Positron Emission Tomography: Current Challenges and Opportunities for Technological Advances in Clinical and Preclinical Imaging Systems
Open accessThe DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Abstract
Positron emission tomography (PET) imaging is based on detecting two time-coincident high-energy photons from the emission of a positron-emitting radioisotope. The physics of the emission, and the detection of the coincident photons, give PET imaging unique capabilities for both very high sensitivity and accurate estimation of the in vivo concentration of the radiotracer. PET imaging has been widely adopted as an important clinical modality for oncological, cardiovascular, and neurological applications. PET imaging has also become an important tool in preclinical studies, particularly for investigating murine models of disease and other small-animal models. However, there are several challenges to using PET imaging systems. These include the fundamental trade-offs between resolution and noise, the quantitative accuracy of the measurements, and integration with X-ray computed tomography and magnetic resonance imaging. In this article, we review how researchers and industry are addressing these challenges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Self-citationOllinger, J. M., & Fessler, J. A. (1997) · IEEE Signal Processing Magazine · doi:10.1109/79.560323 · Cited by 1,167
Performance Measurements of the Siemens mMR Integrated Whole-Body PET/MR Scanner
Delso, G., Fürst, S., Jakoby, B., Ladebeck, R., Ganter, C., Nekolla, S. G., Schwaiger, M., & Ziegler, S. I. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092726 · Cited by 874
Principles of magnetic resonance imaging : a signal processing perspective
Liang, Z.-P., & Lauterbur, P. C. (2000) · Cited by 767
Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R. A., Chefd'hotel, C., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054726 · Cited by 712
Kinahan, P. E., & Fletcher, J. W. (2010) · Seminars in Ultrasound, CT and MRI · doi:10.1053/j.sult.2010.10.001 · Cited by 631 · cited 1×
“This may change as attention is increasingly paid to quantitative accuracy in PET imaging (58, 59).”
BackgroundSelf-citationX-ray-based attenuation correction for positron emission tomography/computed tomography scanners
Kinahan, P. E., Hasegawa, B. H., & Beyer, T. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127307 · Cited by 515
Self-citationDistance-driven projection and backprojection in three dimensions
Man, B. D., & Basu, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/11/024 · Cited by 459
(2012) · Elsevier eBooks · doi:10.1016/c2009-0-51635-2 · Cited by 459
Uptake in supraclavicular area fat ("USA-Fat"): description on 18F-FDG PET/CT.
Cohade, C., Osman, M., Pannu, H. K., & Wahl, R. L. (2003) · PubMed · Cited by 440
Iterative reconstruction techniques in emission computed tomography
Qi, J., & Leahy, R. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/r01 · Cited by 415
Principles of Magnetic Resonance Imaging
Liang, Z.-P., & Lauterbur, P. C. (1999) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470545652 · Cited by 412
Model-based scatter correction for fully 3D PET
Ollinger, J. M. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/012 · Cited by 393
Simultaneous PET and MR imaging
Shao, Y., Cherry, S. R., Farahani, K., Meadors, K., Siegel, S., Silverman, R. W., & Marsden, P. K. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/10/010 · Cited by 374
Catana, C., van der Kouwe, A., Benner, T., Michel, C. J., Hamm, M., Fenchel, M., Fischl, B., Rosen, B., Schmand, M., & Sorensen, A. G. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069112 · Cited by 359
Dual-Energy (Spectral) CT: Applications in Abdominal Imaging
Silva, A. C., Morse, B. G., Hara, A. K., Paden, R. G., Hongo, N., & Pavlicek, W. (2011) · RadioGraphics · doi:10.1148/rg.314105159 · Cited by 351
Performance evaluation of the GE healthcare eXplore VISTA dual-ring small-animal PET scanner.
