The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Blood pressure control by home monitoring: meta-analysis of randomised trials
Open accessAbstract
OBJECTIVE: To determine the effect of home blood pressure monitoring on blood pressure levels and proportion of people with essential hypertension achieving targets. DESIGN: Meta-analysis of 18 randomised controlled trials. PARTICIPANTS: 1359 people with essential hypertension allocated to home blood pressure monitoring and 1355 allocated to the "control" group seen in the healthcare system for 2-36 months. MAIN OUTCOME MEASURES: Differences in systolic (13 studies), diastolic (16 studies), or mean (3 studies) blood pressures, and proportion of patients achieving targets (6 studies), between intervention and control groups. RESULTS: Systolic blood pressure was lower in people with hypertension who had home blood pressure monitoring than in those who had standard blood pressure monitoring in the healthcare system (standardised mean difference 4.2 (95% confidence interval 1.5 to 6.9) mm Hg), diastolic blood pressure was lower by 2.4 (1.2 to 3.5) mm Hg, and mean blood pressure was lower by 4.4 (2.0 to 6.8) mm Hg. The relative risk of blood pressure above predetermined targets was lower in people with home blood pressure monitoring (risk ratio 0.90, 0.80 to 1.00). When publication bias was allowed for, the differences were attenuated: 2.2 (-0.9 to 5.3) mm Hg for systolic blood pressure and 1.9 (0.6 to 3.2) mm Hg for diastolic blood pressure. CONCLUSIONS: Blood pressure control in people with hypertension (assessed in the clinic) and the proportion achieving targets are increased when home blood pressure monitoring is used rather than standard blood pressure monitoring in the healthcare system. The reasons for this are not clear. The difference in blood pressure control between the two methods is small but likely to contribute to an important reduction in vascular complications in the hypertensive population.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Chobanian, A. V. (2003) · JAMA · doi:10.1001/jama.289.19.2560 · Cited by 25,386
Blood pressure, stroke, and coronary heart disease
Collins, R., Peto, R., MacMahon, S., Godwin, J., Qizilbash, N., Collins, R., MacMahon, S., Hebert, P., Eberlein, K. A., Taylor, J. O., et al. (1990) · The Lancet · doi:10.1016/0140-6736(90)90944-z · Cited by 4,491
Chobanian, A. V., Bakris, G. L., Black, H. R., Cushman, W. C., Green, L. A., Izzo, J. L., Jones, D. W., Materson, B. J., Oparil, S., Wright, J. T., et al. (2003) · Evidence-Based Eye Care · doi:10.1097/00132578-200307000-00027 · Cited by 1,793
Empirical assessment of effect of publication bias on meta-analyses
Sutton, A. J. (2000) · BMJ · doi:10.1136/bmj.320.7249.1574 · Cited by 1,398
Williams, B., Poulter, N. R., Brown, M. J., Davis, M., McInnes, G. T., Potter, J. F., Sever, P. S., & McG Thom, S. (2004) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001683 · Cited by 1,272
(1995) · The Lancet · doi:10.1016/s0140-6736(95)92836-7 · Cited by 856
IMPROVEMENT OF MEDICATION COMPLIANCE IN UNCONTROLLED HYPERTENSION
Haynes, R. B., Gibson, E., Hackett, B., Sackett, D., Taylor, D. W., Roberts, R., & Johnson, A. (1976) · The Lancet · doi:10.1016/s0140-6736(76)91737-2 · Cited by 513
Friedman, R. (1996) · American Journal of Hypertension · doi:10.1016/0895-7061(95)00353-3 · Cited by 510
Staessen, J. A. (2004) · JAMA · doi:10.1001/jama.291.8.955 · Cited by 288
Modelling publication bias in meta-analysis: a review
Sutton, A. J., Song, F., Gilbody, S. M., & Abrams, K. R. (2000) · Statistical Methods in Medical Research · doi:10.1177/096228020000900503 · Cited by 288
Improved Hypertension Management and Control: Results From the Health Survey for England 1998
Primatesta, P., Brookes, M., & Poulter, N. R. (2001) · Hypertension · doi:10.1161/hyp.38.4.827 · Cited by 276
Rogers, M. A. M., Small, D., Buchan, D. A., Butch, C. A., Stewart, C. M., Krenzer, B. E., & Husovsky, H. L. (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-134-11-200106050-00008 · Cited by 246
Mehos, B. M., Saseen, J. J., & MacLaughlin, E. J. (2000) · Pharmacotherapy: The Journal of Human Pharmacology and Drug Therapy · doi:10.1592/phco.20.17.1384.34891 · Cited by 183
Home blood pressure monitoring. Effect on use of medical services and medical care costs.
