Engineering of fibrin-based functional and implantable small-diameter blood vessels
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
We engineered implantable small-diameter blood vessels based on ovine smooth muscle and endothelial cells embedded in fibrin gels. Cylindrical tissue constructs remodeled the fibrin matrix and exhibited considerable reactivity in response to receptor- and nonreceptor-mediated vasoconstrictors and dilators. Aprotinin, a protease inhibitor of fibrinolysis, was added at varying concentrations and affected the development and functionality of tissue-engineered blood vessels (TEVs) in a concentration-dependent manner. Interestingly, at moderate concentrations, aprotinin increased mechanical strength but decreased vascular reactivity, indicating a possible relationship between matrix degradation/remodeling, vasoreactivity, and mechanical properties. TEVs developed considerable mechanical strength to withstand interpositional implantation in jugular veins of lambs. Implanted TEVs integrated well with the native vessel and demonstrated patency and similar blood flow rates as the native vessels. At 15 wk postimplantation, TEVs exhibited remarkable matrix remodeling with production of collagen and elastin fibers and orientation of smooth muscle cells perpendicular to the direction of blood flow. Implanted vessels gained significant mechanical strength and reactivity that were comparable to those of native veins. Our work demonstrates that fibrin-based TEVs hold significant promise for treatment of vascular disease and as a biological model for studying vascular development and pathophysiology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
A completely biological tissue-engineered human blood vessel
L'heureux, N., Pâquet, S., Labbé, R., Germain, L., & Auger, F. A. (1998) · The FASEB Journal · doi:10.1096/fasebj.12.1.47 · Cited by 1,402
A Blood Vessel Model Constructed from Collagen and Cultured Vascular Cells
Weinberg, C. B., & Bell, E. (1986) · Science · doi:10.1126/science.2934816 · Cited by 1,240
Functional small-diameter neovessels created using endothelial progenitor cells expanded ex vivo
Kaushal, S., Amiel, G. E., Guleserian, K. J., Shapira, O. M., Perry, T., Sutherland, F. W., Rabkin, E., Moran, A. M., Schoen, F. J., Atala, A., et al. (2001) · Nature Medicine · doi:10.1038/nm0901-1035 · Cited by 841
Dynamic Mechanical Conditioning of Collagen-Gel Blood Vessel Constructs Induces Remodeling In Vitro
Seliktar, D., Black, R. A., Vito, R. P., & Nerem, R. M. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.275 · Cited by 555
Dvorak, H. F., Harvey, V. S., Estrella, P., Brown, L. F., McDonagh, J., & Dvořàk, A. M. (1987) · PubMed · Cited by 445
Creation Of Viable Pulmonary Artery Autografts Through Tissue Engineering
Shinoka, T., Shum-Tim, D., Ma, P. X., Tanel, R. E., Isogai, N., Langer, R., Vacanti, J. P., & Mayer, J. E. (1998) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(98)70315-0 · Cited by 444
Remodeling of an acellular collagen graft into a physiologically responsive neovessel
Huynh, T., Abraham, G., Murray, J., Brockbank, K., Hagen, P.-O., & Sullivan, S. (1999) · Nature Biotechnology · doi:10.1038/15062 · Cited by 330
Deutsch, M., Meinhart, J., Fischlein, T., Preiss, P., & Zilla, P. (1999) · Surgery · doi:10.1016/s0039-6060(99)70025-5 · Cited by 322
Cummings, C. L., Gawlitta, D., Nerem, R. M., & Stegemann, J. P. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2003.10.073 · Cited by 311
Elastic fiber production in cardiovascular tissue-equivalents
Long, J. L., & Tranquillo, R. T. (2003) · Matrix Biology · doi:10.1016/s0945-053x(03)00052-0 · Cited by 283
Morphologic and mechanical characteristics of engineered bovine arteries
Niklason, L. E., Abbott, W., Gao, J., Klagges, B., Hirschi, K. K., Ulubayram, K., Conroy, N., Jones, R., Vasanawala, A., Sanzgiri, S., et al. (2001) · Journal of Vascular Surgery · doi:10.1067/mva.2001.111747 · Cited by 254
Jones, J. I., Prevette, T., Gockerman, A., & Clemmons, D. R. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.6.2482 · Cited by 246
Estrogen and vascular function
White, R. E. (2002) · Vascular Pharmacology · doi:10.1016/s0306-3623(02)00129-5 · Cited by 208
Long-Term Cyclic Distention Enhances the Mechanical Properties of Collagen-Based Media-Equivalents
Isenberg, B. C., & Tranquillo, R. T. (2003) · Annals of Biomedical Engineering · doi:10.1114/1.1590662 · Cited by 204
Collagen matrices attenuate the collagen-synthetic response of cultured fibroblasts to TGF-β
Clark, R. A. F., Nielsen, L. D., Welch, M. P., & McPherson, J. M. (1995) · Journal of Cell Science · doi:10.1242/jcs.108.3.1251 · Cited by 204
A fibrin‐based arterial media equivalent
