Principles, Techniques, and Limitations of Near Infrared Spectroscopy
The DOI matches its Crossref record; 114 of the 114 references it cites were found in a registry or an index.
Abstract
In the last decade the study of the human brain and muscle energetics underwent a radical change, thanks to the progressive introduction of noninvasive techniques, including near-infrared (NIR) spectroscopy (NIRS). This review summarizes the most recent literature about the principles, techniques, advantages, limitations, and applications of NIRS in exercise physiology and neuroscience. The main NIRS instrumentations and measurable parameters will be reported. NIR light (700-1000 nm) penetrates superficial layers (skin, subcutaneous fat, skull, etc.) and is either absorbed by chromophores (oxy- and deoxyhemoglobin and myoglobin) or scattered within the tissue. NIRS is a noninvasive and relatively low-cost optical technique that is becoming a widely used instrument for measuring tissue O 2 saturation, changes in hemoglobin volume and, indirectly, brain/muscle blood flow and muscle O 2 consumption. Tissue O 2 saturation represents a dynamic balance between O 2 supply and O 2 consumption in the small vessels such as the capillary, arteriolar, and venular bed. The possibility of measuring the cortical activation in response to different stimuli, and the changes in the cortical cytochrome oxidase redox state upon O 2 delivery changes, will also be mentioned. Key words: tissue oximetry, oxidative metabolism, optical imaging, blood flow, oxygen consumption, exercise physiology
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These values are in a large part representative of tissue capillaries, arterioles, and venules because, in larger blood vessels, NIR light is fully absorbed by the high hemoglobin concentration. 4”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [4]
In the citing paper
“Furthermore, small differences in ambient and muscular temperature may influence day-today variability, 4 as may slight changes in posture. 38”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [4]
In the citing paper
“Optical and spectroscopic sensors that meet these criteria, include UV [4], mid-and near-infrared [8], Raman [9], and fluorescence [5] spectroscopy.”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [8]
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Strangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Non-invasive neuroimaging using near-infrared light
Strangman, G., Boas, D. A., & Sutton, J. P. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01550-0 · Cited by 903
Beyond the Visible???Imaging the Human Brain With Light
Obrig, H., & Villringer, A. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200301000-00001 · Cited by 892
Owen-Reece, H., Smith, M., Elwell, C. E., & Goldstone, J. C. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.3.418 · Cited by 688
Spontaneous Low Frequency Oscillations of Cerebral Hemodynamics and Metabolism in Human Adults
Obrig, H., Neufang, M., Wenzel, R., Kohl, M., Steinbrink, J., Einhäupl, K., & Villringer, A. (2000) · NeuroImage · doi:10.1006/nimg.2000.0657 · Cited by 614
Wittenberg, J. B., & Wittenberg, B. A. (2003) · Journal of Experimental Biology · doi:10.1242/jeb.00243 · Cited by 550
