Ultrasound evaluation of diaphragm function in mechanically ventilated patients: comparison to phrenic stimulation and prognostic implications
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Rationale In intensive care unit (ICU) patients, diaphragm dysfunction is associated with adverse clinical outcomes. Ultrasound measurements of diaphragm thickness, excursion (EXdi) and thickening fraction (TFdi) are putative estimators of diaphragm function, but have never been compared with phrenic nerve stimulation. Our aim was to describe the relationship between these variables and diaphragm function evaluated using the change in endotracheal pressure after phrenic nerve stimulation (Ptr,stim), and to compare their prognostic value. Methods Between November 2014 and June 2015, Ptr,stim and ultrasound variables were measured in mechanically ventilated patients <24 hours after intubation (‘initiation of mechanical ventilation (MV)’, under assist-control ventilation, ACV) and at the time of switch to pressure support ventilation (‘switch to PSV’), and compared using Spearman9s correlation and receiver operating characteristic curve analysis. Diaphragm dysfunction was defined as Ptr,stim <11 cm H2O. Results 112 patients were included. At initiation of MV, Ptr,stim was not correlated to diaphragm thickness (p=0.28), EXdi (p=0.66) or TFdi (p=0.80). At switch to PSV, TFdi and EXdi were respectively very strongly and moderately correlated to Ptr,stim, (r=0.87, p<0.001 and 0.45, p=0.001), but diaphragm thickness was not (p=0.45). A TFdi <29% could reliably identify diaphragm dysfunction (sensitivity and specificity of 85% and 88%), but diaphragm thickness and EXdi could not. This value was associated with increased duration of ICU stay and MV, and mortality. Conclusions Under ACV, diaphragm thickness, EXdi and TFdi were uncorrelated to Ptr,stim. Under PSV, TFdi was strongly correlated to diaphragm strength and both were predictors of remaining length of MV and ICU and hospital death.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2001 SCCM/ESICM/ACCP/ATS/SIS International Sepsis Definitions Conference
Conference, F. T. I. S. D., Levy, M. M., Fink, M. P., Marshall, J. C., Abraham, E., Angus, D., Cook, D., Cohen, J., Opal, S. M., Vincent, J.-L., et al. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1662-x · Cited by 2,871
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
Rapid Disuse Atrophy of Diaphragm Fibers in Mechanically Ventilated Humans
Levine, S., Nguyen, T., Taylor, N., Friscia, M. E., Budak, M. T., Rothenberg, P., Zhu, J., Sachdeva, R., Sonnad, S., Kaiser, L. R., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa070447 · Cited by 1,577 · cited 1×
“19 The inspiratory thickening of the diaphragm has been more extensively correlated with relevant outcomes such as weaning failure and has been proposed as a dynamic marker of diaphragm function.”
BackgroundRapidly Progressive Diaphragmatic Weakness and Injury during Mechanical Ventilation in Humans
Jaber, S., Petrof, B. J., Jung, B., Chanques, G., Berthet, J.-P., Rabuel, C., Bouyabrine, H., Courouble, P., Koechlin-Ramonatxo, C., Sebbane, M., et al. (2011) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201004-0670oc · Cited by 709 · cited 1×
“In a cohort of critically ill, mechanically ventilated patients, we found no signi fi cant relationship between diaphragm thickness and its contractile capacity, suggesting that diaphragm thickness should not be used as an estimator of diaphragm contractility in the ICU setting.”
BackgroundSelf-citationEvolution of Diaphragm Thickness during Mechanical Ventilation. Impact of Inspiratory Effort
Goligher, E. C., Fan, E., Herridge, M. S., Murray, A., Vorona, S., Brace, D., Rittayamai, N., Lanys, A., Tomlinson, G., Singh, J. M., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201503-0620oc · Cited by 608 · cited 2×
“In a study investigating the evolution of diaphragm thickness of critically ill patients during their fi rst week of MV, 18 low diaphragm contractile activity (estimated using TFdi) was associated with both a decline and an increase in diaphragm thickness.”
MethodMatamis, D., Soilemezi, E., Tsagourias, M., Akoumianaki, E., Dimassi, S., Boroli, F., Richard, J.-C. M., & Brochard, L. (2013) · Intensive Care Medicine · doi:10.1007/s00134-013-2823-1 · Cited by 576
Diaphragm dysfunction assessed by ultrasonography: Influence on weaning from mechanical ventilation*
Kim, W. Y., Suh, H. J., Hong, S.-B., Koh, Y., & Lim, C.-M. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3182266408 · Cited by 550
Dres, M., Dubé, B.-P., Mayaux, J., Delemazure, J., Reuter, D., Brochard, L., Similowski, T., & Demoule, A. (2017) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201602-0367oc · Cited by 539
Self-citationDiaphragm ultrasound as a predictor of successful extubation from mechanical ventilation
DiNino, E., Gartman, E. J., Sethi, J. M., & McCool, F. D. (2014) · Thorax · doi:10.1136/thoraxjnl-2013-204111 · Cited by 487
Demoule, A., Jung, B., Prodanovic, H., Molinari, N., Chanques, G., Coirault, C., Matecki, S., Duguet, A., Similowski, T., & Jaber, S. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201209-1668oc · Cited by 459 · cited 1×
“Diaphragm dysfunction has become a leading concern in mechanically ventilated patients because of its high prevalence 1 – 4 and its association with negative clinical outcomes.”
