Lensless Imaging and Sensing
The DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.
Abstract
High-resolution optical microscopy has traditionally relied on high-magnification and high–numerical aperture objective lenses. In contrast, lensless microscopy can provide high-resolution images without the use of any focusing lenses, offering the advantages of a large field of view, high resolution, cost-effectiveness, portability, and depth-resolved three-dimensional (3D) imaging. Here we review various approaches to lensless imaging, as well as its applications in biosensing, diagnostics, and cytometry. These approaches include shadow imaging, fluorescence, holography, superresolution 3D imaging, iterative phase recovery, and color imaging. These approaches share a reliance on computational techniques, which are typically necessary to reconstruct meaningful images from the raw data captured by digital image sensors. When these approaches are combined with physical innovations in sample preparation and fabrication, lensless imaging can be used to image and sense cells, viruses, nanoparticles, and biomolecules. We conclude by discussing several ways in which lensless imaging and sensing might develop in the near future.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A note on two problems in connexion with graphs
Dijkstra, E. W. (1959) · Numerische Mathematik · doi:10.1007/bf01386390 · Cited by 29,065
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Extraordinary optical transmission through sub-wavelength hole arrays
Ebbesen, T. W., Lezec, H. J., Ghaemi, H. F., Thio, T., & Wolff, P. A. (1998) · Nature · doi:10.1038/35570 · Cited by 7,687
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596
GABOR, D. (1948) · Nature · doi:10.1038/161777a0 · Cited by 4,548
A practical algorithm for the determination of phase from image and diffraction plane pictures
Gerchberg, R. W. (1972) · Optik · Cited by 4,519
Performance of optical flow techniques
Barron, J. L., Fleet, D. J., & Beauchemin, S. S. (1994) · International Journal of Computer Vision · doi:10.1007/bf01420984 · Cited by 4,305
Bayesian-Based Iterative Method of Image Restoration*
Richardson, W. H. (1972) · Journal of the Optical Society of America · doi:10.1364/josa.62.000055 · Cited by 4,160
Goodman, J. W. (1985) · Cited by 4,004
An iterative technique for the rectification of observed distributions
Lucy, L. B. (1974) · The Astronomical Journal · doi:10.1086/111605 · Cited by 3,866
Dynamic Light Scattering: With Applications to Chemistry, Biology, and Physics
Berne, B. J., & Pecora, R. (1976) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,856
Filipe, V., Hawe, A., & Jiskoot, W. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0073-2 · Cited by 1,885
Deterministic phase retrieval: a Green’s function solution
Teague, M. R. (1983) · Journal of the Optical Society of America · doi:10.1364/josa.73.001434 · Cited by 1,419
A new algorithm in spectral analysis and band-limited extrapolation
Papoulis, A. (1975) · IEEE Transactions on Circuits and Systems · doi:10.1109/tcs.1975.1084118 · Cited by 1,063
Comparative advantages of mechanical biosensors
Arlett, J. L., Myers, E. B., & Roukes, M. L. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.44 · Cited by 966
Mobile Phone Based Clinical Microscopy for Global Health Applications