Functional near‐infrared optical imaging: Utility and limitations in human brain mapping
Hoshi, Y. (2003) · Psychophysiology · doi:10.1111/1469-8986.00053 · Cited by 532
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Research works printed but not linked: 5
- Bangsbo J., 2000, Am. J. Physiol., 279, R899
- McCully K.K., 2000, Exerc. Sport Sci. Rev., 28, 123
- Richardson R.S., 2002, Am. J. Physiol., 283, R1131
- Springett R., 2000, Am. J. Physiol., 279, H2202
- Tran T.K., 1999, Am. J. Physiol., 276, R1682
Cited by
Items 701–800 of 1,000
Li, Y., Mo, P., Peng, F., Guo, J., Sheng, Z., Lyu, S., & Jan, Y. (2023) · Journal of Back and Musculoskeletal Rehabilitation · doi:10.3233/bmr-230158 · Cited by 5
Sedlacik, J., Reitz, M., Bolar, D. S., Adalsteinsson, E., Schmidt, N. O., & Fiehler, J. (2014) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2014.01.004 · Cited by 5
Caccamo, M. T., & Magazù, S. (2022) · Molecules · doi:10.3390/molecules27196310 · Cited by 5
Wolfsberger, C. H., Bruckner, M., Schwaberger, B., Mileder, L. P., Pritišanac, E., Höller, N., Avian, A., Urlesberger, B., & Pichler, G. (2021) · Frontiers in Pediatrics · doi:10.3389/fped.2021.747509 · Cited by 5
Reference values for triceps surae tissue oxygen saturation by near-infrared spectroscopy
de Faria, V. C., de Oliveira, L. F. L., Ferreira, A. P., Cunha, T. E. D. O., Fernandes, J. S. A., Pussieldi, G. D. A., & Pereira, D. A. G. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac9452 · Cited by 5
Šinko, L., Regier, P. S., Curtin, A., Ayaz, H., Childress, A. R., & Teitelman, A. M. (2022) · Women s Health · doi:10.1177/17455057221081326 · Cited by 5
Critical power and critical oxygenation: examining transferability between normoxia and hypoxia
Kowalski, T., Rębiś, K., Wilk, A., Szwed, P., Klusiewicz, A., Debevec, T., & Faiss, R. (2025) · European Journal of Applied Physiology · doi:10.1007/s00421-025-05825-y · Cited by 5
Ušaj, A., Sotiridis, A., & Debevec, T. (2023) · Biology · doi:10.3390/biology12030457 · Cited by 5
Salvas, J. P., Leyba, K. A., Schepers, L. E., Paiyabhroma, N., Goergen, C. J., & Sicard, P. (2023) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2023.3265800 · Cited by 5
Auxiliary Muscles and Slow Component during Rowing
Demarie, S., Quaresima, V., Ferrari, M., Billat, V. L., Sbriccoli, P., & Faina, M. (2008) · International Journal of Sports Medicine · doi:10.1055/s-2008-1038411 · Cited by 5
Self-citationHemodynamic Methods: fMRI and fNIRS
Willems, R. M., & Cristià, A. (2017) · Wiley eBooks · doi:10.1002/9781394259762.ch14 · Cited by 5
Xiao, F., Liu, M., Wang, Y., Zhou, L., Luo, J., Chen, C., & Chen, W. (2024) · Bioengineering · doi:10.3390/bioengineering11040389 · Cited by 5
Near-infrared parameters extraction: A potential method to detect skin cancer
Truong, B. C. Q., Tuan, H. D., & Nguyen, H. T. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609430 · Cited by 5
Gersten, A. (2015) · InTech eBooks · doi:10.5772/59113 · Cited by 5
NIRS-based experimental evaluation of driver back fatigue during long-term driving
Jin, S. H., An, J., Lee, S., Lee, I., & Kim, H. (2018) · Biotechnology & Biotechnological Equipment · doi:10.1080/13102818.2018.1446763 · Cited by 5
Haemoglobin oxygen saturation as a biomarker: the problem and a solution
