Total Internal Reflection Fluorescence
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Total internal reflection fluorescence (TIRF) is an optical effect particularly well-suited to the study of molecular and cellular phenomena at liquid/solid interfaces. Such interfaces are central to a wide range of biochemical and biophysical processes: binding to and triggering of ceils by hormones, neurotransmitters, and antigens; blood coagulation at foreign surfaces; electron transport in the mitochondrial membrane; adherence and mobility of bacteria, algae, and cultured animal cells to surfaces; and possible enhancement of reaction rates with cell surface receptors upon nonspecific adsorption and surface diffusion of an agonist. Liquid/solid interfaces also have important medical and industrial applications: e.g. detection of serum antibodies by surface immobilized antigens; and the manufacture of biochemical products by surface-immobilized enzymes. Total internal reflection spectroscopy for optical absorption studies (called attenuated total reflection or ATR) was developed somewhat earlier than the fluorescence applications and has been widely used in surface
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
A simple method of reducing the fading of immunofluorescence during microscopy
Johnson, G. D., & de C. Nogueira Araujo, G. M. (1981) · Journal of Immunological Methods · doi:10.1016/0022-1759(81)90183-6 · Cited by 1,863
Berg, H. C., & Purcell, E. M. (1977) · Biophysical Journal · doi:10.1016/s0006-3495(77)85544-6 · Cited by 1,758
Internal Reflection Spectroscopy
Harrick, N. J., & Hoffman, J. G. (1968) · Physics Today · doi:10.1063/1.3034675 · Cited by 1,723
Structural chemistry and molecular biology
Rich, A., Davidson, N., & Pauling, L. C. (1968) · Medical Entomology and Zoology · Cited by 1,702
Electromagnetic interactions of molecules with metal surfaces
Ford, G. W., & Weber, W. H. (1984) · Physics Reports · doi:10.1016/0370-1573(84)90098-x · Cited by 965
Cell-substrate contacts illuminated by total internal reflection fluorescence.
Axelrod, D. (1981) · The Journal of cell biology · doi:10.1083/jcb.89.1.141 · Cited by 832
Self-citationInfluence of a dielectric interface on fluorescence decay time
Drexhage, K. H. (1970) · Journal of Luminescence · doi:10.1016/0022-2313(70)90082-7 · Cited by 732
Classical Aspects of Energy Transfer in Molecular Systems
Kuhn, H. (1970) · The Journal of Chemical Physics · doi:10.1063/1.1673749 · Cited by 632
Light emission by magnetic and electric dipoles close to a plane interface I Total radiated power
Lukosz, W., & Kunz, R. E. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.001607 · Cited by 469
Cited by
Radiative Decay Engineering: Biophysical and Biomedical Applications
Lakowicz, J. R. (2001) · Analytical Biochemistry · doi:10.1006/abio.2001.5377 · Cited by 1,217
INTERFACES AND THIN FILMS AS SEEN BY BOUND ELECTROMAGNETIC WAVES
Knoll, W. (1998) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.49.1.569 · Cited by 1,011
Methods of single-molecule fluorescence spectroscopy and microscopy
Moerner, W. E., & Fromm, D. P. (2003) · Review of Scientific Instruments · doi:10.1063/1.1589587 · Cited by 881
Optimized localization analysis for single-molecule tracking and super-resolution microscopy
Mortensen, K. I., Churchman, L. S., Spudich, J. A., & Flyvbjerg, H. (2010) · Nature Methods · doi:10.1038/nmeth.1447 · Cited by 871
Single-Molecule Optomechanical Cycle
Hugel, T., Holland, N. B., Cattani, A., Moroder, L., Seitz, M., & Gaub, H. E. (2002) · Science · doi:10.1126/science.1069856 · Cited by 836
Protein adsorption and materials biocompatibility: A tutorial review and suggested hypotheses
Andrade, J. D., & Hlady, V. (1986) · Advances in Polymer Science · doi:10.1007/3-540-16422-7_6 · Cited by 810
