Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
The present study investigated the relationship between blood and subcutaneous interstitial fluid (ISF) glucose by employing an amperometric glucose sensor specifically developed for 3-day continuous glucose monitoring. The apparent sensor sensitivity and ISF glucose equilibration delay were estimated on separate days during hyperglycemic clamps in four dogs in which insulin was either suppressed with somatostatin, allowed to change, or increased with an exogenous infusion. A 2-h sensor “settling-in” period was allowed before the clamps. During insulin deficiency, the sensor sensitivity and ISF glucose delay were 0.23 ± 0.03 nA per mg/dl and 4.4 ± 0.8 min. Sensitivity was not affected by increases in endogenous (0.30 ± 0.04 vs. 0.28 ± 0.04 nA per mg/dl) or exogenous insulin (0.18 ± 0.01 vs. 0.16 ± 0.01 nA per mg/dl) nor was the delay (3.3 ± 1.2 vs. 5.7 ± 1.1 and 9.2 ± 2.6 vs. 12.3 ± 1.7 min; P > 0.05 for all). Sensor glucose accurately predicted plasma glucose without correcting for delays <10 min ( r > 0.9 for all), whereas for longer delays a digital corrective filter was used ( r = 0.91 with filter). We conclude that the relationship between blood and ISF glucose is not affected by insulin and that delays in ISF glucose equilibration can be corrected with digital filters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Digital Signal Processing: Principles, Algorithms, and Applications
Proakis, J. G., & Manolakis, D. G. (1992) · Cited by 4,601
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
A microdialysis method allowing characterization of intercellular water space in humans
Lonnroth, P., Jansson, P. A., & Smith, U. (1987) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1987.253.2.e228 · Cited by 633
Design and in vitro studies of a needle-type glucose sensor for subcutaneous monitoring
Bindra, D. S., Zhang, Y., Wilson, G. S., Sternberg, R., Thevenot, D. R., Moatti, D., & Reach, G. (1991) · Analytical Chemistry · doi:10.1021/ac00017a008 · Cited by 309 · cited 1×
“The principle is based on the generation of hydrogen peroxide from glucose and oxygen via the enzyme glucose oxidase (2, 5, 9, 18, 32).”
BackgroundMaggs, D. G., Jacob, R., Rife, F., Lange, R., Leone, P., During, M. J., Tamborlane, W. V., & Sherwin, R. S. (1995) · Journal of Clinical Investigation · doi:10.1172/jci118043 · Cited by 183
Measurement of glucose in diabetic subjects using noninvasive transdermal extraction
Tamada, J. A., Bohannon, N. J. V., & Potts, R. O. (1995) · Nature Medicine · doi:10.1038/nm1195-1198 · Cited by 182
Bolincier, J., Ungerstedt, U., & Arner, P. (1992) · Diabetologia · doi:10.1007/bf00401374 · Cited by 142
Steil, G. M., Ader, M., Moore, D. M., Rebrin, K., & Bergman, R. N. (1996) · Journal of Clinical Investigation · doi:10.1172/jci118572 · Cited by 138
Self-citationGlucose measurement in patients with diabetes mellitus with dermal interstitial fluid
Bantle, J. P., & Thomas, W. (1997) · Journal of Laboratory and Clinical Medicine · doi:10.1016/s0022-2143(97)90044-5 · Cited by 128
Schmidtke, D. W., Freeland, A. C., Heller, A., & Bonnecaze, R. T. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.1.294 · Cited by 118
Thomé-Duret, V., Reach, G., Gangnerau, M. N., Lemonnier, F., Klein, J. C., Zhang, Y., Hu, Y., & Wilson, G. S. (1996) · Analytical Chemistry · doi:10.1021/ac960069i · Cited by 118
Characterization by microdialysis of intracellular glucose level in subcutaneous tissue in humans
Jansson, P. A., Fowelin, J., Smith, U., & Lonnroth, P. (1988) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1988.255.2.e218 · Cited by 118
Glycaemic control in pancreatectomized dogs with a wearable artificial endocrine pancreas
Shichiri, M., Kawamori, R., Goriya, Y., Yamasaki, Y., Nomura, M., Hakui, N., & Abe, H. (1983) · Diabetologia · doi:10.1007/bf00250158 · Cited by 114
Pickup, J. C., Shaw, G. W., & Claremont, D. J. (1989) · Diabetologia · doi:10.1007/bf00265097 · Cited by 114
Fischer, U., Ertle, R., Abel, P., Rebrin, K., Brunstein, E., von Dorsche, H. H., & Freyse, E. (1987) · Diabetologia · doi:10.1007/bf00295878 · Cited by 103
Self-citationDoes fall in tissue glucose precede fall in blood glucose?
