The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Fat-Suppression Techniques for 3-T MR Imaging of the Musculoskeletal System
Open accessAbstract
Fat suppression is an important technique in musculoskeletal imaging to improve the visibility of bone-marrow lesions; evaluate fat in soft-tissue masses; optimize the contrast-to-noise ratio in magnetic resonance (MR) arthrography; better define lesions after administration of contrast material; and avoid chemical shift artifacts, primarily at 3-T MR imaging. High-field-strength (eg, 3-T) MR imaging has specific technical characteristics compared with lower-field-strength MR imaging that influence the use and outcome of various fat-suppression techniques. The most commonly used fat-suppression techniques for musculoskeletal 3-T MR imaging include chemical shift (spectral) selective (CHESS) fat saturation, inversion recovery pulse sequences (eg, short inversion time inversion recovery [STIR]), hybrid pulse sequences with spectral and inversion-recovery (eg, spectral adiabatic inversion recovery and spectral attenuated inversion recovery [SPAIR]), spatial-spectral pulse sequences (ie, water excitation), and the Dixon techniques. Understanding the different fat-suppression options allows radiologists to adopt the most appropriate technique for their clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arrays
Sodickson, D. K., & Manning, W. J. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910380414 · Cited by 2,142
Krssak, M., Falk Petersen, K., Dresner, A., DiPietro, L., Vogel, S. M., Rothman, D. L., Shulman, G. I., & Roden, M. (1999) · Diabetologia · doi:10.1007/s001250051123 · Cited by 1,264
1H NMR chemical shift selective (CHESS) imaging
Haase, A., Frahm, J., Hanicke, W., & Matthaei, D. (1985) · Physics in Medicine and Biology · doi:10.1088/0031-9155/30/4/008 · Cited by 1,062
Reeder, S. B., Pineda, A. R., Wen, Z., Shimakawa, A., Yu, H., Brittain, J. H., Gold, G. E., Beaulieu, C. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20624 · Cited by 706
Self-citationThree‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Jacob, S., Machann, J., Rett, K., Brechtel, K., Volk, A., Renn, W., Maerker, E., Matthaei, S., Schick, F., Claussen, C. D., et al. (1999) · Diabetes · doi:10.2337/diabetes.48.5.1113 · Cited by 643
Musculoskeletal MRI at 3.0 T: Relaxation Times and Image Contrast
Gold, G. E., Han, E., Stainsby, J., Wright, G., Brittain, J., & Beaulieu, C. (2004) · American Journal of Roentgenology · doi:10.2214/ajr.183.2.1830343 · Cited by 517
Self-citationMulticoil Dixon chemical species separation with an iterative least‐squares estimation method
Reeder, S. B., Wen, Z., Yu, H., Pineda, A. R., Gold, G. E., Markl, M., & Pelc, N. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10675 · Cited by 508
Self-citationSimultaneous spatial and spectral selective excitation
Meyer, C. H., Pauly, J. M., Macovskiand, A., & Nishimura, D. G. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150211 · Cited by 498
Fat Suppression in MR Imaging: Techniques and Pitfalls
Delfaut, E. M., Beltran, J., Johnson, G., Rousseau, J., Marchandise, X., & Cotten, A. (1999) · RadioGraphics · doi:10.1148/radiographics.19.2.g99mr03373 · Cited by 487
Boesch, C., Slotboom, J., Hoppeler, H., & Kreis, R. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370403 · Cited by 421
Multipoint dixon technique for water and fat proton and susceptibility imaging
Glover, G. H. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010504 · Cited by 405
Fat and water magnetic resonance imaging
Bley, T. A., Wieben, O., François, C. J., Brittain, J. H., & Reeder, S. B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21895 · Cited by 372
Schick, F., Eismann, B., Jung, W., Bongers, H., Bunse, M., & Lutz, O. (1993) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910290203 · Cited by 349
Field map estimation with a region growing scheme for iterative 3‐point water‐fat decomposition
Yu, H., Reeder, S. B., Shimakawa, A., Brittain, J. H., & Pelc, N. J. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20654 · Cited by 217
BERNSTEIN, M. A., KING, K. F., & ZHOU, X. J. (2004) · Handbook of MRI Pulse Sequences · doi:10.1016/b978-012092861-3/50021-2 · Cited by 209
ISMRM workshop on fat–water separation: Insights, applications and progress in MRI
Hu, H. H., Börnert, P., Hernando, D., Kellman, P., Ma, J., Reeder, S., & Sirlin, C. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24369 · Cited by 189
Multisection fat-water imaging with chemical shift selective presaturation.
Keller, P. J., Hunter, W. W., & Schmalbrock, P. (1987) · Radiology · doi:10.1148/radiology.164.2.3602398 · Cited by 146
Krinsky, G. A., Rofsky, N. M., & Weinreb, J. C. (1996) · American Journal of Roentgenology · doi:10.2214/ajr.166.3.8623620 · Cited by 121
Phase Maps Filtering Methods in Dixon Technique on Dedicated Low Field Scanners
Balbi, L., Caramella, D., Giunta, G., & Greco, D. (2012) · CINECA IRIS Institutial research information system (Parthenope University of Naples) · Cited by 110
The short TI inversion recovery sequence—An approach to MR imaging of the abdomen
Bydder, G. M., Pennock, J. M., Steiner, R. E., Khenia, S., Payne, J. A., & YOUNG, I. R. (1985) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(85)90354-6 · Cited by 100
Bulk magnetic susceptibility effects on the assessment of intra‐ and extramyocellular lipids in vivo
Szczepaniak, L. S., Dobbins, R. L., Stein, D. T., & McGarry, J. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10086 · Cited by 87
Gerdes, C. M., Kijowski, R., & Reeder, S. B. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.07.2593 · Cited by 71
Gold, G. E., Reeder, S. B., Yu, H., Kornaat, P. R., Shimakawa, A. S., Johnson, J. W., Pelc, N. J., Beaulieu, C. F., & Brittain, J. H. (2006) · Radiology · doi:10.1148/radiol.2402050288 · Cited by 69
Self-citationKijowski, R., Blankenbaker, D. G., Woods, M. A., Shinki, K., Smet, A. A. D., & Reeder, S. B. (2010) · Radiology · doi:10.1148/radiol.09091011 · Cited by 57
Schindera, S. T., Soher, B. J., DeLong, D. M., Dale, B. M., & Merkle, E. M. (2008) · Radiology · doi:10.1148/radiol.2481071069 · Cited by 33
Lipid selective MR imaging and localized 1H spectroscopy of bone marrow during therapy of leukemia.
Schick, F., Einsele, H., Lutz, O., & Claussen, C. D. (1996) · PubMed · Cited by 24
Moriya, S., Miki, Y., Matsuno, Y., et al. (2012) · Acta Radiologica · doi:10.1258/ar.2012.110532 · Cited by 12
Metadata
- Authors
- Del Grande, F., Santini, F., Herzka, D. A., Aro, M. R., Dean, C. W., Gold, G. E., & Carrino, J. A.
- Venue
- RadioGraphics
- Published
- 2014-01
- Volume
- 34
- Issue
- 1
- Pages
- 217-233
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2139880961
- Cited by
- 370
- References
- 30
- FWCI
- 18.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.