CoChat

Screening for colorectal cancer: randomised trial comparing guaiac-based and immunochemical faecal occult blood testing and flexible sigmoidoscopy

Hol, L, van Leerdam, M E, van Ballegooijen, M, van Vuuren, A J, van Dekken, H, Reijerink, J C I Y, van der Togt, A C M, Habbema, J D F, Kuipers, E J · 2010 · Gut
Cited by 481

The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.

Abstract

Background: Screening for colorectal cancer (CRC) is widely accepted, but there is no consensus on the preferred strategy. We conducted a randomised trial comparing participation and detection rates (DR) per screenee of guaiac-based faecal occult blood test (gFOBT), immunochemical FOBT (FIT), and flexible sigmoidoscopy (FS) for CRC screening. Methods: A representative sample of the Dutch population (n = 15 011), aged 50–74 years, was 1:1:1 randomised prior to invitation to one of the three screening strategies. Colonoscopy was indicated for screenees with a positive gFOBT or FIT, and for those in whom FS revealed a polyp with a diameter ⩾10 mm; adenoma with ⩾25% villous component or high grade dysplasia; serrated adenoma; ⩾3 adenomas; ⩾20 hyperplastic polyps; or CRC. Results: The participation rate was 49.5% (95% confidence interval (CI) 48.1 to 50.9%) for gFOBT, 61.5% (CI, 60.1 to 62.9%) for FIT and 32.4% (CI, 31.1 to 33.7%) for FS screening. gFOBT was positive in 2.8%, FIT in 4.8% and FS in 10.2%. The DR of advanced neoplasia was significantly higher in the FIT (2.4%; OR, 2.0; CI, 1.3 to 3.1) and the FS arm (8.0%; OR, 7.0; CI, 4.6 to 10.7) than the gFOBT arm (1.1%). FS demonstrated a higher diagnostic yield of advanced neoplasia per 100 invitees (2.4; CI, 2.0 to 2.8) than gFOBT (0.6; CI, 0.4 to 0.8) or FIT (1.5; CI, 1.2 to 1.9) screening. Conclusion: This randomised population-based CRC-screening trial demonstrated superior participation and detection rates for FIT compared to gFOBT screening. FIT screening should therefore be strongly preferred over gFOBT screening. FS screening demonstrated a higher diagnostic yield per 100 invitees than both FOBTs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gut.2009.177089

Cites

26 of 26 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 26 references

Cited by

Metadata

Authors
Hol, L., van Leerdam, M. E., van Ballegooijen, M., van Vuuren, A. J., van Dekken, H., Reijerink, J. C. I. Y., van der Togt, A. C. M., Habbema, J. D. F., & Kuipers, E. J.
Venue
Gut
Publisher
BMJ
Published
2009-08-10
Volume
59
Issue
01
Pages
62-68
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W2113414502
Cited by
481
References
26
FWCI
18.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.