for an adequate intervention. The available rapid detection methods either lack sensitivity or require complex laboratory manipulation. This study describes a rapid, sensitive detection method that can be easily applied to routine diagnosis. This method simultaneously detects influenza viruses A and B in specimens of patients with respiratory infections using a TaqMan-based real-time PCR assay. Primers and probes were selected from highly conserved regions of the matrix protein gene of influenza virus A and the hemagglutinin gene segment of influenza virus B. The applicability of this multiplex PCR was evaluated with 27 influenza virus A and 9 influenza virus B reference strains and isolates. In addition, the specificity of the assay was assessed using eight reference strains of other respiratory viruses (parainfluenza viruses 1 to 3, respiratory syncytial virus Long strain, rhinoviruses 1A and 14, and coronaviruses OC43 and 229E) and 30 combined nose and throat swabs from asymptomatic subjects. Electron microscopy-counted stocks of influenza viruses A and B were used to develop a quantitative PCR format. Thirteen copies of viral RNA were detected for influenza virus A, and 11 copies were detected for influenza virus B, equaling 0.02 and 0.006 50% tissue culture infective doses, respectively. The diagnostic efficacy of the multiplex TaqMan-based PCR was determined by testing 98 clinical samples. This real-time PCR technique was found to be more sensitive than the combination of conventional viral culturing and shell vial culturing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heid, C. A., Stevens, J., Livak, K. J., & Williams, P. M. (1996) · Genome Research · doi:10.1101/gr.6.10.986 · Cited by 6,174
Rapid and simple method for purification of nucleic acids
Boom, R., Sol, C. J., Salimans, M. M., Jansen, C. L., Wertheim-van Dillen, P. M., & van der Noordaa, J. (1990) · Journal of Clinical Microbiology · doi:10.1128/jcm.28.3.495-503.1990 · Cited by 5,266
Hayden, F. G., Osterhaus, A. D. M. E., Treanor, J. J., Fleming, D. M., Aoki, F. Y., Nicholson, K. G., Bohnen, A. M., Hirst, H. M., Keene, O., & Wightman, K. (1997) · New England Journal of Medicine · doi:10.1056/nejm199709253371302 · Cited by 762 · cited 1×
“Moreover, since the concentrations of viable virus can decline rapidly after the first few days of the infection, the virus can become undetectable by culturing in the later course of the infection (7).”
BackgroundHayden, F. G., Treanor, J. J., Fritz, R. S., Lobo, M., Betts, R. F., Miller, M., Kinnersley, N., Mills, R. G., Ward, P., & Straus, S. E. (1999) · JAMA · doi:10.1001/jama.282.13.1240 · Cited by 550 · cited 1×
“Recently published results of clinical trials using new anti-influenza virus compounds, the neuraminidase inhibitors, demonstrated that these drugs are effective against influenza viruses A and B and are most effective when administered early, when symptoms first emerge (6, 8, 12).”
BackgroundUse of the Selective Oral Neuraminidase Inhibitor Oseltamivir to Prevent Influenza
Hayden, F. G., Atmar, R. L., Schilling, M., Johnson, C., Poretz, D., Paar, D., Huson, L., Ward, P., & Mills, R. G. (1999) · New England Journal of Medicine · doi:10.1056/nejm199910283411802 · Cited by 512
(1998) · The Lancet · doi:10.1016/s0140-6736(98)10190-3 · Cited by 351
Multiplex detection of four pathogenic retroviruses using molecular beacons
Vet, J. A. M., Majithia, A. R., Marras, S. A. E., Tyagi, S., Dube, S., Poiesz, B. J., & Kramer, F. R. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.11.6394 · Cited by 322
Schweiger, B., Zadow, I., Heckler, R., Timm, H., & Pauli, G. (2000) · Journal of Clinical Microbiology · doi:10.1128/jcm.38.4.1552-1558.2000 · Cited by 202
Ellis, J. S., Fleming, D. M., & Zambon, M. C. (1997) · Journal of Clinical Microbiology · doi:10.1128/jcm.35.8.2076-2082.1997 · Cited by 172
Typing and subtyping of influenza viruses in clinical samples by PCR
Wright, K. E., Wilson, G. A., Novosad, D., Dimock, C., Tan, D., & Weber, J. M. (1995) · Journal of Clinical Microbiology · doi:10.1128/jcm.33.5.1180-1184.1995 · Cited by 166
Cited by
Mackay, I. M. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.6.1292 · Cited by 1,318
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Real-time PCR in the microbiology laboratory
