UbiBreathe: A Ubiquitous non-Invasive WiFi-based Breathing Estimator
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Monitoring breathing rates and patterns helps in the diagnosis and potential avoidance of various health problems. Current solutions for respiratory monitoring, however, are usually invasive and/or limited to medical facilities. In this paper, we propose a novel respiratory monitoring system, UbiBreathe, based on ubiquitous off-the-shelf WiFi-enabled devices. Our experiments show that the received signal strength (RSS) at a WiFi-enabled device held on a person's chest is affected by the breathing process. This effect extends to scenarios when the person is situated on the line-of-sight (LOS) between the access point and the device, even without holding it. UbiBreathe leverages these changes in the WiFi RSS patterns to enable ubiquitous non-invasive respiratory rate estimation, as well as apnea detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
APACHE II: A severity of disease classification system
KNAUS, W. A., DRAPER, E. A., WAGNER, D. P., & ZIMMERMAN, J. E. (1985) · Critical Care Medicine · doi:10.1097/00003246-198510000-00009 · Cited by 13,664
APACHE II-A Severity of Disease Classification System: Reply
Knaus, W. A., Draper, E. A., Wagner, D. P., & Zimmerman, J. E. (1986) · Critical Care Medicine · doi:10.1097/00003246-198608000-00028 · Cited by 13,376
Harrison's Principles of Internal Medicine.
(1988) · Annals of Internal Medicine · doi:10.7326/0003-4819-108-3-499_2 · Cited by 12,514
Harrison's principles of internal medicine
(2008) · Choice Reviews Online · doi:10.5860/choice.46-0330 · Cited by 3,083
Non-contact, automated cardiac pulse measurements using video imaging and blind source separation
Poh, M.-Z., McDuff, D. J., & Picard, R. W. (2010) · Optics Express · doi:10.1364/oe.18.010762 · Cited by 1,643
Whole-home gesture recognition using wireless signals
Pu, Q., Gupta, S., Gollakota, S., & Patel, S. (2013) · Proceedings of the 19th annual international conference on Mobile computing & networking - MobiCom '13 · doi:10.1145/2500423.2500436 · Cited by 1,109
Challenges: device-free passive localization for wireless environments
Youssef, M., Mah, M., & Agrawala, A. (2007) · Proceedings of the 13th annual ACM international conference on Mobile computing and networking · doi:10.1145/1287853.1287880 · Cited by 780
Self-citationWiGest: A ubiquitous WiFi-based gesture recognition system
Abdelnasser, H., Youssef, M., & Harras, K. A. (2015) · 2015 IEEE Conference on Computer Communications (INFOCOM) · doi:10.1109/infocom.2015.7218525 · Cited by 552
Self-citationPhysiological parameter monitoring from optical recordings with a mobile phone
Scully, C. G., Lee, J., Meyer, J., Gorbach, A. M., Granquist-Fraser, D., Mendelson, Y., & Chon, K. H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2163157 · Cited by 452 · cited 1×
“The camera or sensor records the light absorbed by the finger tissue, and from that video, each frame is processed by splitting each pixel into RGB components whose values can be used to acquire a PPG signal [14,30,38].”
