The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.
Sputtered Iridium Oxide Films as Charge Injection Material for Functional Electrostimulation
Open accessAbstract
The paper reports on the deposition of iridium oxide thin films by dc reactive magnetron sputtering and their characterization by surface analysis methods (X-ray diffraction, scanning electron microscopy, atomic force microscopy, and X-ray photoelectron spectroscopy) and electrochemical techniques (cyclic voltammetry, electrochemical impedance spectroscopy, and galvanostatic square waves). The sputtering process was investigated by applying the method of generic curves. An optimal combination of sputtering parameters has been established [40 standard cubic centimeters per minute (sccm) argon/8-12 sccm oxygen/40% effective pump power/100 W dc power/"cold" sputtering] that yields stable microporous amorphous films with a highly extended surface. These films have shown an excellent electrochemical reversibility in physiological saline solution with a "safe" potential range of −1.2 to 1.3 V vs. Ag/AgCl reference electrode, a charge delivery capacity of 90-95 mC/cm 2 , a constant impedance of 70-80 Ω in the frequency range of 100 kHz down to 0.5-1.0 Hz, and a quick response to bipolar current pulses with a safe charge per phase of 2 mC/cm 2 /ph. The demonstrated remarkable electrochemical characteristics combined with their established long-term mechanical stability and corrosion resistance allow one to recommend the use of sputtered iridium oxide films as an ideal electrode material for neural stimulation. © 2004 The Electrochemical Society. All rights reserved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Charge density and charge per phase as cofactors in neural injury induced by electrical stimulation
McCreery, D. B., Agnew, W. F., Yuen, T. G. H., & Bullara, L. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102812 · Cited by 708
Visual Perception Elicited by Electrical Stimulation of Retina in Blind Humans
Humayun, M. S. (1996) · Archives of Ophthalmology · doi:10.1001/archopht.1996.01100130038006 · Cited by 602
Veraart, C., Raftopoulos, C., Mortimer, J. T., Delbeke, J., Pins, D., Michaux, G., Vanlierde, A., Parrini, S., & Wanet-Defalque, M.-C. (1998) · Brain Research · doi:10.1016/s0006-8993(98)00977-9 · Cited by 418
Anodic Iridium Oxide Films: XPS‐Studies of Oxidation State Changes and
Kötz, R., Neff, H., & Stucki, S. (1984) · Journal of The Electrochemical Society · doi:10.1149/1.2115548 · Cited by 405
Brummer, S. B., & Turner, M. J. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326218 · Cited by 360
Selective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Liu, X., McCreery, D. B., Carter, R. R., Bullara, L. A., Yuen, T. G. H., & Agnew, W. F. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.788468 · Cited by 272
Chronic neural stimulation with thin-film, iridium oxide electrodes
Weiland, J. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.846685 · Cited by 265
Batch fabricated thin-film electrodes for stimulation of the central auditory system
Anderson, D. J., Najafi, K., Tanghe, S., Evans, D. A., Levy, K., Hetke, J. F., Xue, X., Zappia, J. J., & Wise, K. D. (1989) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.32101 · Cited by 229
Activated Ir: An Electrode Suitable for Reversible Charge Injection in Saline Solution
Robblee, L. S., Lefko, J. L., & Brummer, S. B. (1983) · Journal of The Electrochemical Society · doi:10.1149/1.2119793 · Cited by 228
Flagged first, then by citations
Research works printed but not linked: 12
- Hoffer, 1974, Soc. Neurosci. Abstr., 4, 300
- Z. P. Fang and J. T. Mortimer, inProceedings of the 9th International Annual Conference of the IEEE Biomedical Engineering Society, IEEE, Boston, MA, p. 657 (1987).
- J.-U. Meyer, inProceedings of the 11th International Conference on Solid State Sensors and Actuators, Munich, Germany, p. 12, Springer-Verlag, Berlin, June 10-14, 2001.
- Humayun, 2001, Tr. Am. Ophth. Soc., 99, 271
- Mokwa, 2000, IEEE Trans. Instrum. Meas., 30, 6
- Meier, 1986, IEEE Trans. Biomed. Eng., 33, 1146
- Frieswijk, 1994, IEEE Trans. Biomed. Eng., 41, 808
- P. K. Cambell and K. E. Jones,Materials Science and Technology, Vol. 14, R. W. Cahn, P. Haasen, and E. J. Kramer, Editors, p. 346, VCH Publishers Inc., New York (1992).