Wang, Y., Seidel, J., Tsui, B. M. W., Vaquero, J. J., & Pomper, M. G. (2006) · PubMed · Cited by 329
Self-citationRespiratory Motion in Positron Emission Tomography/Computed Tomography: A Review
Nehmeh, S. A., & Erdi, Y. E. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.01.002 · Cited by 317
Sgouros, G., Kolbert, K. S., Sheikh, A., Pentlow, K. S., Mun, E. F., Barth, A., Robbins, R. J., & Larson, S. M. (2004) · PubMed · Cited by 308
Bao, Q., Newport, D., Chen, M., Stout, D. B., & Chatziioannou, A. F. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.056374 · Cited by 306
State of the art and challenges of time-of-flight PET
Conti, M. (2009) · Physica Medica · doi:10.1016/j.ejmp.2008.10.001 · Cited by 274
El Fakhri, G., Kardan, A., Sitek, A., Dorbala, S., Abi-Hatem, N., Lahoud, Y., Fischman, A., Coughlan, M., Yasuda, T., & Di Carli, M. F. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.104.007831 · Cited by 266
From PET detectors to PET scanners
Humm, J. L., Rosenfeld, A., & Del Guerra, A. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-003-1266-2 · Cited by 245
Application of Silicon Photomultipliers to Positron Emission Tomography
Roncali, E., & Cherry, S. R. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0266-9 · Cited by 239
Multimodality Imaging: Beyond PET/CT and SPECT/CT
Cherry, S. R. (2009) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2009.03.001 · Cited by 238
The impact of respiratory motion on tumor quantification and delineation in static PET/CT imaging
Liu, C., Pierce II, L. A., Alessio, A. M., & Kinahan, P. E. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/24/007 · Cited by 232
Self-citationRecent advances and future advances in time-of-flight PET
Moses, W. W. (2007) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/j.nima.2007.06.038 · Cited by 205
Competitive advantage of PET/MRI
Jadvar, H., & Colletti, P. M. (2014) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.05.028 · Cited by 195
Dual- and multi-energy CT: approach to functional imaging
Fornaro, J., Leschka, S., Hibbeln, D., Butler, A., Anderson, N., Pache, G., Scheffel, H., Wildermuth, S., Alkadhi, H., & Stolzmann, P. (2011) · Insights into Imaging · doi:10.1007/s13244-010-0057-0 · Cited by 184
Mawlawi, O. R., Podoloff, D. A., Kohlmyer, S. G., Williams, J. J., Stearns, C. W., Culp, R. F., & Macapinlac, H. A. (2004) · PubMed · Cited by 184
MRI-Based Nonrigid Motion Correction in Simultaneous PET/MRI
Chun, S. Y., Reese, T. G., Ouyang, J., Guérin, B., Catana, C., Zhu, X., Alpert, N. M., & Fakhri, G. E. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.092353 · Cited by 180
Cardiac positron emission tomography imaging
Machac, J. (2005) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2004.09.002 · Cited by 176
Imaging preclinical tumour models: improving translational power
de Jong, M., Essers, J., & van Weerden, W. M. (2014) · Nature Reviews Cancer · doi:10.1038/nrc3751 · Cited by 176
Optimized 124I PET Dosimetry Protocol for Radioiodine Therapy of Differentiated Thyroid Cancer
Jentzen, W., Freudenberg, L., Eising, E. G., Sonnenschein, W., Knust, J., & Bockisch, A. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.047159 · Cited by 166
Extension of Single Scatter Simulation to Scatter Correction of Time-of-Flight PET
Watson, C. (2007) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2007.901227 · Cited by 164
Lewellen, T. K. (1998) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(98)80031-7 · Cited by 160
MR-Based PET Attenuation Correction for PET/MR Imaging
Bezrukov, I., Mantlik, F., Schmidt, H., Schölkopf, B., & Pichler, B. J. (2012) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2012.08.002 · Cited by 158
Quick, H. H. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24523 · Cited by 151
PET Approaches for Diagnosis of Dementia
Ishii, K. (2014) · American Journal of Neuroradiology · doi:10.3174/ajnr.a3695 · Cited by 148
Attenuation correction for small animal PET tomographs
Chow, P. L., Rannou, F. R., & Chatziioannou, A. F. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/8/014 · Cited by 145
PET and MR Imaging: The Odd Couple or a Match Made in Heaven?
Catana, C., Guimarães, A. R., & Rosen, B. R. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.112771 · Cited by 140
Technology Insight: advances in molecular imaging and an appraisal of PET/CT scanning
Weber, W., Grosu, A., & Czernin, J. G. (2008) · Nature Clinical Practice Oncology · doi:10.1038/ncponc1041 · Cited by 131
Poon, J. K., Dahlbom, M. L., Moses, W. W., Balakrishnan, K., Wang, W., Cherry, S. R., & Badawi, R. D. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/13/4077 · Cited by 129
Brasse, D., Kinahan, P. E., Lartizien, C., Comtat, C., Casey, M., & Michel, C. J. (2005) · PubMed · Cited by 122
Self-citationQuantitative assessment of dynamic PET imaging data in cancer imaging
Muzi, M., O’Sullivan, F., Mankoff, D. A., Doot, R. K., Pierce, L. A., Kurland, B. F., Linden, H. M., & Kinahan, P. E. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.05.008 · Cited by 121
Self-citationRecent Developments in PET Instrumentation
Peng, H., & Levin, C. S. (2010) · Current Pharmaceutical Biotechnology · doi:10.2174/138920110792246555 · Cited by 112
Seifert, S., van der Lei, G., van Dam, H. T., & Schaart, D. R. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/9/3061 · Cited by 106
