Ficoll and dextran vs. globular proteins as probes for testing glomerular permselectivity: effects of molecular size, shape, charge, and deformability
The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Polydisperse mixtures of dextran or Ficoll have been frequently used as molecular probes for studies of glomerular permselectivity because they are largely inert and not processed (reabsorbed) by the proximal tubules. However, dextrans are linear, flexible molecules, which apparently are hyperpermeable across the glomerular barrier. By contrast, the Ficoll molecule is almost spherical. Still, there is ample evidence that Ficoll fractional clearances (sieving coefficients) across the glomerular capillary wall (GCW) are markedly higher than those for neutral globular proteins of an equivalent in vitro Stokes-Einstein (SE) radius. Physical data, obtained by “crowding” experiments or measurements of intrinsic viscosity, suggest that the Ficoll molecule exhibits a rather open, deformable structure and thus deviates from an ideally hard sphere. This is also indicated from the relationship between (log) in vitro SE radius and (log) molecular weight (MW). Whereas globular proteins seem to behave in a way similar to hydrated hard spheres, polydisperse dextran and Ficoll exhibit in vitro SE radii that are much larger than those for compact spherical molecules of equivalent MW. For dextran, this can be partially explained by a high-molecular-size asymmetry. However, for Ficoll the explanation may be that the Ficoll molecule is more flexible (deformable) than are globular proteins. An increased compressibility of Ficoll and an increased deformability and size asymmetry for dextran may be the explanation for the fact that the permeability of the GCW is significantly higher when assessed using polysaccharides such as Ficoll or dextran compared with that obtained using globular proteins as molecular size probes. We suggest that molecular deformability, besides molecular size, shape, and charge, plays a crucial role in determining the glomerular permeability to molecules of different species.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Kidney: Physiology and Pathophysiology
(1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-117-6-544_3 · Cited by 1,673
Diffusion of Macromolecules in Agarose Gels: Comparison of Linear and Globular Configurations
Pluen, A., Netti, P. A., Jain, R. K., & Berk, D. A. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76911-0 · Cited by 573
Transport of macromolecules across microvascular walls: the two-pore theory
Rippe, B., & Haraldsson, B. (1994) · Physiological Reviews · doi:10.1152/physrev.1994.74.1.163 · Cited by 560
Self-citationStructural determinants of glomerular permeability
Deen, W. M., Lazzara, M. J., & Myers, B. D. (2001) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.2001.281.4.f579 · Cited by 413
MacMillan's chemical and physical data
(1993) · Biochemical Education · doi:10.1016/0307-4412(93)90067-a · Cited by 393
Permselectivity of the glomerular capillary wall: III. Restricted transport of polyanions
Chang, R. L. S., Deen, W. M., Robertson, C. R., & Brenner, B. M. (1975) · Kidney International · doi:10.1038/ki.1975.104 · Cited by 386
Molecular weight distribution analysis by gel chromatography on sephadex
Granath, K. A., & Kvist, B. E. (1967) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)85930-6 · Cited by 335
Hindered diffusion in agarose gels: test of effective medium model
Johnson, E. M., Berk, D. A., Jain, R. K., & Deen, W. M. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79645-5 · Cited by 328
Permselectivity of the Glomerular Capillary Wall
Bohrer, M. P., Baylis, C., Humes, H. D., Glassock, R. J., Robertson, C. R., & Brenner, B. M. (1978) · Journal of Clinical Investigation · doi:10.1172/jci108927 · Cited by 312
Glomerular protein sieving and implications for renal failure in Fanconi syndrome
Norden, A. G. W., Lapsley, M., Lee, P. J., Pusey, C. D., Scheinman, S. J., Tam, F. W. K., Thakker, R. V., Unwin, R. J., & Wrong, O. (2001) · Kidney International · doi:10.1046/j.1523-1755.2001.00016.x · Cited by 241
Cited by
Nanoparticle therapeutics: an emerging treatment modality for cancer
Davis, M. E., Chen, Z., & Shin, D. M. (2008) · Nature Reviews Drug Discovery · doi:10.1038/nrd2614 · Cited by 4,233
Aptamer-Based Multiplexed Proteomic Technology for Biomarker Discovery
Gold, L., Ayers, D., Bertino, J., Bock, C., Bock, A., Brody, E. N., Carter, J., Dalby, A. B., Eaton, B. E., Fitzwater, T., et al. (2010) · PLoS ONE · doi:10.1371/journal.pone.0015004 · Cited by 1,754
“We chose CKD as a test case because kidney physiology provides filtration of serum molecules based on size (molecular mass) and charge [32] – thus CKD might lead to an increase in the concentration of small proteins (MW ,45 kDa).”