Oas, A. A. B., Aria, M., & Ranceschini, A. N. F. (2016) · Cited by 5
Dech, S., Bittmann, F. N., & Schaefer, L. V. (2022) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-022-00447-9 · Cited by 5
Quaresima, V., & Ferrari, M. (2006) · The Journal of Physiological Sciences · doi:10.2170/physiolsci.l656 · Cited by 5
Self-citationAdvanced aptamer-based sensors for monitoring theophylline
Hartati, Y. W., Zein, M. I. H. L., Ibrahim, A. U., Kharismasari, C. Y., Syafira, R. S., Irkham, I., Gunlazuardi, J., & Jiwanti, P. K. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120200 · Cited by 5
Exploring mixed reality robot communication under different types of mental workload
Tran, N. (2020) · Digital Collections of Colorado (Colorado State University) · Cited by 5
Monitoring in Critically Ill Children
Marr, J., & Abramo, T. J. (2008) · Elsevier eBooks · doi:10.1016/b978-141600087-7.50008-8 · Cited by 5
A Comprehensive Review: Hyperspectral and Modern Spectroscopy Identification of Yogurt Adulteration
Aqeel, M., Muhammad, S. A., Anas, M., Sargana, H. M., Naeem, M., Razi, M. A., & Siddique, U. (2025) · Pakistan Journal of Scientific Research · doi:10.57041/34kv2j39 · Cited by 5
Kappacher, C., Schwarz, B., Rainer, M., & Huck, C. W. (2024) · Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy · doi:10.1016/j.saa.2024.123955 · Cited by 5
IBADOV, R. A., Сёмаш, К. О., Акбаров, М. М., Dzhanbekov, T., Omonov, O., Usmonov, A., & IBRAGIMOV, S. K. (2025) · Clinical Transplantation and Research · doi:10.4285/ctr.24.0067 · Cited by 5
Clancy, M. T., Belli, A., Davies, D. J., Lucas, S. J. E., Su, Z., & Dehghani, H. (2016) · Journal of Biophotonics · doi:10.1002/jbio.201500302 · Cited by 5
Near-Infrared Spectroscopy for the In Vivo Monitoring of Biodegradable Implants in Rats
Hassan, H. W., Mota‐Silva, E., Grasso, V., Riehakainen, L., Jose, J., Menichetti, L., & Mirtaheri, P. (2023) · Sensors · doi:10.3390/s23042297 · Cited by 5
Chambion-Diaz, M., Chertin, J., Pialoux, V., & Billaut, F. (2025) · Journal of Sports Sciences · doi:10.1080/02640414.2025.2474333 · Cited by 4
Analytical Techniques in Forensic Science: Spectroscopy and Chromatography
Neole, N. G. (2024) · IGI Global eBooks · doi:10.4018/978-1-6684-9800-2.ch008 · Cited by 4
Laurent, S., Paire‐Ficout, L., Boucheix, J., Argon, S., & Hidalgo-Muñoz, A. R. (2021) · Brain Sciences · doi:10.3390/brainsci11020196 · Cited by 4
Cerebral oxygenation changes in response to post-hemodialysis standing
Imai, S., Ookawara, S., Ito, K., Hattori, T., Fueki, M., Iguchi, M., Kiryu, S., Sanayama, H., Kakei, M., Tabei, K., et al. (2022) · Journal of Artificial Organs · doi:10.1007/s10047-022-01343-2 · Cited by 4
Heterogeneous sensitivity of cerebral and muscle tissues to acute normobaric hyperoxia at rest
Keramidas, M. E., Kounalakis, S. N., Geladas, N. D., Eiken, O., & Mekjavić, I. B. (2012) · Microvascular Research · doi:10.1016/j.mvr.2012.05.007 · Cited by 4
Measurement of Hemoglobin Oxygenation Parameters in Arterial Occlusion and Physical Exertion
Buyanov, D., Владимирович, Ш. П., Zabodaev, S. V., Monakhova, P. A., Stavtsev, D. D., Konovalov, A. N., & Gerasimenko, A. Y. (2023) · Biomedical Engineering · doi:10.1007/s10527-023-10299-3 · Cited by 4
