Intracranial Mass Lesions: Dynamic Contrast-enhanced Susceptibility-weighted Echo-planar Perfusion MR Imaging
The DOI matches its Crossref record; 64 of the 64 references it cites were found in a registry or an index.
Abstract
Dynamic contrast agent-enhanced perfusion magnetic resonance (MR) imaging provides physiologic information that complements the anatomic information available with conventional MR imaging. Analysis of dynamic data from perfusion MR imaging, based on tracer kinetic theory, yields quantitative estimates of cerebral blood volume that reflect the underlying microvasculature and angiogenesis. Perfusion MR imaging is a fast and robust imaging technique that is increasingly used as a research tool to help evaluate and understand intracranial disease processes and as a clinical tool to help diagnose, manage, and understand intracranial mass lesions. With the increasing number of applications of perfusion MR imaging, it is important to understand the principles underlying the technique. In this review, the essential underlying physics and methods of dynamic contrast-enhanced susceptibility-weighted echo-planar perfusion MR imaging are described. The clinical applications of cerebral blood volume maps obtained with perfusion MR imaging in the differential diagnosis of intracranial mass lesions, as well as the pitfalls and limitations of the technique, are discussed. Emphasis is on the clinical role of perfusion MR imaging in providing insight into the underlying pathophysiology of cerebral microcirculation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Endostatin: an endogenous inhibitor of angiogenesis and tumor growth
O'Reilly, M. S., Boehm, T., Shing, Y., Fukai, N., Vasios, G., Lane, W. S., Flynn, E., Birkhead, J. R., Olsen, B. R., & Folkman, J. (1997) · Cell · doi:10.1016/s0092-8674(00)81848-6 · Cited by 4,486
Clinical Applications of Research on Angiogenesis
Folkman, J. (1995) · New England Journal of Medicine · doi:10.1056/nejm199512283332608 · Cited by 2,264
Multi-planar image formation using NMR spin echoes
Mansfield, P. (1977) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/10/3/004 · Cited by 1,813
Detre, J. A., Leigh, J. S., Williams, D. S., & Koretsky, A. P. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910230106 · Cited by 1,571
Modeling tracer kinetics in dynamic Gd‐DTPA MR imaging
Tofts, P. S. (1997) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880070113 · Cited by 1,478
Tofts, P. S., & Kermode, A. G. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910170208 · Cited by 1,456
Perfusion imaging with NMR contrast agents
Rosen, B. R., Belliveau, J. W., Vevea, J. M., & Brady, T. J. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140211 · Cited by 1,151
Kim, S. (1995) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910340303 · Cited by 1,001
Cerebral blood volume maps of gliomas: comparison with tumor grade and histologic findings.
Aronen, H. J., Gazit, I. E., Louis, D. N., Buchbinder, B. R., Pardo, F. S., Weisskoff, R. M., Harsh, G. R., Cosgrove, G. R., Halpern, E. F., & Hochberg, F. H. (1994) · Radiology · doi:10.1148/radiology.191.1.8134596 · Cited by 908
Østergaard, L., Sorensen, A. G., Kwong, K. K., Weisskoff, R. M., Gyldensted, C., & Rosen, B. R. (1996) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910360511 · Cited by 810
Cited by
Imaging of angiogenesis: from microscope to clinic
McDonald, D. M., & Choyke, P. L. (2003) · Nature Medicine · doi:10.1038/nm0603-713 · Cited by 1,016
Principles, Techniques, and Applications of T2*-based MR Imaging and Its Special Applications
Chavhan, G. B., Babyn, P. S., Thomas, B., Shroff, M. M., & Haacke, E. M. (2009) · RadioGraphics · doi:10.1148/rg.295095034 · Cited by 740
Comparative Overview of Brain Perfusion Imaging Techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J.-F., et al. (2005) · Stroke · doi:10.1161/01.str.0000177884.72657.8b · Cited by 592
Patterns of Contrast Enhancement in the Brain and Meninges
Smirniotopoulos, J. G., Murphy, F. M., Rushing, E. J., Rees, J. H., & Schroeder, J. W. (2007) · RadioGraphics · doi:10.1148/rg.272065155 · Cited by 502
Weinstein, J. S., Varallyay, C. G., Dosa, E., Gahramanov, S., Hamilton, B., Rooney, W. D., Muldoon, L. L., & Neuwelt, E. A. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2009.192 · Cited by 500
“In CNS malignancies, CBV has been one of the most commonly used parameters to estimate microvascular density (Cha et al, 2002).”