Sternberg, F., Meyerhoff, C., Mennel, F. J., Mayer, H. G., Bischof, F., & Pfeiffer, E. F. (1996) · Diabetologia · doi:10.1007/bf00403309 · Cited by 101
Subcutaneous implantation of a ferrocene-mediated glucose sensor in pigs
Claremont, D. J., Sambrook, E., Penton, C., & Pickup, J. C. (1986) · Diabetologia · doi:10.1007/bf00873223 · Cited by 95
[Measuring EEG complexity for studying the state of mental load].
Liu, J., He, T., Zheng, C., & Huang, Y. (1997) · PubMed · Cited by 92
Yang, Y. J., Hope, I. D., Ader, M., & Bergman, R. N. (1994) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1994.266.1.e17 · Cited by 90
Subcutaneous glucose monitoring by means of electrochemical sensors: fiction or reality?
Rebrin, K., Fischer, U., Hahn von Dorsche, H., von Woetke, T., Abel, P., & Brunstein, E. (1992) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(92)90033-h · Cited by 81
Self-citationMoberg, E., Toft, E., Amer, P., & Bolinder, J. (1997) · Diabetologia · doi:10.1007/s001250050827 · Cited by 80
Direct access to interstitial fluid in adipose tissue in humans by use of open-flow microperfusion
Schaupp, L., Ellmerer, M., Brunner, G. A., Wutte, A., Sendlhofer, G., Trajanoski, Z., Skrabal, F., Pieber, T. R., & Wach, P. (1999) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1999.276.2.e401 · Cited by 75
In vivo evaluation of an electroenzymatic glucose sensor implanted in subcutaneous tissue
Johnson, K. W., Mastrototaro, J. J., Howey, D. C., Brunelle, R. L., Burden-Brady, P. L., Bryan, N. A., Andrew, C. C., Rowe, H., Allen, D. J., Noffke, B. W., et al. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)85053-d · Cited by 73
Self-citationGlucose Concentration in Subcutaneous Extracellular Space
Schmidt, F. J., Sluiter, W. J., & Schoonen, A. J. (1993) · Diabetes Care · doi:10.2337/diacare.16.5.695 · Cited by 71
Müller, M., Schmid, R., Nieszpaur-Los, M., Fassolt, A., Lönnroth, P., Fasching, P., & Eichler, H. G. (1995) · European Journal of Clinical Investigation · doi:10.1111/j.1365-2362.1995.tb01752.x · Cited by 69
Pfeiffer, E. F., Meyerhoff, C., Bischof, F., Keck, F. S., & Kerner, W. (1993) · Hormone and Metabolic Research · doi:10.1055/s-2007-1002057 · Cited by 68
Poulin, R. A., Steil, G. M., Moore, D. M., Ader, M., & Bergman, R. N. (1994) · Diabetes · doi:10.2337/diab.43.2.180 · Cited by 65
Self-citationSubcutaneous Glucose Concentration in Humans: Real estimation and continuous monitoring
Sternberg, F., Meyerhoff, C., Mennel, F. J., Bischof, F., & Pfeiffer, E. F. (1995) · Diabetes Care · doi:10.2337/diacare.18.9.1266 · Cited by 65
Automated feedback control of subcutaneous glucose concentration in diabetic dogs
Rebrin, K., Fischer, U., von Woedtke, T., Abel, P., & Brunstein, E. (1989) · Diabetologia · doi:10.1007/bf00285330 · Cited by 59
Self-citationMicrodialysis of Glucose in Subcutaneous Adipose Tissue up to 3 Weeks in Healthy Volunteers
Wientjes, K. J., Vonk, P., Vonk-van Klei, Y., Schoonen, A. J., & Kossen, N. W. (1998) · Diabetes Care · doi:10.2337/diacare.21.9.1481 · Cited by 58
Experience with an implantable glucose sensor as a prerequisite of an artificial beta cell.