Soghikian, K., Casper, S. M., FIREMAN, B. H., Hunkeler, E. M., Hurley, L. B., Tekawa, I. S., & VOGT, T. M. (1992) · PubMed · Cited by 174
Little, P., Barnett, J., Barnsley, L., Marjoram, J., Fitzgerald-Barron, A., & Mant, D. (2002) · BMJ · doi:10.1136/bmj.325.7358.254 · Cited by 171
Little, P., Barnett, J., Barnsley, L., Marjoram, J., Fitzgerald-Barron, A., & Mant, D. (2002) · BMJ · doi:10.1136/bmj.325.7358.258 · Cited by 168
Artinian, N. T., Washington, O. G. M., & Templin, T. N. (2001) · Heart & Lung · doi:10.1067/mhl.2001.112684 · Cited by 161
Zarnke, K. B., Feagan, B. G., Mahon, J. L., & Feldman, R. D. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(96)00305-6 · Cited by 156
Home Blood Pressure Monitoring
Yarows, S. A., Julius, S., & Pickering, T. G. (2000) · Archives of Internal Medicine · doi:10.1001/archinte.160.9.1251 · Cited by 149
Case-control study of stroke and the quality of hypertension control in north west England
Du, X. L., Cruickshank, K. J., McNamee, R., Saraee, M., Sourbutts, J., Summers, A., Roberts, N., Walton, E., & Holmes, S. (1997) · BMJ · doi:10.1136/bmj.314.7076.272 · Cited by 119
Self-recording of blood pressure in the management of hypertension.
Johnson, A. L., Taylor, D. W., Sackett, D. L., Dunnett, C. W., & Shimizu, A. (1978) · PubMed Central · Cited by 118
The effects of self-monitoring by patients on the control of hypertension
CARNAHAN, J. E., & Nugent, C. A. (1975) · The American Journal of the Medical Sciences · doi:10.1097/00000441-197501000-00008 · Cited by 98
Antenatal home blood pressure monitoring: a pilot randomised controlled trial
Ross‐McGill, H., Hewison, J., Hirst, J., Dowswell, T., Holt, A., Brunskill, P., & Thornton, J. G. (2000) · BJOG: An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2000.tb11692.x · Cited by 87
The effects of family involvement and practitioner home visits on the control of hypertension.
Earp, J. A., Ory, M. G., & Strogatz, D. S. (1982) · American Journal of Public Health · doi:10.2105/ajph.72.10.1146 · Cited by 81
Management of hypertension in the elderly using home blood pressures
Broege, P. A., James, G. D., & Pickering, T. G. (2001) · Blood Pressure Monitoring · doi:10.1097/00126097-200106000-00004 · Cited by 77
Reliability of patients measuring blood pressure at home: prospective observational study
Nordmann, A. J., Frach, B., Walker, T., Martina, B., & Battegay, E. (1999) · BMJ · doi:10.1136/bmj.319.7218.1172 · Cited by 74
Evaluation of a structured treatment and teaching programme on hypertension in general practice
Mühlhauser, I., Sawicki, P. T., Didjurgeit, U., Jörgens, V., Trampisch, H. J., & Berger, M. (1993) · Clinical and Experimental Hypertension · doi:10.3109/10641969309041615 · Cited by 71
Effects of home blood pressure measurement on long-term BP control.
