Multidetector CT of Aortic Dissection: A Pictorial Review
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Aortic dissection is the most common acute emergency condition of the aorta and often has a fatal outcome. Outcome is determined by the type and extent of dissection and the presence of associated complications (eg, cerebral sequelae, aortic branch involvement, pericardial involvement, and visceral involvement), with early diagnosis and treatment being essential for improved prognosis. Aortic dissections are classified on the basis of the site of the intimal tear according to the Stanford classification system. Type A aortic dissection involves the ascending thoracic aorta and may extend into the descending aorta, whereas in a type B dissection the intimal tear is located distal to the left subclavian artery. Type A dissection typically requires urgent surgical intervention, whereas type B dissection can often be treated medically. Modern multidetector computed tomography (CT) is a fast, widely available imaging modality with high sensitivity and specificity. Multidetector CT allows the early recognition and characterization of aortic dissection as well as determination of the presence of any associated complications, findings that are essential for optimizing treatment and improving clinical outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The International Registry of Acute Aortic Dissection (IRAD): New Insights Into an Old Disease
Hagan, P. G., Nienaber, C. A., Isselbacher, E. M., Bruckman, D., Karavite, D. J., Russman, P. L., Evangelista, A., Fattori, R., Suzuki, T., Oh, J. K., et al. (2000) · JAMA · doi:10.1001/jama.283.7.897 · Cited by 3,623 · cited 9×
“Aortic regurgitation gives rise to a diastolic murmur, which has been reported in 40%–50% of patients with proximal dissections (3), and severe regurgitation can result in heart failure (12,14,15).”
BackgroundInfluentialManagement of Acute Aortic Dissections
Daily, P. O., Trueblood, H. W., Stinson, E. B., Wuerflein, R. D., & Shumway, N. E. (1970) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(10)65594-4 · Cited by 1,255 · cited 1×
“Definition of Types of Dissection The Stanford classification system for dissections is based on the need for surgical intervention (24).”
BackgroundErbel, R. (2001) · European Heart Journal · doi:10.1053/euhj.2001.2782 · Cited by 1,217
The Diagnosis of Thoracic Aortic Dissection by Noninvasive Imaging Procedures
Nienaber, C. A., von Kodolitsch, Y., Nicolas, V., Siglow, V., Piepho, A., Brockhoff, C., Koschyk, D. H., & Spielmann, R. P. (1993) · New England Journal of Medicine · doi:10.1056/nejm199301073280101 · Cited by 970
Risk factors for aortic dissection: A necropsy study of 161 cases
Larson, E. W., & Edwards, W. D. (1984) · The American Journal of Cardiology · doi:10.1016/0002-9149(84)90418-1 · Cited by 910 · cited 1×
“Rarer associations include other connective tissue diseases such as Ehlers-Danlos syndrome, relapsing polychondritis, Behçet disease, Turner syndrome, aortitis (systemic lupus erythematosus), and infections (14,32).”
BackgroundNienaber, C. A., & Eagle, K. A. (2003) · Circulation · doi:10.1161/01.cir.0000087009.16755.e4 · Cited by 657
Suzuki, T., Mehta, R. H., Ince, H., Nagai, R., Sakomura, Y., Weber, F., Sumiyoshi, T., Bossone, E., Trimarchi, S., Cooper, J. V., et al. (2003) · Circulation · doi:10.1161/01.cir.0000087386.07204.09 · Cited by 590
Predicting Death in Patients With Acute Type A Aortic Dissection
Mehta, R. H., Suzuki, T., Hagan, P. G., Bossone, E., Gilon, D., Llovet, A., Maroto, L. C., Cooper, J. V., Smith, D. E., Armstrong, W. F., et al. (2002) · Circulation · doi:10.1161/hc0202.102246 · Cited by 581 · cited 2×
“Cerebrovascular manifestations and limb ischemia with pulse deficits may occur due to side branch orifice involvement by the dissection flap or obliteration of the true lumen by an expanding false lumen (2,16).”
