Digital Microfluidics
The DOI matches its Crossref record; 65 of the 65 references it cites were found in a registry or an index.
Abstract
Digital microfluidics (DMF) is an emerging liquid-handling technology that enables individual control over droplets on an open array of electrodes. These picoliter- to microliter-sized droplets, each serving as an isolated vessel for chemical processes, can be made to move, merge, split, and dispense from reservoirs. Because of its unique advantages, including simple instrumentation, flexible device geometry, and easy coupling with other technologies, DMF is being applied to a wide range of fields. In this review, we summarize the state of the art of DMF technology from the perspective of analytical chemistry in sections describing the theory of droplet actuation, device fabrication and integration, and applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Electrowetting-based actuation of liquid droplets for microfluidic applications
Pollack, M. G., Fair, R. B., & Shenderov, A. D. (2000) · Applied Physics Letters · doi:10.1063/1.1308534 · Cited by 1,481
Srinivasan, V., Pamula, V. K., & Fair, R. B. (2004) · Lab on a Chip · doi:10.1039/b403341h · Cited by 1,066
Microdroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Microdroplets: A sea of applications?
Huebner, A., Sharma, S., Srisa-Art, M., Hollfelder, F., Edel, J. B., & deMello, A. J. (2008) · Lab on a Chip · doi:10.1039/b806405a · Cited by 619
Development of a digital microfluidic platform for point of care testing
Sista, R., Hua, Z., Thwar, P., Sudarsan, A., Srinivasan, V., Eckhardt, A., Pollack, M., & Pamula, V. (2008) · Lab on a Chip · doi:10.1039/b814922d · Cited by 550
Reversible Electrowetting and Trapping of Charge: Model and Experiments
Verheijen, H. J. J., & Prins, M. W. J. (1999) · Langmuir · doi:10.1021/la990548n · Cited by 509
Electrowetting: a recent outbreak
Quilliet, C., & Berge, B. (2001) · Current Opinion in Colloid & Interface Science · doi:10.1016/s1359-0294(00)00085-6 · Cited by 443
The Digital Revolution: A New Paradigm for Microfluidics
Abdelgawad, M., & Wheeler, A. R. (2009) · Advanced Materials · doi:10.1002/adma.200802244 · Cited by 382
Self-citationLimiting phenomena for the spreading of water on polymer films by electrowetting
Vallet, M., Vallade, M., & Berge, B. (1999) · The European Physical Journal B · doi:10.1007/s100510051186 · Cited by 362
Planar chip device for PCR and hybridization with surface acoustic wave pump
Guttenberg, Z., Müller, H., Habermüller, H., Geisbauer, A., Pipper, J., Felbel, J., Kielpinski, M., Scriba, J., & Wixforth, A. (2005) · Lab Chip · doi:10.1039/b412712a · Cited by 349
Digital microfluidics for cell-based assays
Barbulovic-Nad, I., Yang, H., Park, P. S., & Wheeler, A. R. (2008) · Lab on a Chip · doi:10.1039/b717759c · Cited by 337
Self-citationChemical and Biological Applications of Digital-Microfluidic Devices
Fair, R. B., Khlystov, A., Tailor, T. D., Ivanov, V., Evans, R. D., Srinivasan, V., Pamula, V. K., Pollack, M. G., Griffin, P. B., & Zhou, J. (2007) · IEEE Design & Test of Computers · doi:10.1109/mdt.2007.8 · Cited by 325
Integrated polymerase chain reaction chips utilizing digital microfluidics
Chang, Y.-H., Lee, G.-B., Huang, F.-C., Chen, Y.-Y., & Lin, J.-L. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-8171-y · Cited by 324
Putting Electrowetting to Work
Wheeler, A. R. (2008) · Science · doi:10.1126/science.1165719 · Cited by 315
Self-citationMoon, H., Wheeler, A. R., Garrell, R. L., Loo, J. A., & Kim, C.-J. ?. (2006) · Lab on a Chip · doi:10.1039/b601954d · Cited by 296
