Principles, Techniques, and Limitations of Near Infrared Spectroscopy
The DOI matches its Crossref record; 114 of the 114 references it cites were found in a registry or an index.
Abstract
In the last decade the study of the human brain and muscle energetics underwent a radical change, thanks to the progressive introduction of noninvasive techniques, including near-infrared (NIR) spectroscopy (NIRS). This review summarizes the most recent literature about the principles, techniques, advantages, limitations, and applications of NIRS in exercise physiology and neuroscience. The main NIRS instrumentations and measurable parameters will be reported. NIR light (700-1000 nm) penetrates superficial layers (skin, subcutaneous fat, skull, etc.) and is either absorbed by chromophores (oxy- and deoxyhemoglobin and myoglobin) or scattered within the tissue. NIRS is a noninvasive and relatively low-cost optical technique that is becoming a widely used instrument for measuring tissue O 2 saturation, changes in hemoglobin volume and, indirectly, brain/muscle blood flow and muscle O 2 consumption. Tissue O 2 saturation represents a dynamic balance between O 2 supply and O 2 consumption in the small vessels such as the capillary, arteriolar, and venular bed. The possibility of measuring the cortical activation in response to different stimuli, and the changes in the cortical cytochrome oxidase redox state upon O 2 delivery changes, will also be mentioned. Key words: tissue oximetry, oxidative metabolism, optical imaging, blood flow, oxygen consumption, exercise physiology
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These values are in a large part representative of tissue capillaries, arterioles, and venules because, in larger blood vessels, NIR light is fully absorbed by the high hemoglobin concentration. 4”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [4]
In the citing paper
“Furthermore, small differences in ambient and muscular temperature may influence day-today variability, 4 as may slight changes in posture. 38”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [4]
In the citing paper
“Optical and spectroscopic sensors that meet these criteria, include UV [4], mid-and near-infrared [8], Raman [9], and fluorescence [5] spectroscopy.”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [8]
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Strangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Non-invasive neuroimaging using near-infrared light
Strangman, G., Boas, D. A., & Sutton, J. P. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01550-0 · Cited by 903
Beyond the Visible???Imaging the Human Brain With Light
Obrig, H., & Villringer, A. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200301000-00001 · Cited by 892
Owen-Reece, H., Smith, M., Elwell, C. E., & Goldstone, J. C. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.3.418 · Cited by 688
Spontaneous Low Frequency Oscillations of Cerebral Hemodynamics and Metabolism in Human Adults
Obrig, H., Neufang, M., Wenzel, R., Kohl, M., Steinbrink, J., Einhäupl, K., & Villringer, A. (2000) · NeuroImage · doi:10.1006/nimg.2000.0657 · Cited by 614
Wittenberg, J. B., & Wittenberg, B. A. (2003) · Journal of Experimental Biology · doi:10.1242/jeb.00243 · Cited by 550
Functional near‐infrared optical imaging: Utility and limitations in human brain mapping
Hoshi, Y. (2003) · Psychophysiology · doi:10.1111/1469-8986.00053 · Cited by 532
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Research works printed but not linked: 5
- Bangsbo J., 2000, Am. J. Physiol., 279, R899
- McCully K.K., 2000, Exerc. Sport Sci. Rev., 28, 123
- Richardson R.S., 2002, Am. J. Physiol., 283, R1131
- Springett R., 2000, Am. J. Physiol., 279, H2202
- Tran T.K., 1999, Am. J. Physiol., 276, R1682
Cited by
Items 501–600 of 1,000
Shadgan, B., Stothers, L. S., & Macnab, A. J. (2008) · Spectroscopy An International Journal · doi:10.1155/2008/548152 · Cited by 15