- L. Ewe, Ph.D. Thesis, Duisburg University, Duisburg, Germany (2000).
- E. Slavcheva, L. Ewe, U. Schnakenberg, and W. Mokwa, inProceedings, of the 2nd European Conference on Medical and Biological Engineering, Vienna, IFMBE, Proc. 2002 3(1), p. 785 (2002).
- E. Slavcheva, W. Mokwa, and U. Schnakenberg, inProceedings of the 14th Micro-Mechanics Europe Workshop, p. 159, Nov 2-4, 2003, Delft University of Technology, EEMCS, ME/EI, Delft, The Netherlands.
- Westwood, 1989, Phys. Thin Films, 14, 1
Cited by
Sorted by citations
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Nanomaterials for Neural Interfaces
Kotov, N. A., Winter, J. O., Clements, I. P., Jan, E., Timko, B. P., Campidelli, S., Pathak, S., Mazzatenta, A., Lieber, C. M., Prato, M., et al. (2009) · Advanced Materials · doi:10.1002/adma.200801984 · Cited by 504
Rodger, D. C., FONG, A., LI, W., Ameri, H., AHUJA, A., GUTIERREZ, C., Lavrov, I. A., ZHONG, H., MENON, P., & Meng, E. F. (2007) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2007.10.069 · Cited by 327
Boehler, C., Carli, S., Fadiga, L., Stieglitz, T., & Asplund, M. (2020) · Nature Protocols · doi:10.1038/s41596-020-0389-2 · Cited by 324
Investigations on degradation of the long-term proton exchange membrane water electrolysis stack
Sun, S., Shao, Z., Yu, H., Li, G., & Yi, B. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.05.117 · Cited by 229
Negi, S., Bhandari, R., Rieth, L. W., & Solzbacher, F. (2010) · Biomedical Materials · doi:10.1088/1748-6041/5/1/015007 · Cited by 209
Sputtered iridium oxide films as electrocatalysts for water splitting via PEM electrolysis
Slavcheva, E. P., Radev, I., Bliznakov, S., Topalov, G., Andreev, P., & Budevski, E. (2006) · Electrochimica Acta · doi:10.1016/j.electacta.2006.11.005 · Cited by 188
Self-citationSputtered iridium oxide films for neural stimulation electrodes
Cogan, S. F., Ehrlich, J., Plante, T. D., Smirnov, A., Shire, D. B., Gingerich, M. D., & Rizzo, J. F. (2008) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31223 · Cited by 188
Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes
Cogan, S. F., Plante, T. D., & Ehrlich, J. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1404158 · Cited by 138
Toward Bioelectronic Medicine—Neuromodulation of Small Peripheral Nerves Using Flexible Neural Clip
Lee, S., Peh, W. Y. X., Wang, J., Yang, F., Ho, J. S., Thakor, N. V., Yen, S., & Lee, C. (2017) · Advanced Science · doi:10.1002/advs.201700149 · Cited by 96
Tolosa, V. M., Wassum, K. M., Maidment, N. T., & Monbouquette, H. G. (2012) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2012.10.061 · Cited by 87
Petrossians, A., Whalen, J. J., Weiland, J. D., & Mansfeld, F. B. (2011) · Journal of The Electrochemical Society · doi:10.1149/1.3559477 · Cited by 83
Dias, N. S., Carmo, J. P., da Silva, A. F., Mendes, P. M., & Correia, J. H. (2010) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2010.09.016 · Cited by 81
Lycke, R., Kim, R., Zolotavin, P., Montes, J., Sun, Y., Kőszeghy, Á., Altun, E., Noble, B., Yin, R., He, F., et al. (2023) · Cell Reports · doi:10.1016/j.celrep.2023.112554 · Cited by 79
Neural interfaces engineered via micro- and nanostructured coatings
Chen, N., Tian, L., Patil, A. C., Peng, S., Yang, I. H., Thakor, N. V., & Ramakrishna, S. (2017) · Nano Today · doi:10.1016/j.nantod.2017.04.007 · Cited by 74
Selective stimulation and neural recording on peripheral nerves using flexible split ring electrodes
Lee, S., Sheshadri, S., Xiang, Z., Delgado-Martinez, I., Xue, N., Sun, T., Thakor, N. V., Yen, S.-C., & Lee, C. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.09.127 · Cited by 73