Jawa, N. A., Holden, R. M., Silver, S. A., Scott, S. H., Day, A. G., Norman, P. A., Kwan, B. Y. M., Maslove, D. M., Muscedere, J., & Boyd, J. G. (2021) · BMJ Open · doi:10.1136/bmjopen-2021-049250 · Cited by 4
Kumar, A., Chellappan, K., Nasution, A. M. T., Pawar, D., Patel, M. K., & Kanawade, R. V. (2022) · Sensors & Diagnostics · doi:10.1039/d2sd00126h · Cited by 4
Application of near-infrared spectroscopy (NIRS) in ergonomics and exercise
BHAMBHANI, Y. N. (2010) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2009.12.002 · Cited by 4
Aviram, R., Kima, I., Parmet, Y., Bassan, H., Willigenburg, T. R., Riemer, R., & Bar‐Haim, S. (2023) · Developmental Medicine & Child Neurology · doi:10.1111/dmcn.15508 · Cited by 4
Probing Brain Oxygenation Waveforms with Near Infrared Spectroscopy (NIRS)
Gersten, A., Perle, J., Heimer, D., Raz, A., & Frie, R. (2012) · InTech eBooks · doi:10.5772/39025 · Cited by 4
Lahti, D. S., Pockett, C. R., Boyes, N. G., Bradley, T. J., Butcher, S. J., Wright, K. D., ERLANDSON, M. C., & Tomczak, C. R. (2022) · CJC Pediatric and Congenital Heart Disease · doi:10.1016/j.cjcpc.2022.08.002 · Cited by 4
Multimodality neuromonitoring for perioperative brain protection
Edmonds, H. L. (2005) · Seminars in Anesthesia Perioperative Medicine and Pain · doi:10.1053/j.sane.2005.10.004 · Cited by 4
Schecklmann, M., & rzburg, U. T. W. (2009) · Online Publication Service of Würzburg University (Würzburg University) · Cited by 4
Cerebrovascular effects of vasoactive drugs: In vitro, in vivo and clinical investigations
Mamo, Y. A. (2015) · Minerva Access (University of Melbourne) · doi:10.13140/rg.2.1.4167.1521 · Cited by 4
Single-capillary endothelial dysfunction resolved by optoacoustic mesoscopy
He, H., Karlas, A., Fasoula, N., Fischer, C., Darsow, U. G., Kallmayer, M. A., Aguirre, J., Eckstein, H., & Ntziachristos, V. (2026) · Light Science & Applications · doi:10.1038/s41377-025-02103-6 · Cited by 4
Lan, J. L. (2013) · PolyPublie (École Polytechnique de Montréal) · Cited by 4
Warnecke, J., Wendt, T. G., Winkler, S., Schak, M., Schiffer, T., & Kohl‐Bareis, M. (2013) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/cjpp-2013-0158 · Cited by 4
Wolfsberger, C. H., Bruckner, M., Schlatzer, C., Schwaberger, B., Baik‐Schneditz, N., Urlesberger, B., & Pichler, G. (2024) · Paediatric Respiratory Reviews · doi:10.1016/j.prrv.2024.11.001 · Cited by 4
Kaneko, S., Ookawara, S., Ito, K., Minato, S., Mutsuyoshi, Y., Ueda, Y., Hirai, K., & Morishita, Y. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12154904 · Cited by 4
Tu, K. J., Lam, J. H., & Kim, S. (2023) · Translational Andrology and Urology · doi:10.21037/tau-23-297 · Cited by 4
Tu, K. J., Lam, J. H., Kang, B.-I., Kim, A., & Kim, S. (2023) · International Neurourology Journal · doi:10.5213/inj.2346248.124 · Cited by 4
Lioe, D. X., Fukushi, Y., Hakamata, M., Niwayama, M., Mars, K., Yasutomi, K., Kagawa, K., Yamamoto, S., & Kawahito, S. (2023) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2023.3236591 · Cited by 4
Peripheral perfusion noninvasive monitoring technologies - a literature and patent review
Plaza, I. O., Dankelman, J., & Bakker, J. (2026) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-026-01412-4 · Cited by 3
The Etiology and Evolution of Fetal Brain Injury