An integrated framework of optimized learning networks for classifying oil-mixed microplastics
Chen, Y., Zhang, B., Yang, M., Xin, X., Kang, Q., Ye, X., & Chen, B. (2022) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2022.134698 · Cited by 15
Aebi, M. R., Willis, S. J., Girard, O., Borrani, F., & Millet, G. P. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01393 · Cited by 15
Changes in detrusor muscle oxygenation during detrusor overactivity contractions
Vijaya, G., Digesu, G. A., Derpapas, A., Panayi, D. C., Fernando, R., & Khullar, V. (2012) · European Journal of Obstetrics & Gynecology and Reproductive Biology · doi:10.1016/j.ejogrb.2012.03.030 · Cited by 15
Instrumentation and Calibration Protocol for a Continuous Wave Near Infrared Hemoximeter
Salvatori, G., Suh, K. I., Ansari, R. R., & Rovati, L. L. (2006) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2006.877722 · Cited by 15
Rissanen, A., Tikkanen, H. O., Koponen, A. S., Aho, J. M., & Peltonen, J. E. (2017) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2017-0222 · Cited by 14
Karlas, A., Fasoula, N., Katsouli, N., Kallmayer, M. A., Sieber, S., Schmidt, S., Liapis, E., Halle, M., Eckstein, H., & Ntziachristos, V. (2023) · Photoacoustics · doi:10.1016/j.pacs.2023.100468 · Cited by 14
Cherouveim, E. D., Miliotis, P. G., Koskolou, M. D., Δίπλα, Κ., Vrabas, I. S., & Geladas, N. D. (2023) · Biology · doi:10.3390/biology12070981 · Cited by 14
Rogers, B., Schaffarczyk, M., & Gronwald, T. (2023) · Sensors · doi:10.3390/s23041973 · Cited by 14
End‐exercise ΔHHb/ΔVO2 and post‐exercise local oxygen availability in relation to exercise intensity
Stöcker, F., Oldershausen, C. V., Paternoster, F. K., Schulz, T., & Oberhoffer, R. (2015) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12314 · Cited by 14
Marillier, M., Gruet, M., Bernard, A., Vergès, S., & Neder, J. A. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.789053 · Cited by 14
Supraspinal Fatigue and Neural-evoked Responses in Lowlanders and Sherpa at 5050 m
Ruggiero, L., & McNeil, C. J. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001748 · Cited by 14
Zhu, L., & Najafizadeh, L. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.6.066011 · Cited by 14
Intestinal perfusion monitoring using photoplethysmography
Akl, T. J., Wilson, M. A., Ericson, M. N., & Coté, G. L. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.8.087005 · Cited by 14
Neary, J. P., Dude, C. M., Singh, J., Len, T. K., & BHAMBHANI, Y. N. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.00035 · Cited by 14
Wilson, V. D., Thomas, C., Passerieux, E., Hugon, G., Pillard, F., de Andrade, A. G. P., Bommart, S., Picot, M., Pincemail, J., Mercier, J. G., et al. (2018) · JCSM Rapid Communications · doi:10.1002/j.2617-1619.2018.tb00002.x · Cited by 14
Diagnosis of testicular torsion using near infrared spectroscopy: A novel diagnostic approach
Shadgan, B., Fareghi, M., Stothers, L. S., Macnab, A. J., & Kajbafzadeh, A. M. (2014) · Canadian Urological Association Journal · doi:10.5489/cuaj.1672 · Cited by 14
Farag, F. F., Meletiadis, J., Saleem, M. D., Feitz, W., & Heesakkers, J. P. F. A. (2013) · BioMed Research International · doi:10.1155/2013/452857 · Cited by 14
Portable Protein and Fat Detector in Milk Based on Multi-Spectral Sensor and Machine Learning
Wang, Y., Zhang, K., Shi, S., Wang, Q., & Liu, S. (2023) · Applied Sciences · doi:10.3390/app132212320 · Cited by 14
Fornier, W., Jacquet‐Lagrèze, M., Collenot, T., Teixeira, P. D. M., Portran, P., Schweizer, R., Ovize, M., & Fellahi, J.-L. (2017) · Critical Care · doi:10.1186/s13054-017-1889-5 · Cited by 14
Applications of near infrared spectroscopy in cotton impurity and fiber quality detection: A review
Zhou, W., Xv, S., Liu, C., & Zhang, J. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2015.1131710 · Cited by 14
Schlappack, T., Kappacher, C., Demetz, M., Jakschitz, T. A. E., Bonn, G. K., Huck, C. W., & Rainer, M. (2023) · Analytical Methods · doi:10.1039/d3ay00380a · Cited by 14