Atomic Layer Deposition of Iridium Oxide Thin Films from Ir(acac)3 and Ozone
Hämäläinen, J., Kemell, M., Munnik, F., Kreissig, U., Ritala, M., & Leskelä, M. A. (2008) · Chemistry of Materials · doi:10.1021/cm7030224 · Cited by 68
Medical implants based on microsystems
Mokwa, W. (2007) · Measurement Science and Technology · doi:10.1088/0957-0233/18/5/r01 · Cited by 68
Self-citationHeim, M., Yvert, B., & Kuhn, A. (2011) · Journal of Physiology-Paris · doi:10.1016/j.jphysparis.2011.10.001 · Cited by 72
Slavcheva, E. P., Ganske, G., Topalov, G., Mokwa, W., & Schnakenberg, U. (2009) · Applied Surface Science · doi:10.1016/j.apsusc.2009.02.033 · Cited by 61
Self-citationRF-sputtering of iridium oxide to be used as stimulation material in functional medical implants
Wessling, B., Mokwa, W., & Schnakenberg, U. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/6/s21 · Cited by 58
Self-citationFlexible Nerve Stimulation Electrode With Iridium Oxide Sputtered on Liquid Crystal Polymer
Wang, K., Liu, C.-C., & Durand, D. M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.926691 · Cited by 57
A Parylene Self-Locking Cuff Electrode for Peripheral Nerve Stimulation and Recording
Yu, H., Xiong, W., Zhang, H., Wang, W., & Li, Z. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2333733 · Cited by 56
Minnikanti, S., Skeath, P. R., & Peixoto, N. (2008) · Carbon · doi:10.1016/j.carbon.2008.11.045 · Cited by 56
Intraocular epiretinal prosthesis to restore vision in blind humans
Mokwa, W., Goertz, M., Koch, C., Krisch, I., Trieu, H. K., & Walter, P. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650530 · Cited by 56
Self-citationAmorphous and crystalline IrO2 thin films as potential stimulation electrode coatings
Thanawala, S. S., Baird, R. J., Georgiev, D. G., & Auner, G. W. (2008) · Applied Surface Science · doi:10.1016/j.apsusc.2008.02.054 · Cited by 54
Boron‐Doped Nanocrystalline Diamond Microelectrode Arrays Monitor Cardiac Action Potentials
Maybeck, V., Edgington, R. J., Bongrain, A., Welch, J. O., Scorsone, E., Bergonzo, P., Jackman, R. B., & Offenhäusser, A. (2013) · Advanced Healthcare Materials · doi:10.1002/adhm.201300062 · Cited by 52
Maeng, J., Chakraborty, B., Geramifard, N., Kang, T. H., Rihani, R. T., Joshi‐Imre, A., & Cogan, S. F. (2019) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34442 · Cited by 51
Characterization of iridium oxide thin films deposited by pulsed-direct-current reactive sputtering
Thanawala, S. S., Georgiev, D. G., Baird, R. J., & Auner, G. W. (2007) · Thin Solid Films · doi:10.1016/j.tsf.2007.02.090 · Cited by 51
Neuronal cell growth on iridium oxide
Göbbels, K., Kuenzel, T., van Ooyen, A., Baumgärtner, W., Schnakenberg, U., & Bräunig, P. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.10.029 · Cited by 50
Self-citationZhou, H., Li, G., Sun, X.-N., Zhu, Z.-H., Jin, Q., Zhao, J., & Ren, Q. (2009) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2008.2011122 · Cited by 50
Effect of sputtering pressure on pulsed-DC sputtered iridium oxide films
Negi, S., Bhandari, R., Rieth, L. W., & Solzbacher, F. (2008) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2008.11.015 · Cited by 49
Note: Characterization of electrode materials for dielectric spectroscopy
Malleo, D., Nevill, J. T., van Ooyen, A., Schnakenberg, U., Lee, L. P., & Morgan, H. (2010) · Review of Scientific Instruments · doi:10.1063/1.3284516 · Cited by 49
Self-citationChemical vapour deposition of Ir-based coatings: chemistry, processes and applications