MethodANALYSIS OF VITAL SIGNS MONITORING USING AN IR-UWB RADAR
Lazaro, A., Girbau, D., & Villarino, R. (2010) · Progress In Electromagnetics Research · doi:10.2528/pier09120302 · Cited by 401
Nuzzer: A Large-Scale Device-Free Passive Localization System for Wireless Environments
Seifeldin, M., Saeed, A., Kosba, A. E., El-Keyi, A., & Youssef, M. (2013) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2012.106 · Cited by 365
Self-citationProgress In Electromagnetics Research
(2006) · Electromagnetic waves · doi:10.2528/pier60 · Cited by 341
McKenna, J. J., & McDade, T. (2005) · Paediatric Respiratory Reviews · doi:10.1016/j.prrv.2005.03.006 · Cited by 281
Sardy, S., Tseng, P., & Bruce, A. (2001) · IEEE Transactions on Signal Processing · doi:10.1109/78.923297 · Cited by 253
WiGest demo: A ubiquitous WiFi-based gesture recognition system
Abdelnasser, H., Harras, K. A., & Youssef, M. (2015) · 2015 IEEE Conference on Computer Communications Workshops (INFOCOM WKSHPS) · doi:10.1109/infcomw.2015.7179321 · Cited by 212
Self-citationInfluence of Respiratory Rate on Stroke Volume Variation in Mechanically Ventilated Patients
De Backer, D., Taccone, F. S., Holsten, R., Ibrahimi, F., & Vincent, J.-L. (2009) · Anesthesiology · doi:10.1097/aln.0b013e31819db2a1 · Cited by 207
RASID: A robust WLAN device-free passive motion detection system
Kosba, A. E., Saeed, A., & Youssef, M. (2012) · 2012 IEEE International Conference on Pervasive Computing and Communications · doi:10.1109/percom.2012.6199865 · Cited by 179
Self-citationInvestigating a smartphone imaging unit for photoplethysmography
Jonathan, E., & Leahy, M. (2010) · Physiological Measurement · doi:10.1088/0967-3334/31/11/n01 · Cited by 177
Signal-to-Noise Ratio in Doppler Radar System for Heart and Respiratory Rate Measurements
Droitcour, A. D., Boric-Lubecke, O., & Kovacs, G. T. A. (2009) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2009.2029668 · Cited by 162 · cited 2×
“Recently, a number of RF-based techniques, e.g. [5, 6, 9, 21, 29] have been proposed for contact-free breathing monitoring.”
BackgroundBreathfinding: A Wireless Network That Monitors and Locates Breathing in a Home
Patwari, N., Brewer, L., Tate, Q., Kaltiokallio, O., & Bocca, M. (2014) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2013.2287473 · Cited by 139
International Journal of Automation and Computing
(2013) · Machine Intelligence Research · doi:10.1007/11633.1751-8520 · Cited by 130
A novel method to detect Heart Beat Rate using a mobile phone
Pelegris, P., Banitsas, K., Orbach, T., & Marias, K. (2010) · 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology · doi:10.1109/iembs.2010.5626580 · Cited by 125
Ichnaea: A Low-Overhead Robust WLAN Device-Free Passive Localization System
Saeed, A., Kosba, A. E., & Youssef, M. A. (2013) · IEEE Journal of Selected Topics in Signal Processing · doi:10.1109/jstsp.2013.2287480 · Cited by 121
Self-citationACE: An Accurate and Efficient Multi-Entity Device-Free WLAN Localization System
Sabek, I., Youssef, M. A., & Vasilakos, A. V. (2014) · IEEE Transactions on Mobile Computing · doi:10.1109/tmc.2014.2320265 · Cited by 116
Self-citationMonoPHY: Mono-stream-based device-free WLAN localization via physical layer information
Abdelnasser, H., Samir, R., Sabek, I., & Youssef, M. A. (2013) · IEEE Wireless Communications and Networking Conference · doi:10.1109/wcnc.2013.6555311 · Cited by 106
Self-citationTowards resource sharing in mobile device clouds: power balancing across mobile devices
Mtibaa, A., Fahim, A., Harras, K. A., & Ammar, M. H. (2013) · Proceedings of the second ACM SIGCOMM workshop on Mobile cloud computing · doi:10.1145/2491266.2491276 · Cited by 103
Self-citationPropagation Modeling for Accurate Indoor WLAN RSS-Based Localization
El-Kafrawy, K., Youssef, M. A., El‐Keyi, A., & Naguib, A. F. (2010) · IEEE Vehicular Technology Conference · doi:10.1109/vetecf.2010.5594108 · Cited by 101
Self-citationTowards Computational Offloading in Mobile Device Clouds
Mtibaa, A., Harras, K. A., & Fahim, A. (2013) · IEEE International Conference on Cloud Computing Technology and Science · doi:10.1109/cloudcom.2013.50 · Cited by 91
Self-citationSynthetic Generation of Radio Maps for Device-Free Passive Localization