Stahl, S. M., Kelley, C. R., Neill, P. J., Grim, C. E., & Mamlin, J. J. (1984) · American Journal of Public Health · doi:10.2105/ajph.74.7.704 · Cited by 57
A controlled trial of health education in the physician's office
Pierce, J. P., Watson, D. S., Knights, S., Gliddon, T., Williams, S., & Watson, R. (1984) · Preventive Medicine · doi:10.1016/0091-7435(84)90050-1 · Cited by 50
A Comparison of Compliance Techniques on the Control of High Blood Pressure
Binstock, M., & Franklin, K. (1988) · American Journal of Hypertension · doi:10.1093/ajh/1.3.192s · Cited by 45
Home blood pressure monitoring for mild hypertensives.
Midanik, L. T., RESNICK, B. D., Lb, H., Ej, S., & McCarthy, M. (1991) · Europe PMC (PubMed Central) · Cited by 41
Antihypertensive drug treatment: A comparison of usual care with self blood pressure measurement
Bailey, B., Carney, S., Gillies, A. H. B., & Smith, A. J. (1999) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000758 · Cited by 37
Home blood pressure monitoring: its effect on the management of hypertension in general practice.
Aylett, M., Marples, G., & Jones, K. (1999) · PubMed Central · Cited by 33
Vetter, W., Hess, L., & Brignoli, R. (2000) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1000977 · Cited by 32
Brueren, M., Schouten, H. J. A., de Leeuw, P. W., van Montfrans, G. A., & van Ree, J. W. (1998) · Europe PMC (PubMed Central) · Cited by 29
The role of home blood pressure measurement in managing hypertension: an evidence-based review
Rickerby, J. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001423 · Cited by 29
How to use home blood pressure monitors in clinical practice
Yarows, S. A., & Staessen, J. A. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02277-4 · Cited by 26
Cartwright, W., Dalton, K., Swindells, H. E., Rushant, S., & MOONEY, P. (1992) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.1992.tb14495.x · Cited by 21
Rogers, M. A. M., Small, D., Buchan, D. A., Butch, C. A., Stewart, C. M., Krenzer, B. E., & Husovsky, H. L. (2001) · Circulation · doi:10.1161/circ.103.suppl_1.9998-99 · Cited by 21
Antenatal home blood pressure monitoring: a pilot randomised controlled trial
Waugh, J. J. S., Halligan, A., & Shennan, A. H. (2000) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2000.tb11128.x · Cited by 10
Rogers, M. A. M., Small, D., Buchan, D. A., Butch, C. A., Stewart, C. M., Krenzer, B. E., & Husovsky, H. L. (2001) · Circulation · doi:10.1161/01.cir.103.suppl_1.1369-e · Cited by 9
Cited by
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Olsen, M. H., Angell, S. Y., Asma, S., Boutouyrie, P., Burger, D., Chirinos, J. A., Damasceno, A., Delles, C., Gimenez-Roqueplo, A.-P., Hering, D., et al. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31134-5 · Cited by 939
Assessment and management of blood-pressure variability
Parati, G., Ochoa, J. E., Lombardi, C., & Bilo, G. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.1 · Cited by 853
Parati, G., Stergiou, G. S., Asmar, R., Bilo, G., de Leeuw, P., Imai, Y., Kario, K., Lurbe, E., Manolis, A., Mengden, T., et al. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e328308da66 · Cited by 837
Meta-analysis: chronic disease self-management programs for older adults
Chodosh, J., Morton, S. C., Mojica, W., Maglione, M., Suttorp, M. J., Hilton, L., Rhodes, S., & Shekelle, P. (2005) · Annals of Internal Medicine · doi:10.7326/0003-4819-143-6-200509200-00007 · Cited by 790
Metadata
- Authors
- Cappuccio, F. P., Kerry, S. M., Forbes, L., & Donald, A.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2004-06-11
- Volume
- 329
- Issue
- 7458
- Pages
- 145
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W1971948961
- Cited by
- 509
- References
- 45
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.