Abel, P., Müller, A., & Fischer, U. (1984) · PubMed · Cited by 53
Dermal Interstitial Glucose as an Indicator of Ambient Glycemia
Service, F. J., O'Brien, P. C., Wise, S. D., Ness, S., & LeBlanc, S. M. (1997) · Diabetes Care · doi:10.2337/diacare.20.9.1426 · Cited by 48
Development of a Wearable Glucose Sensor; Studies in Healthy Volunteers and in Diabetic Patients
Aalders, A. L., Schmidt, F. J., Schoonen, A. J. M., Broek, I. R., Maessen, A. G. F. M., & Doorenbos, H. (1991) · The International Journal of Artificial Organs · doi:10.1177/039139889101400210 · Cited by 47
An electroenzymatic glucose sensor fabricated on a flexible substrate
Mastrototaro, J. J., Johnson, K. W., Morff, R. J., Lipson, D. A., Andrew, C. C., & Allen, D. J. (1991) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(91)80234-b · Cited by 40
Self-citationQuinn, C. P., Pishko, M. V., Schmidtke, D. W., Ishikawa, M., Wagner, J. G., Raskin, P., Hubbell, J. A., & Heller, A. (1995) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1995.269.1.e155 · Cited by 38
Continuous in vivo monitoring in diabetes: the subcutaneous glucose concentration
FISCHER, U. (1995) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1995.tb04252.x · Cited by 35
Steil, G. M., Rebrin, K., Mittelman, S. D., & Bergman, R. N. (1998) · Diabetes · doi:10.2337/diabetes.47.5.714 · Cited by 29
Self-citationGlucose Concentration at Possible Sensor Tissue Implant Sites
Wolfson, S. K., Tokarsky, J. M., Yao, S. J., & Krupper, M. A. (1982) · Diabetes Care · doi:10.2337/diacare.5.3.162 · Cited by 22
Cited by
Type 1 diabetes: new perspectives on disease pathogenesis and treatment
Atkinson, M. A., & Eisenbarth, G. S. (2001) · The Lancet · doi:10.1016/s0140-6736(01)05415-0 · Cited by 1,491
Biosensors for real-time in vivo measurements
Wilson, G. S., & Gifford, R. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.12.003 · Cited by 660
“Otherwise the ratio is defined by the complicated interplay of glucose physiology and insulin kinetics (Aussedat et al., 2000; Rebrin et al., 1999).”
BackgroundArtificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
Diabetes: Models, Signals, and Control
Cobelli, C., Dalla Man, C., Sparacino, G., Magni, L., De Nicolao, G., & Kovatchev, B. P. (2009) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2009.2036073 · Cited by 511
“fall in IG would precede fall in BG [196], [212].”
Continuous glucose monitoring and closed‐loop systems
Hovorka, R. (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2005.01672.x · Cited by 443
Metadata
- Authors
- Rebrin, K., Steil, G. M., van Antwerp, W. P., & Mastrototaro, J. J.
- Venue
- American Journal of Physiology-Endocrinology and Metabolism
- Publisher
- American Physiological Society
- Published
- 1999-09-01
- Volume
- 277
- Issue
- 3
- Pages
- E561-E571
- ISSN
- 0193-1849 (ISSN-L)
- 1522-1555
- OpenAlex
- W2095833129
- Cited by
- 366
- References
- 38
- FWCI
- 6.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.