The role of optical spectroscopy in epilepsy surgery in children
Bhatia, S., Ragheb, J. R., Johnson, M. D., Oh, S., Sandberg, D. I., & Lin, W. (2008) · Neurosurgical FOCUS · doi:10.3171/foc/2008/25/9/e24 · Cited by 14
Binzoni, T., Leung, T. S., Gandjbakhche, A., Rüfenacht, D., & Delpy, D. T. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/22/l01 · Cited by 14
Hemodilutional anemia impairs neurologic outcome after cardiopulmonary bypass in a piglet model
Miura, T., Sakamoto, T., Kobayashi, M., Shinoka, T., & Kurosawa, H. (2006) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2006.08.048 · Cited by 13
Kuai, S., Liang, Q., He, Y.-Y., & Wu, H.-N. (2020) · Brain Imaging and Behavior · doi:10.1007/s11682-020-00387-3 · Cited by 13
Influence of type 2 diabetes on muscle deoxygenation during ramp incremental cycle exercise
Gildea, N., Rocha, J., McDermott, A., O'Shea, D. B., Green, S., & Egaña, M. (2019) · Respiratory Physiology & Neurobiology · doi:10.1016/j.resp.2019.103258 · Cited by 13
Real-time automated spectral assessment of the BOLD response for neurofeedback at 3 and 7 T
Koush, Y., Elliott, M. A., Scharnowski, F., & Mathiak, K. (2013) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2013.05.002 · Cited by 13
Skeletal muscle reoxygenation after high-intensity exercise in mitochondrial myopathy
Bravo, D. M., Gimenes, A. C., Nascimento, R. B., Ferreira, E. V. M., Siqueira, A. C. B., Meda, E. D. S., Neder, J. A., & Nery, L. E. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2136-4 · Cited by 13
Classification of fNIRS based brain hemodynamic response to mental arithmetic tasks
Jounghani, A. R., Dadashi, A., Soltanian-Zadeh, H., & Setarehdan, S. K. (2017) · doi:10.1109/pria.2017.7983029 · Cited by 13
Pinheiro, V. D. S., Tavares, A. C., Volino‐Souza, M., de Oliveira, G. V., & Álvares, T. S. (2023) · Journal of Cardiovascular Development and Disease · doi:10.3390/jcdd10020063 · Cited by 13
Macnab, A. J., Stothers, L. S., & Shadgan, B. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3122886 · Cited by 13
Advances in Assistive Electronic Device Solutions for Urology
Holmes‐Martin, K., Zhu, M., Xiao, S., & Hassani, F. A. (2022) · Micromachines · doi:10.3390/mi13040551 · Cited by 13
Positive Expiratory Pressure Improves Oxygenation in Healthy Subjects Exposed to Hypoxia
Nespoulet, H., Rupp, T., Bachasson, D., Tamisier, R., Wuyam, B., Levy, P. A., & Vergès, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0085219 · Cited by 13
Lanfranconi, F., Pollastri, L., Corna, G., Bartesaghi, M., Novarina, M., Ferri, A., & Miserocchi, G. (2017) · High Altitude Medicine & Biology · doi:10.1089/ham.2017.0028 · Cited by 13
Near‐infrared spectroscopy during exercise and recovery in children with juvenile dermatomyositis
Habers, G. E. A., de Knikker, R., van Brussel, M., Hulzebos, E. H. J., Stegeman, D. F., van Royen‐Kerkhof, A., & Takken, T. (2012) · Muscle & Nerve · doi:10.1002/mus.23484 · Cited by 13
Skowno, J., Karpelowsky, J. S., Watts, N. R., & Little, D. G. (2016) · Pediatric Anesthesia · doi:10.1111/pan.13004 · Cited by 13
Basic Principle and Practical Implementation of Near-Infrared Spectroscopy (NIRS)
Bae, H. (2015) · Springer eBooks · doi:10.1007/978-3-319-14711-6_12 · Cited by 13
UBC‐Nepal expedition: peripheral fatigue recovers faster in Sherpa than lowlanders at high altitude
Ruggiero, L., Hoiland, R. L., Hansen, A. B., Ainslie, P. N., & McNeil, C. J. (2018) · The Journal of Physiology · doi:10.1113/jp276599 · Cited by 13
Géphine, S., Mucci, P., Bielmann, M., Martin, M., Bouyer, L. J., Saey, D., & Maltais, F. (2022) · Scientific Reports · doi:10.1038/s41598-022-04820-z · Cited by 13
Gomez, A., Froese, L., Bergmann, T. J. G., Sainbhi, A. S., Vakitbilir, N., Islam, A., Stein, K. Y., Marquez, I., Ibrahim, Y., & Zeiler, F. A. (2024) · Sensors · doi:10.3390/s24020499 · Cited by 13
Does chest compression during cardiopulmonary resuscitation provide sufficient cerebral oxygenation?
