Principles, Techniques, and Limitations of Near Infrared Spectroscopy
The DOI matches its Crossref record; 114 of the 114 references it cites were found in a registry or an index.
Abstract
In the last decade the study of the human brain and muscle energetics underwent a radical change, thanks to the progressive introduction of noninvasive techniques, including near-infrared (NIR) spectroscopy (NIRS). This review summarizes the most recent literature about the principles, techniques, advantages, limitations, and applications of NIRS in exercise physiology and neuroscience. The main NIRS instrumentations and measurable parameters will be reported. NIR light (700-1000 nm) penetrates superficial layers (skin, subcutaneous fat, skull, etc.) and is either absorbed by chromophores (oxy- and deoxyhemoglobin and myoglobin) or scattered within the tissue. NIRS is a noninvasive and relatively low-cost optical technique that is becoming a widely used instrument for measuring tissue O 2 saturation, changes in hemoglobin volume and, indirectly, brain/muscle blood flow and muscle O 2 consumption. Tissue O 2 saturation represents a dynamic balance between O 2 supply and O 2 consumption in the small vessels such as the capillary, arteriolar, and venular bed. The possibility of measuring the cortical activation in response to different stimuli, and the changes in the cortical cytochrome oxidase redox state upon O 2 delivery changes, will also be mentioned. Key words: tissue oximetry, oxidative metabolism, optical imaging, blood flow, oxygen consumption, exercise physiology
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These values are in a large part representative of tissue capillaries, arterioles, and venules because, in larger blood vessels, NIR light is fully absorbed by the high hemoglobin concentration. 4”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [4]
In the citing paper
“Furthermore, small differences in ambient and muscular temperature may influence day-today variability, 4 as may slight changes in posture. 38”
From Performance comparison of the MOXY and PortaMon near-infrared spectroscopy muscle oximeters at rest and during exercise (2018) · cites this paper as [4]
In the citing paper
“Optical and spectroscopic sensors that meet these criteria, include UV [4], mid-and near-infrared [8], Raman [9], and fluorescence [5] spectroscopy.”
From Spectroscopic Advances in Real Time Monitoring of Pharmaceutical Bioprocesses: A Review of Vibrational and Fluorescence Techniques (2025) · cites this paper as [8]
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Strangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Recent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114
Non-invasive neuroimaging using near-infrared light
Strangman, G., Boas, D. A., & Sutton, J. P. (2002) · Biological Psychiatry · doi:10.1016/s0006-3223(02)01550-0 · Cited by 903
Beyond the Visible???Imaging the Human Brain With Light
Obrig, H., & Villringer, A. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200301000-00001 · Cited by 892
Owen-Reece, H., Smith, M., Elwell, C. E., & Goldstone, J. C. (1999) · British Journal of Anaesthesia · doi:10.1093/bja/82.3.418 · Cited by 688
Spontaneous Low Frequency Oscillations of Cerebral Hemodynamics and Metabolism in Human Adults