Macnab, A. J. (2012) · InTech eBooks · doi:10.5772/38441 · Cited by 3
Cardiac workload and skeletal muscle oxygenation during incremental exercise in healthy subjects
Jeskanen, T., Valtonen, R. I. P., Ylinen, V. P., Nissinen, J., & Tulppo, M. P. (2025) · Physiological Reports · doi:10.14814/phy2.70456 · Cited by 3
Aldayel, A. A. (2010) · Research Online (Edith Cowan University) · Cited by 3
Machine learning–assisted multispectral and hyperspectral imaging
Yoon, S.-C., & Ekramirad, N. (2024) · Elsevier eBooks · doi:10.1016/b978-0-443-22001-2.00009-3 · Cited by 3
Quantitative Susceptibility Mapping of Venous Vessels in Neonates with Perinatal Asphyxia
Weber, A. M., Zhang, Y., Kames, C., & Rauscher, A. (2021) · American Journal of Neuroradiology · doi:10.3174/ajnr.a7086 · Cited by 3
Kang, M., Youn, C., Lee, J., & Lee, J. (2024) · Journal of Environmental Science International · doi:10.5322/jesi.2024.33.1.1 · Cited by 3
Stöcker, F., Oldershausen, C. V., Paternoster, F. K., Schulz, T., & Oberhoffer, R. (2017) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12434 · Cited by 3
Scherer, L. C. (2007) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) · Cited by 3
Schultz, E. (2020) · ISU Red - Research and eData (Illinois State University) · doi:10.30707/etd2020.schultz.e · Cited by 3
de Oliveira, G. V., Volino‐Souza, M., Barros-Santos, E., Conte‐Júnior, C. A., & Álvares, T. S. (2022) · Sport Sciences for Health · doi:10.1007/s11332-021-00892-y · Cited by 3
Occlusive Cerebrovascular Disease: Anesthetic Considerations
Chui, J., Herrick, I. A., Higashida, R. T., & Gelb, A. W. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-93273-8.00016-x · Cited by 3
Using the Placebo Effect to Isolate Control Mechanisms of Athletic Performance: A Research Protocol
Broelz, E. K., Enck, P., Niess, A. M., Schneeweiß, P., & Weimer, K. (2015) · Sports and Exercise Medicine - Open Journal · doi:10.17140/semoj-1-109 · Cited by 3
Cerebrovascular Reactivity Measurement with Functional Near Infrared Spectroscopy
Amyot, F., Davis, C., Sangobowale, M., Moore, C. B., Silverman, E., Gandjbakhche, A., Diaz-Arrastia, R. R., & Kenney, K. (2022) · Journal of Visualized Experiments · doi:10.3791/61284 · Cited by 3
Measurements of cerebral arterial oxygen saturation using a fiber-optic pulse oximeter
Phillips, J. P., Langford, R. M., Chang, S. H., Maney, K., Kyriacou, P. A., & Jones, D. P. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5334604 · Cited by 3
Developments in near infrared spectroscopy
Mills, I. M., Downey, G., Robert, P., & Bertrand, D. (1992) · Analytical Proceedings · doi:10.1039/ap9922900007 · Cited by 3
Postoperative Central Nervous System Monitoring
Dabbagh, A. (2013) · Springer eBooks · doi:10.1007/978-3-642-40418-4_5 · Cited by 3
Predicting muscle anaerobic threshold by using a wearable optical sensor during exercise
Mah, A. J., Nourizadeh, M., Wyss, J. K. M., Askari, S., & Shadgan, B. (2023) · Biophotonics in Exercise Science, Sports Medicine, Health Monitoring Technologies, and Wearables · doi:10.1117/12.2668675 · Cited by 3
Klaessens, J. H. G. M., Noordmans, H. J., de Roode, R., & Verdaasdonk, R. M. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-03879-2_203 · Cited by 3
