Ultrasonic locating devices for central venous cannulation: meta-analysis
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Objectives To assess the evidence for the clinical effectiveness of ultrasound guided central venous cannulation. Data sources 15 electronic bibliographic databases, covering biomedical, science, social science, health economics, and grey literature. Design Systematic review and meta-analysis of randomised controlled trials. Populations Patients scheduled for central venous access. Intervention reviewed Guidance using real time two dimensional ultrasonography or Doppler needles and probes compared with the anatomical landmark method of cannulation. Data extraction Risk of failed catheter placement (primary outcome), risk of complications from placement, risk of failure on first attempt at placement, number of attempts to successful catheterisation, and time (seconds) to successful catheterisation. Data synthesis 18 trials (1646 participants) were identified. Compared with the landmark method, real time two dimensional ultrasound guidance for cannulating the internal jugular vein in adults was associated with a significantly lower failure rate both overall (relative risk 0.14, 95% confidence interval 0.06 to 0.33) and on the first attempt (0.59, 0.39 to 0.88). Limited evidence favoured two dimensional ultrasound guidance for subclavian vein and femoral vein procedures in adults (0.14, 0.04 to 0.57 and 0.29, 0.07 to 1.21, respectively). Three studies in infants confirmed a higher success rate with two dimensional ultrasonography for internal jugular procedures (0.15, 0.03 to 0.64). Doppler guided cannulation of the internal jugular vein in adults was more successful than the landmark method (0.39, 0.17 to 0.92), but the landmark method was more successful for subclavian vein procedures (1.48, 1.03 to 2.14). No significant difference was found between these techniques for cannulation of the internal jugular vein in infants. An indirect comparison of relative risks suggested that two dimensional ultrasonography would be more successful than Doppler guidance for subclavian vein procedures in adults (0.09, 0.02 to 0.38). Conclusions Evidence supports the use of two dimensional ultrasonography for central venous cannulation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schulz (1995) · doi:10.1001/jama.1995.03520290060030 · Cited by 5,634
Interaction revisited: the difference between two estimates.
Altman, D. G., & Bland, J. M. (2003) · BMJ · doi:10.1136/bmj.326.7382.219 · Cited by 3,203
A prospective randomized trial
(1995) · Nihon Gekakei Rengo Gakkaishi (Journal of Japanese College of Surgeons) · doi:10.4030/jjcs1979.20.2_191 · Cited by 1,619
Ultrasound guidance for placement of central venous catheters: A meta-analysis of the literature
Randolph, A. G., Cook, D. J., Gonzales, C. A., & Pribble, C. G. (1996) · Critical Care Medicine · doi:10.1097/00003246-199612000-00020 · Cited by 852
Trottier, S. J., Veremakis, C., O’Brien, J., & Auer, A. I. (1995) · Critical Care Medicine · doi:10.1097/00003246-199501000-00011 · Cited by 224
Calvert, N., Hind, D., McWilliams, R. G., Thomas, S., Beverley, C., & Davidson, A. (2003) · Health Technology Assessment · doi:10.3310/hta7120 · Cited by 133
Self-citation
Cited by
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Moore, C. L., & Copel, J. A. (2011) · New England Journal of Medicine · doi:10.1056/nejmra0909487 · Cited by 1,788
Loveday, H. P., Wilson, J. A., Pratt, R. J., Golsorkhi, M., Tingle, A., Bak, A., Browne, J., Prieto, J., & Wilcox, M. (2014) · Journal of Hospital Infection · doi:10.1016/s0195-6701(13)60012-2 · Cited by 1,621
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
“pared with the standard landmark placement [60, 61].”
