The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Impact of Intermittent Operation on Lifetime and Performance of a PEM Water Electrolyzer
Open accessAbstract
The aim of this study is to provide a better understanding of performance degrading mechanisms occurring when a proton exchange membrane water electrolyzer (PEM-WE) is coupled with renewable energies, where times of operation and idle periods alternate. An accelerated stress test (AST) is proposed, mimicking a fluctuating power supply by operating the electrolyzer cell between high (3 A cm −2 geo ) and low current densities (0.1 A cm −2 geo ), alternating with idle periods during which no current is supplied and the cell rests at open circuit voltage (OCV). Polarization curves, periodically recorded during the OCV-AST, reveal an initial increase in activity (≈50 mV after 10 cycles) followed by a significant decrease in performance during prolonged OCV cycling due to an increasing high frequency resistance (HFR) (≈1.6-fold after 718 cycles). These performance changes can clearly be related to the OCV periods, since they are not observed in a reference experiment where the OCV period is replaced by a potential hold at 1.3 V. The origin of the phenomena, which are responsible for the initial performance gain as well as the subsequent decay are analyzed via detailed electrochemical and physical characterization of the MEAs, and an operating strategy to prevent performance degradation is proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comprehensive review on PEM water electrolysis
Carmo, M., Fritz, D. L., Mergel, J., & Stolten, D. (2013) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2013.01.151 · Cited by 5,492
Buttler, A., & Spliethoff, H. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.003 · Cited by 2,510
Instability of Pt∕C Electrocatalysts in Proton Exchange Membrane Fuel Cells
Ferreira, P. J., la O’, G. J., Shao-Horn, Y., Morgan, D., Makharia, R., Kocha, S., & Gasteiger, H. A. (2005) · Journal of The Electrochemical Society · doi:10.1149/1.2050347 · Cited by 1,491
Self-citationPEM electrolysis for production of hydrogen from renewable energy sources
Barbir, F. (2005) · Solar Energy · doi:10.1016/j.solener.2004.09.003 · Cited by 1,112
Advanced materials for improved PEMFC performance and life
Curtin, D. E., Lousenberg, R. D., Henry, T. J., Tangeman, P. C., & Tisack, M. E. (2004) · Journal of Power Sources · doi:10.1016/j.jpowsour.2004.01.023 · Cited by 786
05/02653 PEM electrolysis for production of hydrogen from renewable energy sources
(2005) · Fuel and Energy Abstracts · doi:10.1016/s0140-6701(05)83151-0 · Cited by 655
Critical Review—Identifying Critical Gaps for Polymer Electrolyte Water Electrolysis Development
Babic, U., Suermann, M., Büchi, F. N., Gubler, L., & Schmidt, T. J. (2017) · Journal of The Electrochemical Society · doi:10.1149/2.1441704jes · Cited by 564
Durst, J., Simon, C., Hasché, F., & Gasteiger, H. A. (2015) · Journal of The Electrochemical Society · doi:10.1149/2.0981501jes · Cited by 550
Self-citationAnalysis of Voltage Losses in PEM Water Electrolyzers with Low Platinum Group Metal Loadings
Bernt, M., Siebel, A., & Gasteiger, H. A. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0641805jes · Cited by 462
Self-citationElectrocatalysis in water electrolysis with solid polymer electrolyte
Rasten, E., Hagen, G., & Tunold, R. (2003) · Electrochimica Acta · doi:10.1016/j.electacta.2003.04.001 · Cited by 420
Influence of Ionomer Content in IrO2/TiO2Electrodes on PEM Water Electrolyzer Performance
Bernt, M., & Gasteiger, H. A. (2016) · Journal of The Electrochemical Society · doi:10.1149/2.0231611jes · Cited by 416
Self-citationAn analysis of degradation phenomena in polymer electrolyte membrane water electrolysis
Rakousky, C., Reimer, U., Wippermann, K., Carmo, M., Lueke, W., & Stolten, D. (2016) · Journal of Power Sources · doi:10.1016/j.jpowsour.2016.06.082 · Cited by 397
A comprehensive review on coupling different types of electrolyzer to renewable energy sources
Mohammadi, A., & Mehrpooya, M. (2018) · Energy · doi:10.1016/j.energy.2018.06.073 · Cited by 339
Cherevko, S., Geiger, S., Kasian, O., Mingers, A., & Mayrhofer, K. J. J. (2016) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2016.05.015 · Cited by 332
Rakousky, C., Reimer, U., Wippermann, K., Kuhri, S., Carmo, M., Lueke, W., & Stolten, D. (2017) · Journal of Power Sources · doi:10.1016/j.jpowsour.2016.11.118 · Cited by 318
Direct coupling of an electrolyser to a solar PV system for generating hydrogen
Clarke, R. E., Giddey, S. S., Ciacchi, F. T., Badwal, S. P. S., Paul, B., & Andrews, J. (2009) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2009.01.053 · Cited by 297
Oxygen evolution activity and stability of iridium in acidic media. Part 1. – Metallic iridium
Cherevko, S., Geiger, S., Kasian, O., Mingers, A., & Mayrhofer, K. J. J. (2016) · Journal of Electroanalytical Chemistry · doi:10.1016/j.jelechem.2016.04.033 · Cited by 272
