Sensor networks have the potential to greatly impact many aspects of medical care. By outfitting patients with wireless, wearable vital sign sensors, collecting detailed real-time data on physiological status can be greatly simplified. However, there is a significant gap between existing sensor network systems and the needs of medical care. In particular, medical sensor networks must support multicast routing topologies, node mobility, a wide range of data rates and high degrees of reliability, and security. This paper describes our experiences with developing a combined hardware and software platform for medical sensor networks, called CodeBlue. CodeBlue provides protocols for device discovery and publish/subscribe multihop routing, as well as a simple query interface that is tailored for medical monitoring. We have developed several medical sensors based on the popular MicaZ and Telos mote designs, including a pulse oximeter, EKG and motion-activity sensor. We also describe a new, miniaturized sensor mote designed for medical use. We present initial results for the CodeBlue prototype demonstrating the integration of our medical sensors with the publish/subscribe routing substrate. We have experimentally validated the prototype on our 30-node sensor network testbed, demonstrating its scalability and robustness as the number of simultaneous queries, data rates, and transmitting sensors are varied. We also study the effect of node mobility, fairness across multiple simultaneous paths, and patterns of packet loss, confirming the system’s ability to maintain stable routes despite variations in node location and
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
RADAR: an in-building RF-based user location and tracking system
Bahl, P., & Padmanabhan, V. N. (2002) · Proceedings IEEE INFOCOM 2000. Conference on Computer Communications. Nineteenth Annual Joint Conference of the IEEE Computer and Communications Societies (Cat. No.00CH37064) · doi:10.1109/infcom.2000.832252 · Cited by 8,380 · cited 1×
“MoteTrack improves upon systems such as RADAR [2] in that it does not require a central server to maintain the signature database; rather, this information is stored on the set of beacon nodes that are distributed throughout the area (e.”
Directed diffusion: a scalable and robust communication paradigm for sensor networks
Intanagonwiwat, C., Govindan, R., & Estrin, D. (2000) · Proceedings of the 6th annual international conference on Mobile computing and networking · doi:10.1145/345910.345920 · Cited by 5,393
A high-throughput path metric for multi-hop wireless routing
De Couto, D. S. J., Aguayo, D., Bicket, J., & Morris, R. (2003) · Proceedings of the 9th annual international conference on Mobile computing and networking · doi:10.1145/938985.939000 · Cited by 3,356
System architecture directions for networked sensors
Hill, J., Szewczyk, R., Woo, A., Hollar, S., Culler, D., & Pister, K. (2000) · ACM SIGPLAN Notices · doi:10.1145/356989.356998 · Cited by 3,084
TAG: a Tiny AGgregation service for ad-hoc sensor networks
Madden, S., Franklin, M. J., Hellerstein, J. M., & Hong, W. (2002) · ACM SIGOPS Operating Systems Review · doi:10.1145/844128.844142 · Cited by 2,719
Fine-grained network time synchronization using reference broadcasts
Elson, J., Girod, L., & Estrin, D. (2002) · ACM SIGOPS Operating Systems Review · doi:10.1145/844128.844143 · Cited by 2,396
The flooding time synchronization protocol
Maróti, M., Kusy, B., Simon, G., & Lédeczi, Á. (2004) · Proceedings of the 2nd international conference on Embedded networked sensor systems · doi:10.1145/1031495.1031501 · Cited by 2,183
Telos: enabling ultra-low power wireless research
Polastre, J., Szewczyk, R., & Culler, D. (2005) · Cited by 1,735
TinySec: a link layer security architecture for wireless sensor networks
Karlof, C., Sastry, N., & Wagner, D. (2004) · Proceedings of the 2nd international conference on Embedded networked sensor systems · doi:10.1145/1031495.1031515 · Cited by 1,612
Taming the underlying challenges of reliable multihop routing in sensor networks
Woo, A., Tong, T., & Culler, D. (2003) · Proceedings of the 1st international conference on Embedded networked sensor systems · doi:10.1145/958491.958494 · Cited by 1,512
Cited by
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296
“Researchers in Harvard University have developed CodeBlue [37], a medical sensor network platform for multipatient monitoring environments based on the ZigBee compliant MicaZ and Telos motes, including custom designed biosensor boards for pulse oximetry, three-lead ECG, EMG, and motion activity.”