MethodClinical applications of neuroimaging with susceptibility‐weighted imaging
Sehgal, V., Delproposto, Z., Haacke, E. M., Tong, K. A., Wycliffe, N., Kido, D. K., Xu, Y., Neelavalli, J., Haddar, D., & Reichenbach, J. R. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20404 · Cited by 427
Provenzale, J. M., Mukundan, S., & Barboriak, D. P. (2006) · Radiology · doi:10.1148/radiol.2393042031 · Cited by 402
Perfusion MRI: The Five Most Frequently Asked Technical Questions
Essig, M., Shiroishi, M. S., Nguyen, T. B., Saake, M., Provenzale, J. M., Enterline, D., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9543 · Cited by 366
Perfusion MRI: The Five Most Frequently Asked Clinical Questions
Essig, M., Nguyen, T. B., Shiroishi, M. S., Saake, M., Provenzale, J. M., Enterline, D. S., Anzalone, N., Dörfler, A., Rovira, À., Wintermark, M., et al. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.9544 · Cited by 344
Paulson, E. S., & Schmainda, K. M. (2008) · Radiology · doi:10.1148/radiol.2492071659 · Cited by 327
Sourbron, S., Ingrisch, M., Siefert, A., Reiser, M., & Herrmann, K. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22005 · Cited by 276
Advanced MR Imaging Techniques in the Diagnosis of Intraaxial Brain Tumors in Adults
Al-Okaili, R. N., Krejza, J., Wang, S., Woo, J. H., & Melhem, E. R. (2006) · RadioGraphics · doi:10.1148/rg.26si065513 · Cited by 276
Diagnostic performance of spectroscopic and perfusion MRI for distinction of brain tumors
Weber, M. A., Zoubaa, S., Schlieter, M., Jüttler, E., Huttner, H. B., Geletneky, K., Ittrich, C., Lichy, M. P., Kroll, A., Debus, J., et al. (2006) · Neurology · doi:10.1212/01.wnl.0000219767.49705.9c · Cited by 268
Perfusion and diffusion MR imaging in enhancing malignant cerebral tumors
Calli, C., Kitis, O., Yunten, N., Yurtseven, T., Islekel, S., & Akalin, T. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2005.12.032 · Cited by 263
Anderson, S. A., Glod, J., Arbab, A. S., Noel, M., Ashari, P., Fine, H. A., & Frank, J. A. (2005) · Blood · doi:10.1182/blood-2004-06-2222 · Cited by 254
Narayana, A., Kelly, P., Golfinos, J., Parker, E., Johnson, G., Knopp, E., Zagzag, D., Fischer, I., Raza, S., Medabalmi, P., et al. (2009) · Journal of Neurosurgery · doi:10.3171/2008.4.17492 · Cited by 243
Self-citationDanchaivijitr, N., Waldman, A. D., Tozer, D. J., Benton, C. E., Brasil Caseiras, G., Tofts, P. S., Rees, J. H., & Jäger, H. R. (2008) · Radiology · doi:10.1148/radiol.2471062089 · Cited by 238
Jain, R., Poisson, L. M., Gutman, D., Scarpace, L., Hwang, S. N., Holder, C. A., Wintermark, M., Rao, A., Colen, R. R., Kirby, J., et al. (2014) · Radiology · doi:10.1148/radiol.14131691 · Cited by 234
T1 and T2 Dual-Mode MRI Contrast Agent for Enhancing Accuracy by Engineered Nanomaterials
Shin, T.-H., Choi, J.-S., Yun, S., Kim, I.-S., Song, H.-T., Kim, Y., Park, K. I., & Cheon, J. (2014) · ACS Nano · doi:10.1021/nn405977t · Cited by 209
Mountz, J., Ahmed, R., Oborski, M., Lieberman, F., & Hwang, M. (2014) · Cancer Management and Research · doi:10.2147/cmar.s54726 · Cited by 208
Boxerman, J. L., Quarles, C. C., Hu, L. S., Erickson, B. J., Gerstner, E. R., Smits, M., Kaufmann, T. J., Barboriak, D. P., Huang, R. H., Wick, W., et al. (2020) · Neuro-Oncology · doi:10.1093/neuonc/noaa141 · Cited by 206
“>20ms) can reduce T1 contamination due to GBCA extravasation.(44) However, some parameter combinations may also reduce the SNR of the computed rCBV maps,(67) and the goal is to minimize leakage effects while maintaining SNR.”
Prager, A. J., Martinez, N., Beal, K., Omuro, A., Zhang, Z., & Young, R. J. (2015) · American Journal of Neuroradiology · doi:10.3174/ajnr.a4218 · Cited by 193
Imaging and diagnostic advances for intracranial meningiomas
Huang, R. Y., Bi, W. L., Griffith, B., Kaufmann, T. J., la Fougère, C., Schmidt, N. O., Tonn, J. C., Vogelbaum, M. A., Wen, P. Y., Aldape, K., et al. (2019) · Neuro-Oncology · doi:10.1093/neuonc/noy143 · Cited by 189
Comparative overview of brain perfusion imaging techniques
Wintermark, M., Sesay, M., Barbier, E., Borbély, K., Dillon, W. P., Eastwood, J. D., Glenn, T. C., Grandin, C. B., Pedraza, S., Soustiel, J. F., et al. (2005) · Journal of Neuroradiology · doi:10.1016/s0150-9861(05)83159-1 · Cited by 185
Dural masses: meningiomas and their mimics
Lyndon, D., Lansley, J. A., Evanson, J., & Krishnan, A. S. (2019) · Insights into Imaging · doi:10.1186/s13244-019-0697-7 · Cited by 166
“Furthermore, extra-axial tumours in general can be differentiated from intra-axial tumours due to the tendency of the former’s time-intensity curve to not return to baseline during the first pass [17].”
BackgroundDiagnostic challenges in meningioma
Nowosielski, M., Galldiks, N., Iglseder, S., Kickingereder, P., von Deimling, A., Bendszus, M., Wick, W., & Sahm, F. (2017) · Neuro-Oncology · doi:10.1093/neuonc/nox101 · Cited by 165
Metadata
- Authors
- Cha, S., Knopp, E. A., Johnson, G., Wetzel, S. G., Litt, A. W., & Zagzag, D.
- Venue
- Radiology
- Published
- 2002-04
- Volume
- 223
- Issue
- 1
- Pages
- 11-29
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2153428956
- Cited by
- 525
- References
- 64
- FWCI
- 16.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.