Vasilyev, V. Y., Morozova, N. B., Basova, T. V., Igumenov, I. K., & Hassan, A. M. (2015) · RSC Advances · doi:10.1039/c5ra03566j · Cited by 48
Photodiode Circuits for Retinal Prostheses
Loudin, J., Cogan, S. F., Mathieson, K., Sher, A., & Palanker, D. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2144980 · Cited by 46
Eick, S. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.016.2009 · Cited by 46
Chen, Y.-M., Chung, T.-W., Wu, P., & Chen, P. (2016) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2016.09.064 · Cited by 45
Lee, S. H., Jung, J. H., Chae, Y. M., Suh, J. F., & Kang, J. Y. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/3/035015 · Cited by 44
Leal, J., Jedrusik, N., Shaner, S. W., Boehler, C., & Asplund, M. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.120949 · Cited by 42
Electrical Stimulation of Cells: Drivers, Technology, and Effects
Kadan-Jamal, K., Wronowski, F., Jin, A. T., Naegele, T. E., Montes, V. R., Tao, X., Dominguez‐Alfaro, A., Lee, C., & Malliaras, G. G. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00468 · Cited by 39
Reactively Sputtered Iridium Oxide
Wessling, B., Besmehn, A., Mokwa, W., & Schnakenberg, U. (2007) · Journal of The Electrochemical Society · doi:10.1149/1.2713691 · Cited by 38
Self-citationSputtered Ir Films Evaluated for Electrochemical Performance I. Experimental Results
Wessling, B., Mokwa, W., & Schnakenberg, U. (2008) · Journal of The Electrochemical Society · doi:10.1149/1.2844805 · Cited by 36
Self-citationMEMS technologies for epiretinal stimulation of the retina
Mokwa, W. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/9/002 · Cited by 36
Self-citationEbonex supported iridium as anode catalyst for PEM water electrolysis
Slavcheva, E. P., Borisov, G. R., Lefterova, E., Petkucheva, E., & Boshnakova, I. (2015) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2015.03.005 · Cited by 35
Self-citationIridium Metal Thin Films and Patterned IrO2 Nanowires Deposited Using Iridium(I) Carbonyl Precursors
Chen, Y. ‐., Hsu, C. ‐., Song, Y., Chi, Y., Carty, A. J., Peng, S., & LEE, G. ‐. (2006) · Chemical Vapor Deposition · doi:10.1002/cvde.200606491 · Cited by 34
Sol-Gel Deposition of Iridium Oxide for Biomedical Micro-Devices
Nguyen, C., Rao, S., Yang, X., Dubey, S., Mays, J., Cao, H., & Chiao, J. ‐. (2015) · Sensors · doi:10.3390/s150204212 · Cited by 32
Deku, F., Joshi‐Imre, A., Mërtiri, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0401809jes · Cited by 31
Petkucheva, E., Borisov, G. R., Lefterova, E., Heiss, J., Schnakenberg, U., & Slavcheva, E. P. (2018) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2018.01.188 · Cited by 29
Self-citationWang, B., Wen, X., Cao, Y. F., Huang, S., Lam, H. A., Liu, T. “., Chung, P., Monbouquette, H. G., Chiou, P.-Y. E., & Maidment, N. T. (2020) · Lab on a Chip · doi:10.1039/d0lc00021c · Cited by 29
Sputtered electrocatalysts for PEM electrochemical energy converters
Slavcheva, E. P., Radev, I., Topalov, G., & Budevski, E. (2007) · Electrochimica Acta · doi:10.1016/j.electacta.2007.03.015 · Cited by 29
Self-citationKang, X., Liu, J., Tian, H., Yang, B. T., NuLi, Y., & Yang, C. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.11.050 · Cited by 27
Deposition of sputtered iridium oxide—Influence of oxygen flow in the reactor on the film properties
Slavcheva, E. P., Schnakenberg, U., & Mokwa, W. (2006) · Applied Surface Science · doi:10.1016/j.apsusc.2006.03.073 · Cited by 28