MethodWireless Body Area Networks: A Survey
Movassaghi, S., Abolhasan, M., Lipman, J., Smith, D., & Jamalipour, A. (2014) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2013.121313.00064 · Cited by 1,538
Wireless sensor networks for healthcare: A survey
Alemdar, H., & Ersoy, C. (2010) · Computer Networks · doi:10.1016/j.comnet.2010.05.003 · Cited by 1,427
Chen, M., Gonzalez, S., Vasilakos, A., Cao, H., & Leung, V. C. M. (2011) · Mobile Networks and Applications · doi:10.1007/s11036-010-0260-8 · Cited by 1,352
A survey on ambient-assisted living tools for older adults
Rashidi, P., & Mihailidis, A. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2012.2234129 · Cited by 1,128
Wireless sensor networks: a survey on recent developments and potential synergies
Rawat, P., Singh, K. D., Chaouchi, H., & Bonnin, J. M. (2014) · The Journal of Supercomputing · doi:10.1007/s11227-013-1021-9 · Cited by 1,054
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
A Survey on Ambient Intelligence in Healthcare
Acampora, G., Cook, D. J., Rashidi, P., & Vasilakos, A. V. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2262913 · Cited by 630
Enabling technologies for wireless body area networks: A survey and outlook
Cao, H., Leung, V., Chow, C., & Chan, H. (2009) · IEEE Communications Magazine · doi:10.1109/mcom.2009.5350373 · Cited by 518
Remote health monitoring of elderly through wearable sensors
Al-khafajiy, M., Baker, T., Chalmers, C., Asim, M., Kolivand, H., Fahim, M., & Waraich, A. (2019) · Multimedia Tools and Applications · doi:10.1007/s11042-018-7134-7 · Cited by 365
They can hear your heartbeats: non-invasive security for implantable medical devices
Gollakota, S., Hassanieh, H., Ransford, B., Katabi, D., & Fu, K. (2011) · Proceedings of the ACM SIGCOMM 2011 conference · doi:10.1145/2018436.2018438 · Cited by 331
Ensuring Safety, Security, and Sustainability of Mission-Critical Cyber–Physical Systems
Banerjee, A., Venkatasubramanian, K. K., Mukherjee, T., & Gupta, S. K. S. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165689 · Cited by 318
Security and privacy issues in implantable medical devices: A comprehensive survey
Camara, C., Peris-Lopez, P., & Tapiador, J. E. (2015) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2015.04.007 · Cited by 293
The Advanced Health and Disaster Aid Network: A Light-Weight Wireless Medical System for Triage
Gao, T., Massey, T., Selavo, L., Crawford, D., Chen, B.-R., Lorincz, K., Shnayder, V., Hauenstein, L., Dabiri, F., Jeng, J., et al. (2007) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2007.910901 · Cited by 268
Self-citationContext-Sensitive Access in Industrial Internet of Things (IIoT) Healthcare Applications
Al-Turjman, F., & Alturjman, S. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2808190 · Cited by 264
Review of Cyber-Physical System in Healthcare
Haque, S. A., Aziz, S. M., & Rahman, M. (2014) · International Journal of Distributed Sensor Networks · doi:10.1155/2014/217415 · Cited by 262
An ultra-wearable, wireless, low power ECG monitoring system
Park, C., Chou, P. H., Bai, Y., Matthews, R., & Hibbs, A. (2006) · 2006 IEEE Biomedical Circuits and Systems Conference · doi:10.1109/biocas.2006.4600353 · Cited by 262
A Survey of Recent Developments in Home M2M Networks
Chen, M., Wan, J., Gonzalez, S., Liao, X., & Leung, V. C. M. (2014) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2013.110113.00249 · Cited by 259
Big data stream analysis: a systematic literature review
Kolajo, T., Daramola, O., & Adebiyi, A. (2019) · Journal of Big Data · doi:10.1186/s40537-019-0210-7 · Cited by 259
Ubiquitous WSN for Healthcare: Recent Advances and Future Prospects
Zhang, Y., Sun, L., Song, H., & Cao, X. (2014) · IEEE Internet of Things Journal · doi:10.1109/jiot.2014.2329462 · Cited by 257
Wearable Wireless Health Monitoring: Current Developments, Challenges, and Future Trends
Soh, P. J., Vandenbosch, G. A. E., Mercuri, M., & Schreurs, D. M. M.-P. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2015.2394021 · Cited by 253
“The CodeBlue project developed by researchers at Harvard University [52] addressed issues of reliable communication between medical sensors, multiple receivers carried by health personnel, and various high data rates.”