Yazar, M. A., & Açıkgöz, M. B. (2019) · TURKISH JOURNAL OF MEDICAL SCIENCES · doi:10.3906/sag-1809-165 · Cited by 13
Influence of Whole-Body Vibration Static Exercise on Quadriceps Oxygenation
Calvisi, V., Angelozzi, M., Franco, A., Mottola, L., Crisostomi, S., Corsica, C., Ferrari, M., & Quaresima, V. (2006) · Springer eBooks · doi:10.1007/0-387-29540-2_22 · Cited by 13
Self-citationNeuroimaging with functional near infrared spectroscopy: From formation to interpretation
Herrera-Vega, J., Treviño-Palacios, C. G., & Orihuela‐Espina, F. (2017) · Infrared Physics & Technology · doi:10.1016/j.infrared.2017.06.011 · Cited by 12
St-Amant, G., Salzman, T., Michaud, L., Polskaia, N., Fraser, S., & Lajoie, Y. (2022) · Human Movement Science · doi:10.1016/j.humov.2022.102931 · Cited by 12
Knols, R. H., Swanenburg, J., Bon, D. D., Gennaro, F., Wolf, M., Krüger, B. D., Béttex, D., & de Bruin, E. D. (2017) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2017.00085 · Cited by 12
Portable muscle oxygenation monitor based on near infrared spectroscopy
Zhang, Z., Wang, B., Qing, N., Luo, Q., & Gong, H. (2009) · Frontiers of Optoelectronics in China · doi:10.1007/s12200-009-0050-8 · Cited by 12
Smet, S. D., D’Hulst, G., Poffé, C., Thienen, R. V., Berardi, E., & Hespel, P. (2018) · European Journal of Applied Physiology · doi:10.1007/s00421-018-3820-4 · Cited by 12
Near-infrared spectroscopy as a quantitative spasticity assessment tool: A systematic review
McDougall, J., Chow, E., Harris, R. L., & Mills, P. B. (2020) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2020.116729 · Cited by 12
Beaume, J. B., Domenico, H. D., Bowen, M., Hintzy, F., Millet, G. Y., Pageaux, B., Debevec, T., & Rupp, T. (2025) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/sms.70021 · Cited by 12
Rezende, C., de Oliveira, G. V., Volino‐Souza, M., Castro, P., Murias, J. M., & Álvares, T. S. (2021) · International Journal of Food Sciences and Nutrition · doi:10.1080/09637486.2021.1972411 · Cited by 12
Effects of Active and Passive Recovery on Muscle Oxygenation and Swimming Performance
Pratama, A. B., & Yimlamai, T. (2020) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2019-0537 · Cited by 12
Wearable wireless real-time cerebral oximeter for measuring regional cerebral oxygen saturation
Si, J., Zhang, X., Li, M., Yu, J. H., Zhang, Z., He, Q., Chen, S., Zhu, L., & Jiang, T. (2020) · Science China Information Sciences · doi:10.1007/s11432-020-2995-5 · Cited by 12
van der Harst, J. J., Elting, J. W. J., Bokkers, R. P. H., Veeger, N. J. G. M., van Donkelaar, C. E., van den Bergh, W. M., Metzemaekers, J. D. M., Groen, R. J. M., Mazuri, A., Luijckx, G. J., et al. (2023) · World Neurosurgery · doi:10.1016/j.wneu.2023.07.033 · Cited by 12
Ribeiro, F. A., Oueslati, F., Saey, D., Lépine, P.-A., CHAMBAH, S., Coats, V., & Maltais, F. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001856 · Cited by 12
Ito, K., Ookawara, S., Okochi, T., Ueda, Y., Kofuji, M., Hayasaka, H., Uchida, T., Miyazawa, H., Yanai, K., Ishii, H., et al. (2017) · BioMed Research International · doi:10.1155/2017/2852514 · Cited by 12
A near-infrared calibration method suitable for quantification of broadband data in humans
