Impact of Intermittent Operation on Lifetime and Performance of a PEM Water Electrolyzer
Open accessAbstract
The aim of this study is to provide a better understanding of performance degrading mechanisms occurring when a proton exchange membrane water electrolyzer (PEM-WE) is coupled with renewable energies, where times of operation and idle periods alternate. An accelerated stress test (AST) is proposed, mimicking a fluctuating power supply by operating the electrolyzer cell between high (3 A cm −2 geo ) and low current densities (0.1 A cm −2 geo ), alternating with idle periods during which no current is supplied and the cell rests at open circuit voltage (OCV). Polarization curves, periodically recorded during the OCV-AST, reveal an initial increase in activity (≈50 mV after 10 cycles) followed by a significant decrease in performance during prolonged OCV cycling due to an increasing high frequency resistance (HFR) (≈1.6-fold after 718 cycles). These performance changes can clearly be related to the OCV periods, since they are not observed in a reference experiment where the OCV period is replaced by a potential hold at 1.3 V. The origin of the phenomena, which are responsible for the initial performance gain as well as the subsequent decay are analyzed via detailed electrochemical and physical characterization of the MEAs, and an operating strategy to prevent performance degradation is proposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A comprehensive review on PEM water electrolysis
Carmo, M., Fritz, D. L., Mergel, J., & Stolten, D. (2013) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2013.01.151 · Cited by 5,492
Buttler, A., & Spliethoff, H. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.09.003 · Cited by 2,510
Instability of Pt∕C Electrocatalysts in Proton Exchange Membrane Fuel Cells
Ferreira, P. J., la O’, G. J., Shao-Horn, Y., Morgan, D., Makharia, R., Kocha, S., & Gasteiger, H. A. (2005) · Journal of The Electrochemical Society · doi:10.1149/1.2050347 · Cited by 1,491
Self-citationPEM electrolysis for production of hydrogen from renewable energy sources
Barbir, F. (2005) · Solar Energy · doi:10.1016/j.solener.2004.09.003 · Cited by 1,112
Advanced materials for improved PEMFC performance and life
Curtin, D. E., Lousenberg, R. D., Henry, T. J., Tangeman, P. C., & Tisack, M. E. (2004) · Journal of Power Sources · doi:10.1016/j.jpowsour.2004.01.023 · Cited by 786
05/02653 PEM electrolysis for production of hydrogen from renewable energy sources
(2005) · Fuel and Energy Abstracts · doi:10.1016/s0140-6701(05)83151-0 · Cited by 655
Critical Review—Identifying Critical Gaps for Polymer Electrolyte Water Electrolysis Development
Babic, U., Suermann, M., Büchi, F. N., Gubler, L., & Schmidt, T. J. (2017) · Journal of The Electrochemical Society · doi:10.1149/2.1441704jes · Cited by 564
Durst, J., Simon, C., Hasché, F., & Gasteiger, H. A. (2015) · Journal of The Electrochemical Society · doi:10.1149/2.0981501jes · Cited by 550
Self-citationAnalysis of Voltage Losses in PEM Water Electrolyzers with Low Platinum Group Metal Loadings
Bernt, M., Siebel, A., & Gasteiger, H. A. (2018) · Journal of The Electrochemical Society · doi:10.1149/2.0641805jes · Cited by 462
Self-citationElectrocatalysis in water electrolysis with solid polymer electrolyte
Rasten, E., Hagen, G., & Tunold, R. (2003) · Electrochimica Acta · doi:10.1016/j.electacta.2003.04.001 · Cited by 420
Cited by
An overview of water electrolysis technologies for green hydrogen production
Shiva Kumar, S., & Lim, H. (2022) · Energy Reports · doi:10.1016/j.egyr.2022.10.127 · Cited by 1,526
Water electrolysers with closed and open electrochemical systems