Obrig, H., Neufang, M., Wenzel, R., Kohl, M., Steinbrink, J., Einhäupl, K., & Villringer, A. (2000) · NeuroImage · doi:10.1006/nimg.2000.0657 · Cited by 614
Wittenberg, J. B., & Wittenberg, B. A. (2003) · Journal of Experimental Biology · doi:10.1242/jeb.00243 · Cited by 550
Functional near‐infrared optical imaging: Utility and limitations in human brain mapping
Hoshi, Y. (2003) · Psychophysiology · doi:10.1111/1469-8986.00053 · Cited by 532
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Research works printed but not linked: 5
- Bangsbo J., 2000, Am. J. Physiol., 279, R899
- McCully K.K., 2000, Exerc. Sport Sci. Rev., 28, 123
- Richardson R.S., 2002, Am. J. Physiol., 283, R1131
- Springett R., 2000, Am. J. Physiol., 279, H2202
- Tran T.K., 1999, Am. J. Physiol., 276, R1682
Cited by
Items 801–900 of 1,000
French, C., Robbins, D., Gernigon, M., & Gordon, D. A. (2025) · Microvascular Research · doi:10.1016/j.mvr.2025.104811 · Cited by 2
Caterini, J. E., Rendall, K., Cifra, B., Schneiderman, J. E., Ratjen, F. A., Seed, M., Rayner, T., Weiss, R., McCrindle, B. W., Noseworthy, M. D., et al. (2022) · Physiological Reports · doi:10.14814/phy2.15182 · Cited by 2
Mbihayeimaana, J., Pfumorodze, J., Nuwamanya, E., Sseremba, G., Kyaligonza, V., Iragaba, P., Kanaabi, M., & Madzimure, J. (2026) · Plants · doi:10.3390/plants15142117 · Cited by 2
Effects of Sleep Debt on Cognitive Performance and Prefrontal Activity in Humans
Kuriyama, K., & Honm, M. (2012) · InTech eBooks · doi:10.5772/36245 · Cited by 2
Domínguez, P. R. (2013) · Medical Hypotheses · doi:10.1016/j.mehy.2013.11.014 · Cited by 2
Vascular function in the aging human brain during muscle exertion
Zhu, M., Lee, T. X. Y., Hsieh, Y., Lai, L.-F., Condello, G., Donnelly, C. J., Smith, M. K., Hamzah, S. H., Lim, B.-H., Huang, C., et al. (2022) · Aging · doi:10.18632/aging.204052 · Cited by 2
Defecation after magnesium supplementation enhances cognitive performance in triathletes
Wei, C.-C., Harris, M. B., Ye, M., Nicholls, A., AlKhatib, A. H., Dewi, L., Huang, C.-Y., & Kuo, C. (2024) · Sports Medicine and Health Science · doi:10.1016/j.smhs.2024.04.001 · Cited by 2
Dynamic contrast in dual-beam optical coherence tomography imaging of human skin
Pircher, M., Brunner, E. F., Nagelreiter, I., Kremslehner, C., Hu, W., Golabi, B., Freystätter, C., & Gruber, F. (2025) · Biomedical Optics Express · doi:10.1364/boe.570414 · Cited by 2
Feng, X., Knight, S. P., Connolly, E., Shirsath, M. A., Newman, L., Duggan, E., Kenny, R. A., & Romero‐Ortuño, R. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3488513 · Cited by 2
Roe, B. E., & Haab, T. C. (2007) · SSRN Electronic Journal · doi:10.2139/ssrn.1001336 · Cited by 2
Noninvasive brain imaging for experimental medicine in drug discovery
Matthews, P. M., & Wise, R. G. (2006) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.1.2.111 · Cited by 2
Spectroscopic Brain Imaging in Autism
Lainhart, J. E., Cooperrider, J. R., & Taylor, J. S. (2013) · Springer eBooks · doi:10.1007/978-1-4614-6843-1_9 · Cited by 2
Emerging nanoprobes for the features visualization of vulnerable atherosclerotic plaques
Wang, X., Mu, D., Liang, J., Xin, R., Zhang, Y., Liu, R., Yao, M., & Zhang, B. (2024) · Smart Medicine · doi:10.1002/smmd.20240033 · Cited by 2