BackgroundSoK: Security and Privacy in Implantable Medical Devices and Body Area Networks
Rushanan, M., Rubin, A. D., Kune, D. F., & Swanson, C. M. (2014) · 2014 IEEE Symposium on Security and Privacy · doi:10.1109/sp.2014.40 · Cited by 244
“We give concluding remarks in Section VII.”
A survey on health monitoring systems for health smart homes
Mshali, H., Lemlouma, T., Moloney, M., & Magoni, D. (2018) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2018.02.002 · Cited by 239
“These sensors, like ECG, pulse, blood pressure and oxygen saturation, were developed in the CodeBlue project [191].”
MEDiSN: Medical emergency detection in sensor networks
Ko, J., Lim, J. H., Chen, Y., Musvaloiu-E, R., Terzis, A., Masson, G. M., Gao, T., Destler, W., Selavo, L., & Dutton, R. P. (2010) · ACM Transactions on Embedded Computing Systems · doi:10.1145/1814539.1814550 · Cited by 233
“Comparing these results to those reported for mobile PMs in CodeBlue [Shnayder et al. 2005] (50%-80”
InfluentialRPL-Based Routing Protocols in IoT Applications: A Review
Kharrufa, H., Al-Kashoash, H. A. A., & Kemp, A. H. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2910881 · Cited by 230
“The same applies for fall detection applications [10], telecare [11], elderly and patient monitoring [12]–[14] and status and activity detection [15]–[17].”
BackgroundHuang, Y., Hsieh, M., Chao, H., Hung, S., & Park, J. (2009) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2009.090505 · Cited by 229
“For example, the CodeBlue project [3] developed a range of small and wearable wireless vital sign sensors based on the Mica2, MicaZ, and Telos commonlyused sensor platforms [5]-[8].”
MethodDevelopment and Evaluation of an Ambulatory Stress Monitor Based on Wearable Sensors
Choi, J., Ahmed, B., & Gutierrez-Osuna, R. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2011.2169804 · Cited by 221
“This configuration, known as a star topology, has been used in body sensor networks [25].”
MethodKalid, N., Zaidan, A. A., Zaidan, B. B., Salman, O. H., Hashim, M., & Muzammil, H. (2018) · Journal of Medical Systems · doi:10.1007/s10916-017-0883-4 · Cited by 213
A comprehensive review of wireless body area network
Hasan, K., Biswas, K., Ahmed, K., Nafi, N. S., & Islam, M. S. (2019) · Journal of Network and Computer Applications · doi:10.1016/j.jnca.2019.06.016 · Cited by 209
Recent progress in tactile sensors and their applications in intelligent systems
Liu, Y., Bao, R., Tao, J., Li, J., Dong, M., & Pan, C. (2020) · Science Bulletin · doi:10.1016/j.scib.2019.10.021 · Cited by 208
“Good biodegradability can avoid secondary surgery for patients, which makes the treatment of diseases safer, simpler and more reliable [83].”
BackgroundReTrust: Attack-Resistant and Lightweight Trust Management for Medical Sensor Networks
He, D., Chen, C., Chan, S., Bu, J., & Vasilakos, A. V. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2194788 · Cited by 205
“Alternatively, the CodeBlue project [23] stipulates that body sensors directly communicate with the BS without involving any actuator node.”
BackgroundAlam, M., & Hamida, E. (2014) · Sensors · doi:10.3390/s140509153 · Cited by 201
Transmission Power Control in Body Area Sensor Networks for Healthcare Monitoring
Xiao, S., Dhamdhere, A., Sivaraman, V., & Burdett, A. (2009) · IEEE Journal on Selected Areas in Communications · doi:10.1109/jsac.2009.090105 · Cited by 201
“Typical prototype devices in use today, such as MicaZ motes [1] used in Harvard’s CodeBlue [2] project, operate on a pair of AA batteries that provide a few Watt-hours (a few tens of kilo-Joules) of energy.”
