CoChat

Volume CT Dose Index and Dose-Length Product Displayed during CT: What Good Are They?

Huda, Walter, Mettler, Fred A. · 2011 · Radiology
Cited by 208

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The average medical radiation effective dose to the U.S. population in 2006 was estimated at approximately 3.0 mSv, an increase of 600% in a single generation. Computed tomography (CT) alone accounts for approximately half of this medical radiation dose. Ongoing advances suggest that CT will continue to be the most important contributor, by far, to medical doses in the United States. The use of ionizing radiation in medical imaging, including CT, provides valuable diagnostic information that undoubtedly benefits many patients. Exposure to radiation, however, is currently believed to carry a small, but nonzero, risk. Accordingly, the medical imaging community must ensure that the benefits of a radiologic examination in any given patient exceed the corresponding risks. It is also the responsibility of the radiologist to ensure that no more radiation is used than needed for obtaining diagnostic information in any radiologic examination, especially CT.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.10100297

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

Metadata

Authors
Huda, W., & Mettler, F. A.
Venue
Radiology
Published
2011-01
Volume
258
Issue
1
Pages
236-242
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2111290364
Cited by
208
References
1
FWCI
7.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.