Breslauer, D. N., Maamari, R. N., Switz, N. A., Lam, W. A., & Fletcher, D. A. (2009) · PLoS ONE · doi:10.1371/journal.pone.0006320 · Cited by 694
Imaging without lenses: achievements and remaining challenges of wide-field on-chip microscopy
Greenbaum, A., Luo, W., Su, T.-W., Göröcs, Z., Xue, L., Isikman, S. O., Coskun, A. F., Mudanyali, O., & Ozcan, A. (2012) · Nature Methods · doi:10.1038/nmeth.2114 · Cited by 540
Self-citationMudanyali, O., Tseng, D., Oh, C., Isikman, S. O., Sencan, I., Bishara, W., Oztoprak, C., Seo, S., Khademhosseini, B., & Ozcan, A. (2010) · Lab on a Chip · doi:10.1039/c000453g · Cited by 488
Self-citationLensfree microscopy on a cellphone
Tseng, D., Mudanyali, O., Oztoprak, C., Isikman, S. O., Sencan, I., Yaglidere, O., & Ozcan, A. (2010) · Lab on a Chip · doi:10.1039/c003477k · Cited by 480
Self-citationElad, M., & Hel-Or, Y. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.935034 · Cited by 456
Fluorescent Imaging of Single Nanoparticles and Viruses on a Smart Phone
Wei, Q., Qi, H., Luo, W., Tseng, D., Ki, S. J., Wan, Z., Göröcs, Z., Bentolila, L. A., Wu, T.-T., Sun, R., et al. (2013) · ACS Nano · doi:10.1021/nn4037706 · Cited by 452
Self-citationLensfree on-chip microscopy over a wide field-of-view using pixel super-resolution
Bishara, W., Su, T.-W., Coskun, A. F., & Ozcan, A. (2010) · Optics Express · doi:10.1364/oe.18.011181 · Cited by 440
Self-citationIntegrated rapid-diagnostic-test reader platform on a cellphone
Mudanyali, O., Dimitrov, S., Sikora, U., Padmanabhan, S., Navruz, I., & Ozcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40235a · Cited by 426
Foldscope: Origami-Based Paper Microscope
Cybulski, J. S., Clements, J., & Prakash, M. (2014) · PLoS ONE · doi:10.1371/journal.pone.0098781 · Cited by 388
Mobile phones democratize and cultivate next-generation imaging, diagnostics and measurement tools
Ozcan, A. (2014) · Lab Chip · doi:10.1039/c4lc00010b · Cited by 364
Self-citationSmartphone based health accessory for colorimetric detection of biomarkers in sweat and saliva
Oncescu, V., O'Dell, D., & Erickson, D. (2013) · Lab on a Chip · doi:10.1039/c3lc50431j · Cited by 362
Berg, B., Cortazar, B., Tseng, D., Ozkan, H., Feng, S., Wei, Q., Chan, R. Y.-L., Burbano, J., Farooqui, Q., Lewinski, M., et al. (2015) · ACS Nano · doi:10.1021/acsnano.5b03203 · Cited by 362
Self-citationHandheld high-throughput plasmonic biosensor using computational on-chip imaging
Cetin, A. E., Coskun, A. F., Galarreta, B. C., Huang, M., Herman, D., Ozcan, A., & Altug, H. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.3 · Cited by 354
Self-citationHigh-throughput lensfree 3D tracking of human sperms reveals rare statistics of helical trajectories
Su, T.-W., Xue, L., & Ozcan, A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1212506109 · Cited by 339
Self-citationCost-effective and compact wide-field fluorescent imaging on a cell-phone
Zhu, H., Yaglidere, O., Su, T.-W., Tseng, D., & Ozcan, A. (2011) · Lab Chip · doi:10.1039/c0lc00358a · Cited by 330
Self-citationBarnard, K. J. (1998) · Optical Engineering · doi:10.1117/1.601623 · Cited by 324
Cellphone-based devices for bioanalytical sciences
Vashist, S. K., Mudanyali, O., Schneider, E. M., Zengerle, R., & Ozcan, A. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-013-7473-1 · Cited by 305
Self-citationWide-field computational imaging of pathology slides using lens-free on-chip microscopy
