"Black blood" T2-weighted inversion-recovery MR imaging of the heart.
The DOI matches its Crossref record.
Abstract
PURPOSE: To develop a short-inversion-time inversion-recovery (STIR) magnetic resonance imaging pulse sequence for evaluating the myocardium that is relatively free of flow and motion artifact. MATERIALS AND METHODS: The authors implemented a breath-hold, cardiac-triggered STIR sequence with preparatory radio-frequency pulses to eliminate signal from flowing blood. A segmented rapid acquisition with relaxation enhancement (turbo spin echo) readout was used, with the inversion-recovery delay adjusted to null fat. The sequence was implemented at 1.0 and 1.5 T and tested in phantoms, five healthy volunteers, and three patients. RESULTS: Phantom studies confirmed the expected behavior of the sequence. In the volunteers, fat-suppressed images of the heart with STIR contrast were generated in a breath-hold period. Blood in the heart chambers was uniformly nulled, and motion artifacts were effectively suppressed. Focal high signal intensity consistent with edema was seen in two patients with acute myocardial infarction; in a third patient, a paracardiac mass was visualized and sharply demarcated relative to normal myocardium. CONCLUSION: Fast STIR imaging of the heart with effective suppression of flow and motion artifacts was implemented. The approach has much potential for high-contrast imaging in a variety of diseases affecting the heart and mediastinum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cardiovascular Magnetic Resonance in Nonischemic Myocardial Inflammation
Ferreira, V. M., Schulz-Menger, J., Holmvang, G., Kramer, C. M., Carbone, I., Sechtem, U., Kindermann, I., Gutberlet, M., Cooper, L. T., Liu, P., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.09.072 · Cited by 2,059
An Improved MR Imaging Technique for the Visualization of Myocardial Infarction
Simonetti, O. P., Kim, R. J., Fieno, D. S., Hillenbrand, H. B., Wu, E., Bundy, J. M., Finn, J. P., & Judd, R. M. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja50215 · Cited by 1,358
Self-citationWRITING COMMITTEE MEMBERS, Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181d44a8f · Cited by 821
Self-citationT2 quantification for improved detection of myocardial edema
Giri, S., Chung, Y.-C., Merchant, A., Mihai, G., Rajagopalan, S., Raman, S. V., & Simonetti, O. P. (2009) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-11-56 · Cited by 680
Self-citationACCF/ACR/AHA/NASCI/SCMR 2010 Expert Consensus Document on Cardiovascular Magnetic Resonance
Hundley, W. G., Bluemke, D. A., Finn, J. P., Flamm, S. D., Fogel, M. A., Friedrich, M. G., Ho, V. B., Jerosch-Herold, M., Kramer, C. M., Manning, W. J., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.011 · Cited by 593
Self-citationFayad, Z. A., Fuster, V., Fallon, J. T., Jayasundera, T., Worthley, S. G., Helft, G., Aguinaldo, J. G., Badimon, J. J., & Sharma, S. K. (2000) · Circulation · doi:10.1161/01.cir.102.5.506 · Cited by 581
Abdel-Aty, H., Zagrosek, A., Schulz-Menger, J., Taylor, A. J., Messroghli, D., Kumar, A., Gross, M., Dietz, R., & Friedrich, M. G. (2004) · Circulation · doi:10.1161/01.cir.0000127428.10985.c6 · Cited by 539
Aletras, A. H., Tilak, G. S., Natanzon, A., Hsu, L.-Y., Gonzalez, F. M., Hoyt, R. F., & Arai, A. E. (2006) · Circulation · doi:10.1161/circulationaha.105.576025 · Cited by 532
Friedrich, M. G., Abdel-Aty, H., Taylor, A., Schulz-Menger, J., Messroghli, D., & Dietz, R. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.01.019 · Cited by 514
Lancellotti, P., Nkomo, V. T., Badano, L. P., Bergler, J., Bogaert, J., Davin, L., Cosyns, B., Coucke, P., Dulgheru, R., Edvardsen, T., et al. (2013) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2013.07.005 · Cited by 484
Ferreira, V. M., Piechnik, S. K., Dall'Armellina, E., Karamitsos, T. D., Francis, J. M., Choudhury, R. P., Friedrich, M. G., Robson, M. D., & Neubauer, S. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-42 · Cited by 460
T1 Mapping for the Diagnosis of Acute Myocarditis Using CMR
Ferreira, V. M., Piechnik, S. K., Dall'Armellina, E., Karamitsos, T. D., Francis, J. M., Ntusi, N., Holloway, C., Choudhury, R. P., Kardos, A., Robson, M. D., et al. (2013) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2013.03.008 · Cited by 383
Lancellotti, P., Nkomo, V. T., Badano, L. P., Bergler-Klein, J., Bogaert, J., Davin, L., Cosyns, B., Coucke, P., Dulgheru, R., Edvardsen, T., et al. (2013) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jet123 · Cited by 353
Direct T2 Quantification of Myocardial Edema in Acute Ischemic Injury
Verhaert, D., Thavendiranathan, P., Giri, S., Mihai, G., Rajagopalan, S., Simonetti, O. P., & Raman, S. V. (2011) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2010.09.023 · Cited by 352
Self-citationWasserman, B. A., Smith, W. I., Trout, H. H., Cannon, R. O., Balaban, R. S., & Arai, A. E. (2002) · Radiology · doi:10.1148/radiol.2232010659 · Cited by 333
Takayasu arteritis: Utility and limitations of magnetic resonance imaging in diagnosis and treatment
Tso, E., Flamm, S. D., White, R. D., Schvartzman, P. R., Mascha, E., & Hoffman, G. S. (2002) · Arthritis & Rheumatism · doi:10.1002/art.10251 · Cited by 325
Self-citationImproved Detection of Myocardial Involvement in Acute Inflammatory Cardiomyopathies Using T2 Mapping
Thavendiranathan, P., Walls, M., Giri, S., Verhaert, D., Rajagopalan, S., Moore, S., Simonetti, O. P., & Raman, S. V. (2012) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.111.967836 · Cited by 324
Self-citationFayad, Z. A., Nahar, T., Fallon, J. T., Goldman, M., Aguinaldo, J. G., Badimon, J. J., Shinnar, M., Chesebro, J. H., & Fuster, V. (2000) · Circulation · doi:10.1161/01.cir.101.21.2503 · Cited by 322
Survival and Left Ventricular Function Changes in Fulminant Versus Nonfulminant Acute Myocarditis
Ammirati, E., Cipriani, M., Lilliu, M., Sormani, P., Varrenti, M., Raineri, C., Petrella, D., Garascia, A., Pedrotti, P., Roghi, A., et al. (2017) · Circulation · doi:10.1161/circulationaha.117.026386 · Cited by 292
Francone, M., Bucciarelli-Ducci, C., Carbone, I., Canali, E., Scardala, R., Calabrese, F. A., Sardella, G., Mancone, M., Catalano, C., Fedele, F., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.08.024 · Cited by 284
Kellman, P., Aletras, A. H., Mancini, C., McVeigh, E. R., & Arai, A. E. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21215 · Cited by 247
Francone, M., Chimenti, C., Galea, N., Scopelliti, F., Verardo, R., Galea, R., Carbone, I., Catalano, C., Fedele, F., & Frustaci, A. (2014) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2013.10.011 · Cited by 243
“Technical details of this sequence have been described elsewhere (11).”