MethodNanoparticle-Based Drug Delivery in Cancer Therapy and Its Role in Overcoming Drug Resistance
Yao, Y., Zhou, Y., Liu, L., Xu, Y., Chen, Q., Wang, Y., Wu, S., Deng, Y., Zhang, J., & Shao, A. (2020) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2020.00193 · Cited by 1,451
Duan, X., & Li, Y. (2013) · Small · doi:10.1002/smll.201201390 · Cited by 926
Properties of the Glomerular Barrier and Mechanisms of Proteinuria
Haraldsson, B., Nyström, J., & Deen, W. M. (2008) · Physiological Reviews · doi:10.1152/physrev.00055.2006 · Cited by 909
A review of current nanoparticle and targeting moieties for the delivery of cancer therapeutics
Steichen, S. D., Caldorera-Moore, M., & Peppas, N. A. (2013) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2012.12.006 · Cited by 751
Soluble Polymer Carriers for the Treatment of Cancer: The Importance of Molecular Architecture
Fox, M. E., Szoka, F. C., & Fréchet, J. M. J. (2009) · Accounts of Chemical Research · doi:10.1021/ar900035f · Cited by 748
Transport and interactions of nanoparticles in the kidneys
Du, B., Yu, M., & Zheng, J. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0038-3 · Cited by 649
Xu, M., Qi, Y., Liu, G., Song, Y., Jiang, X., & Du, B. (2023) · ACS Nano · doi:10.1021/acsnano.3c05853 · Cited by 632
Kraft, J. C., Freeling, J. P., Wang, Z., & Ho, R. J. Y. (2014) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23773 · Cited by 606
Glomerular barrier behaves as an atomically precise bandpass filter in a sub-nanometre regime
Du, B., Jiang, X., Das, A., Zhou, Q., Yu, M., Jin, R., & Zheng, J. (2017) · Nature Nanotechnology · doi:10.1038/nnano.2017.170 · Cited by 587
Nanotechnology in cancer diagnosis: progress, challenges and opportunities
Zhang, Y., Li, M., Gao, X., Chen, Y., & Liu, T. (2019) · Journal of Hematology & Oncology · doi:10.1186/s13045-019-0833-3 · Cited by 510
Prodrug Strategies in Anticancer Chemotherapy
Kratz, F., Müller, I. A., Ryppa, C., & Warnecke, A. (2008) · ChemMedChem · doi:10.1002/cmdc.200700159 · Cited by 486
More Effective Nanomedicines through Particle Design
Wang, J., Byrne, J. D., Napier, M. E., & DeSimone, J. M. (2011) · Small · doi:10.1002/smll.201100442 · Cited by 466
Molecular imaging and disease theranostics with renal-clearable optical agents
Cheng, P., & Pu, K. (2021) · Nature Reviews Materials · doi:10.1038/s41578-021-00328-6 · Cited by 413
Gandhi, N. S., Tekade, R. K., & Chougule, M. B. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.09.001 · Cited by 394
Biological hydrogels as selective diffusion barriers
Lieleg, O., & Ribbeck, K. (2011) · Trends in Cell Biology · doi:10.1016/j.tcb.2011.06.002 · Cited by 387
Towards clinically translatable in vivo nanodiagnostics
Park, S.-M., Aalipour, A., Vermesh, O., Yu, J. H., & Gambhir, S. S. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.14 · Cited by 327
Models of macromolecular crowding effects and the need for quantitative comparisons with experiment
Elcock, A. H. (2010) · Current Opinion in Structural Biology · doi:10.1016/j.sbi.2010.01.008 · Cited by 286
Gao, S., Dagnaes-Hansen, F., Nielsen, E. J. B., Wengel, J., Besenbacher, F., Howard, K. A., & Kjems, J. (2009) · Molecular Therapy · doi:10.1038/mt.2009.91 · Cited by 286
Synthesis and bio-functionalization of magnetic nanoparticles for medical diagnosis and treatment
Schladt, T. D., Schneider, K., Schild, H., & Tremel, W. (2011) · Dalton Transactions · doi:10.1039/c0dt00689k · Cited by 286
Physicochemical and Biological Characterization of Targeted, Nucleic Acid-Containing Nanoparticles
Bartlett, D. W., & Davis, M. E. (2007) · Bioconjugate Chemistry · doi:10.1021/bc0603539 · Cited by 283
Molecular crowding enhances native structure and stability of α/β protein flavodoxin
Stagg, L., Zhang, S.-Q., Cheung, M. S., & Wittung-Stafshede, P. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0705127104 · Cited by 281
Kutuzov, N., Flyvbjerg, H., & Lauritzen, M. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1802155115 · Cited by 250
Self-assembling peptide-based building blocks in medical applications
Acar, H., Srivastava, S., Chung, E. J., Schnorenberg, M. R., Barrett, J. C., LaBelle, J. L., & Tirrell, M. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.08.006 · Cited by 242
Sakulkhu, U., Mahmoudi, M., Maurizi, L., Salaklang, J., & Hofmann, H. (2014) · Scientific Reports · doi:10.1038/srep05020 · Cited by 237
Recent advances in curcumin nanoformulation for cancer therapy
Lee, W.-H., Loo, C.-Y., Young, P. M., Traini, D., Mason, R. S., & Rohanizadeh, R. (2014) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2014.916686 · Cited by 229
“The lower cut-off diameter is based on the sieving coefficient for glomerular capillary wall whereby any nanoparticles below 10 nm in size are eliminated rapidly by the kidney [29].”
