The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Sputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation
Open accessAbstract
The paper reports on the deposition of iridium oxide thin films by dc reactive magnetron sputtering and their characterization by surface analysis methods (X-ray diffraction, scanning electron microscopy, atomic force microscopy, and X-ray photoelectron spectroscopy) and electrochemical techniques (cyclic voltammetry, electrochemical impedance spectroscopy, and galvanostatic square waves). The sputtering process was investigated by applying the method of generic curves. An optimal combination of sputtering parameters has been established [40 standard cubic centimeters per minute (sccm) argon/8-12 sccm oxygen/40% effective pump power/100 W dc power/"cold" sputtering] that yields stable microporous amorphous films with a highly extended surface. These films have shown an excellent electrochemical reversibility in physiological saline solution with a "safe" potential range of −1.2 to 1.3 V vs. Ag/AgCl reference electrode, a charge delivery capacity of 90-95 mC/cm 2 , a constant impedance of 70-80 Ω in the frequency range of 100 kHz down to 0.5-1.0 Hz, and a quick response to bipolar current pulses with a safe charge per phase of 2 mC/cm 2 /ph. The demonstrated remarkable electrochemical characteristics combined with their established long-term mechanical stability and corrosion resistance allow one to recommend the use of sputtered iridium oxide films as an ideal electrode material for neural stimulation. © 2004 The Electrochemical Society. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 602
Veraart, C., Raftopoulos, C., Mortimer, J. T., Delbeke, J., Pins, D., Michaux, G., Vanlierde, A., Parrini, S., & Wanet-Defalque, M.-C. (1998) · Brain Research · doi:10.1016/s0006-8993(98)00977-9 · Cited by 418
Anodic Iridium Oxide Films: XPS‐Studies of Oxidation State Changes and
Kötz, R., Neff, H., & Stucki, S. (1984) · Journal of The Electrochemical Society · doi:10.1149/1.2115548 · Cited by 405
Brummer, S. B., & Turner, M. J. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326218 · Cited by 360
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Liu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788468 · Cited by 272
Chronic neural stimulation with thin-film, iridium oxide electrodes
Weiland, J. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846685 · Cited by 265
Batch fabricated thin-film electrodes for stimulation of the central auditory system
Anderson, D. J., Najafi, K., Tanghe, S., Evans, D. A., Levy, K., Hetke, J. F., Xue, X., Zappia, J. J., & Wise, K. D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32101 · Cited by 229
Activated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution
Robblee, L. S., Lefko, J. L., & Brummer, S. B. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119793 · Cited by 228
Gottesfeld, S., & Srinivasan, S. G. (1978) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(78)80358-1 · Cited by 227
Beebe, X., & Rose, T. L. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.2122 · Cited by 220
Brummer, S. B., & Turner, M. J. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326179 · Cited by 217
Principles Underlying New Methods for Chronic Neural Recording
Stein, R. B., Charles, D., DAVIS, L. A., Jhamandas, J. H., Mannard, A., & Nichols, T. R. (1975) · Canadian Journal of Neurological Sciences / Journal Canadien des Sciences Neurologiques · doi:10.1017/s0317167100020333 · Cited by 211
Selective stimulation of peripheral nerve fibers using dual intrafascicular electrodes
Yoshida, K., & Horch, K. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.243412 · Cited by 208
