Prostate Cancer: Multiparametric MR Imaging for Detection, Localization, and Staging
Open accessThe DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.
Abstract
This review presents the current state of the art regarding multiparametric magnetic resonance (MR) imaging of prostate cancer. Technical requirements and clinical indications for the use of multiparametric MR imaging in detection, localization, characterization, staging, biopsy guidance, and active surveillance of prostate cancer are discussed. Although reported accuracies of the separate and combined multiparametric MR imaging techniques vary for diverse clinical prostate cancer indications, multiparametric MR imaging of the prostate has shown promising results and may be of additional value in prostate cancer localization and local staging. Consensus on which technical approaches (field strengths, sequences, use of an endorectal coil) and combination of multiparametric MR imaging techniques should be used for specific clinical indications remains a challenge. Because guidelines are currently lacking, suggestions for a general minimal protocol for multiparametric MR imaging of the prostate based on the literature and the authors' experience are presented. Computer programs that allow evaluation of the various components of a multiparametric MR imaging examination in one view should be developed. In this way, an integrated interpretation of anatomic and functional MR imaging techniques in a multiparametric MR imaging examination is possible. Education and experience of specialist radiologists are essential for correct interpretation of multiparametric prostate MR imaging findings. Supportive techniques, such as computer-aided diagnosis are needed to obtain a fast, cost-effective, easy, and more reproducible prostate cancer diagnosis out of more and more complex multiparametric MR imaging data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jemal, A., Bray, F., Center, M. M., Ferlay, J., Ward, E., & Forman, D. (2011) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.20107 · Cited by 54,679
Global Cancer Statistics, 2002
Parkin, D. M., Bray, F., Ferlay, J., & Pisani, P. (2005) · CA: A Cancer Journal for Clinicians · doi:10.3322/canjclin.55.2.74 · Cited by 18,196
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Epstein, J. I., Allsbrook, W. C., Amin, M. B., & Egevad, L. L. (2005) · American Journal of Surgical Pathology · doi:10.1097/01.pas.0000173646.99337.b1 · Cited by 2,763
Gleason, D. F., Mellinger, G. T., & The Veterans Administration Cooperative Urological Research Group Members of this group areS0022534717598894-57c401330b4195dbd1713587ed540477 Lino J. Arduino Veterans Administration Center (VAC), D. M. (1974) · Journal of Urology · doi:10.1016/s0022-5347(17)59889-4 · Cited by 2,214
THE THEORY AND APPLICATIONS OF THE EXCHANGE OF INERT GAS AT THE LUNGS AND TISSUES
KETY, S. S. (1951) · Pharmacological Reviews · doi:10.1016/s0031-6997(25)07246-1 · Cited by 1,663
Catalona, W. J., Richie, J. P., Ahmann, F. R., Hudson, M. A., Scardino, P. T., Flanigan, R. C., Dekernion, J. B., Ratliff, T. L., Kavoussi, L. R., Dalkin, B. L., et al. (1994) · Journal of Urology · doi:10.1016/s0022-5347(17)35233-3 · Cited by 1,592
Modeling tracer kinetics in dynamic Gd‐DTPA MR imaging
Tofts, P. S. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070113 · Cited by 1,478
Klotz, L., Zhang, L., Lam, A., Nam, R., Mamedov, A., & Loblaw, A. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.24.2180 · Cited by 1,074
Cited by
3D Slicer as an image computing platform for the Quantitative Imaging Network
Fedorov, A., Beichel, R., Kalpathy-Cramer, J., Finet, J., Fillion-Robin, J.-C., Pujol, S., Bauer, C., Jennings, D., Fennessy, F., Sonka, M., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.05.001 · Cited by 9,023
Multimodal Data Fusion: An Overview of Methods, Challenges, and Prospects
Lahat, D., Adali, T., & Jutten, C. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2460697 · Cited by 1,296
“One of the main challenges is the automation of such decision procedures, in order to improve correct interpretation, as well as save costs and time [35].”
Fütterer, J. J., Briganti, A., De Visschere, P., Emberton, M., Giannarini, G., Kirkham, A., Taneja, S. S., Thoeny, H., Villeirs, G., & Villers, A. (2015) · European Urology · doi:10.1016/j.eururo.2015.01.013 · Cited by 785
Self-citationSimultaneous 68Ga-PSMA HBED-CC PET/MRI Improves the Localization of Primary Prostate Cancer
Eiber, M., Weirich, G., Holzapfel, K., Souvatzoglou, M., Haller, B., Rauscher, I., Beer, A. J., Wester, H.-J., Gschwend, J., Schwaiger, M., et al. (2016) · European Urology · doi:10.1016/j.eururo.2015.12.053 · Cited by 568
Image-Guided Prostate Biopsy Using Magnetic Resonance Imaging–Derived Targets: A Systematic Review
Moore, C. M., Robertson, N. L., Arsanious, N., Middleton, T., Villers, A., Klotz, L., Taneja, S. S., & Emberton, M. (2013) · European Urology · doi:10.1016/j.eururo.2012.06.004 · Cited by 535
Accuracy of Multiparametric MRI for Prostate Cancer Detection: A Meta-Analysis
de Rooij, M., Hamoen, E. H. J., Fütterer, J. J., Barentsz, J. O., & Rovers, M. M. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.13.11046 · Cited by 470
Self-citationRosenkrantz, A. B., Verma, S., Choyke, P., Eberhardt, S. C., Eggener, S. E., Gaitonde, K., Haider, M. A., Margolis, D. J., Marks, L. S., Pinto, P., et al. (2016) · Journal of Urology · doi:10.1016/j.juro.2016.06.079 · Cited by 353
Lemaître, G., Martí, R., Freixenet, J., Vilanova, J. C., Walker, P. M., & Meriaudeau, F. (2015) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2015.02.009 · Cited by 348
Woo, S., Suh, C. H., Kim, S. Y., Cho, J. Y., & Kim, S. H. (2017) · European Urology · doi:10.1016/j.eururo.2017.01.042 · Cited by 308
Rundo, L., Han, C., Nagano, Y., Zhang, J., Hataya, R., Militello, C., Tangherloni, A., Nobile, M. S., Ferretti, C., Besozzi, D., et al. (2019) · Neurocomputing · doi:10.1016/j.neucom.2019.07.006 · Cited by 287
Rosenkrantz, A. B., Kim, S., Lim, R. P., Hindman, N., Deng, F.-M., Babb, J. S., & Taneja, S. S. (2013) · Radiology · doi:10.1148/radiol.13122233 · Cited by 267
Sunoqrot, M. R. S., Saha, A., Hosseinzadeh, M., Elschot, M., & Huisman, H. (2022) · European Radiology Experimental · doi:10.1186/s41747-022-00288-8 · Cited by 76
“Other complications include the presence of image artifacts [76] and that MR image acquisition is not standardized, although minimum requirements for PI-RADS reading exist [7].”
Self-citation
Metadata
- Authors
- Hoeks, C. M. A., Barentsz, J. O., Hambrock, T., Yakar, D., Somford, D. M., Heijmink, S. W. T. P. J., Scheenen, T. W. J., Vos, P. C., Huisman, H., van Oort, I. M., Witjes, J. A., Heerschap, A., & Fütterer, J. J.
- Venue
- Radiology
- Published
- 2011-10
- Volume
- 261
- Issue
- 1
- Pages
- 46-66
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2098226918
- Cited by
- 677
- References
- 59
- FWCI
- 46.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.