Diaphragm ultrasound as a predictor of successful extubation from mechanical ventilation
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: The purpose of this study was to evaluate if ultrasound derived measures of diaphragm thickening, rather than diaphragm motion, can be used to predict extubation success or failure. METHODS: Sixty-three mechanically ventilated patients were prospectively recruited. Diaphragm thickness (tdi) was measured in the zone of apposition of the diaphragm to the rib cage using a 7-10 MHz ultrasound transducer. The percent change in tdi between end-expiration and end-inspiration (Δtdi%) was calculated during either spontaneous breathing (SB) or pressure support (PS) weaning trials. A successful extubation was defined as SB for >48 h following endotracheal tube removal. RESULTS: Of the 63 subjects studied, 27 patients were weaned with SB and 36 were weaned with PS. The combined sensitivity and specificity of Δtdi%≥30% for extubation success was 88% and 71%, respectively. The positive predictive value and negative predictive value were 91% and 63%, respectively. The area under the receiver operating characteristic curve was 0.79 for Δtdi%. CONCLUSIONS: Ultrasound measures of diaphragm thickening in the zone of apposition may be useful to predict extubation success or failure during SB or PS trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Esteban, A. (2002) · JAMA · doi:10.1001/jama.287.3.345 · Cited by 1,779
Rapid Disuse Atrophy of Diaphragm Fibers in Mechanically Ventilated Humans
Levine, S., Nguyen, T., Taylor, N., Friscia, M. E., Budak, M. T., Rothenberg, P., Zhu, J., Sachdeva, R., Sonnad, S., Kaiser, L. R., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa070447 · Cited by 1,577
Yang, K. L., & Tobin, M. J. (1991) · New England Journal of Medicine · doi:10.1056/nejm199105233242101 · Cited by 1,378
Matamis, D., Soilemezi, E., Tsagourias, M., Akoumianaki, E., Dimassi, S., Boroli, F., Richard, J.-C. M., & Brochard, L. (2013) · Intensive Care Medicine · doi:10.1007/s00134-013-2823-1 · Cited by 576
Diaphragm dysfunction assessed by ultrasonography: Influence on weaning from mechanical ventilation*
Kim, W. Y., Suh, H. J., Hong, S.-B., Koh, Y., & Lim, C.-M. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182266408 · Cited by 550
McCool, F. D., & Tzelepis, G. E. (2012) · New England Journal of Medicine · doi:10.1056/nejmra1007236 · Cited by 489
Self-citationUltrasound evaluation of the paralyzed diaphragm.
Gottesman, E., & McCool, F. D. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.5.9154859 · Cited by 353
Self-citationUltrasonographic evaluation of diaphragmatic motion.
Gerscovich, E. O., Cronan, M., McGahan, J. P., Jain, K., Jones, C. D., & McDonald, C. (2001) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2001.20.6.597 · Cited by 312
Diaphragm Muscle Thinning in Patients Who Are Mechanically Ventilated
Grosu, H. B., Lee, Y. I., Lee, J., Eden, E., Eikermann, M., & Rose, K. M. (2012) · Chest · doi:10.1378/chest.11-1638 · Cited by 281
Incidence and outcome of weaning from mechanical ventilation according to new categories
Funk, G.-C., Anders, S., Breyer, M.-K., Burghuber, O. C., Edelmann, G., Heindl, W., Hinterholzer, G., Kohansal, R., Schuster, R., Schwarzmaier-D'Assie, A., et al. (2010) · European Respiratory Journal · doi:10.1183/09031936.00056909 · Cited by 274
Cited by
ERS statement on respiratory muscle testing at rest and during exercise
Laveneziana, P., Albuquerque, A., Aliverti, A., Babb, T., Barreiro, E., Dres, M., Dubé, B.-P., Fauroux, B., Gea, J., Guenette, J. A., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01214-2018 · Cited by 818
Mechanical Ventilation–induced Diaphragm Atrophy Strongly Impacts Clinical Outcomes
Goligher, E. C., Dres, M., Fan, E., Rubenfeld, G. D., Scales, D. C., Herridge, M. S., Vorona, S., Sklar, M. C., Rittayamai, N., Lanys, A., et al. (2018) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201703-0536oc · Cited by 813
Evolution of Diaphragm Thickness during Mechanical Ventilation. Impact of Inspiratory Effort
Goligher, E. C., Fan, E., Herridge, M. S., Murray, A., Vorona, S., Brace, D., Rittayamai, N., Lanys, A., Tomlinson, G., Singh, J. M., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201503-0620oc · Cited by 608
Goligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Sebastien-Bolz, S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3687-3 · Cited by 448
Critical illness-associated diaphragm weakness
Dres, M., Goligher, E. C., Heunks, L. M. A., & Brochard, L. J. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4928-4 · Cited by 402
Zambon, M., Greco, M., Bocchino, S., Cabrini, L., Beccaria, P. F., & Zangrillo, A. (2017) · Intensive Care Medicine · doi:10.1007/s00134-016-4524-z · Cited by 386
Umbrello, M., Formenti, P., Longhi, D., Galimberti, A., Piva, I., Pezzi, A., Mistraletti, G., Marini, J. J., & Iapichino, G. (2015) · Critical Care · doi:10.1186/s13054-015-0894-9 · Cited by 343
“Thickening during active breathing has been proposed to reflect the magnitude of diaphragmatic effort, similarly to an ejection fraction of the heart [16].”