BackgroundSelf-citationGoligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Sebastien-Bolz, S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3687-3 · Cited by 448 · cited 1×
“20 In these patients, and in patients under ACV, it is possible that the passive in fl ation of the lung and mechanical displacement of the diaphragm, as well as weak or partial respiratory efforts may be partly responsible for the observed thickening of the diaphragm, especially at higher lung…”
BackgroundDiaphragm ultrasonography to estimate the work of breathing during non-invasive ventilation
Vivier, E., Mekontso Dessap, A., Dimassi, S., Vargas, F., Lyazidi, A., Thille, A. W., & Brochard, L. (2012) · Intensive Care Medicine · doi:10.1007/s00134-012-2547-7 · Cited by 406
Impact of prolonged assisted ventilation on diaphragmatic efficiency: NAVA versus PSV
Di mussi, R., Spadaro, S., Mirabella, L., Volta, C. A., Serio, G., Staffieri, F., Dambrosio, M., Cinnella, G., Bruno, F., & Grasso, S. (2016) · Critical Care · doi:10.1186/s13054-015-1178-0 · Cited by 404
Is Weaning Failure Caused by Low-Frequency Fatigue of the Diaphragm?
Laghi, F., Cattapan, S. E., Jubran, A., Parthasarathy, S., Warshawsky, P., Choi, Y.-S. A., & Tobin, M. J. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200210-1246oc · Cited by 359
Ultrasound evaluation of the paralyzed diaphragm.
Gottesman, E., & McCool, F. D. (1997) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.155.5.9154859 · Cited by 353
Umbrello, M., Formenti, P., Longhi, D., Galimberti, A., Piva, I., Pezzi, A., Mistraletti, G., Marini, J. J., & Iapichino, G. (2015) · Critical Care · doi:10.1186/s13054-015-0894-9 · Cited by 343
Jung, B., Moury, P. H., Mahul, M., de Jong, A., Galia, F., Prades, A., Albaladejo, P., Chanques, G., Molinari, N., & Jaber, S. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4125-2 · Cited by 330 · cited 1×
“34 Relationship between EXdi and Ptr,stim EXdi was not correlated to Ptr,stim at the initiation of MV, but only moderately correlated to Ptr,stim at switch to PSV.”
BackgroundGoligher, E. C., Laghi, F., Detsky, M. E., Farias, P., Murray, A., Brace, D., Brochard, L. J., Bolz, S.-S., Rubenfeld, G. D., Kavanagh, B. P., et al. (2015) · Intensive Care Medicine · doi:10.1007/s00134-015-3724-2 · Cited by 315
Diaphragm ultrasound as a new index of discontinuation from mechanical ventilation
Ferrari, G., De Filippi, G., Elia, F., Panero, F., Volpicelli, G., & Aprà, F. (2014) · Critical Ultrasound Journal · doi:10.1186/2036-7902-6-8 · Cited by 306
VASSILAKOPOULOS, T., ZAKYNTHINOS, S., & ROUSSOS, C. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.2.9710084 · Cited by 297
Diaphragm Muscle Thinning in Patients Who Are Mechanically Ventilated
Grosu, H. B., Lee, Y. I., Lee, J., Eden, E., Eikermann, M., & Rose, K. M. (2012) · Chest · doi:10.1378/chest.11-1638 · Cited by 281
Hermans, G., Agten, A., Testelmans, D., Decramer, M., & Gayan-Ramirez, G. (2010) · Critical Care · doi:10.1186/cc9094 · Cited by 274
Diaphragm strength in chronic obstructive pulmonary disease.
Polkey, M. I., Kyroussis, D., Hamnegard, C. H., Mills, G. H., Green, M., & Moxham, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.5.8912741 · Cited by 266
Diaphragm weakness in mechanically ventilated critically ill patients
Supinski, G. S., & Ann Callahan, L. (2013) · Critical Care · doi:10.1186/cc12792 · Cited by 265
Monitoring Recovery From Diaphragm Paralysis With Ultrasound
Summerhill, E. M., El-Sameed, Y. A., Glidden, T. J., & McCool, F. D. (2008) · Chest · doi:10.1378/chest.07-2200 · Cited by 254
Watson, A. C., Hughes, P. D., Louise Harris, M., Hart, N., Ware, R. J., Wendon, J., Green, M., & Moxham, J. (2001) · Critical Care Medicine · doi:10.1097/00003246-200107000-00005 · Cited by 234 · cited 1×
“Diaphragm dysfunction has become a leading concern in mechanically ventilated patients because of its high prevalence 1 – 4 and its association with negative clinical outcomes.”
