CoChat

Multiple Sclerosis: Validation of MR Imaging for Quantification and Detection of Iron

Walsh, Andrew J., Lebel, R. Marc, Eissa, Amir, Blevins, Gregg, Catz, Ingrid, Lu, Jian-Qiang, Resch, Lothar, Johnson, Edward S., Emery, Derek J., Warren, Kenneth G., Wilman, Alan H. · 2013 · Radiology
Cited by 92

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

PURPOSE: To investigate the relationship between iron staining and magnetic resonance (MR) imaging measurements in postmortem subjects with multiple sclerosis (MS). MATERIALS AND METHODS: Institutional ethical approval was obtained, and informed consent was obtained from the subjects and/or their families. Four MR imaging methods based on transverse relaxation (T2 weighting, R2 mapping, and R2* mapping) and phase imaging were performed by using a 4.7-T system in three in situ postmortem patients with MS less than 28 hours after death and in one in vivo patient 1 year before death. Iron staining with the Perls iron reaction was performed after brain extraction. Region-of-interest measurements from six subcortical gray matter structures were obtained from MR imaging and then correlated with corresponding locations on photographs of iron-stained pathologic slices by using a separate linear least-squares regression in each subject. Iron status of white matter lesions, as determined by staining, was compared with appearance on MR images. RESULTS: R2* mapping had the highest intrasubject correlations with iron in subcortical gray matter (R(2) = 0.857, 0.628, and 0.685; all P < .001), while R2 mapping (R(2) = 0.807, 0.615, 0.628, and 0.489; P < .001 and P = .001, .034, and .001, respectively), phase imaging (R(2) = 0.672, 0.441, 0.596, 0.548; all P ≤ .001), and T2-weighted imaging (R(2) = 0.463, 0.582, 0.650, and 0.551; all P < .001) had lower but still strong correlations. Within lesions, hypointense areas on phase images did not always represent iron. A hyperintense rim surrounding lesions on R2* maps was only present with iron staining, yet not all iron-staining lesions had R2* rim hyperintensity. CONCLUSION: All four MR imaging methods had significant linear correlations with iron and could potentially be used to determine iron status of subcortical gray matter structures in MS, with R2* mapping being preferred. A reliable method of determining iron status within MS lesions was not established.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.12120863

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Walsh, A. J., Lebel, R. M., Eissa, A., Blevins, G., Catz, I., Lu, J.-Q., Resch, L., Johnson, E. S., Emery, D. J., Warren, K. G., & Wilman, A. H.
Venue
Radiology
Published
2013-05
Volume
267
Issue
2
Pages
531-542
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2115140807
Cited by
92
References
9
FWCI
9.74
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.