Al-Rawi, P. G., & Kirkpatrick, P. J. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4377-0167-8.00033-9 · Cited by 3
Acute Cardiopulmonary and Muscle Oxygenation Responses to Normocapnic Hyperpnea Exercise in COPD
OUESLATI, F., Saey, D., Vézina, F.-A., NADREAU, É., MARTIN, M., & MALTAIS, F. (2021) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002760 · Cited by 3
Noninvasive NMR and NIRS Measurement of Vascular and Intracellular Oxygenation In Vivo
Chung, Y., & Jue, T. (2013) · Springer eBooks · doi:10.1007/978-1-4614-6252-1_8 · Cited by 3
Kol, B. K., Güçlü, M. B., Baytok, E., & Demirci, N. Y. (2024) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2024.2327534 · Cited by 3
Harris, H. (2020) · ISU Red - Research and eData (Illinois State University) · doi:10.30707/etd2020.harris.h · Cited by 3
Personalized treatment approaches in neurocritical care
Kim, J. H., Kim, C., Jeon, H., Jung, H.-C., & Lee, S. (2025) · Acute and Critical Care · doi:10.4266/acc.003050 · Cited by 3
Quantifier les aléas volcaniques liés au dégazage de CO2 : apport de la modélisation numérique
Rafflin, V. (2023) · theses.fr (ABES) · doi:10.70675/4e1df3e3z2a71z465cz8cecza011c7e73e75 · Cited by 3
Patients with complex congenital heart disease have slower calf muscle oxygenation during exercise
Sandberg, C., Crenshaw, A. G., Elçadi, G. H., Christersson, C., Hlebowicz, J., Thilén, U. J., & Johansson, B. H. (2021) · International Journal of Cardiology Congenital Heart Disease · doi:10.1016/j.ijcchd.2021.100157 · Cited by 3
Ramachandran, R., Narayanam, M., Wethman, R. G., Jayaraman, K. S., Dikundwar, A. G., & Bhutani, H. (2022) · Spectroscopy · doi:10.56530/spectroscopy.cd1689c2 · Cited by 3
YORULMAZ, İ. S., Özlü, O., Demiraran, Y., Sezen, G., & Boran, E. (2015) · International Journal of Clinical Medicine · doi:10.4236/ijcm.2015.612125 · Cited by 3
Gómez-Carmona, C. D., Bastida‐Castillo, A., & Pino‐Ortega, J. (2019) · Revista Andaluza de Medicina del Deporte · doi:10.33155/j.ramd.2017.007.003 · Cited by 3
Effect of intermittent infusion hemodiafiltration on cerebral and hepatic oxygenation
Ookawara, S., Ito, K., Fukuda, K., Iida, T., Yahagi, K., Miyazawa, H., Hirai, K., Yoshizawa, M., & Morishita, Y. (2025) · Renal Replacement Therapy · doi:10.1186/s41100-024-00598-0 · Cited by 3
Applications of adsorption microcalorimetry in heterogeneous catalysis
Liu, Y., Bai, Y., Yuan, Z., & Huang, W. (2025) · Materials Today Nano · doi:10.1016/j.mtnano.2025.100737 · Cited by 3
Improvement of peripheral microcirculation after cardioversion of atrial fibrillation
Quast, D. R., Hummel, T., Wutzler, A., & Meier, J. J. (2019) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13723 · Cited by 3
Diagnosticité des mesures physiologiques périphériques de la charge mentale
Parent, M. (2019) · Corpus Université Laval (Université Laval) · Cited by 3
Bourdillon, N., Aebi, M. R., Bron, D., & Millet, G. P. (2025) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00984.2024 · Cited by 3
Machado, A. (2010) · PolyPublie (École Polytechnique de Montréal) · Cited by 3
Diving behaviour and physiology of the Korean Haenyeo
McKnight, J. C., Solms, B., Jensen, M., Turnbull, J., Balfour, S., Laagland, M., Bronkhorst, M., Lee, H., Kang, G., Lee, J. Y., et al. (2025) · Current Biology · doi:10.1016/j.cub.2025.06.066 · Cited by 3
