The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Diagnostic Performance of Multidetector CT Angiography for Assessment of Coronary Artery Disease: Meta-analysis
Abstract
PURPOSE: To review the literature on the diagnostic performance of multidetector computed tomographic (CT) angiography for assessment of symptomatic coronary artery disease, with conventional coronary angiography as the reference standard. MATERIALS AND METHODS: A PubMed and manual search of the literature published between January 1998 and May 2006 on use of multidetector CT angiography compared with coronary angiography in patients with symptomatic coronary artery disease was performed. Summary estimates of diagnostic odds ratio, sensitivity, and specificity were calculated. Random-effects models were used to compare the diagnostic performance of four-, 16-, and 64-detector CT angiographic units, and the proportion of nonassessable coronary arterial segments was evaluated. RESULTS: Fifty-four studies were included in the meta-analysis: 22 studies with four-detector CT angiography, 26 with 16-detector CT angiography, and six with 64-detector CT angiography. The pooled sensitivity and specificity for detecting a greater than 50% stenosis per segment were 0.93 (95% confidence interval [CI]: 0.88, 0.97) and 0.96 (95% CI: 0.96, 0.97) for 64-detector CT angiography, 0.83 (95% CI: 0.76, 0.90) and 0.96 (95% CI: 0.95, 0.97) for 16-detector CT angiography, and 0.84 (95% CI: 0.81, 0.88) and 0.93 (95% CI: 0.91, 0.95) for four-detector CT angiography, respectively. Results of regression analysis indicated that the diagnostic performance significantly improved with the newer generations of multidetector CT scanners (64- and 16-detector vs four-detector units), adjusted for exclusion of nonassessable segments, and contrast agent concentration used (P < .05). Simultaneously, the nonassessable proportion of segments significantly decreased with the newer generations of multidetector CT scanners, adjusted for heart rate, prevalence of significant disease, and mean age. CONCLUSION: With the newer generations of multidetector CT scanners, the diagnostic performance for the assessment of coronary artery disease has significantly improved, and the proportion of nonassessable segments has decreased.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
Quantifying heterogeneity in a meta‐analysis
Higgins, J. P. T., & Thompson, S. G. (2002) · Statistics in Medicine · doi:10.1002/sim.1186 · Cited by 36,763
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Investigating and dealing with publication and other biases in meta-analysis
Sterne, J. A. C., Egger, M., & Smith, G. D. (2001) · BMJ · doi:10.1136/bmj.323.7304.101 · Cited by 2,225
Diagnostic Accuracy of Noninvasive Coronary Angiography Using 64-Slice Spiral Computed Tomography
Raff, G. L., Gallagher, M. J., O’Neill, W. W., & Goldstein, J. A. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.05.056 · Cited by 1,472
Moses, L. E., Shapiro, D., & Littenberg, B. (1993) · Statistics in Medicine · doi:10.1002/sim.4780121403 · Cited by 1,405
Scanlon, P. J., Faxon, D. P., Audet, A.-M., Carabello, B., Dehmer, G. J., Eagle, K. A., Legako, R. D., Leon, D. F., Murray, J. A., Nissen, S. E., et al. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00126-6 · Cited by 1,123
Quantification of Obstructive and Nonobstructive Coronary Lesions by 64-Slice Computed Tomography
