Performance Benchmarks for Screening Mammography
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Abstract
PURPOSE: To retrospectively evaluate the range of performance outcomes of the radiologist in an audit of screening mammography by using a representative sample of U.S. radiologists to allow development of performance benchmarks for screening mammography. MATERIALS AND METHODS: Institutional review board approval was obtained, and study was HIPAA compliant. Informed consent was or was not obtained according to institutional review board guidelines. Data from 188 mammographic facilities and 807 radiologists obtained between 1996 and 2002 were analyzed from six registries from the Breast Cancer Surveillance Consortium (BCSC). Contributed data included demographic information, clinical findings, mammographic interpretation, and biopsy results. Measurements calculated were positive predictive values (PPVs) from screening mammography (PPV(1)), biopsy recommendation (PPV(2)), biopsy performed (PPV(3)), recall rate, cancer detection rate, mean cancer size, and cancer stage. Radiologist performance data are presented as 50th (median), 10th, 25th, 75th, and 90th percentiles and as graphic presentations by using smoothed curves. RESULTS: There were 2 580 151 screening mammographic studies from 1 117 390 women (age range, <30 to >/=80 years). The respective means and ranges of performance outcomes for the middle 50% of radiologists were as follows: recall rate, 9.8% and 6.4%-13.3%; PPV(1), 4.8% and 3.4%-6.2%; and PPV(2), 24.6% and 18.8%-32.0%. Mean cancer detection rate was 4.7 per 1000, and the median [corrected] mean size of invasive cancers was 13 mm. The range of performance outcomes for the middle 80% of radiologists also was presented. CONCLUSION: Community screening mammographic performance measurements of cancer outcomes for the majority of radiologists in the BCSC surpass performance recommendations. Recall rate for almost half of radiologists, however, is higher than the recommended rate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
UPDATE OF THE SWEDISH TWO-COUNTY PROGRAM OF MAMMOGRAPHIC SCREENING FOR BREAST CANCER
Tabàr, L., Fagerberg, G., Duffy, S. W., Day, N. E., Gad, A., & Gröntoft, O. (1992) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(22)02494-0 · Cited by 731
Effect of Age, Breast Density, and Family History on the Sensitivity of First Screening Mammography
Kerlikowske, K. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03540010035027 · Cited by 624
Self-citationVariability in Radiologists' Interpretations of Mammograms
Elmore, J. G., Wells, C. K., Lee, C. H., Howard, D. H., & Feinstein, A. R. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312206 · Cited by 601
Positive Predictive Value of Screening Mammography by Age and Family History of Breast Cancer
Kerlikowske, K. (1993) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1993.03510200050031 · Cited by 364
Self-citationBeam, C. A. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.1996.00440020119016 · Cited by 337
Comparison of Screening Mammography in the United States and the United Kingdom
Smith-Bindman, R. (2003) · JAMA · doi:10.1001/jama.290.16.2129 · Cited by 314
Kerlikowske, K., Grady, D., Barclay, J., Ernster, V., Frankel, S. D., Ominsky, S. H., & Sickles, E. A. (1998) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/90.23.1801 · Cited by 298
Self-citationPerformance Parameters for Screening and Diagnostic Mammography: Specialist and General Radiologists
Sickles, E. A., Wolverton, D. E., & Dee, K. E. (2002) · Radiology · doi:10.1148/radiol.2243011482 · Cited by 249
Self-citationKerlikowske, K., Carney, P. A., Geller, B., Mandelson, M. T., Taplin, S. H., Malvin, K., Ernster, V., Urban, N., Cutter, G., Rosenberg, R., et al. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-11-200012050-00009 · Cited by 233
Self-citationAccuracy of Screening Mammography Interpretation by Characteristics of Radiologists
Barlow, W. E., Chi, C., Carney, P. A., Taplin, S. H., D'Orsi, C., Cutter, G., Hendrick, R. E., & Elmore, J. G. (2004) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djh333 · Cited by 216
Self-citation
Cited by
Berg, W. A. (2008) · JAMA · doi:10.1001/jama.299.18.2151 · Cited by 1,526