BackgroundGender-Related Differences in Acute Aortic Dissection
Nienaber, C. A., Fattori, R., Mehta, R. H., Richartz, B. M., Evangelista, A., Petzsch, M., Cooper, J. V., Januzzi, J. L., Ince, H., Sechtem, U., et al. (2004) · Circulation · doi:10.1161/01.cir.0000130644.78677.2c · Cited by 538
Januzzi, J. L., Isselbacher, E. M., Fattori, R., Cooper, J. V., Smith, D. E., Fang, J., Eagle, K. A., Mehta, R. H., Nienaber, C. A., & Pape, L. A. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.054 · Cited by 511
Shiga, T., Wajima, Z., Apfel, C. C., Inoue, T., & Ohe, Y. (2006) · Archives of Internal Medicine · doi:10.1001/archinte.166.13.1350 · Cited by 510 · cited 4×
“Transesophageal echocardiography (TEE) is reported to have a sensitivity of 94%–100% and a specificity of 77%–100% for identifying an intimal flap (37,38).”
BackgroundMethodResultInfluentialFour Multidetector-Row Helical CT: Image Quality and Volume Coverage Speed
Hu, H., He, H. D., Foley, W. D., & Fox, S. H. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap3755 · Cited by 509
Vascular complications associated with spontaneous aortic dissection
Cambria, R. P., Brewster, D. C., Gertler, J., Moncure, A. C., Gusberg, R., Tilson, M. D., Darling, R. C., Hammond, G., Megerman, J., & Abbott, W. M. (1988) · Journal of Vascular Surgery · doi:10.1016/0741-5214(88)90137-1 · Cited by 505 · cited 2×
“5% mortality risk) (3); hemodynamic instability; a descending aortic diameter greater than 6 cm; poor perfusion of the thoracoabdominal aorta; mesenteric, renal, and extremity ischemia causing secondary compression of the true lumen by the expanding false lumen (11); pseudocoarctation syndrome with uncontrolled hypert…”
BackgroundAortic Dissection: New Frontiers in Diagnosis and Management
Nienaber, C. A., & Eagle, K. A. (2003) · Circulation · doi:10.1161/01.cir.0000087400.48663.19 · Cited by 365
Schoepf, U. J., Becker, C. R., Ohnesorge, B. M., & Yucel, E. K. (2004) · Radiology · doi:10.1148/radiol.2321030636 · Cited by 356
Mehta, R. H., O’Gara, P. T., Bossone, E., Nienaber, C. A., Myrmel, T., Cooper, J. V., Smith, D. E., Armstrong, W. F., Isselbacher, E. M., Pape, L. A., et al. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)02005-3 · Cited by 308
Randoux, B., Marro, B., Koskas, F., Duyme, M., Sahel, M., Zouaoui, A., & Marsault, C. (2001) · Radiology · doi:10.1148/radiology.220.1.r01jl35179 · Cited by 300
Three-dimensional gadolinium-enhanced MR angiography of the thoracic aorta.
Prince, M. R., Narasimham, D. L., Jacoby, W. T., Williams, D. M., Cho, K. J., Marx, M. V., & Deeb, G. M. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.6.8633452 · Cited by 296
Roos, J. E., Willmann, J. K., Weishaupt, D., Lachat, M. L., Marinček, B., & Hilfiker, P. R. (2002) · Radiology · doi:10.1148/radiol.2221010481 · Cited by 223 · cited 1×
“The radiation exposure in retrospectively ECG-gated CT angiography is higher than that in nongated chest protocols (50).”
BackgroundAortic Dissection: CT Features that Distinguish True Lumen from False Lumen
LePage, M. A., Quint, L. E., Sonnad, S. S., Deeb, G. M., & Williams, D. M. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.177.1.1770207 · Cited by 219 · cited 1×
“Le Page et al (59) described the beak sign seen at cross-sectional imaging as a wedge of hematoma that creates a space for the propagation of the false lumen (Fig 9).”
BackgroundWillmann, J. K., Wildermuth, S., Pfammatter, T., Roos, J. E., Seifert, B., Hilfiker, P. R., Marincek, B., & Weishaupt, D. (2003) · Radiology · doi:10.1148/radiol.2271020014 · Cited by 197
Halpern, E. J. (2009) · Radiology · doi:10.1148/radiol.2522082335 · Cited by 197 · cited 4×
“Scanning parameters, including prospective ECG tube current modulation and prospective ECG gating, are tailored to reduce radiation exposure (optimally, 5–9 mSv) (48).”