Leber, A. W., Knez, A., von Ziegler, F., Becker, A., Nikolaou, K., Paul, S., Wintersperger, B., Reiser, M., Becker, C. R., Steinbeck, G., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.071 · Cited by 1,109
Mollet, N. R., Cademartiri, F., van Mieghem, C. A. G., Runza, G., McFadden, E. P., Baks, T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2005) · Circulation · doi:10.1161/circulationaha.105.533471 · Cited by 1,018
Systematic Review: Why sources of heterogeneity in meta-analysis should be investigated
Thompson, S. G. (1994) · BMJ · doi:10.1136/bmj.309.6965.1351 · Cited by 1,017
Accuracy of MSCT coronary angiography with 64-slice technology: first experience
Leschka, S., Alkadhi, H., Plass, A., Desbiolles, L., Grünenfelder, J., Marincek, B., & Wildermuth, S. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi261 · Cited by 960
Conducting systematic reviews of diagnostic studies: didactic guidelines
Devillé, W. L., Buntinx, F., Bouter, L. M., Montori, V. M., de Vet, H. C., van der Windt, D. A., & Bezemer, P. D. (2002) · BMC Medical Research Methodology · doi:10.1186/1471-2288-2-9 · Cited by 960
Nieman, K., Cademartiri, F., Lemos, P. A., Raaijmakers, R., Pattynama, P. M. T., & de Feyter, P. J. (2002) · Circulation · doi:10.1161/01.cir.0000037222.58317.3d · Cited by 956
Ropers, D., Baum, U., Pohle, K., Anders, K., Ulzheimer, S., Ohnesorge, B., Schlundt, C., Bautz, W., Daniel, W. G., & Achenbach, S. (2003) · Circulation · doi:10.1161/01.cir.0000055738.31551.a9 · Cited by 930
A random‐effects regression model for meta‐analysis
Berkey, C. S., Hoaglin, D. C., Mosteller, F., & Colditz, G. A. (1995) · Statistics in Medicine · doi:10.1002/sim.4780140406 · Cited by 879
Guidelines for Meta-analyses Evaluating Diagnostic Tests
Irwig, L., Tosteson, A. N. A., Gatsonis, C., Lau, J., Colditz, G., Chalmers, T. C., & Mosteller, F. (1994) · Annals of Internal Medicine · doi:10.7326/0003-4819-120-8-199404150-00008 · Cited by 753
Achenbach, S., Giesler, T., Ropers, D., Ulzheimer, S., Derlien, H., Schulte, C., Wenkel, E., Moshage, W., Bautz, W., Daniel, W. G., et al. (2001) · Circulation · doi:10.1161/01.cir.103.21.2535 · Cited by 667
Noninvasive Coronary Angiography With Multislice Computed Tomography
Hoffmann, M. H. K. (2005) · JAMA · doi:10.1001/jama.293.20.2471 · Cited by 507
Estimating Diagnostic Accuracy from Multiple Conflicting Reports: A New Meta-analytic Method
Littenberg, B., & Moses, L. E. (1993) · Medical Decision Making · doi:10.1177/0272989x9301300408 · Cited by 434
Hoffmann, U., Moselewski, F., Cury, R. C., Ferencik, M., Jang, I.-K., Diaz, L. J., Abbara, S., Brady, T. J., & Achenbach, S. (2004) · Circulation · doi:10.1161/01.cir.0000145614.07427.9f · Cited by 413
Multislice spiral computed tomography coronary angiography in patients with stable angina pectoris
Mollet, N. R., Cademartiri, F., Nieman, K., Saia, F., Lemos, P. A., McFadden, E. P., Pattynama, P. M. T., Serruys, P. W., Krestin, G. P., & de Feyter, P. J. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.03.032 · Cited by 406
Halligan, S., Altman, D. G., Taylor, S. A., Mallett, S., Deeks, J. J., Bartram, C. I., & Atkin, W. (2005) · Radiology · doi:10.1148/radiol.2373050176 · Cited by 382
Ringqvist, I., Fisher, L. D., Mock, M., Davis, K. B., Wedel, H., Chaitman, B. R., Passamani, E., Russell, R. O., Alderman, E. L., Kouchoukas, N. T., et al. (1983) · Journal of Clinical Investigation · doi:10.1172/jci110941 · Cited by 320