Mackay, I. M. (2004) · Clinical Microbiology and Infection · doi:10.1111/j.1198-743x.2004.00722.x · Cited by 807
Milton, D. K., Fabian, M. P., Cowling, B. J., Grantham, M. L., & McDevitt, J. J. (2013) · PLoS Pathogens · doi:10.1371/journal.ppat.1003205 · Cited by 669
Aerosol transmission of influenza A virus: a review of new studies
Tellier, R. (2009) · Journal of The Royal Society Interface · doi:10.1098/rsif.2009.0302.focus · Cited by 589
Real-time reverse transcription PCR (qRT-PCR) and its potential use in clinical diagnosis
Bustin, S. A., & Mueller, R. (2005) · Clinical Science · doi:10.1042/cs20050086 · Cited by 529
Influenza Virus in Human Exhaled Breath: An Observational Study
Fabian, P., McDevitt, J. J., DeHaan, W. H., Fung, R. O. P., Cowling, B. J., Chan, K. H., Leung, G. M., & Milton, D. K. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002691 · Cited by 496
Detection of Respiratory Viruses by Molecular Methods
Mahony, J. B. (2008) · Clinical Microbiology Reviews · doi:10.1128/cmr.00037-07 · Cited by 496
Inactivation of influenza A viruses in the environment and modes of transmission: A critical review
Weber, T. P., & Stilianakis, N. I. (2008) · Journal of Infection · doi:10.1016/j.jinf.2008.08.013 · Cited by 488
Templeton, K. E., Scheltinga, S. A., Beersma, M. F. C., Kroes, A. C. M., & Claas, E. C. J. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.4.1564-1569.2004 · Cited by 468
Tang, J. W., Bahnfleth, W. P., Bluyssen, P. M., Buonanno, G., Jimenez, J. L., Kurnitski, J., Li, Y., Miller, S., Sekhar, C., Morawska, L., et al. (2021) · Journal of Hospital Infection · doi:10.1016/j.jhin.2020.12.022 · Cited by 350
van der Sluijs, K. F., van Elden, L. J. R., Nijhuis, M., Schuurman, R., Pater, J. M., Florquin, S., Goldman, M., Jansen, H. M., Lutter, R., & van der Poll, T. (2004) · The Journal of Immunology · doi:10.4049/jimmunol.172.12.7603 · Cited by 334
Self-citationWard, C. (2004) · Journal of Clinical Virology · doi:10.1016/s1386-6532(03)00122-7 · Cited by 325
Pathogenic Human Viruses in Coastal Waters
Griffin, D. W., Donaldson, K. A., Paul, J. H., & Rose, J. B. (2003) · Clinical Microbiology Reviews · doi:10.1128/cmr.16.1.129-143.2003 · Cited by 294
Brown, D. M., Dilzer, A. M., Meents, D. L., & Swain, S. L. (2006) · The Journal of Immunology · doi:10.4049/jimmunol.177.5.2888 · Cited by 282
Yang, W., Elankumaran, S., & Marr, L. C. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2010.0686 · Cited by 260
Detection and monitoring of virus infections by real-time PCR
Watzinger, F., Ebner, K., & Lion, T. (2006) · Molecular Aspects of Medicine · doi:10.1016/j.mam.2005.12.001 · Cited by 281
van Elden, L. J. R., van Loon, A. M., van Alphen, F., Hendriksen, K. A. W., Hoepelman, A. I. M., van Kraaij, M. G. J., Oosterheert, J., Schipper, P., Schuurman, R., & Nijhuis, M. (2004) · The Journal of Infectious Diseases · doi:10.1086/381207 · Cited by 225
“The reverse transcription and cDNA synthesis were both performed as described elsewhere [17], and the products were stored at 70 C until further use.”
MethodSelf-citationQuantitation of Viral Load Using Real-Time Amplification Techniques
Niesters, H. G. M. (2001) · Methods · doi:10.1006/meth.2001.1264 · Cited by 220
Molecular diagnosis of respiratory virus infections
Mahony, J. B., Petrich, A., & Smieja, M. (2011) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2011.640976 · Cited by 215
“02 TCID 50 , more sensitive than shell vial culture based on testing 98 specimens van Elden et al.(22)”
BackgroundSublingual vaccination with influenza virus protects mice against lethal viral infection
Song, J.-H., Nguyen, H. H., Cuburu, N., Horimoto, T., Ko, S.-Y., Park, S.-H., Czerkinsky, C., & Kweon, M.-N. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0708684105 · Cited by 203
Skowronski, D. M., Masaro, C., Kwindt, T. L., Mak, A., Petric, M., Li, Y., Sebastian, R., Chong, M., Tam, T., & De Serres, G. (2007) · Vaccine · doi:10.1016/j.vaccine.2006.10.002 · Cited by 202
Rodríguez, R. A., Pepper, I. L., & Gerba, C. P. (2009) · Applied and Environmental Microbiology · doi:10.1128/aem.01150-08 · Cited by 200
“Realtime PCR (qPCR) has been more successful for multiple viral detection, because it can analyze each target independently in the same assay by using specific internal probes binding to different fluorochromes that the real-time PCR equipment can analyze independently (12, 41, 44, 54, 89).”