BackgroundDiaphragm Muscle Fiber Weakness and Ubiquitin–Proteasome Activation in Critically Ill Patients
Hooijman, P. E., Beishuizen, A., Witt, C. C., de Waard, M. C., Girbes, A. R. J., Spoelstra-de Man, A. M. E., Niessen, H. W. M., Manders, E., van Hees, H. W. H., van den Brom, C. E., et al. (2015) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201412-2214oc · Cited by 229
Elkins, M., & Dentice, R. (2015) · Journal of Physiotherapy · doi:10.1016/j.jphys.2015.05.016 · Cited by 204 · cited 1×
“Beyond prognostic purposes, this could prove useful for the management of indications and the follow-up of putative therapeutic approaches such as inspiratory muscle training 39 or diaphragm pacing.”
BackgroundBilateral magnetic stimulation of the phrenic nerves from an anterolateral approach.
Mills, G. H., Kyroussis, D., Hamnegard, C. H., Polkey, M. I., Green, M., & Moxham, J. (1996) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.154.4.8887614 · Cited by 183
Inhibition of Bleomycin-Induced Pulmonary Fibrosis by Okam Extract J201
Jiang, H., & Li, T. (2004) · CHEST Journal · doi:10.1378/chest.126.1.179 · Cited by 134
Neuromuscular disorders associated with failure to wean from the ventilator
Maher, J., Rutledge, F. S., Remtulla, H., Parkes, A., Bernardi, L., & Bolton, C. F. (1995) · Intensive Care Medicine · doi:10.1007/bf01704741 · Cited by 134
Ultrasonographic Evaluation of Liver/Spleen Movements and Extubation Outcome
Jiang, J., Tsai, T.-H., Jerng, J., Yu, C., Wu, H., & Yang, P. (2004) · CHEST Journal · doi:10.1016/s0012-3692(15)32912-3 · Cited by 126 · cited 1×
“It remains unclear whether diaphragm dysfunction itself has a causative effect on the prognosis of ICU patients, or if its presence should be seen as an organ dysfunction, implying a more severe underlying disease.”
BackgroundCattapan, S. E. (2003) · Thorax · doi:10.1136/thorax.58.1.58 · Cited by 64
Supinski, G. S., Westgate, P., & Callahan, L. A. (2016) · Critical Care · doi:10.1186/s13054-016-1247-z · Cited by 62 · cited 1×
“35 We measured TFdi during tidal breathing, which has the advantage of being non-volitional and possible to use even in sedated or non-cooperative patients.”
BackgroundMILLS, G. H., Ponte, J., Hamnegärd, C. H., Kyroussis, D., Polkey, M. I., Moxham, J., & Green, M. (2001) · British Journal of Anaesthesia · doi:10.1093/bja/87.6.876 · Cited by 40
Preventing Ventilator–Induced Diaphragmatic Dysfunction With Phrenic Nerve Stimulation*
Laghi, F. A., & Shaikh, H. (2014) · Critical Care Medicine · doi:10.1097/ccm.0000000000000003 · Cited by 12 · cited 1×
“12 The reference method to evaluate diaphragm function remains the measurement of the negative intrathoracic pressure generated by bilateral stimulation of the phrenic nerves.”
Method
Cited by
ERS statement on respiratory muscle testing at rest and during exercise
Laveneziana, P., Albuquerque, A., Aliverti, A., Babb, T., Barreiro, E., Dres, M., Dubé, B.-P., Fauroux, B., Gea, J., Guenette, J. A., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01214-2018 · Cited by 818
Self-citationCritical illness-associated diaphragm weakness
Dres, M., Goligher, E. C., Heunks, L. M. A., & Brochard, L. J. (2017) · Intensive Care Medicine · doi:10.1007/s00134-017-4928-4 · Cited by 402
Self-citationTuinman, P. R., Jonkman, A. H., Dres, M., Shi, Z.-H., Goligher, E. C., Goffi, A., de Korte, C., Demoule, A., & Heunks, L. (2020) · Intensive Care Medicine · doi:10.1007/s00134-019-05892-8 · Cited by 292
Self-citationHaaksma, M. E., Smit, J. M., Boussuges, A., Demoule, A., Dres, M., Ferrari, G., Formenti, P., Goligher, E. C., Heunks, L., Lim, E. H. T., et al. (2022) · Critical Care · doi:10.1186/s13054-022-03975-5 · Cited by 205
Self-citationInability of Diaphragm Ultrasound to Predict Extubation Failure
Vivier, E., Muller, M., Putegnat, J.-B., Steyer, J., Barrau, S., Boissier, F., Bourdin, G., Mekontso-Dessap, A., Levrat, A., Pommier, C., et al. (2019) · Chest · doi:10.1016/j.chest.2019.03.004 · Cited by 179
Metadata
- Authors
- Dubé, B.-P., Dres, M., Mayaux, J., Demiri, S., Similowski, T., & Demoule, A.
- Venue
- Thorax
- Publisher
- BMJ
- Published
- 2017-03-30
- Volume
- 72
- Issue
- 9
- Pages
- 811-818
- ISSN
- 0040-6376 (ISSN-L)
- 1468-3296
- OpenAlex
- W2600656146
- Cited by
- 216
- References
- 36
- FWCI
- 15.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.