Self-citationHeterogeneous immunoassays using magnetic beads on a digital microfluidic platform
Sista, R. S., Eckhardt, A. E., Srinivasan, V., Pollack, M. G., Palanki, S., & Pamula, V. K. (2008) · Lab on a Chip · doi:10.1039/b807855f · Cited by 294
Wheeler, A. R., Moon, H., Kim, C.-J. “., Loo, J. A., & Garrell, R. L. (2004) · Analytical Chemistry · doi:10.1021/ac0498112 · Cited by 262
Self-citationGong, J., & Kim, C.-J. “. (2008) · Lab on a Chip · doi:10.1039/b717417a · Cited by 258
Digital Microfluidics with In-Line Sample Purification for Proteomics Analyses with MALDI-MS
Wheeler, A. R., Moon, H., Bird, C. A., Ogorzalek Loo, R. R., Kim, C.-J. “. J. ”., Loo, J. A., & Garrell, R. L. (2005) · Analytical Chemistry · doi:10.1021/ac048754+ · Cited by 255
Self-citationA microfluidic platform for complete mammalian cell culture
Barbulovic-Nad, I., Au, S. H., & Wheeler, A. R. (2010) · Lab on a Chip · doi:10.1039/c002147d · Cited by 249
Self-citationMultiplexed Real-Time Polymerase Chain Reaction on a Digital Microfluidic Platform
Hua, Z., Rouse, J. L., Eckhardt, A. E., Srinivasan, V., Pamula, V. K., Schell, W. A., Benton, J. L., Mitchell, T. G., & Pollack, M. G. (2010) · Analytical Chemistry · doi:10.1021/ac902510u · Cited by 248
Darhuber, A. A., Valentino, J. P., Troian, S. M., & Wagner, S. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.820267 · Cited by 240
Pluronic Additives: A Solution to Sticky Problems in Digital Microfluidics
Luk, V. N., Mo, G. C., & Wheeler, A. R. (2008) · Langmuir · doi:10.1021/la7039509 · Cited by 227
Self-citationAnisotropic particle synthesis in dielectrophoretically controlled microdroplet reactors
Millman, J. R., Bhatt, K. H., Prevo, B. G., & Velev, O. D. (2005) · Nature Materials · doi:10.1038/nmat1270 · Cited by 227
Integration and detection of biochemical assays in digital microfluidic LOC devices
Malic, L., Brassard, D., Veres, T., & Tabrizian, M. (2010) · Lab Chip · doi:10.1039/b917668c · Cited by 207
Koc, Y., de Mello, A. J., McHale, G., Newton, M. I., Roach, P., & Shirtcliffe, N. J. (2008) · Lab on a Chip · doi:10.1039/b716509a · Cited by 201
Abdelgawad, M., Freire, S. L. S., Yang, H., & Wheeler, A. R. (2008) · Lab on a Chip · doi:10.1039/b801516c · Cited by 188
Self-citationMicro-chemical synthesis of molecular probes on an electronic microfluidic device
Keng, P. Y., Chen, S., Ding, H., Sadeghi, S., Shah, G. J., Dooraghi, A., Phelps, M. E., Satyamurthy, N., Chatziioannou, A. F., Kim, C.-J. “., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1117566109 · Cited by 180
A Digital Microfluidic Approach to Homogeneous Enzyme Assays
Miller, E. M., & Wheeler, A. R. (2008) · Analytical Chemistry · doi:10.1021/ac702269d · Cited by 167
Self-citationFan, S.-K., Huang, P.-W., Wang, T.-T., & Peng, Y.-H. (2008) · Lab on a Chip · doi:10.1039/b803204a · Cited by 167
Applications of electrowetting-based digital microfluidics in clinical diagnostics
Pollack, M. G., Pamula, V. K., Srinivasan, V., & Eckhardt, A. E. (2011) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.11.22 · Cited by 157
Integrated Optical Sensor in a Digital Microfluidic Platform
Luan, L., Evans, R. D., Jokerst, N. M., & Fair, R. B. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.918717 · Cited by 152
Single-sided continuous optoelectrowetting (SCOEW) for droplet manipulation with light patterns
Park, S.-Y., Teitell, M. A., & Chiou, E. P. Y. (2010) · Lab on a Chip · doi:10.1039/c001324b · Cited by 150