Qualitative and Quantitative Comparison of PET/CT and PET/MR Imaging in Clinical Practice
Al-Nabhani, K. Z., Syed, R., Michopoulou, S., Alkalbani, J., Afaq, A., Panagiotidis, E., O’Meara, C., Groves, A., Ell, P., & Bomanji, J. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.123547 · Cited by 101
Assessment of acquisition protocols for routine imaging of Y-90 using PET/CT
Carlier, T., Eugène, T., Bodet‐Milin, C., Garin, É., Ansquer, C., Rousseau, C., Ferrer, L., Barbet, J., Schoenahl, F., & Kraeber‐Bodéré, F. (2013) · EJNMMI Research · doi:10.1186/2191-219x-3-11 · Cited by 84
Performance Evaluation of a New Dedicated Breast PET Scanner Using NEMA NU4-2008 Standards
Miyake, K. K., Matsumoto, K., Inoue, M., Nakamoto, Y., Kanao, S., Oishi, T., Kawase, S., Kitamura, K., Yamakawa, Y., Akazawa, A., et al. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.131565 · Cited by 82
Dual-isotope PET using positron-gamma emitters
Andreyev, A., & Celler, A. M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/14/020 · Cited by 81
Kinahan, P. E., Alessio, A. M., & Fessler, J. A. (2006) · Technology in Cancer Research & Treatment · doi:10.1177/153303460600500403 · Cited by 69
Self-citationDaube-Witherspoon, M. E., Surti, S., Perkins, A. E., & Karp, J. S. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.127035 · Cited by 62
Accuracy of CT-based attenuation correction in PET/CT bone imaging
Abella, M., Alessio, A. M., Mankoff, D. A., MacDonald, L. R., Vaquero, J. J., Desco, M., & Kinahan, P. E. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/9/2477 · Cited by 60
Self-citationvan Eijk, C. W. E. (2008) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncn043 · Cited by 60
A new dual threshold time-over-threshold circuit for fast timing in PET
Grant, A. M., & Levin, C. S. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/13/3421 · Cited by 57
Systematic Evaluation of Phantom Fluids for Simultaneous PET/MR Hybrid Imaging
Ziegler, S., Braun, H., Ritt, P., Hocke, C., Kuwert, T., & Quick, H. H. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.116376 · Cited by 50
Parameterization of a model-based 3-D PET scatter correction
Wollenweber, S. D. (2002) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2002.1039554 · Cited by 47
Seo, Y., Gustafson, W. C., Dannoon, S. F., Nekritz, E. A., Lee, C.-L., Murphy, S. T., VanBrocklin, H. F., Hernandez‐Pampaloni, M., Haas-Kogan, D. A., Weiss, W. A., et al. (2012) · Molecular Imaging and Biology · doi:10.1007/s11307-012-0552-4 · Cited by 45
Detection and treatment of subclinical tuberculosis
Robertson, B. D., Altmann, D. M., Barry, C. E., Bishai, B., Cole, S. T., Dick, T., Duncan, K., Dye, C., Ehrt, S., Esmail, H., et al. (2012) · Tuberculosis · doi:10.1016/j.tube.2012.06.004 · Cited by 41
Improving time resolution in time-of-flight PET
Conti, M. (2010) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2010.11.171 · Cited by 36
Analytic Image Reconstruction Methods
Kinahan, P. E., Defrise, M., & Clackdoyle, R. (2004) · Elsevier eBooks · doi:10.1016/b978-012744482-6.50023-5 · Cited by 35
Self-citationDOI Determination by Rise Time Discrimination in Single-Ended Readout for TOF PET Imaging
Wiener, R. I., Surti, S., & Karp, J. S. (2013) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2013.2243166 · Cited by 28
Direct 4D Parametric Imaging in Dynamic Myocardial Perfusion PET
Rahmim, A., Tang, J., & Mohy‐ud‐Din, H. (2014) · DOAJ (DOAJ: Directory of Open Access Journals) · Cited by 21
The role of molecular imaging in the evaluation of myocardial and peripheral angiogenesis
Stacy, M. R., Paeng, J. C., & Sinusas, A. J. (2015) · Annals of Nuclear Medicine · doi:10.1007/s12149-015-0961-y · Cited by 15
Bacharach, S. L. (2010) · doi:10.1002/9781444323894.ch1 · Cited by 6
Lung imaging in rodents using dual energy micro-CT
Badea, C. T., Guo, X., Clark, D. P., Johnston, S. M., Marshall, C., & Piantadosi, C. (2012) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.912155 · Cited by 5
Cited by
Characterization of PET/CT images using texture analysis: the past, the present… any future?
Hatt, M., Tixier, F., Pierce, L., Kinahan, P. E., Le Rest, C. C., & Visvikis, D. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3427-0 · Cited by 475
Self-citationTechnological advancements in cancer diagnostics: Improvements and limitations
Pulumati, A., Pulumati, A., Dwarakanath, B. S., Verma, A., & Papineni, R. V. L. (2023) · Cancer Reports · doi:10.1002/cnr2.1764 · Cited by 326
History and future technical innovation in positron emission tomography
Jones, T., & Townsend, D. (2017) · Journal of Medical Imaging · doi:10.1117/1.jmi.4.1.011013 · Cited by 303
Ferroptosis Detection: From Approaches to Applications
Zeng, F., Nijiati, S., Tang, L., Ye, J., Zhou, Z., & Chen, X. (2023) · Angewandte Chemie International Edition · doi:10.1002/anie.202300379 · Cited by 300
Torkamani, A., Andersen, K. G., Steinhubl, S. R., & Topol, E. J. (2017) · Cell · doi:10.1016/j.cell.2017.08.007 · Cited by 241
Metadata
- Authors
- Vaquero, J. J., & Kinahan, P.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2015-12-07
- Volume
- 17
- Issue
- 1
- Pages
- 385-414
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W1924463094
- Cited by
- 383
- References
- 71
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.