We determined total arterial compliance from pressure and flow in the ascending aorta of seven anesthetized dogs using the pulse pressure method (PPM) and the decay time method (DTM). Compliance was determined under control and during occlusion of the aorta at four different locations (iliac, renal, diaphragm, and proximal descending thoracic aorta). Compliance of PPM gave consistently lower values (0.893 ± 0.015) compared with the compliance of DTM (means ± SE; r = 0.989). The lower compliance estimates by the PPM can be attributed to the difference in mean pressures at which compliance is determined (mean pressure, 81.0 ± 3.6 mmHg; mean diastolic pressure, over which the DTM applies, 67.0 ± 3.6 mmHg). Total arterial compliance under control conditions was 0.169 ± 0.007 ml/mmHg. Compliance of the proximal aorta, obtained during occlusion of the proximal descending aorta, was 0.100 ± 0.007 ml/mmHg. Mean aortic pressure was 80.4 ± 3.6 mmHg during control and 102 ± 7.7 mmHg during proximal descending aortic occlusion. From these results and assuming that upper limbs and the head contribute as little as the lower limbs, we conclude that 60% of total arterial compliance resides in the proximal aorta. When we take into account the inverse relationship between pressure and compliance, the contribution of the proximal aorta to the total arterial compliance is even more significant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pulse Pressure: A Predictor of Long-term Cardiovascular Mortality in a French Male Population
Benetos, A., Safar, M., Rudnichi, A., Smulyan, H., Richard, J.-L., Ducimetière, P., & Guize, L. (1997) · Hypertension · doi:10.1161/01.hyp.30.6.1410 · Cited by 1,034
Langewouters, G. J., Wesseling, K. H., & Goedhard, W. J. A. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90034-4 · Cited by 544
Mitchell, G. F., Moyé, L. A., Braunwald, E., Rouleau, J.-L., Bernstein, V., Geltman, E. M., Flaker, G. C., Pfeffer, M. A., & Investigators, F. T. S. (1997) · Circulation · doi:10.1161/01.cir.96.12.4254 · Cited by 531
Computer simulation of arterial flow with applications to arterial and aortic stenoses
Stergiopulos, N., Young, D. F., & Rogge, T. R. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90060-e · Cited by 511
Self-citationTotal arterial compliance estimated by stroke volume-to-aortic pulse pressure ratio in humans
Chemla, D., Hébert, J.-L., Coirault, C., Zamani, K., Suard, I., Colin, P., & Lecarpentier, Y. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.274.2.h500 · Cited by 462
Estimation of total arterial compliance: an improved method and evaluation of current methods
Liu, Z., Brin, K. P., & Yin, F. C. (1986) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1986.251.3.h588 · Cited by 378
Pressure and Flow Generated by the Left Ventricle against Different Impedances
ELZINGA, G., & WESTERHOF, N. (1973) · Circulation Research · doi:10.1161/01.res.32.2.178 · Cited by 270
Self-citationEvaluation of methods for estimation of total arterial compliance
Stergiopulos, N., Meister, J. J., & Westerhof, N. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.268.4.h1540 · Cited by 267
Self-citationSagawa, K. (1990) · Journal of Molecular and Cellular Cardiology · doi:10.1016/0022-2828(90)91459-k · Cited by 229
Stergiopulos, N., Meister, J. J., & Westerhof, N. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368245 · Cited by 173
Self-citation
Cited by
Westerhof, N., Lankhaar, J.-W., & Westerhof, B. E. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-008-0359-2 · Cited by 1,181
Self-citationPulse pressure—a review of mechanisms and clinical relevance
Dart, A. M., & Kingwell, B. A. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01108-1 · Cited by 836
“Arterial C can be estimated from the decay in diastolic pressure (2) as well as by the simpler approach of: C 5 stroke volume (SV)/PP, and studies have suggested reasonable correspondence between these meth-ods (3,4).”