Malic, L., Veres, T., & Tabrizian, M. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.11.031 · Cited by 144
Microfluidics Using Spatially Defined Arrays of Droplets in One, Two, and Three Dimensions
Pompano, R. R., Liu, W., Du, W., & Ismagilov, R. F. (2011) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.012809.102303 · Cited by 144
A Digital Microfluidic Approach to Proteomic Sample Processing
Luk, V. N., & Wheeler, A. R. (2009) · Analytical Chemistry · doi:10.1021/ac900522a · Cited by 142
Self-citationA digital microfluidic method for dried blood spot analysis
Jebrail, M. J., Yang, H., Mudrik, J. M., Lafrenière, N. M., McRoberts, C., Al-Dirbashi, O. Y., Fisher, L., Chakraborty, P. K., & Wheeler, A. R. (2011) · Lab on a Chip · doi:10.1039/c1lc20524b · Cited by 139
Self-citationIntegrated microbioreactor for culture and analysis of bacteria, algae and yeast
Au, S. H., Shih, S. C. C., & Wheeler, A. R. (2010) · Biomedical Microdevices · doi:10.1007/s10544-010-9469-3 · Cited by 133
Self-citationElectromechanical model for actuating liquids in a two-plate droplet microfluidic device
Chatterjee, D., Shepherd, H., & Garrell, R. L. (2009) · Lab on a Chip · doi:10.1039/b901375j · Cited by 125
Abdelgawad, M. O., Watson, M. W. L., & Wheeler, A. R. (2009) · Lab on a Chip · doi:10.1039/b820682a · Cited by 122
Self-citationSista, R. S., Eckhardt, A. E., Wang, T., Graham, C., Rouse, J. L., Norton, S. M., Srinivasan, V., Pollack, M. G., Tolun, A. A., Bali, D. S., et al. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2011.163139 · Cited by 117
A New Angle on Pluronic Additives: Advancing Droplets and Understanding in Digital Microfluidics
Au, S. H., Kumar, P., & Wheeler, A. R. (2011) · Langmuir · doi:10.1021/la201185c · Cited by 115
Self-citationSynchronized Synthesis of Peptide‐Based Macrocycles by Digital Microfluidics
Jebrail, M. J., Ng, A. H. C., Rai, V., Hili, R., Yudin, A. K., & Wheeler, A. R. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201001604 · Cited by 111
Self-citationUsing EWOD (electrowetting-on-dielectric) actuation in a micro conveyor system
Moon, I., & Kim, J. (2006) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2005.12.016 · Cited by 107
Microparticle sampling by electrowetting-actuated droplet sweeping
Zhao, Y., & Cho, S. K. (2005) · Lab on a Chip · doi:10.1039/b511645g · Cited by 107
A digital microfluidic platform for primary cell culture and analysis
Srigunapalan, S., Eydelnant, I. A., Simmons, C. A., & Wheeler, A. R. (2011) · Lab on a Chip · doi:10.1039/c1lc20844f · Cited by 105
Self-citationA digital microfluidic method for multiplexed cell-based apoptosis assays
Bogojevic, D., Chamberlain, M. D., Barbulovic-Nad, I., & Wheeler, A. R. (2012) · Lab Chip · doi:10.1039/c2lc20893h · Cited by 103
Self-citationVirtual microwells for digital microfluidic reagent dispensing and cell culture
Eydelnant, I. A., Uddayasankar, U., Li, B. ‘., Liao, M. W., & Wheeler, A. R. (2011) · Lab on a Chip · doi:10.1039/c2lc21004e · Cited by 98
Self-citationDroplet-Scale Estrogen Assays in Breast Tissue, Blood, and Serum
Mousa, N. A., Jebrail, M. J., Yang, H., Abdelgawad, M. O., Metalnikov, P. S., Chen, J., Wheeler, A. R., & Casper, R. F. (2009) · Science Translational Medicine · doi:10.1126/scitranslmed.3000105 · Cited by 98
Self-citationWijethunga, P. A. L., Nanayakkara, Y. S., Kunchala, P., Armstrong, D. W., & Moon, H. (2011) · Analytical Chemistry · doi:10.1021/ac102716s · Cited by 96
Nelson, W. C., Peng, I. X., Lee, G. A., Loo, J. A., Garrell, R. L., & Kim, C. (2010) · Analytical Chemistry · doi:10.1021/ac101833b · Cited by 91