Self-citationAmini, S., Seche, W., May, N., Choi, H., Tavousi, P., & Shahbazmohamadi, S. (2022) · Scientific Reports · doi:10.1038/s41598-022-18161-4 · Cited by 28
Production processes for a flexible retina implant (Eurosensors XVIII, Session C6.6)
Hungar, K., Görtz, M., Slavcheva, E. P., Spanier, G., Weidig, C., & Mokwa, W. (2005) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2005.03.061 · Cited by 27
Self-citationMontes, V. R., Gehlen, J., Lück, S., Mokwa, W., Müller, F. U., Walter, P., & Offenhäusser, A. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00367 · Cited by 26
Self-citationA neural cell culture study on thin film electrode materials
Thanawala, S. S., Palyvoda, O., Georgiev, D. G., Khan, S. P., Alhomoudi, I. A., Newaz, G. M., & Auner, G. W. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-3054-1 · Cited by 26
Negi, S., Bhandari, R., & Solzbacher, F. (2012) · Journal of Sensor Technology · doi:10.4236/jst.2012.23020 · Cited by 26
Kwon, I. S., Kim, Y. J., Klosterman, L., Forssell, M., Fedder, G. K., & Bettinger, C. J. (2016) · Journal of Materials Chemistry B · doi:10.1039/c5tb02618k · Cited by 25
Guide to Leveraging Conducting Polymers and Hydrogels for Direct Current Stimulation
Leal, J., Shaner, S. W., Matter, L., Böhler, C., & Asplund, M. (2023) · Advanced Materials Interfaces · doi:10.1002/admi.202202041 · Cited by 24
A flexible device for ocular iontophoretic drug delivery
Zhang, Y., Chen, Y., Yu, X., Qi, Y., Chen, Y., Liu, Y., Hu, Y., & Li, Z. (2016) · Biomicrofluidics · doi:10.1063/1.4942516 · Cited by 24
Sputtered platinum–iridium layers as electrode material for functional electrostimulation
Ganske, G., Slavcheva, E. P., van Ooyen, A., Mokwa, W., & Schnakenberg, U. (2011) · Thin Solid Films · doi:10.1016/j.tsf.2011.01.344 · Cited by 24
Self-citationRecording nerve signals in canine sciatic nerves with a flexible penetrating microelectrode array
Byun, D., Cho, S.-J., Lee, B. H., Min, J., Lee, J.-H., & Kim, S. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa7493 · Cited by 23
pH dependence of noble metals dissolution: Iridium
Zlatar, M., Escalera‐López, D., Simon, C., Martos, V. B., Stojanovski, K., & Cherevko, S. (2024) · Electrochimica Acta · doi:10.1016/j.electacta.2024.145450 · Cited by 24
Nanostructured Iridium Oxide: State of the Art
Scarpelli, F., Godbert, N., Crispini, A., & Aiello, I. (2022) · Inorganics · doi:10.3390/inorganics10080115 · Cited by 23
Comstock, D. J., Christensen, S. T., Elam, J. W., Pellin, M. J., & Hersam, M. C. (2010) · Electrochemistry Communications · doi:10.1016/j.elecom.2010.08.029 · Cited by 23
A 2.4-GHz Low-Power/Low-Voltage Wireless Plug-and-Play Module for EEG Applications
Carmo, J. P., Dias, N. S., Silva, H. R., Mendes, P. M., Couto, C., & Correia, J. H. (2007) · IEEE Sensors Journal · doi:10.1109/jsen.2007.908238 · Cited by 23
Hu, Z., Zhou, D. M., Greenberg, R. J., & Thundat, T. G. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2005.10.030 · Cited by 22
A 3D flexible microelectrode array for subretinal stimulation
Seo, H. W., Kim, N., Ahn, J., Cha, S., Goo, Y. S., & Kim, S. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab36ab · Cited by 22
Kang, X., Liu, J., Tian, H., Yang, B. T., NuLi, Y., & Yang, C. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/2/025015 · Cited by 19
Chung, T.-W., Hsieh, M.-T., Tso, K.-C., Kuo, S.-H., Cheng, C.-T., Yu, J., Chan, T., Wu, P., & Chen, P. (2020) · Ceramics International · doi:10.1016/j.ceramint.2020.04.177 · Cited by 19
Iridium oxide deposited by pulsed dc-sputtering for stimulation electrodes
