Fluid Mechanics of Heart Valves
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
▪ Abstract Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical analysis of blood flow in the heart
Peskin, C. S. (1977) · Journal of Computational Physics · doi:10.1016/0021-9991(77)90100-0 · Cited by 3,084
Flow patterns around heart valves: A numerical method
Peskin, C. S. (1972) · Journal of Computational Physics · doi:10.1016/0021-9991(72)90065-4 · Cited by 3,047
The Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,599
Sarnoff, S. J., Braunwald, E., Welch, G. H., Case, R. B., Stainsby, W. N., & Macruz, R. (1957) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1957.192.1.148 · Cited by 1,319
Oh, J. K., Appleton, C. P., Hatle, L. K., Nishimura, R. A., Seward, J. B., & Tajik, A. J. (1997) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(97)70062-2 · Cited by 629
Kilner, P. J., Yang, G. Z., Mohiaddin, R. H., Firmin, D. N., & Longmore, D. B. (1993) · Circulation · doi:10.1161/01.cir.88.5.2235 · Cited by 592
Otsuji, Y., Handschumacher, M. D., Schwammenthal, E., Jiang, L., Song, J.-K., Guerrero, J. L., Vlahakes, G. J., & Levine, R. A. (1997) · Circulation · doi:10.1161/01.cir.96.6.1999 · Cited by 592
Levine, R. A., Handschumacher, M. D., Sanfilippo, A. J., Hagege, A. A., Harrigan, P., Marshall, J. E., & Weyman, A. E. (1989) · Circulation · doi:10.1161/01.cir.80.3.589 · Cited by 556
Peskin, C. S., & McQueen, D. M. (1989) · Journal of Computational Physics · doi:10.1016/0021-9991(89)90213-1 · Cited by 485
Ormiston, J. A., Shah, P. M., Tei, C., & Wong, M. (1981) · Circulation · doi:10.1161/01.cir.64.1.113 · Cited by 464
Practice of Clinical Echocardiography
(2017) · Elsevier eBooks · doi:10.1016/c2014-0-03591-5 · Cited by 463
He, S., Fontaine, A. A., Schwammenthal, E., Yoganathan, A. P., & Levine, R. A. (1997) · Circulation · doi:10.1161/01.cir.96.6.1826 · Cited by 396
Self-citationA three-dimensional computational analysis of fluid–structure interaction in the aortic valve
De Hart, J., Peters, G. W. M., Schreurs, P. J. G., & Baaijens, F. P. T. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00244-0 · Cited by 386
Descent of the Base of the Left Ventricle: An Echocardiographic Index of Left Ventricular function
Simonson, J. S., & Schiller, N. B. (1989) · Journal of the American Society of Echocardiography · doi:10.1016/s0894-7317(89)80026-4 · Cited by 280
Human red blood cell hemolysis in a turbulent shear flow: Contribution of Reynolds shear stresses
Sallam, A. M., & Hwang, N. H. C. (1984) · Biorheology · doi:10.3233/bir-1984-21605 · Cited by 245
Modeling prosthetic heart valves for numerical analysis of blood flow in the heart
Peskin, C. S., & McQueen, D. M. (1980) · Journal of Computational Physics · doi:10.1016/0021-9991(80)90007-8 · Cited by 194
Gorman, J. H., Gupta, K. B., Streicher, J. T., Gorman, R. C., Jackson, B. M., Ratcliffe, M. B., Bogen, D. K., & Edmunds, L. H. (1996) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(96)70056-9 · Cited by 191
Size and motion of the mitral valve annulus in anesthetized intact dogs.