A World-to-Chip Interface for Digital Microfluidics
Yang, H. C., Luk, V. N., Abdelgawad, M. O., Barbulovic-Nad, I., & Wheeler, A. R. (2008) · Analytical Chemistry · doi:10.1021/ac802154h · Cited by 83
Self-citationIntegration of Protein Processing Steps on a Droplet Microfluidics Platform for MALDI-MS Analysis
Chatterjee, D., Ytterberg, A. J., Son, S. U., Loo, J. A., & Garrell, R. L. (2010) · Analytical Chemistry · doi:10.1021/ac9029373 · Cited by 77
Nichols, K. P., & Gardeniers, H. J. G. E. (2007) · Analytical Chemistry · doi:10.1021/ac071235x · Cited by 76
DNA ligation of ultramicro volume using an EWOD microfluidic system with coplanar electrodes
Liu, Y.-J., Yao, D., Lin, H.-C., Chang, W.-Y., & Chang, H. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/4/045017 · Cited by 70
Picoliter DNA sequencing chemistry on an electrowetting‐based digital microfluidic platform
Welch, E. R. F., Lin, Y., Madison, A. C., & Fair, R. B. (2010) · Biotechnology Journal · doi:10.1002/biot.201000324 · Cited by 67
Adaptive Chip Cooling Using Electrowetting on Coplanar Control Electrodes
Cheng, J., & Chen, C.-L. (2010) · Nanoscale and Microscale Thermophysical Engineering · doi:10.1080/15567261003601771 · Cited by 66
Magnetic movement of biological fluid droplets
García, A. A., Egatz-Gómez, A., Lindsay, S., Domínguez-García, P., Melle, S., Márquez, M., Rubio, M. A., Picraux, S. T., Yang, D., Aella, P., et al. (2006) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2006.10.1149 · Cited by 65
Martin, J. G., Gupta, M., Xu, Y.-M., Akella, S., Liu, J., Dordick, J., & Linhardt, R. (2009) · Journal of the American Chemical Society · doi:10.1021/ja903038d · Cited by 65
Encapsulated droplets with metered and removable oil shells by electrowetting and dielectrophoresis
Fan, S., Hsu, Y.-W., & Chen, C.-H. (2011) · Lab on a Chip · doi:10.1039/c1lc20142e · Cited by 57
Malic, L., Veres, T., & Tabrizian, M. (2008) · Lab on a Chip · doi:10.1039/b814697g · Cited by 55
Hydrogel discs for digital microfluidics
Fiddes, L. K., Luk, V. N., Au, S. H., Ng, A. H. C., Luk, V., Kumacheva, E., & Wheeler, A. R. (2012) · Biomicrofluidics · doi:10.1063/1.3687381 · Cited by 54
Self-citationDigitized Heat Transfer Using Electrowetting on Dielectric
Mohseni, K., & Baird, E. (2007) · Nanoscale and Microscale Thermophysical Engineering · doi:10.1080/15567260701337555 · Cited by 54
Park, S., Wijethunga, P. A. L., Moon, H., & Han, B. (2011) · Lab on a Chip · doi:10.1039/c1lc20111e · Cited by 49
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Recent Developments in Paper-Based Microfluidic Devices
Cate, D. M., Adkins, J. A., Mettakoonpitak, J., & Henry, C. S. (2015) · Analytical Chemistry · doi:10.1021/ac503968p · Cited by 1,236
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Molecular Digital Data Storage Using DNA
Ceze, L., Nivala, J., & Strauss, K. (2019) · Nature Reviews Genetics · doi:10.1038/s41576-019-0125-3 · Cited by 551
A review of digital microfluidics as portable platforms for lab-on a-chip applications
Samiei, E., Tabrizian, M., & Hoorfar, M. (2016) · Lab on a Chip · doi:10.1039/c6lc00387g · Cited by 471
Metadata
- Authors
- Choi, K., Ng, A. H. C., Fobel, R., & Wheeler, A. R.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2012-07-19
- Volume
- 5
- Issue
- 1
- Pages
- 413-440
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W4239130850
- Cited by
- 817
- References
- 65
- FWCI
- 3.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.