van Ooyen, A., Topalov, G., Ganske, G., Mokwa, W., & Schnakenberg, U. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/7/074009 · Cited by 19
Self-citationLaube, T., Brockmann, C., Roessler, G. F., Walter, P., Krueger, C. E., Goertz, M., Klauke, S., & Bornfeld, N. (2011) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-011-1756-z · Cited by 18
Iridium oxide reference electrodes for neurochemical sensing with MEMS microelectrode arrays
Franklin, R. K., Johnson, M. D., Scottt, K. A., Shim, J. H., Nam, H., Kipket, D. R., & Brown, R. B. (2005) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2005.1597971 · Cited by 18
Flexible 3D carbon nanotubes cuff electrodes as a peripheral nerve interface
Tian, P. W., Yi, W., Chen, C., Hu, J., Qi, J., Zhang, B., & Cheng, M. M. (2018) · Biomedical Microdevices · doi:10.1007/s10544-018-0268-6 · Cited by 17
Noda, T., Sasagawa, K., Tokuda, T., Terasawa, Y., Tashiro, H., Kanda, H., Fujikado, T., & Ohta, J. (2014) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2014.03.001 · Cited by 16
An ocular iontophoretic device using PEDOT electrode for local drug delivery
Zhang, Y., Chen, Y., Qi, Y., Huang, D., Yang, M. R., Yu, X., Hu, Y., & Li, Z. (2016) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2016.01.057 · Cited by 16
Nanostructured Antireflective Iridium Oxide Coating for Water Oxidation
Baker, D. R., Graziano, M. B., & Hanrahan, B. (2018) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.8b03874 · Cited by 15
3D conductive material strategies for modulating and monitoring cells
Li, X., Mao, M., Han, K., Yao, C., Gu, B., He, J., & Li, D. (2022) · Progress in Materials Science · doi:10.1016/j.pmatsci.2022.101041 · Cited by 14
On the growth and water oxidation stability of hydrous iridium oxide
Zlatar, M., Xie, X., Franke, C., Hrbek, T., Krtouš, Z., Li, T., Khalakhan, I., & Cherevko, S. (2025) · EES Catalysis · doi:10.1039/d4ey00268g · Cited by 14
Bimetallic Pt,Ir-containing coatings formed by MOCVD for medical applications
Dorovskikh, S. I., Vikulova, E. S., Kal’nyi, D. B., Shubin, Y. V., Asanov, I., Maximovskiy, E. A., Gutakovskii, A. K., Morozova, N. B., & Basova, T. V. (2019) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-019-6275-1 · Cited by 13
Zhou, C., Tian, Y., Li, G., Ye, Y., Gao, L., Li, J., Liu, Z., Su, H., Lu, Y., Li, M., et al. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-024-00691-8 · Cited by 13
Chernov, M. M., Chen, G., Torre-Healy, L. A., Friedman, R. M., & Roe, A. W. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.01.018 · Cited by 13
Ghane-Motlagh, B., Choueib, M., Mesgar, A. H., Hasanuzzaman, M., & Sawan, M. (2016) · Micromachines · doi:10.3390/mi7090163 · Cited by 13
In vitro recording of neural activity using carbon nanosheet microelectrodes
Collaert, N., López, C. M., Cott, D. J., Cools, J., Braeken, D., & Volder, M. F. L. D. (2013) · Carbon · doi:10.1016/j.carbon.2013.09.079 · Cited by 13
Fabrication of iridium oxide neural electrodes at the wafer level
Zhang, H., Pei, W., Zhao, S., Yang, X., Liu, R., Liu, Y., Wu, X. M., Guo, D., Gui, Q., Guo, X., et al. (2016) · Science China Technological Sciences · doi:10.1007/s11431-016-6099-x · Cited by 12
Geramifard, N., Chakraborty, B., Dousti, B., Lee, G. S., & Maeng, J. (2022) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ac6a80 · Cited by 12
Chung, T.-W., Huang, C., Chen, P., Noda, T., Tokuda, T., & Ohta, J. (2018) · Coatings · doi:10.3390/coatings8120420 · Cited by 12
An evaluation of extracellular MEA versus optogenetic stimulation of cortical neurons