Greenbaum, A., Zhang, Y., Feizi, A., Chung, P.-L., Luo, W., Kandukuri, S. R., & Ozcan, A. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3009850 · Cited by 294
Self-citationHolographic pixel super-resolution in portable lensless on-chip microscopy using a fiber-optic array
Bishara, W., Sikora, U., Mudanyali, O., Su, T.-W., Yaglidere, O., Luckhart, S., & Ozcan, A. (2011) · Lab on a Chip · doi:10.1039/c0lc00684j · Cited by 288
Self-citationCholesterol testing on a smartphone
Oncescu, V., Mancuso, M., & Erickson, D. (2014) · Lab Chip · doi:10.1039/c3lc51194d · Cited by 279
Lensless high-resolution on-chip optofluidic microscopes for Caenorhabditis elegans and cell imaging
Cui, X., Lee, L. M., Heng, X., Zhong, W., Sternberg, P. W., Psaltis, D., & Yang, C. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0804612105 · Cited by 277
Cost-effective and rapid blood analysis on a cell-phone
Zhu, H., Sencan, I., Wong, J., Dimitrov, S., Tseng, D., Nagashima, K., & Ozcan, A. (2013) · Lab on a Chip · doi:10.1039/c3lc41408f · Cited by 274
Self-citationLensfree holographic imaging for on-chip cytometry and diagnostics
Seo, S., Su, T., Tseng, D. K., Erlinger, A., & Özcan, A. (2008) · Lab on a Chip · doi:10.1039/b813943a · Cited by 273
Synthetic aperture-based on-chip microscopy
Luo, W., Greenbaum, A., Zhang, Y., & Ozcan, A. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.34 · Cited by 257
Self-citationPlasmonic Sensing Characteristics of Single Nanometric Holes
Rindzevicius, T., Alaverdyan, Y., Dahlin, A., Höök, F., Sutherland, D. S., & Käll, M. (2005) · Nano Letters · doi:10.1021/nl0516355 · Cited by 243
Point-of-care quantification of blood-borne filarial parasites with a mobile phone microscope
D’Ambrosio, M. V., Bakalar, M., Bennuru, S., Reber, C., Skandarajah, A., Nilsson, L., Switz, N., Kamgno, J., Pion, S., Boussinesq, M., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa3480 · Cited by 237
Greenbaum, A., & Ozcan, A. (2012) · Optics Express · doi:10.1364/oe.20.003129 · Cited by 225
Self-citationLow-Cost Mobile Phone Microscopy with a Reversed Mobile Phone Camera Lens
Switz, N. A., D'Ambrosio, M. V., & Fletcher, D. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0095330 · Cited by 223
Su, J., Goldberg, A. F., & Stoltz, B. M. (2016) · Light: Science & Applications · doi:10.1038/lsa.2016.1 · Cited by 218
Lens-free optical tomographic microscope with a large imaging volume on a chip
Isikman, S. O., Bishara, W., Mavandadi, S., Yu, F. W., Feng, S., Lau, R., & Ozcan, A. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1015638108 · Cited by 216
Self-citationZheng, G., Lee, S. A., Antebi, Y., Elowitz, M. B., & Yang, C. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1110681108 · Cited by 209
Albumin testing in urine using a smart-phone
Coskun, A. F., Nagi, R., Sadeghi, K., Phillips, S., & Ozcan, A. (2013) · Lab on a Chip · doi:10.1039/c3lc50785h · Cited by 208
Self-citationKoydemir, H. C., Gorocs, Z., Tseng, D., Cortazar, B., Feng, S., Chan, R. Y. L., Burbano, J., McLeod, E., & Ozcan, A. (2015) · Lab on a Chip · doi:10.1039/c4lc01358a · Cited by 192
Self-citationA smartphone platform for the quantification of vitamin D levels
Lee, S., Oncescu, V., Mancuso, M., Mehta, S., & Erickson, D. (2014) · Lab Chip · doi:10.1039/c3lc51375k · Cited by 181
Imaging and Sizing of Single DNA Molecules on a Mobile Phone
Wei, Q., Luo, W., Chiang, S., Kappel, T., Mejia, C., Tseng, D., Chan, R. Y. L., Yan, E., Qi, H., Shabbir, F., et al. (2014) · ACS Nano · doi:10.1021/nn505821y · Cited by 169
