The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
CT Dose Index and Patient Dose: They Are Not the Same Thing
Open accessAbstract
Estimates of individual patient risk, and epidemiologic studies assessing potential late effects, must use patient size–specific dose estimates—they cannot use only scanner output (volume CT dose index or dose-length product).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smith-Bindman, R. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.427 · Cited by 2,464
CT Dose Reduction and Dose Management Tools: Overview of Available Options
McCollough, C. H., Bruesewitz, M. R., & Kofler, J. M. (2006) · RadioGraphics · doi:10.1148/rg.262055138 · Cited by 768
Self-citationTechniques and Applications of Automatic Tube Current Modulation for CT
Kalra, M. K., Maher, M. M., Toth, T. L., Schmidt, B., Westerman, B. L., Morgan, H. T., & Saini, S. (2004) · Radiology · doi:10.1148/radiol.2333031150 · Cited by 725
Specific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn
Cristy, M., & Eckerman, K. F. (1987) · doi:10.2172/6202949 · Cited by 692
Jakobs, T. F., Becker, C. R., Ohnesorge, B., Flohr, T., Suess, C., Schoepf, U. J., & Reiser, M. F. (2002) · European Radiology · doi:10.1007/s00330-001-1278-x · Cited by 615
AAPM/RSNA Physics Tutorial for Residents: Topics in CT: Radiation Dose in CT
McNitt-Gray, M. F. (2002) · RadioGraphics · doi:10.1148/rg.226025128 · Cited by 612
Self-citationChristner, J. A., Kofler, J. M., & McCollough, C. H. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.3462 · Cited by 492
Self-citationA method for describing the doses delivered by transmission x-ray computed tomography
Shope, T. B., Gagne, R. M., & Johnson, G. C. (1981) · Medical Physics · doi:10.1118/1.594995 · Cited by 435
Boone, J. M. (2007) · Medical Physics · doi:10.1118/1.2713240 · Cited by 417
Self-citationPerformance evaluation of a multi-slice CT system
McCollough, C. H., & Zink, F. E. (1999) · Medical Physics · doi:10.1118/1.598777 · Cited by 386
Self-citation
Cited by
Christner, J. A., Kofler, J. M., & McCollough, C. H. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.3462 · Cited by 492
Self-citationU.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations
Kanal, K. M., Butler, P. F., Sengupta, D., Bhargavan-Chatfield, M., Coombs, L. P., & Morin, R. L. (2017) · Radiology · doi:10.1148/radiol.2017161911 · Cited by 395
Establishment of CT diagnostic reference levels in Ireland
Foley, S. J., McEntee, M. F., & Rainford, L. A. (2012) · The British Journal of Radiology · doi:10.1259/bjr/15839549 · Cited by 186
Brady, S. L., & Kaufman, R. A. (2012) · Radiology · doi:10.1148/radiol.12120131 · Cited by 137
Diagnostic reference levels from the ACR CT accreditation program
McCollough, C., Branham, T., Herlihy, V., Bhargavan, M., Robbins, L., Bush, K., McNitt-Gray, M., Payne, J. T., Ruckdeschel, T., Pfeiffer, D., et al. (2011) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2011.03.014 · Cited by 98
Self-citation(2020) · Europe PMC (PubMed Central) · doi:10.22038/aojnmb.2019.40863.1276 · Cited by 18
Noferini, L., Fulcheri, C., Taddeucci, A., Bartolini, M., & Gori, C. (2014) · Radiological Physics and Technology · doi:10.1007/s12194-014-0265-2 · Cited by 16
Clerkin, C., Brennan, S., & Mullaney, L. M. (2018) · Reports of Practical Oncology & Radiotherapy · doi:10.1016/j.rpor.2018.07.012 · Cited by 14
Diagnostic Reference Levels of Radiographic and CT Examinations in Jordan: A Systematic Review
Alzyoud, K., Al-Murshedi, S., & England, A. (2024) · Health Physics · doi:10.1097/hp.0000000000001778 · Cited by 6
Metadata
- Authors
- McCollough, C. H., Leng, S., Yu, L., Cody, D. D., Boone, J. M., & McNitt-Gray, M. F.
- Venue
- Radiology
- Published
- 2011-05
- Volume
- 259
- Issue
- 2
- Pages
- 311-316
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2108836250
- Cited by
- 463
- References
- 32
- FWCI
- 28.04
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.