International evidence-based recommendations on ultrasound-guided vascular access
Lamperti, M., Bodenham, A. R., Pittiruti, M., Blaivas, M., Augoustides, J. G., Elbarbary, M., Pirotte, T., Karakitsos, D., LeDonne, J., Doniger, S., et al. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2597-x · Cited by 834
Pittiruti, M., Hamilton, H., Biffi, R., MacFie, J., & Pertkiewicz, M. (2009) · Clinical Nutrition · doi:10.1016/j.clnu.2009.03.015 · Cited by 698
Davis, A. L., Carcillo, J. A., Aneja, R. K., Deymann, A. J., Lin, J. C., Nguyen, T. C., Okhuysen-Cawley, R. S., Relvas, M. S., Rozenfeld, R. A., Skippen, P. W., et al. (2017) · Critical Care Medicine · doi:10.1097/ccm.0000000000002425 · Cited by 670
Singh, Y., Tissot, C., Fraga, M. V., Yousef, N., Cortes, R. G., Lopez, J., Sanchez-de-Toledo, J., Brierley, J., Colunga, J. M., Raffaj, D., et al. (2020) · Critical Care · doi:10.1186/s13054-020-2787-9 · Cited by 659
Guidelines for the use of platelet transfusions
Estcourt, L. J., Birchall, J., Allard, S., Bassey, S. J., Hersey, P., Kerr, J. P., Mumford, A. D., Stanworth, S. J., Tinegate, H., & the British Committee for Standards in Haematology (2017) · British Journal of Haematology · doi:10.1111/bjh.14423 · Cited by 648
Infusion Nursing Standards of Practice
Gorski, L. A. (2007) · Journal of Infusion Nursing · doi:10.1097/01.nan.0000270673.13439.95 · Cited by 602
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir138 · Cited by 560
Marschall, J., Mermel, L. A., Fakih, M., Hadaway, L., Kallen, A., O’Grady, N. P., Pettis, A. M., Rupp, M. E., Sandora, T., Maragakis, L. L., et al. (2014) · Infection Control & Hospital Epidemiology · doi:10.1086/676533 · Cited by 550
Frankel, H. L., Kirkpatrick, A. W., Elbarbary, M., Blaivas, M., Desai, H., Evans, D., Summerfield, D. T., Slonim, A., Breitkreutz, R., Price, S., et al. (2015) · Critical Care Medicine · doi:10.1097/ccm.0000000000001216 · Cited by 494
Real-Time Ultrasound Guidance Facilitates Femoral Arterial Access and Reduces Vascular Complications
Seto, A. H., Abu-Fadel, M. S., Sparling, J. M., Zacharias, S. J., Daly, T. S., Harrison, A. T., Suh, W. M., Vera, J. A., Aston, C. E., Winters, R. J., et al. (2010) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2010.04.015 · Cited by 484
Ultrasound guidance versus anatomical landmarks for internal jugular vein catheterization
Brass, P., Hellmich, M., Kolodziej, L., Schick, G., & Smith, A. F. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006962.pub2 · Cited by 476
Buetti, N., Marschall, J., Drees, M., Fakih, M. G., Hadaway, L., Maragakis, L. L., Monsees, E., Novosad, S., O’Grady, N. P., Rupp, M. E., et al. (2022) · Infection Control & Hospital Epidemiology · doi:10.1017/ice.2022.87 · Cited by 475
Bleeding Complications of Native Kidney Biopsy: A Systematic Review and Meta-analysis
Corapi, K. M., Chen, J. L. T., Balk, E. M., & Gordon, C. E. (2012) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2012.02.330 · Cited by 436
Troianos, C. A., Hartman, G. S., Glas, K. E., Skubas, N. J., Eberhardt, R. T., Walker, J. D., & Reeves, S. T. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.09.021 · Cited by 420
2019 EACTS Expert Consensus on long-term mechanical circulatory support
Potapov, E. V., Antonides, C., Crespo-Leiro, M. G., Combes, A., Färber, G., Hannan, M. M., Kukucka, M., de Jonge, N., Loforte, A., Lund, L. H., et al. (2019) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezz098 · Cited by 399
Leung, J., Duffy, M., & Finckh, A. (2006) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.01.011 · Cited by 342
Milling, T. J., Rose, J., Briggs, W. M., Birkhahn, R., Gaeta, T. J., Bove, J. J., & Melniker, L. A. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000171533.92856.e5 · Cited by 334
Complications of Central Venous Catheterization
Kusminsky, R. E. (2007) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2007.01.039 · Cited by 330
Firstenberg, M., Kornbau, C., Lee, K., & Hughes, G. (2015) · International Journal of Critical Illness and Injury Science · doi:10.4103/2229-5151.164940 · Cited by 327
Ultrasound guidance versus anatomical landmarks for subclavian or femoral vein catheterization
Brass, P., Hellmich, M., Kolodziej, L., Schick, G., & Smith, A. F. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011447 · Cited by 320
Guidelines for the Prevention of Intravascular Catheter–Related Infections
O'Grady, N. P., Alexander, M., Dellinger, E. P., Gerberding, J. L., Heard, S. O., Maki, D. G., Masur, H., McCormick, R. D., Mermel, L. A., Pearson, M. L., et al. (2002) · Infection Control & Hospital Epidemiology · doi:10.1017/s0195941700080577 · Cited by 319
Pneumothorax Following Thoracentesis: A Systematic Review and Meta-analysis
Gordon, C. E. (2010) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.548 · Cited by 306
Vascular Access in Oncology Patients
Gallieni, M., Pittiruti, M., & Biffi, R. (2008) · CA: A Cancer Journal for Clinicians · doi:10.3322/ca.2008.0015 · Cited by 284
Guidelines on the insertion and management of central venous access devices in adults
BISHOP, L., DOUGHERTY, L., BODENHAM, A., MANSI, J., CROWE, P., KIBBLER, C., SHANNON, M., & TRELEAVEN, J. (2007) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2007.00931.x · Cited by 264
Franco‐Sadud, R., Schnobrich, D., Mathews, B. K., Candotti, C., Abdel‐Ghani, S., Perez, M. G., Rodgers, S. C., Mader, M. J., Haro, E. K., Dancel, R., et al. (2019) · Journal of Hospital Medicine · doi:10.12788/jhm.3287 · Cited by 260
Froehlich, C. D., Rigby, M. R., Rosenberg, E. S., Li, R., Roerig, P.-L. J., Easley, K. A., & Stockwell, J. A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e31819b570e · Cited by 250
“88 in the US group) also demonstrated improved success for US-guided IJ CVC placement (10).”