Tsakiris, A. G., Von Bernuth, G., Rastelli, G. C., Bourgeois, M. J., Titus, J. L., & Wood, E. H. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.30.5.611 · Cited by 184
Case Studies in Mathematical Modeling: Ecology, Physiology, and Cell Biology
Othmer, H. G., Adler, F. R., Lewis, M. A., & Dallon, J. C. (1996) · Cited by 177
Requirements for Mesh Resolution in 3D Computational Hemodynamics
Prakash, S., & Ethier, C. R. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1351807 · Cited by 172
Krafczyk, M., Cerrolaza, M., Schulz, M., & Rank, E. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00036-0 · Cited by 136
Leaflet fracture in Edwards-Duromedics bileaflet valves
Klepetko, W., Moritz, A., Mlczoch, J., Schurawitzki, H., Domanig, E., & Wolner, E. (1989) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(19)35130-x · Cited by 131
Differential collagen distribution in the mitral valve and its influence on biomechanical behaviour.
Kunzelman, K. S., Cochran, R. P., Murphree, S. S., Ring, W. S., Verrier, E. D., & Eberhart, R. C. (1993) · PubMed · Cited by 125
The Biomedical Engineering Handbook: Second Edition.
Henriquez, C. S. (1999) · The electrical engineering handbook/Electrical engineering handbook series/Electrical engineering handbook · doi:10.1201/9781420049510.sec2 · Cited by 125
A three-dimensional computational method for blood flow in the heart. II. contractile fibers
McQueen, D. M., & Peskin, C. S. (1989) · Journal of Computational Physics · doi:10.1016/0021-9991(89)90050-8 · Cited by 121
Papillary muscle traction in mitral valve prolapse: Quantitation by two-dimensional echocardiography
Sanfilippo, A. J., Harrigan, P., Popović, A. D., Weyman, A. E., & Levine, R. A. (1992) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(10)80274-8 · Cited by 118
Fluid Dynamics of the Heart and its Valves
Peskin, C. S., & McQueen, D. M. (1996) · Cited by 116
Quantitative cardiovascular studies : clinical and research applications of engineering principles
Hwang, N. H. C., Gross, D. R., & Patel, D. J. (1979) · Andalas University Repository (Andalas University) · Cited by 91
A vortex method for blood flow through heart valves
McCracken, M. F., & Peskin, C. S. (1980) · Journal of Computational Physics · doi:10.1016/0021-9991(80)90085-6 · Cited by 69
Kim, W. Y., Bisgaard, T., Nielsen, S. L., Poulsen, J. K., Pedersen, E. M., Hasenkam, J. M., & Yoganathan, A. P. (1994) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(94)90314-x · Cited by 42
Self-citationComputer graphics analysis of stresses in blood flow through a prosthetic heart valve
Au, A. D. K., & Greenfield, H. S. (1975) · Computers in Biology and Medicine · doi:10.1016/0010-4825(75)90039-6 · Cited by 19
Cited by
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
“Disturbed flow may also occur in the aortic side of the valvular leaflets, which may regulate valvular endothelial signaling and phenotype that contribute to the preferential susceptibility to lesion development in this region (58, 129, 636).”
BackgroundGe, L., & Sotiropoulos, F. (2007) · Journal of Computational Physics · doi:10.1016/j.jcp.2007.02.017 · Cited by 405
FLUID MECHANICS OF ARTIFICIAL HEART VALVES
Dasi, L. P., Simon, H. A., Sucosky, P., & Yoganathan, A. P. (2009) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2008.05099.x · Cited by 286
Self-citationDavis, M. J., Earley, S., Li, Y.-S., & Chien, S. (2023) · Physiological Reviews · doi:10.1152/physrev.00053.2021 · Cited by 273
Sun, J. C., Davidson, M. J., Lamy, A., & Eikelboom, J. W. (2009) · The Lancet · doi:10.1016/s0140-6736(09)60780-7 · Cited by 241
Metadata
- Authors
- Yoganathan, A. P., He, Z., & Casey Jones, S.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2004-08-15
- Volume
- 6
- Issue
- 1
- Pages
- 331-362
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2150738582
- Cited by
- 389
- References
- 31
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.