BackgroundJung, B., Moury, P. H., Mahul, M., de Jong, A., Galia, F., Prades, A., Albaladejo, P., Chanques, G., Molinari, N., & Jaber, S. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4125-2 · Cited by 330
Goligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Bolz, S.-S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3724-2 · Cited by 315
Tuinman, P. R., Jonkman, A. H., Dres, M., Shi, Z.-H., Goligher, E. C., Goffi, A., de Korte, C., Demoule, A., & Heunks, L. (2020) · Intensive Care Medicine · doi:10.1007/s00134-019-05892-8 · Cited by 292
Diaphragm and Lung Ultrasound to Predict Weaning Outcome
Llamas-Álvarez, A. M., Tenza-Lozano, E. M., & Latour-Pérez, J. (2017) · Chest · doi:10.1016/j.chest.2017.08.028 · Cited by 243
Diaphragm Dysfunction: Diagnostic Approaches and Management Strategies
Dubé, B.-P., & Dres, M. (2016) · Journal of Clinical Medicine · doi:10.3390/jcm5120113 · Cited by 230
“In contrast, TFdi has been shown to be correlated to the pressure-generating capacity of the diaphragm [58,128], to the work of breathing and respiratory effort [118,129] and can be used as a valid tool to identify diaphragm dysfunction [130,131], monitor its temporal changes [29,125] and may predict weaning outcomes…”
BackgroundMethodDiaphragm Muscle Fiber Weakness and Ubiquitin–Proteasome Activation in Critically Ill Patients
Hooijman, P. E., Beishuizen, A., Witt, C. C., de Waard, M. C., Girbes, A. R. J., Spoelstra-de Man, A. M. E., Niessen, H. W. M., Manders, E., van Hees, H. W. H., van den Brom, C. E., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201412-2214oc · Cited by 229
Ricoy, J., Rodríguez-Núñez, N., Álvarez-Dobaño, J. M., Toubes, M. E., Riveiro, V., & Valdés, L. (2019) · Pulmonology · doi:10.1016/j.pulmoe.2018.10.008 · Cited by 228
Dubé, B.-P., Dres, M., Mayaux, J., Demiri, S., Similowski, T., & Demoule, A. (2017) · Thorax · doi:10.1136/thoraxjnl-2016-209459 · Cited by 216
Haaksma, M. E., Smit, J. M., Boussuges, A., Demoule, A., Dres, M., Ferrari, G., Formenti, P., Goligher, E. C., Heunks, L., Lim, E. H. T., et al. (2022) · Critical Care · doi:10.1186/s13054-022-03975-5 · Cited by 205
Robba, C., Wong, A., Poole, D., Al Tayar, A., Arntfield, R. T., Chew, M. S., Corradi, F., Douflé, G., Goffi, A., Lamperti, M., et al. (2021) · Intensive Care Medicine · doi:10.1007/s00134-021-06486-z · Cited by 199
“2014 [28] 8 fellows Critical care Yes 6 h/6 h – No Cardiac US: increase of mean knowledge assessment score from 58 to 86% (p = 0.”
BackgroundSchepens, T., Verbrugghe, W., Dams, K., Corthouts, B., Parizel, P. M., & Jorens, P. G. (2015) · Critical Care · doi:10.1186/s13054-015-1141-0 · Cited by 193
“Diaphragm thickening, defined as recording the difference between inspiration and expiration in B- or M-mode, could serve as a novel parameter to predict weaning and extubation success [21, 22].”
BackgroundInability of Diaphragm Ultrasound to Predict Extubation Failure
Vivier, E., Muller, M., Putegnat, J.-B., Steyer, J., Barrau, S., Boissier, F., Bourdin, G., Mekontso-Dessap, A., Levrat, A., Pommier, C., et al. (2019) · Chest · doi:10.1016/j.chest.2019.03.004 · Cited by 179
Spadaro, S., Grasso, S., Mauri, T., Dalla Corte, F., Alvisi, V., Ragazzi, R., Cricca, V., Biondi, G., Di Mussi, R., Marangoni, E., et al. (2016) · Critical Care · doi:10.1186/s13054-016-1479-y · Cited by 163
“We chose, on the basis of other reports [49, 50], not to measure the left hemidiaphragm displacement because the spleen offers a small acoustic window and because gastric or colic meteorism often impairs diaphragmatic imaging on the left side.”
MethodResultFarghaly, S., & Hasan, A. A. (2017) · Australian Critical Care · doi:10.1016/j.aucc.2016.03.004 · Cited by 159
A wearable echomyography system based on a single transducer
Gao, X., Chen, X., Lin, M., Yue, W., Hu, H., Qin, S., Zhang, F., Lou, Z., Yin, L., Huang, H., et al. (2024) · Nature Electronics · doi:10.1038/s41928-024-01271-4 · Cited by 95
“The EcMG system allows for continuous monitoring, potentially enabling doctors to determine the best timing for extubating patients with greater precision and thus better patient experience and treat-ment outcomes 32,54,55 .”
Metadata
- Authors
- DiNino, E., Gartman, E. J., Sethi, J. M., & McCool, F. D.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 2013-12-23
- Volume
- 69
- Issue
- 5
- Pages
- 431-435
- ISSN
- 0040-6376 (ISSN-L)
- 1468-3296
- OpenAlex
- W2155913350
- Cited by
- 487
- References
- 24
- FWCI
- 14.13
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.