MethodA Hospital Healthcare Monitoring System Using Wireless Sensor Networks
Aminian, M. (2013) · Journal of Health & Medical Informatics · doi:10.4172/2157-7420.1000121 · Cited by 200
IoT technologies for embedded computing: a survey
Samie, F., Bauer, L., & Henkel, J. (2016) · Proceedings of the Eleventh IEEE/ACM/IFIP International Conference on Hardware/Software Codesign and System Synthesis · doi:10.1145/2968456.2974004 · Cited by 190
“◦ EMG: To measure the electrical signal causes by muscular activity [49] for gesture recognition, detection of neuromuscular diseases, etc.”
BackgroundMethodXiong, H., & Qin, Z. (2015) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2015.2414399 · Cited by 184
“Possible applications of WBANs range from long-term daily living monitoring to location tracking and medical status monitoring [6], [7].”
BackgroundBody Area Networks for Ubiquitous Healthcare Applications: Opportunities and Challenges
Jovanov, E., & Milenkovic, A. (2011) · Journal of Medical Systems · doi:10.1007/s10916-011-9661-x · Cited by 183
“Following first academic prototypes of WBANs [1][5] [6][16], a number of commercial systems based on WBAN have emerged recently [17][18][19][20].”
BackgroundTowards a Comprehensive Data Analytics Framework for Smart Healthcare Services
Sakr, S., & Elgammal, A. (2016) · Big Data Research · doi:10.1016/j.bdr.2016.05.002 · Cited by 176
Capacitive Biopotential Measurement for Electrophysiological Signal Acquisition: A Review
Sun, Y., & Yu, X. B. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2519392 · Cited by 174
López, G., Custodio, V, & Moreno, J. I. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2058812 · Cited by 173
“Similar issues were also found and reported in [8].”
ResultMohammed, K. I., Zaidan, A. A., Zaidan, B. B., Albahri, O. S., Alsalem, M. A., Albahri, A. S., Hadi, A., & Hashim, M. (2019) · Journal of Medical Systems · doi:10.1007/s10916-019-1362-x · Cited by 171
Advances on localization techniques for wireless sensor networks: A survey
Chowdhury, T. J. S., Elkin, C., Devabhaktuni, V., Rawat, D. B., & Oluoch, J. (2016) · Computer Networks · doi:10.1016/j.comnet.2016.10.006 · Cited by 166
“Almost all of the recent medical technical devices like Ubimon [173], E-watch [4], CodeBlue [5], [6], Vital Sign Monitoring System [174], MobiHealth [3], Multi-Electrophysiological”
BackgroundPrognosis—A Wearable Health-Monitoring System for People at Risk: Methodology and Modeling
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2040085 · Cited by 136
“, systems based on 1) smarttextiles [18], [19]; 2) custom-designed platforms [20], [21]; 3) wireless sensor motes [22], [23]; and 4) Bluetooth-enabled biosensors and smart-phones [24], [25].”
Health Big Data Analytics: A Technology Survey
Harerimana, G., Jang, B., Kim, J. W., & Park, H. K. (2018) · IEEE Access · doi:10.1109/access.2018.2878254 · Cited by 119
“Pulse Oximetry Wearable heart rate (HR) and blood oxygen saturation (SpO2) Sensor networks for medical care [30]”
BackgroundData Analytics in Ubiquitous Sensor-Based Health Information Systems
Mukherjee, A., Pal, A., & Misra, P. (2012) · 2012 Sixth International Conference on Next Generation Mobile Applications, Services and Technologies · doi:10.1109/ngmast.2012.39 · Cited by 35
“The use of sensor networks for medical care has been highlighted in the CodeBlue platform[6].”
Method
Metadata
- Authors
- Shnayder, V., Chen, B.-R., Lorincz, K., Jones, T. R. F. F., & Welsh, M.
- Venue
- Proceedings of the 3rd international conference on Embedded networked sensor systems
- Publisher
- ACM
- Published
- 2005-11-02
- Pages
- 314-314
- OpenAlex
- W2001199719
- Cited by
- 720
- References
- 26
- FWCI
- 93.96
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.