Transcutaneous Bladder Spectroscopy: Computer Aided Near Infrared Monitoring of Physiologic Function
Macnab, A. J., Stothers, L. S., Shadgan, B., & Molavi, B. (2015) · Studies in computational intelligence · doi:10.1007/978-3-319-15720-7_20 · Cited by 2
Nakahachi, T., ISHII, R., Canuet, L., Sato, I., Kamibeppu, K., Iwase, M., Tanaka, H., & Naito, Y. (2019) · Research Square · doi:10.21203/rs.2.19602/v1 · Cited by 2
Ramsingh, D. S. (2013) · Springer eBooks · doi:10.1007/978-1-4614-8557-5_28 · Cited by 2
Guézennec, J., Correa, D., & Billaut, F. (2025) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2025-0247 · Cited by 2
Kanawade, R. V., Stelzle, F., & Schmidt, M. (2012) · Physics Procedia · doi:10.1016/j.phpro.2012.10.106 · Cited by 2
Effects of Acceleration-Induced Reductions in Retinal and Cerebral Oxygenation on Human Performance
Croft, R. J., Kölegård, R., Tribukait, A., Taylor, N. A. S., & Eiken, O. (2021) · Aerospace Medicine and Human Performance · doi:10.3357/amhp.5731.2021 · Cited by 2
Bouchon, C. (2014) · theses.fr (ABES) · doi:10.70675/59676842z6455z4be8zbad4z9934350653f0 · Cited by 2
Hirata, K., Shiozaki, D., Yamada, K., Miyokawa, Y., Yajima, Y., & Akagi, R. (2024) · Journal of Sports Sciences · doi:10.1080/02640414.2024.2423135 · Cited by 2
Exercise to improve blood flow and vascular health in the lower limbs of paraplegics
Burns, K. J. (2015) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 2
Muscle oxygenation during graded exercise in trained rowers
Lanigan, B. (n.d.) · Murdoch University Research Portal · Cited by 2
Improving fNIRS Signal Quality Using Smoothing Filtering
Kawala‐Sterniuk, A., Mikołajewski, D., Leiva, L. A., Ruotsalo, T., Łysiak, A., Grochowicz, B., Gorzeńariczyk, E. J., Luckiewicz, A., Wieczorek, A., & Pelc, M. (2023) · Progress in Applied Electrical Engineering (PAEE) · doi:10.1109/paee59932.2023.10244393 · Cited by 2
Pang, Q., Dong, Z., Deng, Z., Yang, D., Li, J., Yang, Y., & Chen, Z. (2026) · Journal of Food Measurement & Characterization · doi:10.1007/s11694-026-04216-x · Cited by 2
Clinical factors affecting cerebral oxygenation in patients undergoing peritoneal dialysis
Kitano, T., Ito, K., Ookawara, S., Hoshino, T., Hayasaka, H., Kofuji, M., Uchida, T., Morino, J., Minato, S., Kaneko, S., et al. (2021) · The International Journal of Artificial Organs · doi:10.1177/03913988211020017 · Cited by 2
The effect of haemoglobin and blood transfusion on preterm infant gut perfusion and injury
Howarth, C., Mifsud, C., Banerjee, J., Eaton, S. D., Leung, T. S., Fleming, P., Morris, J. K., & Aladangady, N. (2024) · Frontiers in Pediatrics · doi:10.3389/fped.2024.1440537 · Cited by 2
Utilisation du préconditionnement ischémique pour optimiser la performance aérobie chez l'athlète
Paradis‐Deschênes, P. (2021) · Corpus Université Laval (Université Laval) · Cited by 2
Zeller, J. B. M. (2011) · Online Publication Service of Würzburg University (Würzburg University) · Cited by 2
Brief Exposure To –2 G Z Reduces Cerebral Oxygenation In Response To Stand Test
Tran, C., Berthelot, M., Etienne, X., Beers, P. V., Dussault, C., & Jouanin, J. (2007) · Springer eBooks · doi:10.1007/978-0-387-71764-7_22 · Cited by 2
Free tissue transfer monitoring using a novel near infrared spectroscopy system
Mah, A. J. (2023) · cIRcle (University of British Columbia) · doi:10.14288/1.0435257 · Cited by 2
