Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans
The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
Bracco, David, Daniel Thiébaud, René L. Chioléro, Michel Landry, Peter Burckhardt, and Yves Schutz.Segmental body composition assessed by bioelectrical impedance analysis and DEXA in humans. J. Appl. Physiol. 81(6): 2580–2587, 1996.—The present study assessed the relative contribution of each body segment to whole body fat-free mass (FFM) and impedance and explored the use of segmental bioelectrical impedance analysis to estimate segmental tissue composition. Multiple frequencies of whole body and segmental impedances were measured in 51 normal and overweight women. Segmental tissue composition was independently assessed by dual-energy X-ray absorptiometry. The sum of the segmental impedance values corresponded to the whole body value (100.5 ± 1.9% at 50 kHz). The arms and legs contributed to 47.6 and 43.0%, respectively, of whole body impedance at 50 kHz, whereas they represented only 10.6 and 34.8% of total FFM, as determined by dual-energy X-ray absorptiometry. The trunk averaged 10.0% of total impedance but represented 48.2% of FFM. For each segment, there was an excellent correlation between the specific impedance index (length 2/impedance) and FFM ( r = 0.55, 0.62, and 0.64 for arm, trunk, and leg, respectively). The specific resistivity was in a similar range for the limbs (159 ± 23 cm for the arm and 193 ± 39 cm for the leg at 50 kHz) but was higher for the trunk (457 ± 71 cm). This study shows the potential interest of segmental body composition by bioelectrical impedance analysis and provides specific segmental body composition equations for use in normal and overweight women.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896 · cited 1×
“ASSESSMENT OF BODY COMPOSITION plays an important role in nutritional evaluation, and bioelectrical impedance analysis (BIA), which has been known for more than 50 years, has become widely used in clinical settings during the last 10 years (10, 13, 14).”
BackgroundThe assessment of the amount of fat in the human body from measurements of skinfold thickness
Durnin, J. V. G. A., & Rahaman, M. M. (1967) · British Journal of Nutrition · doi:10.1079/bjn19670070 · Cited by 1,685 · cited 1×
“An anthropometric evaluation was performed by triplicate skinfold thickness measurement at four sites (biceps, triceps, subscapular, and supra iliac) with a Harpenden caliper (7).”
MethodMazess, R., Barden, H., Bisek, J., & Hanson, J. (1990) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/51.6.1106 · Cited by 1,476
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370 · cited 1×
“ASSESSMENT OF BODY COMPOSITION plays an important role in nutritional evaluation, and bioelectrical impedance analysis (BIA), which has been known for more than 50 years, has become widely used in clinical settings during the last 10 years (10, 13, 14).”
Background11 Applicability of Body Composition Techniques and Constants for Children and Youths
LOHMAN, T. G. (1986) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-198600140-00014 · Cited by 650 · cited 1×
“Whether the FFM of our sample did contain a fixed proportion of water (12) remains to be seen.”
BackgroundBioelectrical Impedance Analysis: A Review of Principles and Applications
Kushner, R. F. (1992) · Journal of the American College of Nutrition · doi:10.1080/07315724.1992.12098245 · Cited by 625 · cited 5×
“In normal and ill subjects, BIA is correlated with total body water, and the variations of both are also correlated (11).”
BackgroundMethodInfluentialBioelectric impedance phase angle and body composition
Baumgartner, R., Chumlea, W., & Roche, A. (1988) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/48.1.16 · Cited by 477 · cited 4×
“Second, for measuring the leg impedance, some investigators (1, 4, 5) placed their sensing electrode at the anterior midline of the thigh, in the same plane as the gluteal crease, whereas others (8) placed the pelvic electrode at the same location as in the present study.”
BackgroundMethodResultInfluentialUse of dual-energy x-ray absorptiometry in body-composition studies: not yet a “gold standard”
Roubenoff, R., Kehayias, J., Dawson-Hughes, B., & Heymsfield, S. (1993) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/58.5.589 · Cited by 369 · cited 1×
“However, as any in vivo body composition assessment, it has nevertheless some limitations (24).”