Zhang, Q., Srinivasan, S., Wu, Y., Natah, S., & Dunn, J. F. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.01.037 · Cited by 12
Imaging of neuro-cognitive performance in extreme Environments—A (p)review
Schneider, S., Bubeev, J. A., Choukèr, A., Morukov, B. V., Johannes, B. W., & Strüder, H. K. (2012) · Planetary and Space Science · doi:10.1016/j.pss.2012.06.021 · Cited by 12
Gustafsson, P., Crenshaw, A. G., Edmundsson, D., Toolanen, G., & Crnalic, S. (2017) · PLoS ONE · doi:10.1371/journal.pone.0186790 · Cited by 12
Modelling of Mitochondrial Oxygen Consumption and NIRS Detection of Cytochrome Oxidase Redox State
Banaji, M., Mallet, A., Elwell, C. E., Nicholls, P., Tachtsidis, I., Smith, M., & Cooper, C. E. (2009) · Advances in experimental medicine and biology · doi:10.1007/978-1-4419-1241-1_41 · Cited by 12
Effects of multicomponent exercise training on muscle oxygenation in young and older adults
Lin, T.-Y., Chen, J. J., Lin, L. L.-C., Yang, W.-T. O., Chen, M., & Tsai, Y.-C. (2022) · Journal of Exercise Science & Fitness · doi:10.1016/j.jesf.2022.12.002 · Cited by 11
Ding, F., Rivero-Delgado, M. Á., Zha, R., & Martín, J. F. G. (2025) · Food Control · doi:10.1016/j.foodcont.2025.111878 · Cited by 11
Cardenas, A. K., Albert, W. J., Léger, M. C., Dion, C., & Cardoso, M. R. (2024) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2024.103587 · Cited by 11
Wu, Y., Song, T., & Xu, G. (2015) · Frontiers of Optoelectronics · doi:10.1007/s12200-015-0532-9 · Cited by 11
Vardarli, E., Satiroglu, R., Allen, J. R., Bjellquist-Ledger, R. C., Burton, H. M., & Coyle, E. F. (2021) · European Journal of Applied Physiology · doi:10.1007/s00421-021-04677-6 · Cited by 11
Ookawara, S., Ito, K., Sasabuchi, Y., Ueda, Y., Hayasaka, H., Kofuji, M., Uchida, T., Horigome, K., Aikawa, T., Imada, S., et al. (2021) · The Nephron journals/Nephron journals · doi:10.1159/000513327 · Cited by 11
Qi, P., Sun, L., Ma, J., Yao, J., Lin, L., Zhang, L., Wang, Y., & Liu, W. (2019) · Journal of Biophotonics · doi:10.1002/jbio.201800472 · Cited by 11
Good, J., Viana, E., Burgomaster, K. A., & Dogra, S. (2018) · Journal of Sports Sciences · doi:10.1080/02640414.2018.1488520 · Cited by 11
Léger, M. C., Cardoso, M. R., Dion, C., & Albert, W. J. (2022) · Applied Ergonomics · doi:10.1016/j.apergo.2022.103741 · Cited by 11
Chai, C., Liu, S., Fan, L., Liu, L., Li, J., Zuo, C., Qian, T., Haacke, E. M., Shen, W., & Xia, S. (2017) · Metabolic Brain Disease · doi:10.1007/s11011-017-0164-4 · Cited by 11
Skeletal Muscle Microvascular Adaptations Following Regular Cold Water Immersion
Ihsan, M., Watson, G., Choo, H. C., Govus, A. D., Cocking, S., Stanley, J., & Abbiss, C. R. (2019) · International Journal of Sports Medicine · doi:10.1055/a-1044-2397 · Cited by 11
Near-infrared spectroscopy in the medical management of infants
Bailey, S. M., Prakash, S. S., Verma, S., Desai, P. V., Kazmi, S. H., & Mally, P. (2022) · Current problems in pediatric and adolescent health care · doi:10.1016/j.cppeds.2022.101291 · Cited by 11
Efectos del tipo de recuperación sobre la oxigenación muscular durante el ejercicio de sentadilla
Bastida‐Castillo, A., Gómez‐Carmona, C. D., & Pino‐Ortega, J. (2016) · KRONOS · doi:10.64197/kronos.15.01-02.807 · Cited by 11
Hybrid sEMG, NIRS and MMG Sensor System