Willcocks, R. J. (2011) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 2
Basson, K. (2019) · SUNScholar (Stellenbosch University) · Cited by 2
DEVELOPMENT OF FUNCTIONAL STUDIES AND METHODS TO BETTER UNDERSTAND VISUAL FUNCTION
Kashou, N. H. (2008) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 2
Ghalavand, M., Hatami, J., Setarehdan, S. K., Nosrati, F., Ghalavand, H., & Nikhalat-Jahromi, A. (2024) · Research Square · doi:10.21203/rs.3.rs-4529870/v1 · Cited by 2
QUANTIFICATION OF CALF OXYGENATION IN PARAPLEGIC PATIENTS DURING PASSIVE LEG MOVEMENT
Quaresima, V., & Ferrari, M. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000183846.62185.87 · Cited by 2
Self-citationKlaessen, J. H. G. M., Noordmans, H. J., Nelisse, M., & Verdaasdonk, R. M. (2012) · International Conference on Quantitative InfraRed Thermography (QIRT) · doi:10.21611/qirt.2012.270 · Cited by 2
Probing Brain Oxygenation Wave-forms with Near Infrared Spectroscopy (NIRS)Preprint
Gersten, A., Perle, J., Heimer, D., Raz, A., & Fried, R. (2016) · arXiv (Cornell University) · doi:10.48550/arxiv.1612.08743 · Cited by 2
Harrison, M. F. (2009) · doi:10.82465/4850 · Cited by 2
Córdova-Manzo, J. F., Vega-Martínez, G., Vera, A., Leija, L., Quinzaños-Fresnedo, J., Durán-Ortiz, S., & Gutiérrez-Martínez, J. (2025) · Journal of Sensors · doi:10.1155/js/6494580 · Cited by 2
Xu, Y., Li, M., Feng, T., Jiao, L., Wu, F., Zhang, T., Tang, H., & Li, H. (2022) · Chemical Research in Chinese Universities · doi:10.1007/s40242-022-1327-3 · Cited by 2
Khurana, A., Khodavandi, A., Tehrani, I. A., & Shadgan, B. (2025) · Biomedical Optics Express · doi:10.1364/boe.572790 · Cited by 2
DWT-SVM on Near-Infrared Spectra for Moisture and Volatile Determination of Coal
Yang, X. L., Wang, F., Chen, J. S., & Zhang, S. H. (2013) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.483.71 · Cited by 2
In vivo study on NIR light propagation in the human head
Karthikeyan, P., Honka, U., Ilvesmäki, M., Ferdinando, H., Korhonen, V. O., & Myllylä, T. (2022) · Saratov Fall Meeting: Optical and Nanotechnologies for Biology and Medicine (SFM) · doi:10.1117/12.2626380 · Cited by 2
Valenciaga, D., Simoes, E. D. O., O., O. L., Chongo, B., Oramas, A., & Cairo, J. (2007) · Redalyc (Universidad Autónoma del Estado de México) · Cited by 2
Yu, X., An, J., Yu, H., Shi, Y., Deng, Y. L., Zhou, J., & Xu, K. (2015) · Review of Scientific Instruments · doi:10.1063/1.4928496 · Cited by 2
Vastus Lateralis Metabolic Response to Explosive Maximal Isometric Leg Press Exercise
Quaresima, V., Crisostomi, S., Mottola, L., Angelozzi, M., Franco, A., Corsica, C., Calvisi, V., & Ferrari, M. (2006) · Springer eBooks · doi:10.1007/0-387-29540-2_27 · Cited by 2
Self-citationElectro-optical plethysmography for non-invasive estimation of hemoglobin concentration
Phillips, J. P., Hickey, M., & Kyriacou, P. A. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091079 · Cited by 2
Bu, S., Xie, S., Lu, J., Cao, X., Xiang, B., & Ye, Y. (2008) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.801 · Cited by 2
Modeling and experimental verification for a broad beam light transport in optical tomography
Janunts, E., Pöschinger, T., Eisa, F., & Langenbucher, A. (2010) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2010.06.005 · Cited by 2