Lagadec, M. F., & Grimaud, A. (2020) · Nature Materials · doi:10.1038/s41563-020-0788-3 · Cited by 749
Recent advances in proton exchange membrane water electrolysis
Liu, R.-T., Xu, Z.-L., Li, F.-M., Chen, F.-Y., Yu, J.-Y., Yan, Y., Chen, Y., & Xia, B. Y. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00681b · Cited by 701
Influence of renewable energy power fluctuations on water electrolysis for green hydrogen production
Kojima, H., Nagasawa, K., Todoroki, N., Ito, Y., Matsui, T., & Nakajima, R. (2023) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2022.11.018 · Cited by 520
Wang, C. R., Stansberry, J. M., Mukundan, R., Chang, H.-M. J., Kulkarni, D., Park, A. M., Plymill, A. B., Firas, N. M., Liu, C. P., Lang, J. T., et al. (2025) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00904 · Cited by 402
Renewable methanol production from green hydrogen and captured CO2: A techno-economic assessment
Sollai, S., Porcu, A., Tola, V., Ferrara, F., & Pettinau, A. (2023) · Journal of CO2 Utilization · doi:10.1016/j.jcou.2022.102345 · Cited by 379
A non-precious metal hydrogen catalyst in a commercial polymer electrolyte membrane electrolyser
King, L. A., Hubert, M. A., Capuano, C., Manco, J., Danilovic, N., Valle, E., Hellstern, T. R., Ayers, K., & Jaramillo, T. F. (2019) · Nature Nanotechnology · doi:10.1038/s41565-019-0550-7 · Cited by 363
Current Challenges in Catalyst Development for PEM Water Electrolyzers
Bernt, M., Hartig‐Weiß, A., Tovini, M. F., El‐Sayed, H. A., Schramm, C., Schröter, J., Gebauer, C., & Gasteiger, H. A. (2020) · Chemie Ingenieur Technik · doi:10.1002/cite.201900101 · Cited by 333
Self-citationPham, C. V., Escalera‐López, D., Mayrhofer, K., Cherevko, S., & Thiele, S. (2021) · Advanced Energy Materials · doi:10.1002/aenm.202101998 · Cited by 301
Advances in Oxygen Evolution Electrocatalysts for Proton Exchange Membrane Water Electrolyzers
Chen, Z., Guo, L., Pan, L., Yan, T., He, Z., Li, Y., Shi, C., Huang, Z., Zhang, X., & Zou, J. (2022) · Advanced Energy Materials · doi:10.1002/aenm.202103670 · Cited by 298
Mass transport in PEM water electrolysers: A review
Maier, M., Smith, K., Dodwell, J., Hinds, G., Shearing, P. R., & Brett, D. J. L. (2022) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2021.10.013 · Cited by 268
Electrolyzer Durability at Low Catalyst Loading and with Dynamic Operation
Alia, S. M., Stariha, S., & Borup, R. L. (2019) · Journal of The Electrochemical Society · doi:10.1149/2.0231915jes · Cited by 263
Pham, C. V., Bühler, M., Knöppel, J., Bierling, M., Seeberger, D., Escalera-López, D., Mayrhofer, K. J. J., Cherevko, S., & Thiele, S. (2020) · Applied Catalysis B: Environmental · doi:10.1016/j.apcatb.2020.118762 · Cited by 226
Hartig-Weiss, A., Tovini, M. F., Gasteiger, H. A., & El-Sayed, H. A. (2020) · ACS Applied Energy Materials · doi:10.1021/acsaem.0c01944 · Cited by 100
Self-citationAbbou, S., Chattot, R., Martin, V., Claudel, F., Solà-Hernandez, L., Beauger, C., Dubau, L., & Maillard, F. (2020) · ACS Catalysis · doi:10.1021/acscatal.0c01084 · Cited by 93
Phan, T. T., Kim, S.-K., Islam, J., Kim, M.-J., & Lee, J.-H. (2024) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2023.09.274 · Cited by 66
Metadata
- Authors
- Weiß, A., Siebel, A., Bernt, M., Shen, T.-H., Tileli, V., & Gasteiger, H. A.
- Venue
- Journal of The Electrochemical Society
- Publisher
- The Electrochemical Society
- Published
- 2019
- Volume
- 166
- Issue
- 8
- Pages
- F487-F497
- ISSN
- 0013-4651 (ISSN-L)
- 1945-7111
- OpenAlex
- W2942832255
- Cited by
- 413
- References
- 36
- FWCI
- 8.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.