Chiral nanophotonic waveguide interface based on spin-orbit interaction of light
Petersen, J., Volz, J., & Rauschenbeutel, A. (2014) · Science · doi:10.1126/science.1257671 · Cited by 807
From transverse angular momentum to photonic wheels
Aiello, A., Banzer, P., Neugebauer, M., & Leuchs, G. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.203 · Cited by 639
Supported planar membranes in studies of cell-cell recognition in the immune system
McConnell, H. M., Watts, T. H., Weis, R. M., & Brian, A. A. (1986) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(86)90016-x · Cited by 561
Fluorescence Techniques for Studying Protein Structure
Eftink, M. R. (1991) · Methods of Biochemical Analysis · doi:10.1002/9780470110560.ch3 · Cited by 504
Imaging Live-Cell Dynamics and Structure at the Single-Molecule Level
Liu, Z., Lavis, L. D., & Betzig, E. (2015) · Molecular Cell · doi:10.1016/j.molcel.2015.02.033 · Cited by 486
Radiative decay engineering 3. Surface plasmon-coupled directional emission
Lakowicz, J. R. (2004) · Analytical Biochemistry · doi:10.1016/j.ab.2003.09.039 · Cited by 462
Three-dimensional structural dynamics of myosin V by single-molecule fluorescence polarization
Forkey, J. N., Quinlan, M. E., Alexander Shaw, M., Corrie, J. E. T., & Goldman, Y. E. (2003) · Nature · doi:10.1038/nature01529 · Cited by 455
Imaging exocytosis and endocytosis
Betz, W. J., Mao, F., & Smith, C. B. (1996) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(96)80121-8 · Cited by 445
Chapter 9 Total Internal Reflection Fluorescence Microscopy
(1989) · Methods in Cell Biology · doi:10.1016/s0091-679x(08)60982-6 · Cited by 374
Kinase-regulated quantal assemblies and kiss-and-run recycling of caveolae
Pelkmans, L., & Zerial, M. (2005) · Nature · doi:10.1038/nature03866 · Cited by 352
Implant Surfaces and Interface Processes
Kasemo, B., & Gold, J. (1999) · Advances in Dental Research · doi:10.1177/08959374990130011901 · Cited by 317
Iino, R., Koyama, I., & Kusumi, A. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76236-4 · Cited by 306
Strong Coupling between Single Atoms and Nontransversal Photons
Junge, C., O’Shea, D., Volz, J., & Rauschenbeutel, A. (2013) · Physical Review Letters · doi:10.1103/physrevlett.110.213604 · Cited by 305
Super-Resolution Imaging and Plasmonics
Willets, K. A., Wilson, A. J., Sundaresan, V., & Joshi, P. B. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00547 · Cited by 301
Scattering Lens Resolves Sub-100 nm Structures with Visible Light
van Putten, E. G., Akbulut, D., Bertolotti, J., Vos, W. L., Lagendijk, A., & Mosk, A. P. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.193905 · Cited by 299
Lighting up the cell surface with evanescent wave microscopy
Toomre, D., & Manstein, D. J. (2001) · Trends in Cell Biology · doi:10.1016/s0962-8924(01)02027-x · Cited by 276
Mathur, A. B., Truskey, G. A., & Monty Reichert, W. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76724-5 · Cited by 269
Microtubule Dynamics Reconstituted In Vitro and Imaged by Single-Molecule Fluorescence Microscopy
Gell, C., Bormuth, V., Brouhard, G. J., Cohen, D. N., Diez, S., Friel, C. T., Helenius, J., Nitzsche, B., Petzold, H., Ribbe, J., et al. (2010) · Methods in Cell Biology · doi:10.1016/s0091-679x(10)95013-9 · Cited by 261
Fluorescence microphotolysis to measure nucleocytoplasmic transport and intracellular mobility
Peters, R. (1986) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(86)90003-1 · Cited by 246
Fluorescence emission at dielectric and metal-film interfaces
Hellen, E. H., & Axelrod, D. (1987) · Journal of the Optical Society of America B · doi:10.1364/josab.4.000337 · Cited by 241
Self-citationSimultaneous, coincident optical trapping and single-molecule fluorescence
