Brain motion: measurement with phase-contrast MR imaging.
The DOI matches its Crossref record.
Abstract
Brain motion during the cardiac cycle was measured prospectively in 10 healthy volunteers by using a phase-contrast cine magnetic resonance (MR) pulse sequence. The major cerebral lobes, diencephalon, brain stem, cerebellum, cerebellar tonsils, and spinal cord were studied. The overall pattern of brain motion showed caudal motion of the central structures (diencephalon, brain stem, and cerebellar tonsils) shortly after carotid systole, with concurrent cephalic motion of the major cerebral lobes and posterior cerebellar hemisphere. Peak brain displacement was in the range of 0.1-0.5 mm for all the structures except the cerebellar tonsils, which had greater displacement (0.4 mm +/- 0.16 [mean +/- standard error of mean]). Caudal motion of the central structures did not occur simultaneously but progressed in a caudal-to-rostral and posterior-to-anterior sequence, being seen first in the cerebellar tonsils and then later in the diencephalon (hypothalamus). Caudal motion of the low brain stem and cerebellar tonsil was simultaneous with caudal motion of cerebrospinal fluid in the cervical subarachnoid space. Oscillatory flow in the aqueduct was delayed compared with brain stem motion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The influence of head motion on intrinsic functional connectivity MRI
Van Dijk, K. R. A., Sabuncu, M. R., & Buckner, R. L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.07.044 · Cited by 2,344
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Electronic dura mater for long-term multimodal neural interfaces
Minev, I. R., Musienko, P., Hirsch, A., Barraud, Q., Wenger, N., Moraud, E. M., Gandar, J., Capogrosso, M., Milekovic, T., Asboth, L., et al. (2015) · Science · doi:10.1126/science.1260318 · Cited by 1,082
Diffusion tensor imaging and beyond
Tournier, J., Mori, S., & Leemans, A. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22924 · Cited by 921
Super-resolution Ultrasound Imaging
Christensen-Jeffries, K., Couture, O., Dayton, P. A., Eldar, Y. C., Hynynen, K., Kiessling, F., O'Reilly, M., Pinton, G. F., Schmitz, G., Tang, M.-X., et al. (2020) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2019.11.013 · Cited by 558
Radiological assessment of hydrocephalus: new theories and implications for therapy
Greitz, D. (2004) · Neurosurgical Review · doi:10.1007/s10143-004-0326-9 · Cited by 393
Normal-pressure hydrocephalus: evaluation with cerebrospinal fluid flow measurements at MR imaging.
Bradley, W. G., Scalzo, D., Queralt, J., Nitz, W. N., Atkinson, D. J., & Wong, P. (1996) · Radiology · doi:10.1148/radiology.198.2.8596861 · Cited by 392
Localization of Cardiac-Induced Signal Change in fMRI
Dagli, M. S., Ingeholm, J. E., & Haxby, J. V. (1999) · NeuroImage · doi:10.1006/nimg.1998.0424 · Cited by 384
Jones, D. K., & Leemans, A. (2011) · Methods in Molecular Biology · doi:10.1007/978-1-61737-992-5_6 · Cited by 379
In vivo mapping of the human locus coeruleus
Keren, N. I., Lozar, C. T., Harris, K. C., Morgan, P. S., & Eckert, M. A. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.06.012 · Cited by 308
Reduction of signal fluctuation in functional MRI using navigator echoes
Hu, X., & Kim, S. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910310505 · Cited by 252
Virta, A., Barnett, A., & Pierpaoli, C. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00048-x · Cited by 201
Luetmer, P. H., Huston, J., Friedman, J. A., Dixon, G. R., Petersen, R. C., Jack, C. R., McClelland, R. L., & Ebersold, M. J. (2002) · Neurosurgery · doi:10.1097/00006123-200203000-00020 · Cited by 198
“During CSF diastole, venous blood exits the cranial vault at a faster rate than arterial blood enters it, with a resultant net loss in intracranial blood volume and a reversal of CSF flow (3, 9, 12, 24, 27, 30).”
BackgroundBrainstem functional magnetic resonance imaging: Disentangling signal from physiological noise
Harvey, A. K., Pattinson, K. T. S., Brooks, J. C. W., Mayhew, S. D., Jenkinson, M., & Wise, R. G. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21623 · Cited by 195
Pulsatile Cerebrospinal Fluid Dynamics in the Human Brain
Linninger, A. A., Tsakiris, C., Zhu, D. C., Xenos, M., Roycewicz, P., Danziger, Z., & Penn, R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.844021 · Cited by 169
“D dynamic CFD simulations; 2) in vivo CINE phase-contrast imaging of CSF velocities in a normal human subject; and 3) a hydraulic experiment with a surrogate “hydraulic brain model.””
BackgroundMethodBaudrexel, S., Nürnberger, L., Rüb, U., Seifried, C., Klein, J. C., Deller, T., Steinmetz, H., Deichmann, R., & Hilker, R. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.005 · Cited by 160
“Pulsatile motion of the brain related to the cardiac and respiratory cycle is another serious source of variability, deteriorating MR-image quality in this region, possibly contributing to false negative results (Enzmann and Pelc, 1992; Harvey et al., 2008).”
BackgroundKern, M., Aertsen, A., Schulze-Bonhage, A., & Ball, T. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.042 · Cited by 153
“The resulting intracranial pressure wave starts in the frontal lobe and moves into the more posterior parts of the brain, thus causing a motion of brain tissue (Enzmann and Pelc, 1992; Greitz et al., 1992; Wagshul et al., 2011).”
Human brain: Proton diffusion MR spectroscopy
Posse, S., Cuenod, C. A., & Le Bihan, D. (1993) · Radiology · doi:10.1148/radiology.188.3.8351339 · Cited by 122
Conformable hybrid systems for implantable bioelectronic interfaces
Fallegger, F., Schiavone, G., & Lacour, S. P. (2020) · Advanced Materials · doi:10.1002/adma.201903904 · Cited by 113
Midbrain fMRI: Applications, Limitations and Challenges
Düzel, E., Guitart-Masip, M., Maass, A., Hämmerer, D., Betts, M. J., Speck, O., Weiskopf, N., & Kanowski, M. (2015) · Biological Magnetic Resonance · doi:10.1007/978-1-4899-7591-1_20 · Cited by 16
Metadata
- Authors
- Enzmann, D. R., & Pelc, N. J.
- Venue
- Radiology
- Published
- 1992-12
- Volume
- 185
- Issue
- 3
- Pages
- 653-660
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W1971675275
- Cited by
- 273
- References
- 0
- FWCI
- 7.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.