Wearable sensor for continuously vigilant spatial and depth-resolved perfusion imaging
Mapar, B. D., Lam, Y., Mehrnia, A., Bates‐Jensen, B. M., Sarrafzadeh, M., & Kaiser, W. J. (2012) · Wireless Health · doi:10.1145/2448096.2448111 · Cited by 2
Yang, X. L., & Wang, F. (2014) · Advanced materials research · doi:10.4028/www.scientific.net/amr.898.831 · Cited by 2
MOCARTS: A lightweight radiation transport simulator for easy handling of complex sensing geometries
Cuervo-Soto, B., Herrera-Vega, J., Garces-Baez, J. A. D. C., Treviño-Palacios, C. G., & Orihuela‐Espina, F. (2016) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2016.7493287 · Cited by 2
Noninvasive Neurophysiological Monitoring in Acute Ischemic Stroke Treatment
Campos, M. T. (2017) · Open access Journal of Neurology & Neurosurgery · doi:10.19080/oajnn.2017.04.555628 · Cited by 2
Sugiyama, T., Ito, K., Ookawara, S., Shimoyama, H., Shindo, M., Hirata, M., Shimoyama, H., NAKAZATO, Y., & Morishita, Y. (2023) · Scientific Reports · doi:10.1038/s41598-023-29879-0 · Cited by 2
Ookawara, S., Ito, K., Ueda, Y., Minato, S., Kaneko, S., Hirata, M., Kitano, T., Miyazawa, H., Hirai, K., & Morishita, Y. (2023) · The International Journal of Artificial Organs · doi:10.1177/03913988231168656 · Cited by 2
Demura, S., Yamaji, S., & Yamada, T. (2007) · Sport Sciences for Health · doi:10.1007/s11332-007-0042-2 · Cited by 2
Mie, M. B. (2011) · heiDOK (Heidelberg University) · doi:10.11588/heidok.00012151 · Cited by 2
Hu, X., Arredondo, M. M., Gomba, M., Confer, N., DaSilva, A. F. M., Johnson, T. D., Shalinsky, M. H., & Kovelman, I. (2020) · Journal of Biomedical Optics · doi:10.1117/1.jbo.25.5.059801 · Cited by 2
Effect of exercise intensity on oxygen consumption kinetics in non‐exercising muscle during exercise
Nagasawa, T. (2011) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2011.01073.x · Cited by 1
Consumer Decision Neuroscience: Ausgewählte Beiträge
Gier, N. R. (2022) · Springer eBooks · doi:10.1007/978-3-658-38206-3 · Cited by 1
Flodgren, G. (2007) · DiVA at Umeå University (Umeå University) · Cited by 1
van der Harst, J. J., Hijlkema, J., van der Werf, S., Elting, J. W. J., van Dijk, J. M. C., & Uyttenboogaart, M. (2026) · Acta Neurochirurgica · doi:10.1007/s00701-026-06901-8 · Cited by 1
González, C. C. O., Ranchod, S., & Rakobowchuk, M. (2024) · PLoS ONE · doi:10.1371/journal.pone.0312109 · Cited by 1
Franzone, I., Antonacci, Y., Giuliano, F., Pernice, R., Busacca, A., Faes, L., & Giaconia, G. C. (2025) · Entropy · doi:10.3390/e27070694 · Cited by 1
Wissler, E. H. (2018) · Springer eBooks · doi:10.1007/978-3-662-57397-6_4 · Cited by 1
McManus, C., Murray, K., Welbourn, E., Double, J., Chung, H., Waterworth, S., Jones, B., & Cooper, C. E. (2026) · PLoS ONE · doi:10.1371/journal.pone.0341963 · Cited by 1
Muscle Oxygenation Threshold in More and Less Active Muscles and 3,000-m Running Pace
Cirino, C., Breda, F. L., Polisel, E. E. C., Lourenço, T. F., Papoti, M., Gobatto, C. A., & Manchado-Gobatto, F. D. B. (2025) · International Journal of Sports Medicine · doi:10.1055/a-2611-3388 · Cited by 1
Bradley, A., Roehl, A. S., Smith, J., McGrath, R. P., & Hackney, K. J. (2023) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2023.1210880 · Cited by 1
