Digital Microfluidics
The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Digital microfluidics (DMF) is an emerging liquid-handling technology that enables individual control over droplets on an open array of electrodes. These picoliter- to microliter-sized droplets, each serving as an isolated vessel for chemical processes, can be made to move, merge, split, and dispense from reservoirs. Because of its unique advantages, including simple instrumentation, flexible device geometry, and easy coupling with other technologies, DMF is being applied to a wide range of fields. In this review, we summarize the state of the art of DMF technology from the perspective of analytical chemistry in sections describing the theory of droplet actuation, device fabrication and integration, and applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Electrowetting-based actuation of liquid droplets for microfluidic applications
Pollack, M. G., Fair, R. B., & Shenderov, A. D. (2000) · Applied Physics Letters · doi:10.1063/1.1308534 · Cited by 1,481
Srinivasan, V., Pamula, V. K., & Fair, R. B. (2004) · Lab on a Chip · doi:10.1039/b403341h · Cited by 1,066
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Microdroplets: A sea of applications?
Huebner, A., Sharma, S., Srisa-Art, M., Hollfelder, F., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b806405a · Cited by 619
Development of a digital microfluidic platform for point of care testing
Sista, R., Hua, Z., Thwar, P., Sudarsan, A., Srinivasan, V., Eckhardt, A., Pollack, M., & Pamula, V. (2008) · Lab on a Chip · doi:10.1039/b814922d · Cited by 550
Reversible Electrowetting and Trapping of Charge: Model and Experiments
Verheijen, H. J. J., & Prins, M. W. J. (1999) · Langmuir · doi:10.1021/la990548n · Cited by 509
Electrowetting: a recent outbreak
Quilliet, C., & Berge, B. (2001) · Current Opinion in Colloid & Interface Science · doi:10.1016/s1359-0294(00)00085-6 · Cited by 443
The Digital Revolution: A New Paradigm for Microfluidics
Abdelgawad, M., & Wheeler, A. R. (2009) · Advanced Materials · doi:10.1002/adma.200802244 · Cited by 382
Self-citationLimiting phenomena for the spreading of water on polymer films by electrowetting
Vallet, M., Vallade, M., & Berge, B. (1999) · The European Physical Journal B · doi:10.1007/s100510051186 · Cited by 362
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Molecular Digital Data Storage Using DNA
Ceze, L., Nivala, J., & Strauss, K. (2019) · Nature Reviews Genetics · doi:10.1038/s41576-019-0125-3 · Cited by 551
A review of digital microfluidics as portable platforms for lab-on a-chip applications
Samiei, E., Tabrizian, M., & Hoorfar, M. (2016) · Lab on a Chip · doi:10.1039/c6lc00387g · Cited by 471
Microfluidic Devices for Drug Delivery Systems and Drug Screening
Damiati, S., Kompella, U. B., Damiati, S. A., & Kodzius, R. (2018) · Genes · doi:10.3390/genes9020103 · Cited by 383
Ghosh, A., Ganguly, R., Schutzius, T. M., & Megaridis, C. M. (2014) · Lab Chip · doi:10.1039/c3lc51406d · Cited by 379
Hang, Y., Boryczka, J., & Wu, N. (2022) · Chemical Society Reviews · doi:10.1039/c9cs00621d · Cited by 377
Shembekar, N., Chaipan, C., Utharala, R., & Merten, C. A. (2016) · Lab on a Chip · doi:10.1039/c6lc00249h · Cited by 372
Active droplet sorting in microfluidics: a review
Xi, H.-D., Zheng, H., Guo, W., Gañán-Calvo, A. M., Ai, Y., Tsao, C.-W., Zhou, J., Li, W., Huang, Y., Nguyen, N.-T., et al. (2017) · Lab on a Chip · doi:10.1039/c6lc01435f · Cited by 369
Magnetic digital microfluidics – a review
Zhang, Y., & Nguyen, N.-T. (2017) · Lab on a Chip · doi:10.1039/c7lc00025a · Cited by 364
Recent Advances in Droplet Microfluidics
Ding, Y., Howes, P. D., & deMello, A. J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05047 · Cited by 357
Electrochemistry, biosensors and microfluidics: a convergence of fields
Rackus, D. G., Shamsi, M. H., & Wheeler, A. R. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00369a · Cited by 354