Xing, W., Wang, X., Ma, Z., Xing, Y., Dun, X., & Cheng, X. (2025) · Optics · doi:10.3390/opt6040052 · Cited by 3
Taher, S. R., & Hamad, W. M. (2024) · Bulletin of the Chemical Society of Ethiopia · doi:10.4314/bcse.v38i6.25 · Cited by 3
Singh, S. P., Choudhury, M., Chowdhury, U. K., & Chauhan, S. (2014) · Indian Journal of Clinical Anaesthesia · Cited by 3
Kılınç, L., Türk, H. Ş., Sayın, P., Cinar, S., Demir, M., & İslamoğlu, S. (2021) · Türk anesteziyoloji ve reanimasyon derneği dergisi · doi:10.5152/tjar.2020.153 · Cited by 3
Sadler, C. A., Brett, K. D., Heerboth, A., Swisher, A. R., Mehregani, N., Touriel, R., & Cannon, D. T. (2020) · Diving and Hyperbaric Medicine Journal · doi:10.28920/dhm50.4.356-362 · Cited by 3
Preparation of CuO/Ag rough nanostructures as SERS-active substrates
Yang, Q., Wang, J., Wu, H., & Li, C. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/2011/1/012055 · Cited by 3
Near-infrared spectroscopy—current status
Singh, G. P. (2016) · Journal of Neuroanaesthesiology and Critical Care · doi:10.4103/2348-0548.174740 · Cited by 3
Towards the Exploitation of Mental Workload in Virtual Reality
Luong, T. (2021) · theses.fr (ABES) · doi:10.70675/7aa0dc1cz7df9z4656z874aza4857314abcd · Cited by 2
Kwong, W.-H., Li, J., Lui, C.-H., Luk, H. T., Lau, K.-F., Seaby, R., & Sidarta, A. (2024) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk9030161 · Cited by 2
Chen, Y.-Y. (2025) · Chemometrics and Intelligent Laboratory Systems · doi:10.1016/j.chemolab.2025.105583 · Cited by 2
Romero‐Arenas, S., Quero-Calero, C. D., Abellán‐Aynés, O., Andreu‐Caravaca, L., Fernandez-Calero, M., Manonelles, P., & López-Plaza, D. (2023) · Sports · doi:10.3390/sports11110212 · Cited by 2
Yang, C.-C., Yang, P.-C., Chen, J.-J. J., Lai, Y.-H., Hu, C.-H., Chang, Y., Tu, S. J., & Guo, L.-Y. (2020) · Sensors · doi:10.3390/s20082197 · Cited by 2
Metadata
- Authors
- Ferrari, M., Mottola, L., & Quaresima, V.
- Affiliations
- University of L'Aquila (IT)
- Casa Sollievo della Sofferenza (IT)
- Kyoto University (JP)
- Venue
- Canadian Journal of Applied Physiology
- Publisher
- Canadian Science Publishing
- Published
- 2004-08-01
- Volume
- 29
- Issue
- 4
- Pages
- 463-487
- ISSN
- 1066-7814 (ISSN-L)
- OpenAlex
- W2130603606
- Semantic Scholar
- bd62a0617aa90919c1ddae952300dc20d128d7da
- Cited by
- 997
- References
- 114
- Citations by year
- 2026: 35 · 2025: 51 · 2024: 44 · 2023: 58 · 2022: 53 · 2021: 46 · 2020: 53 · 2019: 55 · 2018: 54 · 2017: 63 · 2016: 48 · 2015: 52 · 2014: 36 · 2013: 56 · 2012: 68
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.nrcresearchpress.com/page/about/CorporateTextAndDataMining (tdm)
- Locations
- Canadian Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
- Funders
- U.S. Food and Drug Administration
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- near-infrared spectroscopy, tissue oxygen saturation, hemoglobin, myoglobin, muscle oxygen consumption, cerebral blood flow, brain energy metabolism, cortical activation, cytochrome c oxidase, light scattering, exercise physiology, non-invasive optical measurement
- MeSH terms
- Blood Volume, Cerebral Cortex, Cerebrovascular Circulation, Humans, Oximetry, Oxygen Consumption, Regional Blood Flow, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.