Interplay Among Muscle Oxygen Saturation, Activation, and Power on a Swim-Bench
Coloretti, V., Quagliarotti, C., Gatta, G., Piacentini, M. F., Cortesi, M., & Fantozzi, S. (2025) · Sensors · doi:10.3390/s25134148 · Cited by 1
EFFECTS OF PHYSICAL ACTIVITY ON AGE-RELATED DECLINE IN OXYGEN DELIVERY TO WORKING MUSCLES
Ichimura, S., Murase, N., Osada, T., Kime, R., Homma, T., Ueda, C., Nagasawa, T., Motobe, M., Hamaoka, T., & Katsumura, T. (2006) · 体力科學 · doi:10.7600/jspfsm.55.s217 · Cited by 1
Waltz, X. (2012) · theses.fr (ABES) · doi:10.70675/c26ef9f6z4e33z44e5z9596z2270038edfd8 · Cited by 1
Zhu, L., & Zhu, G. (2023) · Journal of Nanoelectronics and Optoelectronics · doi:10.1166/jno.2023.3451 · Cited by 1
Feng, X., & Romero‐Ortuño, R. (2025) · Sensors · doi:10.3390/s25113548 · Cited by 1
Huang, X., & Madoc, A. C. (2017) · IEEE International Conference on Communication Software and Networks · doi:10.1109/iccsn.2017.8230240 · Cited by 1
OCCLUSIVE CEREBROVASCULAR DISEASE
Herrick, I. A., Higashida, R. T., & Gelb, A. W. (2010) · Elsevier eBooks · doi:10.1016/b978-0-323-05908-4.10021-1 · Cited by 1
Defecation enhances cerebral perfusion and delays fatigue in elite triathletes
Wei, C.-C., Condello, G., Yang, A., Yu, S.-H., Liao, Y., Chen, C., Hsu, C.-C., Huang, C.-Y., & Kuo, C. (2023) · Journal of the International Society of Sports Nutrition · doi:10.1080/15502783.2023.2206380 · Cited by 1
Amyar, H. (2023) · theses.fr (ABES) · doi:10.70675/2967c725z8610z40aez8bddz6803dcccb861 · Cited by 1
Clancy, M. T. (2017) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 1
Gómez‐Pesquera, E. (2016) · UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) · doi:10.35376/10324/22090 · Cited by 1
Changes in Small Intestinal Oxygenation During Hemodialysis: A Case Report
Watanabe, Y., Ito, K., Nonaka, H., Honma, S., Asano, Y., Morishita, Y., & Ookawara, S. (2026) · Kidney International Case Reports · doi:10.1016/j.kintcr.2026.100010 · Cited by 1
Dopierała, A., Przewodzka, A., & Tomalski, P. (2020) · The Polish Journal of Aviation Medicine Bioengineering and Psychology · doi:10.13174/pjambp.15.12.2020.03 · Cited by 1
Effects of Moderate Altitude Training Combined with Moderate or High-altitude Residence
Ušaj, A., Kapus, J., Štrumbelj, B., Debevec, T., & Vodičar, J. (2022) · International Journal of Sports Medicine · doi:10.1055/a-1885-4053 · Cited by 1
Simões, R. P., Goulart, C. D. L., Caruso, F., Garcia-Araújo, A. S., de Moura, S. C. G., Catai, A. M., dos Santos, P. B., Camargo, P. F., Marinho, R. S., Mendes, R. G., et al. (2023) · The American Journal of the Medical Sciences · doi:10.1016/j.amjms.2023.05.005 · Cited by 1
Prefrontal NIRS signal is unaffected by forehead Doppler flux during incremental cycling exercise
Hartman, M. E. (2023) · Clinical Physiology and Functional Imaging · doi:10.1111/cpf.12837 · Cited by 1
Rad, A. P. P., Levandier, V., Nourizadeh, M., Jahanshahi, K., Bégin, J., & Shadgan, B. (2025) · Biophotonics in Exercise Science, Sports Medicine, Health Monitoring Technologies, and Wearables · doi:10.1117/12.3040846 · Cited by 1
Normandin, L., Guézennec, J., Paradis‐Deschênes, P., & Billaut, F. (2026) · Journal of Sports Sciences · doi:10.1080/02640414.2026.2637208 · Cited by 1
Hernandez-Sarabia, J. A., Schmid, A. A., & Stephens, J. A. (2025) · Brain Sciences · doi:10.3390/brainsci15101049 · Cited by 1