Self-citationA mobile phone-based retinal camera for portable wide field imaging
Maamari, R. N., Keenan, J. D., Fletcher, D. A., & Margolis, T. P. (2014) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2013-303797 · Cited by 166
Wide-field optical detection of nanoparticles using on-chip microscopy and self-assembled nanolenses
Mudanyali, O., McLeod, E. J., Luo, W., Greenbaum, A., Coskun, A. F., Hennequin, Y., Allier, C. P., & Özcan, A. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.337 · Cited by 164
Self-citationHigh-Throughput Lens-Free Blood Analysis on a Chip
Seo, S., Isikman, S. O., Şencan, İ., Mudanyali, O., Su, T., Bishara, W., Erlinger, A., & Özcan, A. (2010) · Analytical Chemistry · doi:10.1021/ac1007915 · Cited by 153
Coskun, A. F., Çetin, A. E., Galarreta, B. C., Alvarez, D. A., Altug, H., & Özcan, A. (2014) · Scientific Reports · doi:10.1038/srep06789 · Cited by 153
Holographic opto-fluidic microscopy
Bishara, W., Zhu, H., & Özcan, A. (2010) · Optics Express · doi:10.1364/oe.18.027499 · Cited by 149
Lensless wide-field fluorescent imaging on a chip using compressive decoding of sparse objects
Coskun, A. F., Şencan, İ., Su, T., & Özcan, A. (2010) · Optics Express · doi:10.1364/oe.18.010510 · Cited by 149
Sub-pixel resolving optofluidic microscope for on-chip cell imaging
Zheng, G., Lee, S. A., Yang, S., & Yang, C. (2010) · Lab on a Chip · doi:10.1039/c0lc00213e · Cited by 145
Increased space-bandwidth product in pixel super-resolved lensfree on-chip microscopy
Greenbaum, A., Luo, W., Khademhosseinieh, B., Su, T., Coskun, A. F., & Özcan, A. (2013) · Scientific Reports · doi:10.1038/srep01717 · Cited by 144
Smart-phone based computational microscopy using multi-frame contact imaging on a fiber-optic array
Navruz, İ., Coskun, A. F., Wong, J., Mohammad, S., Tseng, D. K., Nagi, R., Phillips, S. W., & Özcan, A. (2013) · Lab on a Chip · doi:10.1039/c3lc50589h · Cited by 128
Solar thermal polymerase chain reaction for smartphone-assisted molecular diagnostics
Jiang, L., Mancuso, M., Lu, Z., Akar, G., Cesarman, E., & Erickson, D. (2014) · Scientific Reports · doi:10.1038/srep04137 · Cited by 126
Sperm Trajectories Form Chiral Ribbons
Su, T., Choi, I., Feng, J., Huang, K., McLeod, E. J., & Özcan, A. (2013) · Scientific Reports · doi:10.1038/srep01664 · Cited by 116
Self-citationGöröcs, Z. S., & Özcan, A. (2012) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2012.2215847 · Cited by 111
A cell-based biosensor for real-time detection of cardiotoxicity using lensfree imaging
Kim, S. B., Bae, H., Cha, J. M., Moon, S. J., Dokmeci, M. R., Cropek, D. M., & Khademhosseini, A. (2011) · Lab on a Chip · doi:10.1039/c1lc20098d · Cited by 96
Wide field-of-view lens-free fluorescent imaging on a chip
Coskun, A. F., Su, T., & Özcan, A. (2010) · Lab on a Chip · doi:10.1039/b926561a · Cited by 93
Coskun, A. F., Şencan, İ., Su, T., & Özcan, A. (2011) · PLoS ONE · doi:10.1371/journal.pone.0015955 · Cited by 90
Field-portable lensfree tomographic microscope
Isikman, S. O., Bishara, W., Sikora, U., Yaglidere, O., Yeah, J., & Özcan, A. (2011) · Lab on a Chip · doi:10.1039/c1lc20127a · Cited by 90
Ludwig, S. K. J., Zhu, H., Phillips, S. W., Shiledar, A., Feng, S. W., Tseng, D. K., van Ginkel, L. A., Nielen, M. W. F., & Özcan, A. (2014) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-014-7984-4 · Cited by 90