MethodImproved Arterial Compliance by a Novel Advanced Glycation End-Product Crosslink Breaker
Kass, D. A., Shapiro, E. P., Kawaguchi, M., Capriotti, A. R., Scuteri, A., deGroof, R. C., & Lakatta, E. G. (2001) · Circulation · doi:10.1161/hc3801.097806 · Cited by 727
Validation of a one-dimensional model of the systemic arterial tree
Reymond, P., Merenda, F., Perren, F., Rüfenacht, D., & Stergiopulos, N. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00037.2009 · Cited by 638
Self-citationPatient-Specific Modeling of Blood Flow and Pressure in Human Coronary Arteries
Kim, H. J., Vignon-Clementel, I. E., Coogan, J. S., Figueroa, C. A., Jansen, K. E., & Taylor, C. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0083-6 · Cited by 628
Vonk Noordegraaf, A., Chin, K. M., Haddad, F., Hassoun, P. M., Hemnes, A. R., Hopkins, S. R., Kawut, S. M., Langleben, D., Lumens, J., & Naeije, R. (2019) · European Respiratory Journal · doi:10.1183/13993003.01900-2018 · Cited by 569
Pulmonary Capillary Wedge Pressure Augments Right Ventricular Pulsatile Loading
Tedford, R. J., Hassoun, P. M., Mathai, S. C., Girgis, R. E., Russell, S. D., Thiemann, D. R., Cingolani, O. H., Mudd, J. O., Borlaug, B. A., Redfield, M. M., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.051540 · Cited by 479
Schram, M. T., Henry, R. M. A., van Dijk, R. A. J. M., Kostense, P. J., Dekker, J. M., Nijpels, G., Heine, R. J., Bouter, L. M., Westerhof, N., & Stehouwer, C. D. A. (2004) · Hypertension · doi:10.1161/01.hyp.0000111829.46090.92 · Cited by 428
Self-citationOn Coupling a Lumped Parameter Heart Model and a Three-Dimensional Finite Element Aorta Model
Kim, H. J., Vignon-Clementel, I. E., Figueroa, C. A., LaDisa, J. F., Jansen, K. E., Feinstein, J. A., & Taylor, C. A. (2009) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9760-8 · Cited by 333
Segers, P., Rietzschel, E. R., De Buyzere, M. L., Vermeersch, S. J., De Bacquer, D., Van Bortel, L. M., De Backer, G., Gillebert, T. C., & Verdonck, P. R. (2007) · Hypertension · doi:10.1161/hypertensionaha.106.085480 · Cited by 319
Self-citationLes, A. S., Shadden, S. C., Figueroa, C. A., Park, J. M., Tedesco, M. M., Herfkens, R. J., Dalman, R. L., & Taylor, C. A. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-9949-x · Cited by 314
Time-domain representation of ventricular-arterial coupling as a windkessel and wave system
Wang, J.-J., O'Brien, A. B., Shrive, N. G., Parker, K. H., & Tyberg, J. V. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00175.2002 · Cited by 298
Right Ventricular Dysfunction in Systemic Sclerosis–Associated Pulmonary Arterial Hypertension
Tedford, R. J., Mudd, J. O., Girgis, R. E., Mathai, S. C., Zaiman, A. L., Housten-Harris, T., Boyce, D., Kelemen, B. W., Bacher, A. C., Shah, A. A., et al. (2013) · Circulation: Heart Failure · doi:10.1161/circheartfailure.112.000008 · Cited by 289
A guide to uncertainty quantification and sensitivity analysis for cardiovascular applications
Eck, V. G., Donders, W. P., Sturdy, J., Feinberg, J., Delhaas, T., Hellevik, L. R., & Huberts, W. (2016) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2755 · Cited by 163
“, non-invasive) clinical measurements of systolic and diastolic pressures [85, 86].”
BackgroundComputational Simulations for Aortic Coarctation: Representative Results From a Sampling of Patients
LaDisa, J. F., Alberto Figueroa, C., Vignon-Clementel, I. E., Jin Kim, H., Xiao, N., Ellwein, L. M., Chan, F. P., Feinstein, J. A., & Taylor, C. A. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4004996 · Cited by 159
“Once the capacitance term for each branch was assigned, the terminal resistance (Rt1⁄4RcþRd) was calculated from mean BP and PC-MRI flow measurements and distributed between the remaining resistance parameters by adjusting Rc to Rt ratios (6%–10%) for each outlet using the pulse pressure method [15,16] thereby replica…”
MethodTada, A., Burkhoff, D., Naser, J. A., Harada, T., Pourmussa, B., Reddy, Y. N. V., Jensen, M. D., Carter, R. E., Demmer, R. T., Testani, J. M., et al. (2024) · Circulation · doi:10.1161/circulationaha.124.068788 · Cited by 42
Metadata
- Authors
- Stergiopulos, N., Segers, P., & Westerhof, N.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1999-02-01
- Volume
- 276
- Issue
- 2
- Pages
- H424-H428
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2163235023
- Cited by
- 211
- References
- 16
- FWCI
- 2.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.