BackgroundCardiovascular magnetic resonance physics for clinicians: part II
Biglands, J. D., Radjenovic, A., & Ridgway, J. P. (2012) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-14-66 · Cited by 241
T2-weighted cardiovascular magnetic resonance in acute cardiac disease
Eitel, I., & Friedrich, M. G. (2011) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-13-13 · Cited by 239
Ferreira, V. M., Piechnik, S. K., Dall'Armellina, E., Karamitsos, T. D., Francis, J. M., Ntusi, N., Holloway, C., Choudhury, R. P., Kardos, A., Robson, M. D., et al. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-16-36 · Cited by 226
“Dark-blood T2-weighted imaging for edema was performed using the STIR sequence [1,10] and T1-mapping using the”
MethodT2 mapping in myocardial disease: a comprehensive review
O’Brien, A. T., Gil, K. E., Varghese, J., Simonetti, O. P., & Zareba, K. M. (2022) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-022-00866-0 · Cited by 224
Self-citationT2‐weighted cardiovascular magnetic resonance imaging
Abdel‐Aty, H., Simonetti, O., & Friedrich, M. G. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21028 · Cited by 221
“The 90° excitation pulse of the TSE readout is then applied in diastole after the heart has returned to approximately the same shape and position that it was when the blood-nulling preparation was applied at the R-wave.”
BackgroundMethodInfluentialSelf-citationCardiovascular magnetic resonance physics for clinicians: part I
Ridgway, J. P. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-71 · Cited by 218
“In order to improve the effectiveness of black blood imaging it is common to use a black blood magnetisation preparation scheme in combination with the spin echo pulse sequence [9,22].”
Cardiac MR Imaging: State of the Technology
Finn, J. P., Nael, K., Deshpande, V., Ratib, O., & Laub, G. (2006) · Radiology · doi:10.1148/radiol.2412041866 · Cited by 215
Self-citationThe effect of daily caffeine use on cerebral blood flow: How much caffeine can we tolerate?
Addicott, M. A., Yang, L. L., Peiffer, A. M., Burnett, L. R., Burdette, J. H., Chen, M. Y., Hayasaka, S., Kraft, R. A., Maldjian, J. A., & Laurienti, P. J. (2009) · Human Brain Mapping · doi:10.1002/hbm.20732 · Cited by 210
“Based on the literature, the T1 of blood was assumed to be 1,200 ms at 1.5T [Simonetti et al., 1996].”
MethodLønborg, J., Kelbæk, H., Vejlstrup, N., Bøtker, H. E., Kim, W. Y., Holmvang, L., Jørgensen, E., Helqvist, S., Saunamäki, K., Terkelsen, C. J., et al. (2012) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.112.968388 · Cited by 210
Cardiovascular magnetic resonance artefacts
Ferreira, P. F., Gatehouse, P. D., Mohiaddin, R. H., & Firmin, D. N. (2013) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-15-41 · Cited by 191
“For cardiovascular morphology, a double-inversion RF pulse preparation is commonly added to a turbo spinecho sequence, removing the blood signal and providing a good contrast between the myocardium and blood, and is commonly referred as black or dark-blood preparation [23].”
Motion in Cardiovascular MR Imaging
Scott, A. D., Keegan, J., & Firmin, D. N. (2009) · Radiology · doi:10.1148/radiol.2502071998 · Cited by 175
Epidemiology Characteristics and Outcome of Patients With Clinically Diagnosed Acute Myocarditis
Younis, A., Matetzky, S., Mulla, W., Masalha, E., Afel, Y., Chernomordik, F., Fardman, A., Goitein, O., Ben-Zekry, S., Peled, Y., et al. (2020) · The American Journal of Medicine · doi:10.1016/j.amjmed.2019.10.015 · Cited by 88
Metadata
- Authors
- Simonetti, O. P., Finn, J. P., White, R. D., Laub, G., & Henry, D. A.
- Venue
- Radiology
- Published
- 1996-04
- Volume
- 199
- Issue
- 1
- Pages
- 49-57
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2151925756
- Cited by
- 560
- References
- 0
- FWCI
- 11.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.