Ding, X., Wang, M., Guo, W., Sheng, X., & Zhu, X. (2018) · International Conference on Mechatronics and Machine Vision in Practice (M2VIP) · doi:10.1109/m2vip.2018.8600866 · Cited by 11
Hyperoxia Improves Repeated-Sprint Ability and the Associated Training Load in Athletes
Cyr-Kirk, S., & Billaut, F. (2022) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2022.817280 · Cited by 11
Marillier, M., Bernard, A., Vergès, S., Moran‐Mendoza, O., & Neder, J. A. (2023) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12809 · Cited by 11
Near Infrared Spectroscopy for Poor Grade Aneurysmal Subarachnoid Hemorrhage—A Concise Review
Francoeur, C. L., Lauzier, F., Brassard, P., & Turgeon, A. F. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.874393 · Cited by 11
High quantum efficiency broadband near-infrared LaTiSbO6:Cr3+ phosphors
Zhou, C., Chen, Z., Wu, H., Zhou, L., Zhang, X., & Yong, X. (2024) · Journal of Luminescence · doi:10.1016/j.jlumin.2024.120723 · Cited by 11
Chatzinikolaou, P. N., Margaritelis, N. V., Paschalis, V., Theodorou, A. A., Moushi, E. E., Vrabas, I. S., Kyparos, A., Fatouros, I. G., D’Alessandro, A., & Nikolaidis, M. G. (2025) · Sports Medicine · doi:10.1007/s40279-025-02279-2 · Cited by 10
Cortese, L., Esteberena, P. F., Zanoletti, M., Presti, G. L., Velazquez, G. B. A., Ruiz, S., Buttafava, M., Renna, M., Sieno, L. D., Tosi, A., et al. (2023) · Physiological Measurement · doi:10.1088/1361-6579/ad133a · Cited by 10
Tempest, G. D., & Parfitt, G. (2017) · Psychophysiology · doi:10.1111/psyp.12858 · Cited by 10
Muscle Oxygenation During Hypoxic Exercise in Children and Adults
Ušaj, A., Mekjavić, I. B., Kapus, J., McDonnell, A. C., Mekjavič, P. J., & Debevec, T. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01385 · Cited by 10
Pain Biomarkers in Cancer: An Overview
Calapai, F., Mondello, E., Mannucci, C., Sorbara, E. E., Gangemi, S., Quattrone, D., Calapai, G., & Cardia, L. (2020) · Current Pharmaceutical Design · doi:10.2174/1381612826666201102103520 · Cited by 10
Oelschlägel, M., Polanski, W. H., Morgenstern, U., Steiner, G. R., Kirsch, M., Koch, E., Schackert, G., & Sobottka, S. B. (2021) · Human Brain Mapping · doi:10.1002/hbm.25674 · Cited by 10
Gervain, J. (2015) · Elsevier eBooks · doi:10.1016/b978-0-08-097086-8.55061-2 · Cited by 10
Palzkill, V. R., Tan, J., Moparthy, D., Tice, A. L., Ferreira, L. F., & RYAN, T. E. (2024) · JACC Basic to Translational Science · doi:10.1016/j.jacbts.2024.08.011 · Cited by 10
Eyes as Gateways for Environmental Light to the Substantia Nigra: Relevance in Parkinson’s Disease
Romeo, S., Camillo, D. D., Splendiani, A., Capannolo, M., Rocchi, C., Aloisi, G., Fasciani, I., Corsini, G. U., Scarnati, E., Lozzi, L., et al. (2014) · The Scientific World JOURNAL · doi:10.1155/2014/317879 · Cited by 10
Ebner, J., Humer, D., Klausser, R., Rubus, V., Pell, R., Spadiut, O., & Kopp, J. (2021) · Bioengineering · doi:10.3390/bioengineering8060078 · Cited by 10
Hussain, A., Faye, I., Muthuvalu, M. S., Tang, T. B., & Zafar, M. (2023) · Axioms · doi:10.3390/axioms12040326 · Cited by 10
Kuroiwa, M., Fuse, S., Amagasa, S., Kime, R., Endo, T., Kurosawa, Y., & Hamaoka, T. (2019) · Applied Sciences · doi:10.3390/app9122442 · Cited by 10
Advancement in Raman spectroscopy (RS) for characterizing cementitious materials