BackgroundInfluentialDesjardins, B., & Kazerooni, E. A. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.182.4.1820993 · Cited by 192 · cited 4×
“Radiation dose should be high enough to maintain an appropriate contrast-to-noise ratio for diagnostic-quality images, but no higher (49).”
BackgroundMethodInfluentialSvensson, L. A. R. G., & Crawford, E. S. (1992) · Current Problems in Surgery · doi:10.1016/0011-3840(92)90003-l · Cited by 180
Ascending vs Descending Aortic Dissections
Appelbaum, A., Karp, R. B., & Kirklin, J. W. (1976) · Annals of Surgery · doi:10.1097/00000658-197603000-00015 · Cited by 149
Pathophysiology, diagnosis, and management of aortic dissection
Patel, P. D., & Arora, R. R. (2008) · Therapeutic Advances in Cardiovascular Disease · doi:10.1177/1753944708090830 · Cited by 115 · cited 1×
“In general, the dissection may remain patent as a false lumen, thrombose, recommunicate with the true lumen through fenestrations, or rupture into potential spaces such as the pericardial, pleural, or peritoneal cavities (20).”
BackgroundHelical CT Angiography of the Thoracic Aorta
Rubin, G. D. (1997) · Journal of Thoracic Imaging · doi:10.1097/00005382-199704000-00011 · Cited by 102 · cited 1×
“Pitfalls of Multidetector CT Most of the artifacts at CT can be due to either (a) perivenous streaks from a combination of beam-hardening and motion artifacts from pulsations in veins carrying undiluted contrast material to the heart, or (b) aortic motion artifact (Fig 11) (61); such artifacts can lead to false-positi…”
BackgroundDiagnosis of aortic dissection by transesophageal echocardiography
Börner, N., Erbel, R. M., Braun, B., Henkel, B., Meyer, J., & Rumpelt, J. (1984) · The American Journal of Cardiology · doi:10.1016/s0002-9149(84)80175-7 · Cited by 91 · cited 8×
“TEE can be performed in the emergency department at the bedside of unstable patients, thereby helping prevent delays in accurate diagnosis and treatment.”
BackgroundInfluentialComputer-assisted Analysis of Three-dimensional MR Angiograms
Hernández-Hoyos, M., Orkisz, M., Puech, P., Desbleds‐Mansard, C., Douek, P., & Magnin, I. E. (2002) · Radiographics · doi:10.1148/radiographics.22.2.g02mr03421 · Cited by 67
Jimenez Romo, F. (1962) · PubMed · Cited by 30
CT of Calcified Chronic Aortic Dissection Simulating Atherosclerotic Aneurysm
Hachiya, J., Nitatori, T., Yoshino, A., et al. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199305000-00006 · Cited by 14 · cited 1×
“A calcified false lumen can be seen in chronic dissections with mural calcification of the false lumen (56).”
Background
Cited by
The Role of Imaging in Aortic Dissection and Related Syndromes
Baliga, R. R., Nienaber, C. A., Bossone, E., Oh, J. K., Isselbacher, E. M., Sechtem, U., Fattori, R., Raman, S. V., & Eagle, K. A. (2014) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2013.10.015 · Cited by 232
Zoghbi, W. A., Jone, P.-N., Chamsi-Pasha, M. A., Chen, T., Collins, K. A., Desai, M. Y., Grayburn, P., Groves, D. W., Hahn, R. T., Little, S. H., et al. (2024) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2023.10.004 · Cited by 197
Complex adult congenital heart disease on cross-sectional imaging: an introductory overview
Saleh, M., Gendy, D., Voges, I., Nyktari, E., & Arzanauskaite, M. (2022) · Insights into Imaging · doi:10.1186/s13244-022-01201-y · Cited by 7
“Contrast-enhanced CT may demonstrate a variety of findings such as intimal flap and a double lumen [49].”
Background
Metadata
- Authors
- McMahon, M. A., & Squirrell, C. A.
- Venue
- RadioGraphics
- Published
- 2010-03
- Volume
- 30
- Issue
- 2
- Pages
- 445-460
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2138416265
- Cited by
- 229
- References
- 31
- FWCI
- 10.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.