High-Throughput and Label-Free Single Nanoparticle Sizing Based on Time-Resolved On-Chip Microscopy
McLeod, E. J., Dincer, T. U., Veli, M., Ertaş, Y. N., Nguyen, C., Luo, W., Greenbaum, A., Feizi, A., & Özcan, A. (2015) · ACS Nano · doi:10.1021/acsnano.5b00388 · Cited by 85
Self-citationLee, S. A., Leitao, R. M., Zheng, G., Yang, S., Rodríguez, A., & Yang, C. (2011) · PLoS ONE · doi:10.1371/journal.pone.0026127 · Cited by 80
Automated single-cell motility analysis on a chip using lensfree microscopy
Pushkarsky, I., Liu, Y., Weaver, W. M., Su, T., Mudanyali, O., Özcan, A., & Carlo, D. D. (2014) · Scientific Reports · doi:10.1038/srep04717 · Cited by 79
High-throughput monitoring of major cell functions by means of lensfree video microscopy
Kesavan, S. V., Momey, F., Cioni, O., David‐Watine, B., Dubrulle, N., Shorte, S. L., Sulpice, E., Freida, D., Chalmond, B., Dinten, J., et al. (2014) · Scientific Reports · doi:10.1038/srep05942 · Cited by 75
Huang, X., Guo, J., Wang, X., Mei, Y., Kang, Y., & Yu, H. (2014) · PLoS ONE · doi:10.1371/journal.pone.0104539 · Cited by 74
Integrated immunoassay using tuneable surface acoustic waves and lensfree detection
Bourquin, Y., Reboud, J., Wilson, R., Zhang, Y., & Cooper, J. M. (2011) · Lab on a Chip · doi:10.1039/c1lc20320g · Cited by 73
Giga-Pixel Lensfree Holographic Microscopy and Tomography Using Color Image Sensors
Isikman, S. O., Greenbaum, A., Luo, W., Coskun, A. F., & Özcan, A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0045044 · Cited by 61
Lensfree super-resolution holographic microscopy using wetting films on a chip
Mudanyali, O., Bishara, W., & Özcan, A. (2011) · Optics Express · doi:10.1364/oe.19.017378 · Cited by 59
Novel Telemedicine Device for Diagnosis of Corneal Abrasions and Ulcers in Resource-Poor Settings
Maamari, R. N., Ausayakhun, S., Margolis, T. P., Fletcher, D. A., & Keenan, J. D. (2014) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2014.335 · Cited by 56
McLeod, E. J., Luo, W., Mudanyali, O., Greenbaum, A., & Özcan, A. (2013) · Lab on a Chip · doi:10.1039/c3lc50222h · Cited by 56
Self-citationColor and monochrome lensless on-chip imaging of Caenorhabditis elegans over a wide field-of-view
Isikman, S. O., Şencan, İ., Mudanyali, O., Bishara, W., Oztoprak, C., & Özcan, A. (2010) · Lab on a Chip · doi:10.1039/c001200a · Cited by 53
Arpali, S. A., Arpali, Ç., Coskun, A. F., Chiang, H.-H., & Özcan, A. (2012) · Lab on a Chip · doi:10.1039/c2lc40894e · Cited by 53
Bacteria detection with thin wetting film lensless imaging
Allier, C. P., Hiernard, G., Poher, V., & Dinten, J. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000762 · Cited by 52
Roy, M., Seo, D., Oh, C.-H., Nam, M., Kim, Y. J., & Seo, S. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.10.040 · Cited by 51
Democratization of Nanoscale Imaging and Sensing Tools Using Photonics
McLeod, E. J., Wei, Q., & Özcan, A. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b01381 · Cited by 47
Self-citationHan, C., Pang, S., Bower, D. V., Yiu, P., & Yang, C. (2013) · Analytical Chemistry · doi:10.1021/ac303356v · Cited by 46
Imaging and Identification of Waterborne Parasites Using a Chip-Scale Microscope
Lee, S. A., Erath, J., Zheng, G., Ou, X., Willems, P. A., Eichinger, D. J., Rodrı́guez, A., & Yang, C. (2014) · PLoS ONE · doi:10.1371/journal.pone.0089712 · Cited by 40