Eleryan, A., Elsabagh, M., & Youssef, M. A. (2011) · Globecom · doi:10.1109/glocom.2011.6134052 · Cited by 82
Self-citationDelmar's Comprehensive Medical Assisting: Administrative and Clinical Competencies
Lindh, W. Q. (1997) · Medical Entomology and Zoology · Cited by 81
Non-invasive respiration rate monitoring using a single COTS TX-RX pair
Kaltiokallio, O., Yi̇ği̇tler, H., Jäntti, R., & Patwari, N. (2014) · doi:10.5555/2602339.2602347 · Cited by 78
RASID: A Robust WLAN Device-free Passive Motion Detection SystemPreprint
Kosba, A. E., Saeed, A., & Youssef, M. A. (2011) · arXiv (Cornell University) · doi:10.48550/arxiv.1105.6084 · Cited by 73
Self-citationRate of respiration: the forgotten vital sign
Parkes, R. (2011) · Emergency Nurse · doi:10.7748/en2011.05.19.2.12.c8504 · Cited by 72
Analysis of a Device-Free Passive Tracking System in Typical Wireless Environments
Kosba, A. E., Abdelkader, A., & Youssef, M. A. (2009) · IFIP International Conference on New Technologies, Mobility and Security (NTMS) · doi:10.1109/ntms.2009.5384738 · Cited by 63
Self-citationRobust WLAN Device-free Passive motion detection
Kosba, A. E., Saeed, A., & Youssef, M. A. (2012) · IEEE Wireless Communications and Networking Conference · doi:10.1109/wcnc.2012.6214375 · Cited by 53
Self-citationNew insights into wifi-based device-free localization
Aly, H., & Youssef, M. A. (2013) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/2494091.2497612 · Cited by 48
Self-citationRF-Based device-free recognition of simultaneously conducted activities
Sigg, S., Shi, S., & Ji, Y. (2013) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/2494091.2497611 · Cited by 44
Multi-entity device-free WLAN localization
Sabek, I., & Youssef, M. A. (2012) · Globecom · doi:10.1109/glocom.2012.6503412 · Cited by 41
Self-citationComparison of selected parametric models for analysis of the photoplethysmographic signal
Shariati, N. H., & Zahedi, E. (2005) · International Conference on Computers, Communications, and Signal Processing with Special Track on Biomedical Engineering (CCSP) · doi:10.1109/ccsp.2005.4977182 · Cited by 30
Breathing rate estimation from a non-contact biosensor using an adaptive IIR notch filter
Ballal, T., Shouldice, R. B., Heneghan, C., & Zhu, A. (2012) · IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS) · doi:10.1109/biowireless.2012.6172727 · Cited by 21
Sardy, S. (2001) · Medical Entomology and Zoology · Cited by 20
Spot: An accurate and efficient multi-entity device-free WLAN localization systemPreprint
Sabek, I., & Youssef, M. A. (2012) · arXiv (Cornell University) · doi:10.48550/arxiv.1207.4265 · Cited by 9
Self-citation
Cited by
WiFi Sensing with Channel State Information: A Survey
Ma, Y., Zhou, G., & Wang, S. (2020) · ACM Computing Surveys · doi:10.1145/3310194 · Cited by 869
Wang, H., Zhang, D., Ma, J., Wang, Y., Wang, Y., Wu, D., Gu, T., & Xie, B. (2016) · Proceedings of the 2016 ACM International Joint Conference on Pervasive and Ubiquitous Computing · doi:10.1145/2971648.2971744 · Cited by 501
A Survey of Healthcare Internet of Things (HIoT): A Clinical Perspective
Habibzadeh, H., Dinesh, K., Rajabi Shishvan, O., Boggio-Dandry, A., Sharma, G., & Soyata, T. (2020) · IEEE Internet of Things Journal · doi:10.1109/jiot.2019.2946359 · Cited by 417
Wireless Sensing for Human Activity: A Survey
Liu, J., Liu, H., Chen, Y., Wang, Y., & Wang, C. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2019.2934489 · Cited by 414
“Additionally, UbiBreath [48] can achieve accurate estimation of user’s breathing rate with the error less than 1 breaths per minute (bpm) and also detect apnea with more than 96% accuracy.”
BackgroundInfluentialPhaseBeat: Exploiting CSI Phase Data for Vital Sign Monitoring with Commodity WiFi Devices
Wang, X., Yang, C., & Mao, S. (2017) · 2017 IEEE 37th International Conference on Distributed Computing Systems (ICDCS) · doi:10.1109/icdcs.2017.206 · Cited by 356
Metadata
- Authors
- Abdelnasser, H., Harras, K. A., & Youssef, M.
- Venue
- Proceedings of the 16th ACM International Symposium on Mobile Ad Hoc Networking and Computing
- Publisher
- ACM
- Published
- 2015-06-22
- Pages
- 277-286
- OpenAlex
- W2085522395
- Cited by
- 267
- References
- 42
- FWCI
- 41.42
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.