Volume CT Dose Index and Dose-Length Product Displayed during CT: What Good Are They?
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The average medical radiation effective dose to the U.S. population in 2006 was estimated at approximately 3.0 mSv, an increase of 600% in a single generation. Computed tomography (CT) alone accounts for approximately half of this medical radiation dose. Ongoing advances suggest that CT will continue to be the most important contributor, by far, to medical doses in the United States. The use of ionizing radiation in medical imaging, including CT, provides valuable diagnostic information that undoubtedly benefits many patients. Exposure to radiation, however, is currently believed to carry a small, but nonzero, risk. Accordingly, the medical imaging community must ensure that the benefits of a radiologic examination in any given patient exceed the corresponding risks. It is also the responsibility of the radiologist to ensure that no more radiation is used than needed for obtaining diagnostic information in any radiologic examination, especially CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ngaile, J. E., Msaki, P., & Kazema, R. (2006) · Journal of Radiological Protection · doi:10.1088/0952-4746/26/2/006 · Cited by 37
Cited by
CT effective dose per dose length product using ICRP 103 weighting factors
Huda, W., Magill, D., & He, W. (2011) · Medical Physics · doi:10.1118/1.3544350 · Cited by 173
Self-citationBrady, S. L., & Kaufman, R. A. (2012) · Radiology · doi:10.1148/radiol.12120131 · Cited by 137
Ekpo, E. U., Adejoh, T., Akwo, J. D., Emeka, O. C., Modu, A. A., Abba, M., Adesina, K. A., Omiyi, D. O., & Chiegwu, U. H. (2018) · Journal of Radiological Protection · doi:10.1088/1361-6498/aaaaf8 · Cited by 61
Liang, C. R., Chen, P. X. H., Kapur, J., Ong, M. K. L., Quek, S. T., & Kapur, S. C. (2017) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.210 · Cited by 33
“The effective dose (ED) is a quantity which is a risk metric and the computation of ED is performed by estimating organ absorbed dose, and then multiplying each of those by a tissue weighting factor.(11) These weighting factors are”
MethodVarghese, B., Kandanga, I., Puthussery, P., Vijayan, D., Babu, S. P. H., Aneesh, M. K., Noufal, M., Binu, E. V., Babu, A. C., James, S. M., et al. (2018) · Indian Journal of Radiology and Imaging · doi:10.4103/ijri.ijri_394_17 · Cited by 12
“[27] The DRLs and median doses of 128‑slice CT equipment are higher than that of corresponding values of a 16‑slice CT, in this study.”
Optimization of CT radiation dose: Insight into DLP and CTDI
Arfat, M., Haq, A., Beg, T., & Jaleel, G. (2024) · Future Health · doi:10.25259/fh_45_2024 · Cited by 10
Establishment of diagnostic reference levels in computed tomography in two large hospitals in Oman
Bouchareb, Y., Al-Maimani, A., Al-Balushi, A.-Y., Al-Kalbani, M., Al-Maskari, H., Al-Dhuhli, H., & Al-Kindi, F. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad225 · Cited by 7
Metadata
- Authors
- Huda, W., & Mettler, F. A.
- Venue
- Radiology
- Published
- 2011-01
- Volume
- 258
- Issue
- 1
- Pages
- 236-242
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2111290364
- Cited by
- 208
- References
- 1
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.