Kuettner, A., Trabold, T., Schroeder, S., Feyer, A., Beck, T., Brueckner, A., Heuschmid, M., Burgstahler, C., Kopp, A. F., & Claussen, C. D. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.05.079 · Cited by 280
Gavaghan, D. J., Moore, A. R., & McQuay, H. J. (2000) · Pain · doi:10.1016/s0304-3959(99)00302-4 · Cited by 279
Accuracy of thin-slice computed tomography in the detection of coronary stenoses
MARTUSCELLI, E. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.03.024 · Cited by 259
Schuijf, J. D., Bax, J. J., Shaw, L. J., de Roos, A., Lamb, H. J., van der Wall, E. E., & Wijns, W. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.03.022 · Cited by 255
Self-citationKopp, A. (2002) · European Heart Journal · doi:10.1016/s0195-668x(02)93264-1 · Cited by 252
Leaman, D. M., Brower, R. W., Meester, G. T., Serruys, P., & van den Brand, M. (1981) · Circulation · doi:10.1161/01.cir.63.2.285 · Cited by 243
Kuettner, A., Kopp, A. F., Schroeder, S., Rieger, T., Brunn, J., Meisner, C., Heuschmid, M., Trabold, T., Burgstahler, C., Martensen, J., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.05.015 · Cited by 228
Techniques for the Detection of Coronary Atherosclerosis: Multi–detector Row CT Coronary Angiography
Vogl, T. J., Abolmaali, N. D., Diebold, T., Engelmann, K., Ay, M., Dogan, S., Wimmer-Greinecker, G., Moritz, A., & Herzog, C. (2002) · Radiology · doi:10.1148/radiol.2231010515 · Cited by 203
Achenbach, S., Ropers, D., Pohle, F.-K., Raaz, D., von Erffa, J., Yilmaz, A., Muschiol, G., & Daniel, W. G. (2005) · European Heart Journal · doi:10.1093/eurheartj/ehi326 · Cited by 172
Multidetector Computed Tomography for the Diagnosis of Coronary Artery Disease: A Systematic Review
Stein, P. D., Beemath, A., Kayali, F., Skaf, E., Sánchez, J., & Olson, R. E. (2006) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.06.071 · Cited by 164
Dodge, J. T., Brown, B. G., Bolson, E. L., & Dodge, H. T. (1988) · Circulation · doi:10.1161/01.cir.78.5.1167 · Cited by 159
Kefer, J., Coche, E., Legros, G., Pasquet, A., Grandin, C. B. G., BEERS, B. E. V., Vanoverschelde, J., & Gerber, B. L. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.03.057 · Cited by 144
Schuijf, J. D., Bax, J. J., Salm, L. P., Jukema, J. W., Lamb, H. J., van der Wall, E. E., & Roos, A. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.11.002 · Cited by 127
Highly accurate coronary angiography with submillimetre, 16 slice computed tomography
Morgan-Hughes, G. J., Roobottom, C. A., Owens, P. E., & Marshall, A. J. (2005) · Heart · doi:10.1136/hrt.2004.034892 · Cited by 96
Sato, Y., Matsumoto, N., Ichikawa, M., Kunimasa, T., Iida, K., Yoda, S., Takayama, T., Uchiyama, T., Saito, S., Nagao, K., et al. (2005) · Circulation Journal · doi:10.1253/circj.69.1047 · Cited by 92
Haberl, R., Tittus, J., Böhme, E., Czernik, A., Richartz, B. M., Buck, J., & STEINBIGLER, P. (2005) · American Heart Journal · doi:10.1016/j.ahj.2005.02.048 · Cited by 90
Leber, A. W., Knez, A., Becker, C. R., Becker, A., White, C. W., Thilo, C., Reiser, M. F., Haberl, R., & Steinbeck, G. (2003) · Heart · doi:10.1136/heart.89.6.633 · Cited by 87
Sato, Y., Matsumoto, N., Katô, M., Inoue, F., Horie, T., Kusama, J., Yoshimura, A., Imazeki, T., Fukui, T., Furuhashi, S., et al. (2003) · Circulation Journal · doi:10.1253/circj.67.401 · Cited by 79
Noninvasive Assessment of Coronary Plaque Burden Using Multislice Computed Tomography