Grassl, E. D., Oegema, T. R., & Tranquillo, R. T. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10589 · Cited by 196
Tuan, T.-L., Song, A., Chang, S., Younai, S., & Nimni, M. E. (1996) · Experimental Cell Research · doi:10.1006/excr.1996.0065 · Cited by 195
Mechanical Strain-Stimulated Remodeling of Tissue-Engineered Blood Vessel Constructs
Seliktar, D., Nerem, R. M., & Galis, Z. S. (2003) · Tissue Engineering · doi:10.1089/107632703768247359 · Cited by 179
Signaling through NO and cGMP‐dependent protein kinases
Schlossmann, J., Feil, R., & Hofmann, F. (2003) · Annals of Medicine · doi:10.1080/07853890310004093 · Cited by 176
A biological hybrid model for collagen-based tissue engineered vascular constructs
Berglund, J. D., Mohseni, M. M., Nerem, R. M., & Sambanis, A. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00506-9 · Cited by 167
L’HEUREUX, N., STOCLET, J., AUGER, F. A., LAGAUD, G. J., GERMAIN, L., & ANDRIANTSLTOHAINA, R. (2001) · The FASEB Journal · doi:10.1096/fj.00-0283com · Cited by 165
Engineered Alignment in Media Equivalents: Magnetic Prealignment and Mandrel Compaction
Barocas, V. H., Girton, T. S., & Tranquillo, R. T. (1998) · Journal of Biomechanical Engineering · doi:10.1115/1.2834759 · Cited by 164
Seliktar, D., Nerem, R. M., & Galis, Z. S. (2001) · Annals of Biomedical Engineering · doi:10.1114/1.1415522 · Cited by 149
Effects of polyglycolic acid on porcine smooth muscle cell growth and differentiation
Higgins, S. P., Solan, A. K., & Niklason, L. E. (2003) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.10599 · Cited by 147
Engineering of human vascular aortic tissue based on a xenogeneic starter matrix.
Bader, A., Steinhoff, G., Strobl, K., Schilling, T., Brandes, G., Mertsching, H., Tsikas, D., Froelich, J., & Haverich, A. (2000) · PubMed · Cited by 126
Hirai, J., & Matsuda, T. (1996) · Cell Transplantation · doi:10.1016/0963-6897(95)02002-0 · Cited by 120
Fibrin Promotes Migration in a Three-Dimensional in Vitro Model of Wound Regeneration
Geer, D. J., Swartz, D. D., & Andreadis, S. T. (2002) · Tissue Engineering · doi:10.1089/10763270260424141 · Cited by 110
Self-citationWilliams, S. K., Rose, D. G., & Jarrell, B. E. (1994) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820280210 · Cited by 105
In Vivo Model of Wound Healing Based on Transplanted Tissue-Engineered Skin
Geer, D. J., Swartz, D. D., & Andreadis, S. T. (2004) · Tissue Engineering · doi:10.1089/ten.2004.10.1006 · Cited by 86
Self-citationExperimental and Clinical Experience with a Gelatin Impregnated Dacron Prosthesis
Drury, J. K., Ashton, T. R., Cunningham, J. D., Maini, R., & Pollock, J. G. (1987) · Annals of Vascular Surgery · doi:10.1016/s0890-5096(06)61437-4 · Cited by 83
Aging, ion channel expression, and vascular function
Toro, L., Marijic, J., Nishimaru, K., Tanaka, Y., Song, M., & Stefani, E. (2002) · Vascular Pharmacology · doi:10.1016/s0306-3623(02)00128-3 · Cited by 73
Thie, M., Schlumberger, W., Semich, R., et al. (1991) · PubMed · Cited by 67
Clinical Experience with a Collagen-Impregnated Knitted Dacron Vascular Graft
Freischlag, J. A., & Moore, W. S. (1990) · Annals of Vascular Surgery · doi:10.1016/s0890-5096(07)60069-7 · Cited by 45
Seeding With Omental Cells Prevents Late Neointimal Hyperplasia in Small-Diameter Dacron Grafts
Pašić, M., Müller-Glauser, W., Odermatt, B., Lachat, M. L., Seifert, B., & Turina, M. I. (1995) · Circulation · doi:10.1161/01.cir.92.9.2605 · Cited by 40
Cited by
Fibrin: A versatile scaffold for tissue engineering applications
Ahmed, T. A. E., Dare, E. V., & Hincke, M. (2008) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2007.0435 · Cited by 994
The Tissue-Engineered Vascular Graft—Past, Present, and Future
Pashneh-Tala, S., MacNeil, S., & Claeyssens, F. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0100 · Cited by 798
Small-diameter vascular tissue engineering
Seifu, D. G., Purnama, A., Mequanint, K., & Mantovani, D. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.77 · Cited by 501
Small-Diameter Artificial Arteries Engineered In Vitro
Isenberg, B. C., Williams, C., & Tranquillo, R. T. (2006) · Circulation Research · doi:10.1161/01.res.0000196867.12470.84 · Cited by 469
Biomaterials for Vascular Tissue Engineering
Ravi, S., & Chaikof, E. L. (2010) · Regenerative Medicine · doi:10.2217/rme.09.77 · Cited by 387
Metadata
- Authors
- Swartz, D. D., Russell, J. A., & Andreadis, S. T.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2005-03
- Volume
- 288
- Issue
- 3
- Pages
- H1451-H1460
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1991016293
- Cited by
- 277
- References
- 35
- FWCI
- 10.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.