BackgroundSegal, K., Burastero, S., Chun, A., Coronel, P., Pierson, R., & Wang, J. (1991) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/54.1.26 · Cited by 311 · cited 1×
“, FFM) of the analyzed segment, whereas lowfrequency currents flow mainly through the extracellular volume (27).”
Background
Cited by
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
“10(waist area)) in square meter [73,74], where segment area = c 2 /4π and (c) is the circumference in meter of the arm, waist and calf, respectively; L = 1.”
BackgroundMethodMetabolic equivalent: one size does not fit all
Byrne, N. M., Hills, A. P., Hunter, G. R., Weinsier, R. L., & Schutz, Y. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00023.2004 · Cited by 527
Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Bera, T. K. (2014) · Journal of Medical Engineering · doi:10.1155/2014/381251 · Cited by 407
Late evening snack: exploiting a period of anabolic opportunity in cirrhosis
Tsien, C. D., McCullough, A. J., & Dasarathy, S. (2012) · Journal of Gastroenterology and Hepatology · doi:10.1111/j.1440-1746.2011.06951.x · Cited by 252
Lean Body Mass Is a Major Determinant of Levothyroxine Dosage in the Treatment of Thyroid Diseases
Santini, F., Pinchera, A., Marsili, A., Ceccarini, G., Castagna, M. G., Valeriano, R., Giannetti, M., Taddei, D., Centoni, R., Scartabelli, G., et al. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2004-1306 · Cited by 226
Klaver, M., de Blok, C. J. M., Wiepjes, C. M., Nota, N. M., Dekker, M. J. H. J., de Mutsert, R., Schreiner, T., Fisher, A. D., T’Sjoen, G., & den Heijer, M. (2018) · European Journal of Endocrinology · doi:10.1530/eje-17-0496 · Cited by 198
“Age categories for reference values; Women: (16) category 20-29 years old, (17) median 31 years old (range 18-62), (18) mean 20.”
BackgroundDevelopment of methods for body composition studies
Mattsson, S., & Thomas, B. J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r13 · Cited by 193
“In an attempt to overcome the concerns with the assumption of the body as approximated by a single cylinder, some authors have used a ‘segmental’ approach for the determination of the conducting volume (Organ et al 1994, Bracco et al 1996).”
MethodComparison of Three Bioelectrical Impedance Methods with DXA in Overweight and Obese Men
Pateyjohns, I. R., Brinkworth, G. D., Buckley, J. D., Noakes, M., & Clifton, P. M. (2006) · Obesity · doi:10.1038/oby.2006.241 · Cited by 187
“The extremities are relatively long with a small diameter, resulting in higher impedance values, whereas the trunk contains approximately one-half the conductive mass but contributes minimally to total body impedance (27).”
BackgroundFaria, S. L., Faria, O. P., Cardeal, M. D. A., & Ito, M. K. (2014) · Obesity Surgery · doi:10.1007/s11695-014-1190-5 · Cited by 170
“There is also a change in intra- and extracellular water in these patients, which may also interfere with the results [8].”
ResultHamilton, B., Whiteley, R., Farooq, A., & Chalabi, H. (2014) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2013.03.006 · Cited by 100
Becroft, L., Ooi, G., Forsyth, A., King, S., & Tierney, A. (2019) · International Journal of Obesity · doi:10.1038/s41366-018-0285-9 · Cited by 51
Mally, K., Trentmann, J., Heller, M., & Dittmar, M. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1795-x · Cited by 49
Liao, Y.-S., Li, H.-C., Lu, H.-K., Lai, C.-L., Wang, Y.-S., & Hsieh, K.-C. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17072595 · Cited by 48
“for the estimation of BMC at segmental body level because calculation of segmental body composition involves more variables and assumptions [34].”
BackgroundGuiraudou, M., Maimoun, L., Dumas, J.-M., Julia, M., Raingeard, I., & Brun, J.-F. (2015) · Science & Sports · doi:10.1016/j.scispo.2015.08.002 · Cited by 17
Metadata
- Authors
- Bracco, D., Thiébaud, D., Chioléro, R. L., Landry, M., Burckhardt, P., & Schutz, Y.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1996-12-01
- Volume
- 81
- Issue
- 6
- Pages
- 2580-2587
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2144828800
- Cited by
- 159
- References
- 28
- FWCI
- 0.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.