Self-citationAn outlook on microfluidics: the promise and the challenge
Battat, S., Weitz, D. A., & Whitesides, G. M. (2022) · Lab on a Chip · doi:10.1039/d1lc00731a · Cited by 333
Pattanayak, P., Singh, S. K., Gulati, M., Vishwas, S., Kapoor, B., Chellappan, D. K., Anand, K., Gupta, G., Jha, N. K., Gupta, P. K., et al. (2021) · Microfluidics and Nanofluidics · doi:10.1007/s10404-021-02502-2 · Cited by 330
Digital Assays Part I: Partitioning Statistics and Digital PCR
Basu, A. S. (2017) · SLAS Technology · doi:10.1177/2472630317705680 · Cited by 300
Controlled droplet microfluidic systems for multistep chemical and biological assays
Kaminski, T. S., & Garstecki, P. (2017) · Chemical Society Reviews · doi:10.1039/c5cs00717h · Cited by 299
Dalili, A., Samiei, E., & Hoorfar, M. (2019) · The Analyst · doi:10.1039/c8an01061g · Cited by 280
Moshksayan, K., Kashaninejad, N., Warkiani, M. E., Lock, J. G., Moghadas, H., Firoozabadi, B., Saidi, M. S., & Nguyen, N.-T. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.223 · Cited by 267
Trends in miniaturized biosensors for point-of-care testing
Liu, D., Wang, J., Wu, L., Huang, Y., Zhang, Y., Zhu, M., Wang, Y., Zhu, Z., & Yang, C. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115701 · Cited by 255
MicroRNA Biomarkers for Infectious Diseases: From Basic Research to Biosensing
Tribolet, L., Kerr, E., Cowled, C., Bean, A. G. D., Stewart, C. R., Dearnley, M., & Farr, R. J. (2020) · Frontiers in Microbiology · doi:10.3389/fmicb.2020.01197 · Cited by 222
Digital acoustofluidics enables contactless and programmable liquid handling
Zhang, S. P., Lata, J., Chen, C., Mai, J., Guo, F., Tian, Z., Ren, L., Mao, Z., Huang, P.-H., Li, P., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-05297-z · Cited by 207
Microfluidic hydrodynamic focusing for synthesis of nanomaterials
Lu, M., Ozcelik, A., Grigsby, C. L., Zhao, Y., Guo, F., Leong, K. W., & Huang, T. J. (2016) · Nano Today · doi:10.1016/j.nantod.2016.10.006 · Cited by 200
Capillarics: pre-programmed, self-powered microfluidic circuits built from capillary elements
Safavieh, R., & Juncker, D. (2013) · Lab on a Chip · doi:10.1039/c3lc50691f · Cited by 190
Soler, M., Estevez, M. C., Cardenosa-Rubio, M., Astua, A., & Lechuga, L. M. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01180 · Cited by 189
A digital microfluidic system for serological immunoassays in remote settings
Ng, A. H. C., Fobel, R., Fobel, C., Lamanna, J., Rackus, D. G., Summers, A., Dixon, C., Dryden, M. D. M., Lam, C., Ho, M., et al. (2018) · Science Translational Medicine · doi:10.1126/scitranslmed.aar6076 · Cited by 172
Self-citationPayne, E. M., Holland-Moritz, D. A., Sun, S., & Kennedy, R. T. (2020) · Lab on a Chip · doi:10.1039/d0lc00347f · Cited by 169
The Potential Impact of Droplet Microfluidics in Biology
Schneider, T., Kreutz, J., & Chiu, D. T. (2013) · Analytical Chemistry · doi:10.1021/ac400257c · Cited by 166
High Density DNA Data Storage Library via Dehydration with Digital Microfluidic Retrieval
Newman, S., Stephenson, A. P., Willsey, M., Nguyen, B. H., Takahashi, C. N., Strauss, K., & Ceze, L. (2019) · Nature Communications · doi:10.1038/s41467-019-09517-y · Cited by 144
Digital microfluidics for spheroid-based invasion assays
Bender, B. F., Aijian, A. P., & Garrell, R. L. (2016) · Lab on a Chip · doi:10.1039/c5lc01569c · Cited by 49
DNA Structural Barcode Copying and Random Access
Bošković, F., Ohmann, A., Keyser, U. F., & Chen, K. (2021) · Small Structures · doi:10.1002/sstr.202000144 · Cited by 24
Metadata
- Authors
- Choi, K., Ng, A. H. C., Fobel, R., & Wheeler, A. R.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2012-07-19
- Volume
- 5
- Issue
- 1
- Pages
- 413-440
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W4239130850
- Cited by
- 817
- References
- 65
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.