BackgroundBiffi, R., Orsi, F., Pozzi, S., Pace, U., Bonomo, G., Monfardini, L., Della Vigna, P., Rotmensz, N., Radice, D., Zampino, M. G., et al. (2009) · Annals of Oncology · doi:10.1093/annonc/mdn701 · Cited by 236
“[23] concluded that the use of US reduced failure rate—both overall and on the first insertion attempt—and also placement-related complications when compared with landmark technique.”
BackgroundResultUltrasound guidance for difficult peripheral venous access: Systematic review and meta-analysis
Egan, G., Healy, D., O'Neill, H., Clarke-Moloney, M., Grace, P. A., & Walsh, S. R. (2013) · Emergency Medicine Journal · doi:10.1136/emermed-2012-201652 · Cited by 222
“Of note, it is also important that providers are still trained and experienced in the standard technique as there is a potential to deskill people, which becomes especially pertinent when using it to gain peripheral or central venous access in an emergency setting when Ultrasound is not available.(8)”
BackgroundUltrasound-Guided Catheterization of the Radial Artery
Shiloh, A. L., Savel, R. H., Paulin, L. M., & Eisen, L. A. (2011) · Chest · doi:10.1378/chest.10-0919 · Cited by 208
van Loon, F. H. J., Buise, M. P., Claassen, J. J. F., Dierick-van Daele, A. T. M., & Bouwman, A. R. A. (2018) · British Journal of Anaesthesia · doi:10.1016/j.bja.2018.04.047 · Cited by 195
Pediatric emergency medicine point-of-care ultrasound: summary of the evidence
Marin, J. R., Abo, A. M., Arroyo, A. C., Doniger, S. J., Fischer, J. W., Rempell, R., Gary, B., Holmes, J. F., Kessler, D. O., Lam, S. H. F., et al. (2016) · Critical Ultrasound Journal · doi:10.1186/s13089-016-0049-5 · Cited by 190
“When compared with the landmark method, ultrasound guidance was shown to have a lower overall and first attempt failure rate [410].”
ResultCentral Venous Catheterization
Graham, A. S., Ozment, C., Tegtmeyer, K., Lai, S., & Braner, D. A. V. (2007) · New England Journal of Medicine · doi:10.1056/nejmvcm055053 · Cited by 163
Renal replacement therapy in adult and pediatric intensive care
Vinsonneau, C., Allain-Launay, E., Blayau, C., Darmon, M., du Cheyron, D., Gaillot, T., Honore, P. M., Javouhey, E., Krummel, T., Lahoche, A., et al. (2015) · Annals of Intensive Care · doi:10.1186/s13613-015-0093-5 · Cited by 151
“By guiding insertion in the vein and detecting anatomical variations, ultrasound improves the success rate and patient comfort, and reduces the time needed for placement, the number of attempts per insertion, the number of complications and cost [51–53].”
BackgroundUltrasound Guidance Facilitates Radial Artery Catheterization
Gu, W.-J., Wu, X.-D., Wang, F., Ma, Z.-L., & Gu, X.-P. (2016) · Chest · doi:10.1378/chest.15-1784 · Cited by 109
Real-Time Detection of Infusion Site Failures in a Closed-Loop Artificial Pancreas
Howsmon, D. P., Baysal, N., Buckingham, B. A., Forlenza, G. P., Ly, T. T., Maahs, D. M., Marcal, T., Towers, L., Mauritzen, E., Deshpande, S., et al. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818755173 · Cited by 32
Metadata
- Authors
- Hind, D., Calvert, N., McWilliams, R., Davidson, A., Paisley, S., Beverley, C., & Thomas, S.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2003-08-14
- Volume
- 327
- Issue
- 7411
- Pages
- 361
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W2068072205
- Cited by
- 1,090
- References
- 6
- FWCI
- 44.35
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.