Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 421

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

The Impact of Platinum Loading on Oxygen Transport Resistance

Greszler, Thomas A., Caulk, David, Sinha, Puneet·2012·Journal of The Electrochemical Society

Abstract

The effect of cathode platinum loading on oxygen transport resistance in a fuel cell electrode was determined by measuring limiting current in fuel cells over a wide range of platinum loadings (0.03 to 0.40 mg Pt /cm 2 ). The measurements show that the electrode oxygen transport resistance is inversely proportional to platinum loading or, equivalently, platinum surface area, and is mathematically similar to a 12 s/cm resistive film coating the active platinum sites. At low platinum loading this anomalous resistance significantly reduces the partial pressure of oxygen at the platinum surface and seriously degrades fuel cell performance at high power conditions. The magnitude of this film-like resistance is equivalent to ∼35 nm of bulk-like ionomer but only 4–10 nm, assuming uniform coating, is present in the electrode. Alternatively, 380 nm diameter agglomerates with 20 nm of ionomer coating their external surface would create the same resistance, but such agglomerates are not apparent in SEM micrographs. As a result, the source of this resistance remains unknown, and further investigations are required to understand and mitigate it.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1149/2.061212jes

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Greszler, T. A., Caulk, D., & Sinha, P.
Venue
Journal of The Electrochemical Society
Published
2012
Volume
159
Issue
12
Pages
F831-F840
ISSN
  • 0013-4651 (ISSN-L)
  • 1945-7111
OpenAlex
W2056734148
Cited by
421
References
1
FWCI
5.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.