Brummer, S. B., Robblee, L. S., & Hambrecht, F. T. (1983) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1983.tb31628.x · Cited by 205
Gottesfeld, S., & McIntyre, J. D. E. (1979) · Journal of The Electrochemical Society · doi:10.1149/1.2129131 · Cited by 202
A voltammetric investigation of the charge storage reactions of hydrous iridium oxide layers
Burke, L. D., & Whelan, D. P. (1984) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(84)80159-x · Cited by 199
Moussy, F. G., & Harrison, D. J. (1994) · Analytical Chemistry · doi:10.1021/ac00077a015 · Cited by 146
Biostability of micro‐photodiode arrays for subretinal implantation
Hämmerle, H., Kobuch, K., Kohler, K., Nisch, W., Sachs, H., & Stelzle, M. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00185-5 · Cited by 146
Reflexes induced by nerve stimulation in walking cats with implanted cuff electrodes
Duysens, J., & Stein, R. B. (1978) · Experimental Brain Research · doi:10.1007/bf00239728 · Cited by 141
A model for anodic hydrous oxide growth at iridium
Pickup, P. G., & Birss, V. I. (1987) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(87)88006-3 · Cited by 138
Electrical stimulation of the auditory nerve: direct current measurement in vivo
Huang, C., Shepherd, R. K., P.M. Center, Seligman, P., & Tabor, B. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.752943 · Cited by 114
Electron Microscopy Study of Formation of Thick Oxide Films on Ir and Ru Electrodes
Birss, V. I., Myers, R. D., Angerstein‐Kozlowska, H., & Conway, B. E. (1984) · Journal of The Electrochemical Society · doi:10.1149/1.2115881 · Cited by 107
Valency and Structure of Iridium in Anodic Iridium Oxide Films
Hüppauff, M., & Lengeler, B. (1993) · Journal of The Electrochemical Society · doi:10.1149/1.2056127 · Cited by 101
Hesse, L., Schanze, T., Wilms, M., & Eger, M. (2000) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s004170000197 · Cited by 98
Agnew, W. F., Yuen, T. G. H., & McCreery, D. B. (1983) · Experimental Neurology · doi:10.1016/0014-4886(83)90221-2 · Cited by 96
Muscle recruitment with intrafascicular electrodes
Nannini, N., & Horch, K. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83589 · Cited by 94
Tissue response to potential neuroprosthetic materials implanted subdurally
Yuen, T. G. H., Agnew, W. F., & Bullara, L. A. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90103-7 · Cited by 92
Manipulation of Muscle Force with Various Firing Rate and Recruitment Control Strategies
Zhou, B.-H., Baratta, R. V., & Solomonow, M. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.326037 · Cited by 91
Janders, M., Egert, U., Stelzle, M., & Nisch, W. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.1996.656936 · Cited by 90
Mailley, S. C., Hyland, M., Mailley, P., McLaughlin, J. M., & McAdams, E. T. (2002) · Materials Science and Engineering: C · doi:10.1016/s0928-4931(02)00098-x · Cited by 84
A Technique for Collision Block of Peripheral Nerve: Single Stimulus Analysis
van den Honert, C., & Mortimer, J. T. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324718 · Cited by 82
Evoked cortical potentials after electrical stimulation of the inner retina in rabbits
Walter, P., & Heimann, K. (2000) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s004170050358 · Cited by 80
Blau, A. W., Ziegler, C., Heyer, M., Endres, F., Schwitzgebel, G., Matthies, T., Stieglitz, T., Meyer, J.-U., & Göpel†, W. (1997) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(97)00017-1 · Cited by 79
Kötz, R., Barbero, C. A., & Haas, O. (1990) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(90)87231-8 · Cited by 77