Tabari, F. (2020) · Hispana · Cited by 1
Development of stainless cardiac histology of clinical biopsy samples with infrared spectroscopy
Tiwari, S. (2016) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign) · Cited by 1
Philippe, K. (2022) · theses.fr (ABES) · doi:10.70675/7efd56c0z35e0z4261z8591z0c49fc283dce · Cited by 1
Colosio, M., Pilotto, A., Ansaldo, M., Dobrzycki, I., Pellegrino, M. A., Bottinelli, R., Re, R., Botter, A., Franchi, M. V., Sundberg, C. W., et al. (2026) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00279.2026 · Cited by 1
Emotional speech and affective touch processing in children less than 2 years of age
Maria, A. (2019) · UTUPub (University of Turku) · Cited by 1
Lucero, A. A. (2021) · Massey Research Online (Massey University) · Cited by 1
Gabbard, R. D. (2017) · CORE Scholar (Wright State University) · Cited by 1
Language processing in cochlear implant users using fNIRS
Zhou, X. (2018) · Minerva Access (University of Melbourne) · Cited by 1
Osawa, T., Arimitsu, T., & Takahashi, H. (2016) · Advances in experimental medicine and biology · doi:10.1007/978-1-4939-3023-4_3 · Cited by 1
O2 Saturation in the Intercostal Space During Moderate and Heavy Constant-Load Exercise
Osawa, T., Kime, R., Fujioka, M., Osada, T., Murase, N., & Katsumura, T. (2013) · Advances in experimental medicine and biology · doi:10.1007/978-1-4614-7411-1_20 · Cited by 1
Li, T., Zhang, Z. L., & Zheng, Y. (2011) · Applied Mechanics and Materials · doi:10.4028/www.scientific.net/amm.138-139.553 · Cited by 1
The Effect of Acupuncture on Muscle Blood Volume and Oxygenation
Ohkubo, M., Hamaoka, T., Kaneko, Y., Katsumura, T., & Sakamoto, A. (2011) · InTech eBooks · doi:10.5772/23773 · Cited by 1
Metadata
- Authors
- Ferrari, M., Mottola, L., & Quaresima, V.
- Affiliations
- University of L'Aquila (IT)
- Casa Sollievo della Sofferenza (IT)
- Kyoto University (JP)
- Venue
- Canadian Journal of Applied Physiology
- Publisher
- Canadian Science Publishing
- Published
- 2004-08-01
- Volume
- 29
- Issue
- 4
- Pages
- 463-487
- ISSN
- 1066-7814 (ISSN-L)
- OpenAlex
- W2130603606
- Semantic Scholar
- bd62a0617aa90919c1ddae952300dc20d128d7da
- Cited by
- 997
- References
- 114
- Citations by year
- 2026: 35 · 2025: 51 · 2024: 44 · 2023: 58 · 2022: 53 · 2021: 46 · 2020: 53 · 2019: 55 · 2018: 54 · 2017: 63 · 2016: 48 · 2015: 52 · 2014: 36 · 2013: 56 · 2012: 68
- FWCI
- 4.61
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.nrcresearchpress.com/page/about/CorporateTextAndDataMining (tdm)
- Locations
- Canadian Journal of Applied Physiology (publishedVersion)
- PubMed (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi dell Aquila (submittedVersion)
- Funders
- U.S. Food and Drug Administration
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Keywords
- near-infrared spectroscopy, tissue oxygen saturation, hemoglobin, myoglobin, muscle oxygen consumption, cerebral blood flow, brain energy metabolism, cortical activation, cytochrome c oxidase, light scattering, exercise physiology, non-invasive optical measurement
- MeSH terms
- Blood Volume, Cerebral Cortex, Cerebrovascular Circulation, Humans, Oximetry, Oxygen Consumption, Regional Blood Flow, Muscle, Skeletal, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.