Screening for Breast Cancer: An Update for the U.S. Preventive Services Task Force
Nelson, H. D., Tyne, K., Naik, A., Bougatsos, C., Chan, B. K., & Humphrey, L. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-10-200911170-00009 · Cited by 1,248
Breast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography
Friedewald, S. M., Rafferty, E. A., Rose, S. L., Durand, M. A., Plecha, D. M., Greenberg, J. S., Hayes, M. K., Copit, D. S., Carlson, K. L., Cink, T. M., et al. (2014) · JAMA · doi:10.1001/jama.2014.6095 · Cited by 851
Lehman, C. D., Arao, R. F., Sprague, B. L., Lee, J. M., Buist, D. S. M., Kerlikowske, K., Henderson, L. M., Onega, T., Tosteson, A. N. A., Rauscher, G. H., et al. (2017) · Radiology · doi:10.1148/radiol.2016161174 · Cited by 665
Self-citationMandelblatt, J. S., Cronin, K. A., Bailey, S., Berry, D. A., de Koning, H. J., Draisma, G., Huang, H., Lee, S. J., Munsell, M., Plevritis, S. K., et al. (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-10-200911170-00010 · Cited by 605
Kuhl, C., Weigel, S., Schrading, S., Arand, B., Bieling, H., König, R., Tombach, B., Leutner, C., Rieber-Brambs, A., Nordhoff, D., et al. (2010) · Journal of Clinical Oncology · doi:10.1200/jco.2009.23.0839 · Cited by 501
Lotter, W., Diab, A. R., Haslam, B., Kim, J. G., Grisot, G., Wu, E., Wu, K., Onieva, J. O., Boyer, Y., Boxerman, J. L., et al. (2021) · Nature Medicine · doi:10.1038/s41591-020-01174-9 · Cited by 423
Digital Breast Tomosynthesis: Observer Performance Study
Gur, D., Abrams, G. S., Chough, D. M., Ganott, M. A., Hakim, C. M., Perrin, R. L., Rathfon, G. Y., Sumkin, J. H., Zuley, M. L., & Bandos, A. I. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.2031 · Cited by 363
Radiation Doses and Cancer Risks from Breast Imaging Studies
Hendrick, R. E. (2010) · Radiology · doi:10.1148/radiol.10100570 · Cited by 360
Mandelblatt, J. S., Stout, N. K., Schechter, C. B., van den Broek, J. J., Miglioretti, D. L., Krapcho, M., Trentham-Dietz, A., Munoz, D., Lee, S. J., Berry, D. A., et al. (2016) · Annals of Internal Medicine · doi:10.7326/m15-1536 · Cited by 281
Self-citationElmore, J. G., Jackson, S. L., Abraham, L., Miglioretti, D. L., Carney, P. A., Geller, B. M., Yankaskas, B. C., Kerlikowske, K., Onega, T., Rosenberg, R. D., et al. (2009) · Radiology · doi:10.1148/radiol.2533082308 · Cited by 263
Self-citationMicrobubble-mediated ultrasound therapy: a review of its potential in cancer treatment
Ibsen, S., Schutt, & Esener (2013) · Drug Design, Development and Therapy · doi:10.2147/dddt.s31564 · Cited by 219
“108 Reducing this false-positive rate requires additional knowledge about the biochemistry of the observed mass and looking for strong indicators of tumor-associated conditions and the hallmarks of malignancy including hypoxia and angiogenesis.”
Sprague, B. L., Conant, E. F., Onega, T., Garcia, M. P., Beaber, E. F., Herschorn, S. D., Lehman, C. D., Tosteson, A. N. A., Lacson, R., Schnall, M. D., et al. (2016) · Annals of Internal Medicine · doi:10.7326/m15-2934 · Cited by 202
Self-citationEffectiveness of Computer-Aided Detection in Community Mammography Practice
Fenton, J. J., Abraham, L., Taplin, S. H., Geller, B. M., Carney, P. A., D'Orsi, C., Elmore, J. G., Barlow, W. E., & for the Breast Cancer Surveillance Consortium (2011) · JNCI Journal of the National Cancer Institute · doi:10.1093/jnci/djr206 · Cited by 168
“CAD is now applied to the large majority of screening mammograms in the United States with annual direct Medicare costs exceeding $30 million (2).”
BackgroundSelf-citationNelson, H. D., Tyne, K., Naik, A. M., Bougatsos, C., Chan, B. K. S., Nygren, P., & Humphrey, L. L. (2009) · PubMed Central · doi:10.1059/0003-4819-151-10-200911170-00009 · Cited by 164
Metadata
- Authors
- Rosenberg, R. D., Yankaskas, B. C., Abraham, L. A., Sickles, E. A., Lehman, C. D., Geller, B. M., Carney, P. A., Kerlikowske, K., Buist, D. S. M., Weaver, D. L., Barlow, W. E., & Ballard-Barbash, R.
- Venue
- Radiology
- Published
- 2006-10
- Volume
- 241
- Issue
- 1
- Pages
- 55-66
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2361503148
- Cited by
- 336
- References
- 20
- FWCI
- 11.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.