Aricò, A. S., Siracusano, S., Briguglio, N., Baglio, V., Di Blasi, A., & Antonucci, V. (2013) · Journal of Applied Electrochemistry · doi:10.1007/s10800-012-0490-5 · Cited by 270
Reier, T., Teschner, D., Lunkenbein, T., Bergmann, A., Selve, S., Kraehnert, R., Schlögl, R., & Strasser, P. (2014) · Journal of The Electrochemical Society · doi:10.1149/2.0411409jes · Cited by 263
Geiger, S., Kasian, O., Shrestha, B. R., Mingers, A. M., Mayrhofer, K. J. J., & Cherevko, S. (2016) · Journal of The Electrochemical Society · doi:10.1149/2.0181611jes · Cited by 239
Investigations on degradation of the long-term proton exchange membrane water electrolysis stack
Sun, S., Shao, Z., Yu, H., Li, G., & Yi, B. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.05.117 · Cited by 227
Grigoriev, S. A., Dzhus, K. A., Bessarabov, D. G., & Millet, P. (2014) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2014.05.043 · Cited by 205
Siracusano, S., Baglio, V., Grigoriev, S. A., Merlo, L., Fateev, V. N., & Aricò, A. S. (2017) · Journal of Power Sources · doi:10.1016/j.jpowsour.2017.09.020 · Cited by 193
Woods, R. (1974) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(74)80229-9 · Cited by 188
Properties of thermally prepared iridium dioxide electrodes
Ardizzone, S., Carugati, A., & Trasatti, S. (1981) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(81)80437-8 · Cited by 180
Effect of Hydrogen and Oxygen Partial Pressure on Pt Precipitation within the Membrane of PEMFCs
Zhang, J., Litteer, B. A., Gu, W., Liu, H., & Gasteiger, H. A. (2007) · Journal of The Electrochemical Society · doi:10.1149/1.2764240 · Cited by 180
Self-citationLandesfeind, J., Ebner, M., Eldiven, A., Wood, V., & Gasteiger, H. A. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0231803jes · Cited by 170
Self-citationPEM water electrolysers: evidence for membrane failure in 100kW demonstration plants
Stucki, S., Scherer, G. G., Schlagowski, S., & Fischer, E. (1998) · Journal of Applied Electrochemistry · doi:10.1023/a:1003477305336 · Cited by 168
Degradation issues of PEM electrolysis MEAs
Siracusano, S., van Dijk, N., Backhouse, R., Merlo, L., Baglio, V., & Aricò, A. S. (2018) · Renewable Energy · doi:10.1016/j.renene.2018.02.024 · Cited by 156
A model for anodic hydrous oxide growth at iridium
Pickup, P. G., & Birss, V. I. (1987) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(87)88006-3 · Cited by 137
Operational characteristics of high-pressure, high-efficiency water-hydrogen-electrolysis
Schug, C. A. (1998) · International Journal of Hydrogen Energy · doi:10.1016/s0360-3199(97)00139-0 · Cited by 83
Transient electrolyser response in a renewable-regenerative energy system
Bergen, A., Pitt, L., Rowe, A. M., Wild, P. M., & Djilali, N. (2008) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2008.10.007 · Cited by 81
Grigoriev, S. V., Bessarabov, D., & Fateev, V. N. (2017) · Russian Journal of Electrochemistry · doi:10.1134/s1023193517030065 · Cited by 60
(Plenary) Challenges in Going from Laboratory to Megawatt Scale PEM Electrolysis
Danilovic, N., Ayers, K. E., Capuano, C. B., Renner, J., Wiles, L., & Pertoso, M. (2016) · ECS Transactions · doi:10.1149/07514.0395ecst · Cited by 47
Okada, T. (2010) · Wiley eBooks · doi:10.1002/9780470974001.f303054 · Cited by 39
Durability and Degradation Issues in PEM Electrolysis Cells and its Components
Price, E. (2017) · Johnson Matthey Technology Review · doi:10.1595/205651317x693732 · Cited by 29
Cited by
An overview of water electrolysis technologies for green hydrogen production
Shiva Kumar, S., & Lim, H. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.10.127 · Cited by 1,526
Water electrolysers with closed and open electrochemical systems
Lagadec, M. F., & Grimaud, A. (2020) · Nature Materials · doi:10.1038/s41563-020-0788-3 · Cited by 749
Recent advances in proton exchange membrane water electrolysis
Liu, R.-T., Xu, Z.-L., Li, F.-M., Chen, F.-Y., Yu, J.-Y., Yan, Y., Chen, Y., & Xia, B. Y. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00681b · Cited by 701
Influence of renewable energy power fluctuations on water electrolysis for green hydrogen production
Kojima, H., Nagasawa, K., Todoroki, N., Ito, Y., Matsui, T., & Nakajima, R. (2023) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2022.11.018 · Cited by 520
Wang, C. R., Stansberry, J. M., Mukundan, R., Chang, H.-M. J., Kulkarni, D., Park, A. M., Plymill, A. B., Firas, N. M., Liu, C. P., Lang, J. T., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00904 · Cited by 402
Metadata
- Authors
- Weiß, A., Siebel, A., Bernt, M., Shen, T.-H., Tileli, V., & Gasteiger, H. A.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2019
- Volume
- 166
- Issue
- 8
- Pages
- F487-F497
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2942832255
- Cited by
- 413
- References
- 36
- FWCI
- 8.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.