Zhang, Z., Huang, Z., Shi, C. W., Wu, Z., Zhang, W., Duan, P., & Jiang, Z. (2024) · Journal of the American Ceramic Society · doi:10.1111/jace.20162 · Cited by 10
Low-Dose Vasopressin and Renal Perfusion in Pediatric Cardiac Surgery
Kumar, A., Ghotra, G. S., Raj, S., Tiwari, N., & Ramamurthy, H. R. (2023) · Annals of Cardiac Anaesthesia · doi:10.4103/aca.aca_182_22 · Cited by 10
Active and Inactive Leg Hemodynamics during Sequential Single-Leg Interval Cycling
Gordon, N. A., Abbiss, C. R., Ihsan, M., Maiorana, A., & Peiffer, J. J. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001553 · Cited by 10
Ferrari, M., Cettolo, V., & Quaresima, V. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01207.2005 · Cited by 10
Self-citationde Oliveira, G. V., Volino‐Souza, M., Leitão, R., Pinheiro, V. D. S., Conte‐Júnior, C. A., & Álvares, T. S. (2021) · Jornal Vascular Brasileiro · doi:10.1590/1677-5449.200143 · Cited by 10
Knauth, M., Heldmann, M., Münte, T. F., & Royl, G. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.062 · Cited by 10
Suzuki, Y., Yamamoto, M., Sugiyama, K., Akai, T., Suzuki, K., Kawamura, T., Sakata, M., Morita, Y., Kikuchi, H., Hiramatsu, Y., et al. (2020) · Surgery Today · doi:10.1007/s00595-020-02171-8 · Cited by 10
Huang, Y., Xu, F., Hu, H., Dai, X., & Zhang, H. (2018) · International Journal of Food Properties · doi:10.1080/10942912.2018.1502199 · Cited by 10
Rokkedal-Lausch, T., Franch, J., Poulsen, M. K., Thomsen, L. P., Weitzberg, E., Kamavuako, E. N., Karbing, D. S., & Larsen, R. G. (2021) · Nitric Oxide · doi:10.1016/j.niox.2021.03.006 · Cited by 9
Cardiovascular and cerebral hemodynamic responses to ego depletion in a pressurized sporting task.
O'Brien, J., Parker, J. K., Moore, L. J., & Fryer, S. M. (2020) · Sport Exercise and Performance Psychology · doi:10.1037/spy0000199 · Cited by 9
Metadata
- Authors
- Ferrari, M., Mottola, L., & Quaresima, V.
- Affiliations
- University of L'Aquila (IT)
- Casa Sollievo della Sofferenza (IT)
- Kyoto University (JP)
- Venue
- Canadian Journal of Applied Physiology
- Publisher
- Canadian Science Publishing
- Published
- 2004-08-01
- Volume
- 29
- Issue
- 4
- Pages
- 463-487
- ISSN
- 1066-7814 (ISSN-L)
- OpenAlex
- W2130603606
- Semantic Scholar
- bd62a0617aa90919c1ddae952300dc20d128d7da
- Cited by
- 997
- References
- 114
- Citations by year
- 2026: 35 · 2025: 51 · 2024: 44 · 2023: 58 · 2022: 53 · 2021: 46 · 2020: 53 · 2019: 55 · 2018: 54 · 2017: 63 · 2016: 48 · 2015: 52 · 2014: 36 · 2013: 56 · 2012: 68
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.nrcresearchpress.com/page/about/CorporateTextAndDataMining (tdm)
- Locations
- Canadian Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
- Funders
- U.S. Food and Drug Administration
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- near-infrared spectroscopy, tissue oxygen saturation, hemoglobin, myoglobin, muscle oxygen consumption, cerebral blood flow, brain energy metabolism, cortical activation, cytochrome c oxidase, light scattering, exercise physiology, non-invasive optical measurement
- MeSH terms
- Blood Volume, Cerebral Cortex, Cerebrovascular Circulation, Humans, Oximetry, Oxygen Consumption, Regional Blood Flow, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.