BackgroundA review of small molecules and drug delivery applications using gold and iron nanoparticles
Jahangirian, H., Kalantari, K., Izadiyan, Z., Rafiee-Moghaddam, R., Shameli, K., & Webster, T. J. (2019) · International Journal of Nanomedicine · doi:10.2147/ijn.s184723 · Cited by 228
“For the glomerular capillary wall, with the measurement of sieving coefficients, on the basis of sieving coefficients measured for the glomerular capillary wall, the estimated NP diameter as the threshold for first-pass elimination by the kidneys is 10 nm.(6) By contrast, the vasculature of a tumor is immature and lea…”
MethodMaritim, S., Boulas, P., & Lin, Y. (2021) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.120051 · Cited by 228
A sensor for quantification of macromolecular crowding in living cells
Boersma, A. J., Zuhorn, I. S., & Poolman, B. (2015) · Nature Methods · doi:10.1038/nmeth.3257 · Cited by 227
Small-molecule delivery by nanoparticles for anticancer therapy
Chen, Z. (. (2010) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2010.08.001 · Cited by 212
“On the basis of sieving coefficients measured for the glomerular capillary wall, the threshold for first-pass elimination by the kidneys is estimated at 10 nm (diameter) [7].”
MethodSu, C., Liu, Y., Li, R., Wu, W., Fawcett, J. P., & Gu, J. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.06.008 · Cited by 200
Ma, H., Burger, C., Hsiao, B. S., & Chu, B. (2014) · Journal of Membrane Science · doi:10.1016/j.memsci.2013.11.055 · Cited by 180
Kaminskas, L. M., Boyd, B. J., Karellas, P., Krippner, G. Y., Lessene, R., Kelly, B., & Porter, C. J. H. (2008) · Molecular Pharmaceutics · doi:10.1021/mp7001208 · Cited by 178
Adriamycin Alters Glomerular Endothelium to Induce Proteinuria
Jeansson, M., Bjo[Combining Diaeresis]rck, K., Tenstad, O., & Haraldsson, B. D. (2009) · Journal of the American Society of Nephrology · doi:10.1681/asn.2007111205 · Cited by 175
Clinical Developments in Nanotechnology for Cancer Therapy
Heidel, J. D., & Davis, M. E. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0178-7 · Cited by 170
Biomaterial Strategies for Immunomodulation
Hotaling, N. A., Tang, L., Irvine, D. J., & Babensee, J. E. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-104814 · Cited by 169
“At sizes smaller than 20 nm, NPs are filtered out by the kidney (48); at sizes larger than 100 nm, particles begin to be sequestered by sinusoids in the spleen and fenestrae of the liver (49).”
Imran ul-haq, M., Lai, B. F. L., Chapanian, R., & Kizhakkedathu, J. N. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.09.007 · Cited by 164
Carbon‐Nanotube Shape and Individualization Critical for Renal Excretion
Lacerda, L., Herrero, M. A., Venner, K., Bianco, A., Prato, M., & Kostarelos, K. (2008) · Small · doi:10.1002/smll.200800323 · Cited by 159
Metadata
- Authors
- Venturoli, D., & Rippe, B.
- Venue
- American Journal of Physiology-Renal Physiology
- Publisher
- American Physiological Society
- Published
- 2005-04
- Volume
- 288
- Issue
- 4
- Pages
- F605-F613
- ISSN
- 1522-1466 (ISSN-L)
- 1931-857X
- OpenAlex
- W2006512709
- Cited by
- 461
- References
- 40
- FWCI
- 8.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.