BackgroundInterleukin-10 Gene Expression in Acute Virus-induced Asthma
Grissell, T. V., Powell, H., Shafren, D. R., Boyle, M. J., Hensley, M. J., Jones, P. D., Whitehead, B. F., & Gibson, P. G. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200412-1621oc · Cited by 199
“tant cDNA was assayed for human rhinovirus, enterovirus, respiratory syncytial virus, and metapneumovirus RNA transcripts by agarose gel PCR (ThermoCycler; Thermo Electron Molecular Biology, Middlesex, UK) (26‐28) and for human influenza types A and B ( 29 ) by real-time PCR (ABI Prism 7700 sequence detector; Applied…”
MethodPoor Clinical Sensitivity of Rapid Antigen Test for Influenza A Pandemic (H1N1) 2009 Virus
Drexler, J. F., Helmer, A., Kirberg, H., Reber, U., Panning, M., Müller, M., Höfling, K., Matz, B., Drosten, C., & Eis-Hübinger, A. M. (2009) · Emerging Infectious Diseases · doi:10.3201/eid1510.091186 · Cited by 185
“The sensitivity of BinaxNOW in comparison with a standard RTPCR assay (7) was 37.”
Methodvan Elden, L. J. R., van Kraaij, M. G. J., Nijhuis, M., Hendriksen, K. A. W., Dekker, A. W., Rozenberg‐Arska, M., & van Loon, A. M. (2002) · Clinical Infectious Diseases · doi:10.1086/338238 · Cited by 177
“In our hospital, nested reverse-transcriptase PCR (RT-PCR) techniques have been developed to detect the following respiratory viruses: parainfluenza viruses 1–3, RSV, rhinoviruses, influenza viruses A and B [9], enteroviruses, and coronaviruses.”
MethodSelf-citationAdvances in Real‐Time PCR: Application to Clinical Laboratory Diagnostics
(2005) · Advances in Clinical Chemistry · doi:10.1016/s0065-2423(05)40006-2 · Cited by 164
“A significant number of real-time PCR assays have been developed and applied for detection, quantification, and diVerentiation of viruses inducing a wide range of human and animal diseases such as coronavirus [139] , flaviviruses [140] [141] [142] , gyrovirus [21] , hepadnaviruses [143, 144] , herpesviruses [145] [146…”
MethodHunzeker, J., Padgett, D. A., Sheridan, P. A., Dhabhar, F. S., & Sheridan, J. F. (2004) · Brain, Behavior, and Immunity · doi:10.1016/j.bbi.2003.12.010 · Cited by 60
Aebi, T., Weisser, M., Bucher, E., Hirsch, H. H., Marsch, S., & Siegemund, M. (2010) · BMC Infectious Diseases · doi:10.1186/1471-2334-10-308 · Cited by 51
“5 log10 copies/ml [19].”
Fabian, P., McDevitt, J. J., Lee, W.-M., Houseman, E. A., & Milton, D. K. (2009) · J. Environ. Monit. · doi:10.1039/b813520g · Cited by 49
Influenza Virus-Specific Immunological Memory Is Enhanced by Repeated Social Defeat
Mays, J. W., Bailey, M. T., Hunzeker, J. T., Powell, N. D., Papenfuss, T., Karlsson, E. A., Padgett, D. A., & Sheridan, J. F. (2010) · The Journal of Immunology · doi:10.4049/jimmunol.0900183 · Cited by 37
“Cytokine primer and probe sequences were developed with Primer Express Software from PE Biosystems (Foster City, CA), and the influenza A matrix (M1) protein primers and probe were based on a previously published sequence (48).”
Wren, J. T., Blevins, L. K., Pang, B., King, L. B., Perez, A. C., Murrah, K. A., Reimche, J. L., Alexander-Miller, M. A., & Swords, W. E. (2014) · Infection and Immunity · doi:10.1128/iai.01856-14 · Cited by 31
Metadata
- Authors
- van Elden, L. J. R., Nijhuis, M., Schipper, P., Schuurman, R., & van Loon, A. M.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2001-01
- Volume
- 39
- Issue
- 1
- Pages
- 196-200
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2169706295
- Cited by
- 456
- References
- 15
- FWCI
- 14.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.