Mollet, N. R., Cademartiri, F., Nieman, K., Saia, F., Lemos, P. A., McFadden, E. P., Serruys, P. W. J. C., Krestin, G. P., & de Feyter, P. J. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.01.043 · Cited by 77
Cardiac multidetector-row computed tomography in patients with unstable angina
Dirksen, M. S., Jukema, J. W., Bax, J. J., Lamb, H. J., Boersma, E. H., Tuinenburg, J. C., Geleijns, J., van der Wall, E. E., & Roos, A. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.10.010 · Cited by 73
Coronary Artery Stenoses: Detection with Calcium Scoring, CT Angiography, and Both Methods Combined
Lau, G. T., Ridley, L. J., Schieb, M. C., Brieger, D. B., Freedman, B., Wong, L. A., Lo, S. K., & Kritharides, L. (2005) · Radiology · doi:10.1148/radiol.2352031813 · Cited by 72
Schuijf, J. D., Bax, J. J., Jukema, J. W., Lamb, H. J., Vliegen, H. W., Salm, L. P., Roos, A., & van der Wall, E. E. (2004) · Diabetes Care · doi:10.2337/diacare.27.12.2905 · Cited by 62
Herzog, C., Britten, M. B., Balzer, J. O., Mack, M. G., Zangos, S., Ackermann, H., Schaechinger, V., Schaller, S., Flohr, T. G., & Vogl, T. J. (2004) · European Radiology · doi:10.1007/s00330-003-2197-9 · Cited by 55
Multislice Computed Tomographic Coronary Angiography: Experience in a UK Centre
Morgan-Hughes, G. J., Marshall, A. J., & Roobottom, C. A. (2003) · Clinical Radiology · doi:10.1016/s0009-9260(03)00051-5 · Cited by 36
Beck, T., Kuettner, A., Burgstahler, C., Br�ckner, A., Heuschmid, M., Herdeg, C., Kopp, A. F., Claussen, C. D., & Schroeder, S. (2004) · Medizinische Klinik - Intensivmedizin und Notfallmedizin · doi:10.1007/s00063-004-1095-5 · Cited by 4
Explaining heterogeneity in meta-analysis: a comparison of methods
Thompson, S. G., & Sharp, S. J. (1999) · Statistics in Medicine · doi:10.1002/(sici)1097-0258(19991030)18:20
Cited by
Diagnostic Accuracy of 64-Slice Computed Tomography Coronary Angiography
Meijboom, W. B., Meijs, M. F. L., Schuijf, J. D., Cramer, M. J., Mollet, N. R., van Mieghem, C. A. G., Nieman, K., van Werkhoven, J. M., Pundziute, G., Weustink, A. C., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.08.058 · Cited by 1,239
Self-citationKinoshita, M., Yokote, K., Arai, H., Iida, M., Ishigaki, Y., Ishibashi, S., Umemoto, S., Egusa, G., Ohmura, H., Okamura, T., et al. (2018) · Journal of Atherosclerosis and Thrombosis · doi:10.5551/jat.gl2017 · Cited by 813
Initial evaluation of coronary images from 320-detector row computed tomography
Rybicki, F. J., Otero, H. J., Steigner, M. L., Vorobiof, G., Nallamshetty, L., Mitsouras, D., Ersoy, H., Mather, R. T., Judy, P. F., Cai, T., et al. (2008) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-008-9308-2 · Cited by 563
Schroeder, S., Achenbach, S., Bengel, F., Burgstahler, C., Cademartiri, F., de Feyter, P., George, R., Kaufmann, P., Kopp, A. F., Knuuti, J., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehm544 · Cited by 554
Bluemke, D. A., Achenbach, S., Budoff, M., Gerber, T. C., Gersh, B., Hillis, L. D., Hundley, W. G., Manning, W. J., Printz, B. F., Stuber, M., et al. (2008) · Circulation · doi:10.1161/circulationaha.108.189695 · Cited by 461
Metadata
- Authors
- Vanhoenacker, P. K., Heijenbrok-Kal, M. H., Van Heste, R., Decramer, I., Van Hoe, L. R., Wijns, W., & Hunink, M. G. M.
- Venue
- Radiology
- Published
- 2007-08
- Volume
- 244
- Issue
- 2
- Pages
- 419-428
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2113651653
- Cited by
- 442
- References
- 53
- FWCI
- 33.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.