Free-response methodology: alternate analysis and a new observer-performance experiment.
The DOI matches its Crossref record.
Abstract
The authors review the recently introduced method for analyzing free-response receiver operating characteristic (FROC) observer-performance experiments. These experiments allow multiple abnormalities and observer responses per image and require correct localization for true-positive events. A fundamental plot, the alternative FROC (AFROC), is emphasized, the area under which is a natural index of performance for measuring FROC observer performance. The authors show that it is possible to analyze free-response data in more general ways. The first method, AFROC analysis, involves scoring FROC images in a different way. The second method involves a new observer-performance experiment, the free-response forced error (FFE) experiment. FROC and AFROC analysis was applied to several FROC data sets, and simultaneous FROC-AFROC-FFE experiments were performed with several radiologist observers to test the three methods. The methods were found to be in good agreement with one another.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
SMITH, S., & NICHOLS, T. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.03.061 · Cited by 5,250
Computer-aided detection and classification of microcalcifications in mammograms: a survey
Cheng, H. D., Cai, X., Chen, X., Hu, L., & Lou, X. (2003) · Pattern Recognition · doi:10.1016/s0031-3203(03)00192-4 · Cited by 563
Approaches for automated detection and classification of masses in mammograms
Cheng, H. D., Shi, X. J., Min, R., Hu, L. M., Cai, X. P., & Du, H. N. (2006) · Pattern Recognition · doi:10.1016/j.patcog.2005.07.006 · Cited by 538
Niemeijer, M., van Ginneken, B., Cree, M. J., Mizutani, A., Quellec, G., Sanchez, C. I., Zhang, B., Hornero, R., Lamard, M., Muramatsu, C., et al. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2033909 · Cited by 516
Raffelt, D. A., Smith, R. E., Ridgway, G. R., Tournier, J.-D., Vaughan, D. N., Rose, S., Henderson, R., & Connelly, A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.05.039 · Cited by 386
Observer studies involving detection and localization: Modeling, analysis, and validation
Chakraborty, D. P., & Berbaum, K. S. (2004) · Medical Physics · doi:10.1118/1.1769352 · Cited by 351
Self-citationCurrent perspectives in medical image perception
Krupinski, E. A. (2010) · Attention, Perception & Psychophysics · doi:10.3758/app.72.5.1205 · Cited by 343
Obuchowski (2005) · doi:10.2214/ajr.184.2.01840364 · Cited by 321
Kim, S. H., Kim, S. H., Lee, J., Kim, M. J., Jeon, Y. H., Park, Y., Choi, D., Lee, W. J., & Lim, H. K. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1262 · Cited by 311
Lewin, J. M., Hendrick, R. E., D’Orsi, C. J., Isaacs, P. K., Moss, L. J., Karellas, A., Sisney, G. A., Kuni, C. C., & Cutter, G. R. (2001) · Radiology · doi:10.1148/radiology.218.3.r01mr29873 · Cited by 303
Computer-Aided Detection and Diagnosis in Mammography
Sampat, M. P., Markey, M. K., & Bovik, A. C. (2005) · Handbook of Image and Video Processing · doi:10.1016/b978-012119792-6/50130-3 · Cited by 302
Metz, C. E. (2006) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2006.02.021 · Cited by 274
Awai, K., Murao, K., Ozawa, A., Komi, M., Hayakawa, H., Hori, S., & Nishimura, Y. (2004) · Radiology · doi:10.1148/radiol.2302030049 · Cited by 272
Suzuki, K., Armato, S. G., Li, F., Sone, S., & Doi, K. (2003) · Medical Physics · doi:10.1118/1.1580485 · Cited by 262
Evaluating quality of compressed medical images: SNR, subjective rating, and diagnostic accuracy
Cosman, P. C., Gray, R. M., & Olshen, R. A. (1994) · Proceedings of the IEEE · doi:10.1109/5.286196 · Cited by 260
Rubin, G. D., Lyo, J. K., Paik, D. S., Sherbondy, A. J., Chow, L. C., Leung, A. N., Mindelzun, R., Schraedley-Desmond, P. K., Zinck, S. E., Naidich, D. P., et al. (2005) · Radiology · doi:10.1148/radiol.2341040589 · Cited by 259
Lewin, J. M., D'Orsi, C. J., Hendrick, R. E., Moss, L. J., Isaacs, P. K., Karellas, A., & Cutter, G. R. (2002) · American Journal of Roentgenology · doi:10.2214/ajr.179.3.1790671 · Cited by 257
Quantitative Comparison of Spot Detection Methods in Fluorescence Microscopy
Smal, I., Loog, M., Niessen, W., & Meijering, E. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2025127 · Cited by 255
Markov random field for tumor detection in digital mammography
Li, H. D., Kallergi, M., Clarke, L. P., Jain, V. K., & Clark, R. A. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.414622 · Cited by 246
“This curve is referred to as free response receiver operating characteristic (FROC) curve in observer performance studies but also allows the evaluation of computer results alone [ 29 ].”
MethodYoshida, H., Masutani, Y., MacEneaney, P., Rubin, D. T., & Dachman, A. H. (2002) · Radiology · doi:10.1148/radiol.2222010506 · Cited by 243
Ward, J., Naik, K. S., Guthrie, J. A., Wilson, D., & Robinson, P. J. (1999) · Radiology · doi:10.1148/radiology.210.2.r99fe05459 · Cited by 230
Computer-Aided Diagnosis and Artificial Intelligence in Clinical Imaging
Shiraishi, J., Li, Q., Appelbaum, D., & Doi, K. (2011) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2011.06.004 · Cited by 206
How experience and training influence mammography expertise
Nodine, C. F., Kundel, H. L., Mello-Thoms, C., Weinstein, S. P., Orel, S. G., Sullivan, D. C., & Conant, E. F. (1999) · Academic Radiology · doi:10.1016/s1076-6332(99)80252-9 · Cited by 198
Park, M. J., Kim, Y. K., Lee, M. W., Lee, W. J., Kim, Y.-S., Kim, S. H., Choi, D., & Rhim, H. (2012) · Radiology · doi:10.1148/radiol.12112517 · Cited by 190
Reimer, P., Jähnke, N., Fiebich, M., Schima, W., Deckers, F., Marx, C., Holzknecht, N., & Saini, S. (2000) · Radiology · doi:10.1148/radiology.217.1.r00oc31152 · Cited by 188
Metadata
- Authors
- Chakraborty, D. P., & Winter, L. H.
- Venue
- Radiology
- Published
- 1990-03
- Volume
- 174
- Issue
- 3
- Pages
- 873-881
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2084656440
- Cited by
- 363
- References
- 0
- FWCI
- 5.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.