Lang, M. J., Fordyce, P. M., Engh, A. M., Neuman, K. C., & Block, S. M. (2004) · Nature Methods · doi:10.1038/nmeth714 · Cited by 230
“4-NA oil/IR , Nikon Biomedical ; 61% transmission at 1,064 nm”
BackgroundImaging Three-Dimensional Single Molecule Orientations
Bartko, A. P., & Dickson, R. M. (1999) · The Journal of Physical Chemistry B · doi:10.1021/jp993364q · Cited by 225
Magnetic biosensor technologies for medical applications: a review
Llandro, J., Palfreyman, J. J., Ionescu, A., & Barnes, C. H. W. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0649-3 · Cited by 222
“For example, total internal reflectance fluorescence (TIRF) detection [4] diverts the majority of the excitation light by total internal reflection through the edge of the substrate and collects only the emitted fluorescence in transmission; this method requires both an intense, collimated light source (usually a lase…”
BackgroundSteyer, J. A., & Almers, W. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77382-0 · Cited by 207
Receptor–ligand binding assays: Technologies and Applications
de Jong, L. A. A., Uges, D. R. A., Franke, J. P., & Bischoff, R. (2005) · Journal of Chromatography B · doi:10.1016/j.jchromb.2005.10.002 · Cited by 205
A Membrane Marker Leaves Synaptic Vesicles in Milliseconds after Exocytosis in Retinal Bipolar Cells
Zenisek, D., Steyer, J. A., Feldman, M. E., & Almers, W. (2002) · Neuron · doi:10.1016/s0896-6273(02)00896-6 · Cited by 188
Hamilton, B. S., Whittaker, G. R., & Daniel, S. (2012) · Viruses · doi:10.3390/v4071144 · Cited by 187
“These new assays employ total internal reflection fluorescence microscopy (TIRF) [125], a surface-specific technique that illuminates about a 100 nm thick layer from the interface of a change in refractive”
MethodInfluentialDickson, R. M., Norris, D. J., & Moerner, W. E. (1998) · Physical Review Letters · doi:10.1103/physrevlett.81.5322 · Cited by 186
Automatic Detection of Single Fluorophores in Live Cells
Mashanov, G. I., & Molloy, J. E. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.081117 · Cited by 185
“We know that PLC-δ1 binds tightly and specifically to (PI(4,5)P2) whereas PH123 are more promiscuous binding to (PI(3,4,5)P3) and (PI(3,5)P2) (Dr.”
BackgroundMethodInfluentialThe last few milliseconds in the life of a secretory granule
Oheim, M., Loerke, D., Stühmer, W., & Chow, R. H. (1998) · European Biophysics Journal · doi:10.1007/s002490050114 · Cited by 183
Li, J., Zhou, N., Sun, J., Zhou, S., Bai, Z., Lu, L., Chen, Q., & Zuo, C. (2022) · Light: Science & Applications · doi:10.1038/s41377-022-00815-7 · Cited by 171
Buijs, J., & Hlady, V. (1997) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1997.4876 · Cited by 168
Super-Resolution Microscopy: Shedding Light on the Cellular Plasma Membrane
Stone, M. B., Shelby, S. A., & Veatch, S. L. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00716 · Cited by 165
Single-Molecule Fluorescence Spectroscopy of Photosynthetic Systems
Kondo, T., Chen, W. J., & Schlau-Cohen, G. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00195 · Cited by 120
Mapping Dynamic Protein Interactions to Insulin Secretory Granule Behavior with TIRF-FRET
Lam, A. D., Ismail, S., Wu, R., Yizhar, O., Passmore, D. R., Ernst, S. A., & Stuenkel, E. L. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2010.06.014 · Cited by 23
“(Markers) Mean 5 SE (n 1⁄4 purple, green, black): a (7,7,12); b (6,8,6); and x, g, EA, ED, Ratio (7,4,10).”
Metadata
- Authors
- Axelrod, D., Burghardt, T. P., & Thompson, N. L.
- Venue
- Annual Review of Biophysics and Bioengineering
- Publisher
- Annual Reviews
- Published
- 1984-06
- Volume
- 13
- Issue
- 1
- Pages
- 247-268
- ISSN
- 0084-6589 (ISSN-L)
- OpenAlex
- W2096963388
- Cited by
- 741
- References
- 25
- FWCI
- 8.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.