Metallized polymer fibers as leadwires and intrafascicular microelectrodes
McNaughton, T. G., & Horch, K. W. (1996) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)00111-2 · Cited by 76
Burke, L. D., & Whelan, D. P. (1981) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(81)80313-0 · Cited by 75
Electrochromism of Anodic Iridium Oxide Films: III . Anion Mechanism
Beni, G., Rice, C. E., & Shay, J. L. (1980) · Journal of The Electrochemical Society · doi:10.1149/1.2129896 · Cited by 74
Yoshida, K., & Horch, K. (1993) · Annals of Biomedical Engineering · doi:10.1007/bf02368649 · Cited by 69
Solomonow, M., Baratta, R. V., Zhou, B. H., Shoji, H., & D'Ambrosia, R. D. (1987) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1987.325994 · Cited by 69
X-ray absorption in relation to valency of iridium in sputtered iridium oxide films
Pauporté, T., Aberdam, D., Hazemann, J., Faure, R., & Durand, R. (1999) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(99)00058-3 · Cited by 68
Amorphous-nonmetal—to—crystalline-metal transition in electrochromic iridium oxide films
Hackwood, S., Dayem, A. H., & Beni, G. (1982) · Physical review. B, Condensed matter · doi:10.1103/physrevb.26.471 · Cited by 66
Pickup, P. G., & Birss, V. I. (1988) · Journal of The Electrochemical Society · doi:10.1149/1.2095537 · Cited by 65
Reactive sputtering characteristics of silicon in an ArN2 mixture
Okamoto, A., & Serikawa, T. (1986) · Thin Solid Films · doi:10.1016/0040-6090(86)90202-6 · Cited by 64
Morphology and charge capacity of sputtered iridium oxide films
Klein, J. D., Clauson, S. L., & Cogan, S. F. (1989) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.576313 · Cited by 63
The Activation and Deactivation of Iridium Electrodes in Acid Electrolytes
Zerbino, J. O., de Tacconi, N. R., & Arvia, A. J. (1978) · Journal of The Electrochemical Society · doi:10.1149/1.2131661 · Cited by 63
Anodic Evolution of Oxygen on Sputtered Iridium Oxide Films
Hackwood, S., Schiavone, L. M., Dautremont-Smith, W. C., & Beni, G. (1981) · Journal of The Electrochemical Society · doi:10.1149/1.2127293 · Cited by 62
Improved Electrochromic Behavior of Reactively Sputtered Iridium Oxide Films
Schiavone, L. M., Dautremont-Smith, W. C., Beni, G., & Shay, J. L. (1981) · Journal of The Electrochemical Society · doi:10.1149/1.2127632 · Cited by 61
Blue Sputtered Iridium Oxide Films (Blue SIROF's)
Kang, K. S., & Shay, J. L. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119800 · Cited by 58
Michell, D., Rand, D. A. J., & Woods, R. (1977) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(77)80234-9 · Cited by 56
Reactive pulsed laser deposition of iridium oxide thin films
Khakani, M. A. E., & Chaker, M. (1998) · Thin Solid Films · doi:10.1016/s0040-6090(98)00862-1 · Cited by 50
A planar IrO multichannel stimulating electrode for use in neural prostheses
Tanghe, S. J., Najafi, K., & Wise, K. D. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80250-4 · Cited by 47
Chemical analysis of the ionic content of hydrous iridium oxide films
Pickup, P. G., & Birss, V. I. (1988) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(88)80321-8 · Cited by 46
Photodeposition rates of metal from metal alkyls
Krchnavek, R. R., Gilgen, H. H., Chen, J. C., Shaw, P. S., Licata, T. J., & Osgood, R. M. (1987) · Journal of Vacuum Science & Technology B Microelectronics Processing and Phenomena · doi:10.1116/1.583866 · Cited by 45
Characterization of iridium film as a stimulating neural electrode
Lee, I.-S. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00373-8 · Cited by 45