Label-free analysis of prostate acini-like 3D structures by lensfree imaging
Dolega, M. E., Allier, C. P., Kesavan, S. V., Gerbaud, S., Kermarrec, F., Marcoux, P. R., Dinten, J., Gidrol, X., & Picollet-D’hahan, N. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.05.001 · Cited by 34
High-content analysis of single cells directly assembled on CMOS sensor based on color imaging
Tanaka, T., Saeki, T., Sunaga, Y., & Matsunaga, T. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.07.081 · Cited by 33
Spectral Demultiplexing in Holographic and Fluorescent On-chip Microscopy
Şencan, İ., Coskun, A. F., Sikora, U., et al. (2014) · Scientific Reports · doi:10.1038/srep03760 · Cited by 27
Lensfree sensing on a microfluidic chip using plasmonic nanoapertures
Khademhosseinieh, B., Biener, G., Şencan, İ., Su, T., Coskun, A. F., & Özcan, A. (2010) · Applied Physics Letters · doi:10.1063/1.3521390 · Cited by 23
Real-time label-free detection of dividing cells by means of lensfree video-microscopy
Kesavan, S. V., Navarro, F. P., Menneteau, M., Mittler, F., David‐Watine, B., Dubrulle, N., Shorte, S. L., Chalmond, B., Dinten, J., & Allier, C. P. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.3.036004 · Cited by 22
Partially coherent lensfree tomographic microscopy [Invited]
Isikman, S. O., Bishara, W., & Özcan, A. (2011) · Applied Optics · doi:10.1364/ao.50.00h253 · Cited by 17
Single-cell detection using a thin film transistor photosensor with micro-partitions
Tanaka, T., Sunaga, Y., Hatakeyama, K., & Matsunaga, T. (2010) · Lab on a Chip · doi:10.1039/c0lc00039f · Cited by 11
Growth phenotype screening of Schizosaccharomyces pombe using a Lensless microscope
Penwill, L. A., Batten, G. E., Castagnetti, S., & Shaw, A. M. (2013) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.11.010 · Cited by 3
Cited by
All-optical machine learning using diffractive deep neural networks
Lin, X., Rivenson, Y., Yardimci, N. T., Veli, M., Luo, Y., Jarrahi, M., & Ozcan, A. (2018) · Science · doi:10.1126/science.aat8084 · Cited by 2,568
“For example, integration of a D 2 NN with lensfree on-chip imaging ( 26 - 28 ) or detection systems could provide extreme parallelism within a compact and field-portable chip-scale system with a neural network detection field-of-view of e.g., >18 cm 2 that can be routinely achieved using…”
Modulation of Immune Responses by Particle Size and Shape
Baranov, M. V., Kumar, M., Sacanna, S., Thutupalli, S., & van den Bogaart, G. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2020.607945 · Cited by 324
Roadmap on digital holography [Invited]
Javidi, B., Carnicer, A., Anand, A., Barbastathis, G., Chen, W., Ferraro, P., Goodman, J. W., Horisaki, R., Khare, K., Kujawinska, M., et al. (2021) · Optics Express · doi:10.1364/oe.435915 · Cited by 309
Self-citationSmartphone-based analytical biosensors
Huang, X., Xu, D., Chen, J., Liu, J., Li, Y., Song, J., Ma, X., & Guo, J. (2018) · The Analyst · doi:10.1039/c8an01269e · Cited by 305
Mait, J. N., Euliss, G. W., & Athale, R. A. (2018) · Advances in Optics and Photonics · doi:10.1364/aop.10.000409 · Cited by 289
Metadata
- Authors
- Ozcan, A., & McLeod, E.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2016-07-11
- Volume
- 18
- Issue
- 1
- Pages
- 77-102
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2249493152
- Cited by
- 352
- References
- 92
- FWCI
- 1.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.