CoChat

Modulation of lymphatic muscle contractility by the neuropeptide substance P

Open access
Davis, Michael J., Lane, Megan M., Davis, Ann M., Durtschi, David, Zawieja, David C., Muthuchamy, Mariappan, Gashev, Anatoliy A. · 2008 · American Journal of Physiology-Heart and Circulatory Physiology
Cited by 81

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Substance P (SP) is a neuropeptide associated with sensory innervation of lymphoid tissue and a suspected modulator of lymphatic function in inflammation. Only a few studies have examined the effects of SP on lymphatic contraction, and it is not clear to what extent SP acts directly on the lymphatic muscle and/or endothelium or indirectly through changes in intraluminal filling pressure secondary to increases in capillary permeability/filtration. We tested the effects of SP on the spontaneous contractions of rat isolated mesenteric lymphatic vessels under isometric and isobaric conditions, hypothesizing that low concentrations would stimulate lymphatic pumping by enhancing lymphatic muscle contraction in a manner complementary to the effect of increased preload. Under isometric conditions, SP (10 nM) dramatically enhanced lymphatic chronotropy and inotropy. Unlike guinea pig lymphatics, SP actions were not blocked by cyclooxygenase or PLA 2 inhibition. In the absence of SP, ramp increases in isometric preload resulted in ×∼1.6 increases in contraction amplitude (Amp) and ×∼1.7 increases in frequency (Freq). SP increased Freq by ×∼2.4, Amp by ×∼1.9, and the Amp-Freq product (AFP) by ×∼3.5. Under isobaric conditions, the pressure elevation from 0.5 to 10 cmH 2 O in the absence of SP decreased Amp by ×∼0.6 and increased Freq by ×∼1.8. SP caused a modest increase in Amp, a robust increase in Freq at all pressures, and shifted the AFP-pressure relationship upward and leftward. Therefore, SP has substantial positive inotropic and chronotropic effects on rat lymphatic muscle, improving pump efficiency independent of the effects of preload and broadening of the working range of the lymphatic pump.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/ajpheart.01029.2007

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Davis, M. J., Lane, M. M., Davis, A. M., Durtschi, D., Zawieja, D. C., Muthuchamy, M., & Gashev, A. A.
Venue
American Journal of Physiology-Heart and Circulatory Physiology
Published
2008-08
Volume
295
Issue
2
Pages
H587-H597
ISSN
  • 0363-6135 (ISSN-L)
  • 1522-1539
OpenAlex
W2128659492
Cited by
81
References
1
FWCI
3.08
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.