Pinnow, C. U., Kasko, I., Dehm, C., Jobst, B. A., Seibt, M., & Geyer, U. (2001) · Journal of Vacuum Science & Technology B Microelectronics and Nanometer Structures Processing Measurement and Phenomena · doi:10.1116/1.1401750 · Cited by 42
Impedance of hydrated iridium oxide electrodes
Aurian‐Blajeni, B., Beebe, X., Rauh, R. D., & Rose, T. L. (1989) · Electrochimica Acta · doi:10.1016/0013-4686(89)87112-9 · Cited by 41
Action potential classification with dual channel intrafascicular electrodes
McNaughton, T. G., & Horch, K. W. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.301727 · Cited by 41
Anion and water involvement in hydrous Ir oxide redox reactions in acidic solutions
Bock, C., & Birss, V. I. (1999) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(99)00330-7 · Cited by 38
Electronic structure of iridium oxide films formed in neutral phosphate buffer solution
Silva, T. M., Simões, A. M. P., Ferreira, M. G. S., Walls, M. G., & Belo, M. D. C. (1998) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(97)00300-8 · Cited by 38
Volume Changes Induced by the Electrochromic Process in Sputtered Iridium Oxide Films
Hackwood, S., Dautremont-Smith, W. C., Beni, G., Schiavone, L. M., & Shay, J. L. (1981) · Journal of The Electrochemical Society · doi:10.1149/1.2127595 · Cited by 37
Impedance spectroscopy study of electrochromism in sputtered iridium oxide films
Pauporté, T., & Durand, R. (2000) · Journal of Applied Electrochemistry · doi:10.1023/a:1003869328017 · Cited by 36
Influence of deposition conditions on Ir/IrO2 oxygen barrier effectiveness
Pinnow, C. U., Kasko, I., Nagel, N., Poppa, S., Mikolajick, T., Dehm, C., Hösler, W., Bleyl, F., Jahnel, F., Seibt, M., et al. (2002) · Journal of Applied Physics · doi:10.1063/1.1471574 · Cited by 36
Structural and analytical characterization of an iridium oxide thin layer
Bestaoui, N., Prouzet, É., Deniard, P., & Brec, R. (1993) · Thin Solid Films · doi:10.1016/0040-6090(93)90239-l · Cited by 35
Silva, T. M., Rito, J. E., Simões, A. M. P., Ferreira, M. G. S., Belo, M. D. C., & Watkins, K. G. (1998) · Electrochimica Acta · doi:10.1016/s0013-4686(97)00226-0 · Cited by 28
Preparation and Characterization of Iridium Oxide Thin Films Grown by DC Reactive Sputtering
Cho, H., Horii, H., Hwang, C. S., Kim, J.-W., Kang, C. S., Lee, B. T., Lee, S. I., Koh, Y.-B., & Lee, M. Y. (1997) · Japanese Journal of Applied Physics · doi:10.1143/jjap.36.1722 · Cited by 28
Klein, J. D., Clauson, S. L., & Cogan, S. F. (1989) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.1989.1505 · Cited by 28
Reactive-sputter deposition and structure of RuO2 films on sapphire and strontium titanate
Wang, Q., Gladfelter, W. L. L., Evans, D. F., Fan, Y., & Franciosi, A. (1996) · Journal of Vacuum Science & Technology A Vacuum Surfaces and Films · doi:10.1116/1.580382 · Cited by 27
Analysis of single-unit firing patterns in multi-unit intrafascicular recordings
Goodall, E. V., Horch, K. W., McNaughton, T. G., & Lybbert, C. (1993) · Medical & Biological Engineering & Computing · doi:10.1007/bf02458045 · Cited by 25
A Fractally Coated, 1.3 mm2 High Impedance Pacing Electrode
Fröhlig, G., Bolz, A., Strobel, J. L., RUTZ, M., LAWALL, P., SCHWERDT, H., Schaldach, M., & Schieffer, H. J. (1998) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1998.tb00183.x · Cited by 23
Electroactive coating of stimulating electrodes
Fröhlich, R., Rpzany, A., Riedmüller, J., Bolz, A., & Schaldach, M. (1996) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00122006 · Cited by 22
Gielen, F. L. H., & Bergveld, P. (1982) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441854 · Cited by 18
Thin Films. PVD for Microelectronics: Sputter Deposition Applied to Semiconductor Manufacturing.