Maybeck, V., Schnitker, J., Li, W., Heuschkel, M. O., & Offenhäusser, A. (2016) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/2/5/055017 · Cited by 12
Walter, P., & Mokwa, W. (2005) · Der Ophthalmologe · doi:10.1007/s00347-005-1250-2 · Cited by 12
Self-citationRapid and Low Cost Manufacturing of Cuff Electrodes
Flavin, M. T., Paul, M. A., Lim, A. S., Abdul‐Hamed, S., Lissandrello, C. A., Ajemian, R., Lin, S. J., & Han, J. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.628778 · Cited by 11
Materials for implantable systems
Neves, H. P. (2013) · Elsevier eBooks · doi:10.1533/9780857096289.1.3 · Cited by 15
Low-Impedance PEDOT:PSS MEA Integrated in a Stretchable Organ-on-Chip Device
Waafi, A. K., Gaio, N., Quirós-Solano, W. F., Dijkstra, P., Sarro, P. M., & Dekker, R. H. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2946854 · Cited by 10
Flexible multi-electrode array with integrated bendable CMOS-chip for implantable systems
Winkin, N., & Mokwa, W. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346815 · Cited by 10
Self-citationRuckodanov, D. A., Maidment, N. T., & Monbouquette, H. G. (2025) · ACS Chemical Neuroscience · doi:10.1021/acschemneuro.4c00658 · Cited by 9
Magnetron sputtered iridium oxide as anode catalyst for PEM hydrogen generation
Slavcheva, E. P. (2011) · Macedonian Journal of Chemistry and Chemical Engineering · doi:10.20450/mjcce.2011.69 · Cited by 9
Self-citationWang, H.-Y., Hsieh, Y.-C., Tso, K.-C., Chang, C., Cheng, Y., Wu, P., & Lee, J. (2019) · Electrochimica Acta · doi:10.1016/j.electacta.2019.05.006 · Cited by 9
Liu, D.-Q., Yu, S.-H., Son, S.-W., & Joo, S. (2008) · Electrochemical and Solid-State Letters · doi:10.1149/1.2977787 · Cited by 9
Blagojevic, A., Seche, W., Choi, H., Davis, S. L., Elyahoodayan, S., Caputo, G. A., Lowe, T. C., Tavousi, P., Shahbazmohamadi, S., & Amini, S. (2024) · Advanced Materials Interfaces · doi:10.1002/admi.202400017 · Cited by 8
Amini, S., Choi, H., Seche, W., Blagojevic, A., May, N., Lefler, B. M., Davis, S. L., Elyahoodayan, S., Tavousi, P., May, S. J., et al. (2024) · Microsystems & Nanoengineering · doi:10.1038/s41378-024-00754-w · Cited by 8
Simulations and study of electrochemical hydrogen energy conversion in EasyTest Cell
Radev, I., Slavcheva, E. P., Budevski, E., & Schnakenberg, U. (2008) · Electrochimica Acta · doi:10.1016/j.electacta.2008.09.006 · Cited by 8
Self-citation
Metadata
- Authors
- Slavcheva, E., Vitushinsky, R., Mokwa, W., & Schnakenberg, U.
- Affiliations
- RWTH Aachen University (DE)
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2004
- Volume
- 151
- Issue
- 7
- Pages
- E226
- ISSN
- 0013-4651 (ISSN-L)
- OpenAlex
- W2035650671
- Cited by
- 154
- References
- 81
- Citations by year
- 2026: 2 · 2025: 8 · 2024: 8 · 2023: 6 · 2022: 5 · 2021: 5 · 2020: 5 · 2019: 6 · 2018: 6 · 2017: 4 · 2016: 10 · 2015: 5 · 2014: 5 · 2013: 4 · 2012: 7
- FWCI
- 2.78
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of The Electrochemical Society (publishedVersion)
- RWTH Publications (RWTH Aachen) (submittedVersion)
- Funders
- Bundesministerium für Bildung und Forschung
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Materials Science › Polymers and Plastics › Conducting polymers and applications
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- iridium oxide thin films, charge injection, electrical stimulation, neural stimulation electrodes, reactive DC magnetron sputtering, electrochemical reversibility, sputtering parameter optimization, corrosion resistance, normal saline
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review