Cited by 154Neuroscience and Neural EngineeringConducting polymers and applicationsCardiac pacing and defibrillation studies

The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.

Sputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation

Open access
Slavcheva, E., Vitushinsky, R., Mokwa, W., Schnakenberg, U.·2004·Journal of The Electrochemical Society

Abstract

The paper reports on the deposition of iridium oxide thin films by dc reactive magnetron sputtering and their characterization by surface analysis methods (X-ray diffraction, scanning electron microscopy, atomic force microscopy, and X-ray photoelectron spectroscopy) and electrochemical techniques (cyclic voltammetry, electrochemical impedance spectroscopy, and galvanostatic square waves). The sputtering process was investigated by applying the method of generic curves. An optimal combination of sputtering parameters has been established [40 standard cubic centimeters per minute (sccm) argon/8-12 sccm oxygen/40% effective pump power/100 W dc power/"cold" sputtering] that yields stable microporous amorphous films with a highly extended surface. These films have shown an excellent electrochemical reversibility in physiological saline solution with a "safe" potential range of −1.2 to 1.3 V vs. Ag/AgCl reference electrode, a charge delivery capacity of 90-95 mC/cm 2 , a constant impedance of 70-80 Ω in the frequency range of 100 kHz down to 0.5-1.0 Hz, and a quick response to bipolar current pulses with a safe charge per phase of 2 mC/cm 2 /ph. The demonstrated remarkable electrochemical characteristics combined with their established long-term mechanical stability and corrosion resistance allow one to recommend the use of sputtered iridium oxide films as an ideal electrode material for neural stimulation. © 2004 The Electrochemical Society. All rights reserved.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1149/1.1747881

Cites

81 of 81 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Show all 81 references

Research works printed but not linked: 12

  1. Hoffer, 1974, Soc. Neurosci. Abstr., 4, 300
  2. Z. P. Fang and J. T. Mortimer, inProceedings of the 9th International Annual Conference of the IEEE Biomedical Engineering Society, IEEE, Boston, MA, p. 657 (1987).
  3. J.-U. Meyer, inProceedings of the 11th International Conference on Solid State Sensors and Actuators, Munich, Germany, p. 12, Springer-Verlag, Berlin, June 10-14, 2001.
  4. Humayun, 2001, Tr. Am. Ophth. Soc., 99, 271
  5. Mokwa, 2000, IEEE Trans. Instrum. Meas., 30, 6
  6. Meier, 1986, IEEE Trans. Biomed. Eng., 33, 1146
  7. Frieswijk, 1994, IEEE Trans. Biomed. Eng., 41, 808
  8. P. K. Cambell and K. E. Jones,Materials Science and Technology, Vol. 14, R. W. Cahn, P. Haasen, and E. J. Kramer, Editors, p. 346, VCH Publishers Inc., New York (1992).
  9. L. Ewe, Ph.D. Thesis, Duisburg University, Duisburg, Germany (2000).
  10. E. Slavcheva, L. Ewe, U. Schnakenberg, and W. Mokwa, inProceedings, of the 2nd European Conference on Medical and Biological Engineering, Vienna, IFMBE, Proc. 2002 3(1), p. 785 (2002).
  11. E. Slavcheva, W. Mokwa, and U. Schnakenberg, inProceedings of the 14th Micro-Mechanics Europe Workshop, p. 159, Nov 2-4, 2003, Delft University of Technology, EEMCS, ME/EI, Delft, The Netherlands.
  12. Westwood, 1989, Phys. Thin Films, 14, 1

Cited by

Sorted by citations

Items 101–154 of 154

Metadata

Authors
Slavcheva, E., Vitushinsky, R., Mokwa, W., & Schnakenberg, U.
Affiliations
RWTH Aachen University (DE)
Venue
Journal of The Electrochemical Society
Published
2004
Volume
151
Issue
7
Pages
E226
ISSN
0013-4651 (ISSN-L)
OpenAlex
W2035650671
Cited by
154
References
81
Citations by year
2026: 2 · 2025: 8 · 2024: 8 · 2023: 6 · 2022: 5 · 2021: 5 · 2020: 5 · 2019: 6 · 2018: 6 · 2017: 4 · 2016: 10 · 2015: 5 · 2014: 5 · 2013: 4 · 2012: 7
FWCI
2.78
Type
journal article
Language
en
Open access
Locations
  • Journal of The Electrochemical Society (publishedVersion)
  • RWTH Publications (RWTH Aachen) (submittedVersion)
Funders
Bundesministerium für Bildung und Forschung
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
iridium oxide thin films, charge injection, electrical stimulation, neural stimulation electrodes, reactive DC magnetron sputtering, electrochemical reversibility, sputtering parameter optimization, corrosion resistance, normal saline

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review