Powell, R. A., & Rossnagel, S. M. (1999) · Cited by 18
New electrochromism isotherm in anodic iridium oxide films
Beni, G., & Shay, J. L. (1980) · Physical review. B, Condensed matter · doi:10.1103/physrevb.21.364 · Cited by 17
Effect of smooth, porous and fractal surface structure on the properties of an interface
Bolz, A., Fr�hlich, R., Schmidt, K., & Schaldach, M. (1995) · Journal of Materials Science Materials in Medicine · doi:10.1007/bf00134329 · Cited by 16
Micromachined electrodes for retinal prostheses
Hung, A., Zhou, D., Greenberg, R. J., & Judy, J. W. (2003) · International IEEE-EMBS Special Topic Conference on Microtechnologies in Medicine and Biology (MMB) · doi:10.1109/mmb.2002.1002268 · Cited by 16
Simulations of reactive sputtering with constant voltage power supply
Zhu, S., Wang, F., & Wu, W. (1998) · Journal of Applied Physics · doi:10.1063/1.368966 · Cited by 15
Petit, M., & Plichon, V. (1994) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(94)87135-3 · Cited by 15
Physicochemical characterization of sputtered iridium oxide
Aurian‐Blajeni, B., Boucher, M. M., Kimball, A. G., & Robblee, L. S. (1989) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.1989.0440 · Cited by 14
SELECTIVE STIMULATION OF PIG RADIAL NERVE: COMPARISON OF 12-POLAR AND 18-POLAR CUFF ELECTRODES
Schüettler, M., Riso, R. R., Dalmose, A. L., Stefania, D., & Stieglitz, T. (2002) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.2002.47.s1b.696 · Cited by 9
Flagged first, then by citations
Research works printed but not linked: 12
- Hoffer, 1974, Soc. Neurosci. Abstr., 4, 300
- Z. P. Fang and J. T. Mortimer, inProceedings of the 9th International Annual Conference of the IEEE Biomedical Engineering Society, IEEE, Boston, MA, p. 657 (1987).
- J.-U. Meyer, inProceedings of the 11th International Conference on Solid State Sensors and Actuators, Munich, Germany, p. 12, Springer-Verlag, Berlin, June 10-14, 2001.
- Humayun, 2001, Tr. Am. Ophth. Soc., 99, 271
- Mokwa, 2000, IEEE Trans. Instrum. Meas., 30, 6
- Meier, 1986, IEEE Trans. Biomed. Eng., 33, 1146
- Frieswijk, 1994, IEEE Trans. Biomed. Eng., 41, 808
- P. K. Cambell and K. E. Jones,Materials Science and Technology, Vol. 14, R. W. Cahn, P. Haasen, and E. J. Kramer, Editors, p. 346, VCH Publishers Inc., New York (1992).
- L. Ewe, Ph.D. Thesis, Duisburg University, Duisburg, Germany (2000).
- E. Slavcheva, L. Ewe, U. Schnakenberg, and W. Mokwa, inProceedings, of the 2nd European Conference on Medical and Biological Engineering, Vienna, IFMBE, Proc. 2002 3(1), p. 785 (2002).
- E. Slavcheva, W. Mokwa, and U. Schnakenberg, inProceedings of the 14th Micro-Mechanics Europe Workshop, p. 159, Nov 2-4, 2003, Delft University of Technology, EEMCS, ME/EI, Delft, The Netherlands.
- Westwood, 1989, Phys. Thin Films, 14, 1
Cited by
Sorted by citations
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Rodger, D. C., FONG, A., LI, W., Ameri, H., AHUJA, A., GUTIERREZ, C., Lavrov, I. A., ZHONG, H., MENON, P., & Meng, E. F. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.10.069 · Cited by 327
Boehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 324
Investigations on degradation of the long-term proton exchange membrane water electrolysis stack
Sun, S., Shao, Z., Yu, H., Li, G., & Yi, B. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.05.117 · Cited by 229
Metadata
- Authors
- Slavcheva, E., Vitushinsky, R., Mokwa, W., & Schnakenberg, U.
- Affiliations
- RWTH Aachen University (DE)
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2004
- Volume
- 151
- Issue
- 7
- Pages
- E226
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W2035650671
- Cited by
- 154
- References
- 81
- Citations by year
- 2026: 2 · 2025: 8 · 2024: 8 · 2023: 6 · 2022: 5 · 2021: 5 · 2020: 5 · 2019: 6 · 2018: 6 · 2017: 4 · 2016: 10 · 2015: 5 · 2014: 5 · 2013: 4 · 2012: 7
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of The Electrochemical Society (publishedVersion)
- RWTH Publications (RWTH Aachen) (submittedVersion)
- Funders
- Bundesministerium für Bildung und Forschung
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- iridium oxide thin films, charge injection, electrical stimulation, neural stimulation electrodes, reactive DC magnetron sputtering, electrochemical reversibility, sputtering parameter optimization, corrosion resistance, normal saline
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›