The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Sputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation
Open accessAbstract
The paper reports on the deposition of iridium oxide thin films by dc reactive magnetron sputtering and their characterization by surface analysis methods (X-ray diffraction, scanning electron microscopy, atomic force microscopy, and X-ray photoelectron spectroscopy) and electrochemical techniques (cyclic voltammetry, electrochemical impedance spectroscopy, and galvanostatic square waves). The sputtering process was investigated by applying the method of generic curves. An optimal combination of sputtering parameters has been established [40 standard cubic centimeters per minute (sccm) argon/8-12 sccm oxygen/40% effective pump power/100 W dc power/"cold" sputtering] that yields stable microporous amorphous films with a highly extended surface. These films have shown an excellent electrochemical reversibility in physiological saline solution with a "safe" potential range of −1.2 to 1.3 V vs. Ag/AgCl reference electrode, a charge delivery capacity of 90-95 mC/cm 2 , a constant impedance of 70-80 Ω in the frequency range of 100 kHz down to 0.5-1.0 Hz, and a quick response to bipolar current pulses with a safe charge per phase of 2 mC/cm 2 /ph. The demonstrated remarkable electrochemical characteristics combined with their established long-term mechanical stability and corrosion resistance allow one to recommend the use of sputtered iridium oxide films as an ideal electrode material for neural stimulation. © 2004 The Electrochemical Society. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 602
Veraart, C., Raftopoulos, C., Mortimer, J. T., Delbeke, J., Pins, D., Michaux, G., Vanlierde, A., Parrini, S., & Wanet-Defalque, M.-C. (1998) · Brain Research · doi:10.1016/s0006-8993(98)00977-9 · Cited by 418
Anodic Iridium Oxide Films: XPS‐Studies of Oxidation State Changes and
Kötz, R., Neff, H., & Stucki, S. (1984) · Journal of The Electrochemical Society · doi:10.1149/1.2115548 · Cited by 405
Brummer, S. B., & Turner, M. J. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326218 · Cited by 360
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Liu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788468 · Cited by 272
Chronic neural stimulation with thin-film, iridium oxide electrodes
Weiland, J. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846685 · Cited by 265
Batch fabricated thin-film electrodes for stimulation of the central auditory system
Anderson, D. J., Najafi, K., Tanghe, S., Evans, D. A., Levy, K., Hetke, J. F., Xue, X., Zappia, J. J., & Wise, K. D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32101 · Cited by 229
Activated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution
Robblee, L. S., Lefko, J. L., & Brummer, S. B. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119793 · Cited by 228
Flagged first, then by citations
Research works printed but not linked: 12
- Hoffer, 1974, Soc. Neurosci. Abstr., 4, 300
- Z. P. Fang and J. T. Mortimer, inProceedings of the 9th International Annual Conference of the IEEE Biomedical Engineering Society, IEEE, Boston, MA, p. 657 (1987).
- J.-U. Meyer, inProceedings of the 11th International Conference on Solid State Sensors and Actuators, Munich, Germany, p. 12, Springer-Verlag, Berlin, June 10-14, 2001.
- Humayun, 2001, Tr. Am. Ophth. Soc., 99, 271
- Mokwa, 2000, IEEE Trans. Instrum. Meas., 30, 6
- Meier, 1986, IEEE Trans. Biomed. Eng., 33, 1146
- Frieswijk, 1994, IEEE Trans. Biomed. Eng., 41, 808
- P. K. Cambell and K. E. Jones,Materials Science and Technology, Vol. 14, R. W. Cahn, P. Haasen, and E. J. Kramer, Editors, p. 346, VCH Publishers Inc., New York (1992).
- L. Ewe, Ph.D. Thesis, Duisburg University, Duisburg, Germany (2000).
- E. Slavcheva, L. Ewe, U. Schnakenberg, and W. Mokwa, inProceedings, of the 2nd European Conference on Medical and Biological Engineering, Vienna, IFMBE, Proc. 2002 3(1), p. 785 (2002).
- E. Slavcheva, W. Mokwa, and U. Schnakenberg, inProceedings of the 14th Micro-Mechanics Europe Workshop, p. 159, Nov 2-4, 2003, Delft University of Technology, EEMCS, ME/EI, Delft, The Netherlands.
- Westwood, 1989, Phys. Thin Films, 14, 1
Cited by
Sorted by citations
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Rodger, D. C., FONG, A., LI, W., Ameri, H., AHUJA, A., GUTIERREZ, C., Lavrov, I. A., ZHONG, H., MENON, P., & Meng, E. F. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.10.069 · Cited by 327
Boehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 324
Investigations on degradation of the long-term proton exchange membrane water electrolysis stack
Sun, S., Shao, Z., Yu, H., Li, G., & Yi, B. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.05.117 · Cited by 229
Metadata
- Authors
- Slavcheva, E., Vitushinsky, R., Mokwa, W., & Schnakenberg, U.
- Affiliations
- RWTH Aachen University (DE)
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2004
- Volume
- 151
- Issue
- 7
- Pages
- E226
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W2035650671
- Cited by
- 154
- References
- 81
- Citations by year
- 2026: 2 · 2025: 8 · 2024: 8 · 2023: 6 · 2022: 5 · 2021: 5 · 2020: 5 · 2019: 6 · 2018: 6 · 2017: 4 · 2016: 10 · 2015: 5 · 2014: 5 · 2013: 4 · 2012: 7
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of The Electrochemical Society (publishedVersion)
- RWTH Publications (RWTH Aachen) (submittedVersion)
- Funders
- Bundesministerium für Bildung und Forschung
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- iridium oxide thin films, charge injection, electrical stimulation, neural stimulation electrodes, reactive DC magnetron sputtering, electrochemical reversibility, sputtering parameter optimization, corrosion resistance, normal saline
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review