Improving energy expenditure estimation by using a triaxial accelerometer
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Chen, Kong Y., and Ming Sun. Improving energy expenditure estimation by using a triaxial accelerometer. J. Appl. Physiol. 83(6): 2112–2122, 1997.—In our study of 125 subjects (53 men and 72 women) for two 24-h periods, we validated energy expenditure (EE), estimated by a triaxial accelerometer (Tritrac-R3D), by using a whole-room indirect calorimeter under close-to-normal living conditions. The estimated EE was correlated with the measured total EE for the 2 days ( r = 0.925 and r = 0.855; P < 0.001) and in minute-by-minute EE ( P < 0.01). Resting EE formulated by the Tritrac was found to be similar to the measured values [standard errors of estimation (SEE) = 0.112 W/kg; P = 0.822]. The Tritrac significantly underestimated total EE, EE for physical activities, EE of sedentary and light-intensity activities, and EE for exercise such as stepping (all P < 0.001). We developed a linear and a nonlinear model to predict EE by using the acceleration components from the Tritrac. Predicted EE was significantly improved with both models in estimating total EE, total EE for physical activities, EE in low-intensity activities, minute-by-minute averaged relative difference, and minute-by-minute SEE (all P < 0.05). Furthermore, with our generalized models and by using subjects’ physical characteristics and body acceleration, EE can be estimated with higher accuracy (averaged SEE = 0.418 W/kg) than with the Tritrac model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Activity, All-Cause Mortality, and Longevity of College Alumni
Paffenbarger, R. S., Hyde, R., Wing, A. L., & Hsieh, C.-C. (1986) · New England Journal of Medicine · doi:10.1056/nejm198603063141003 · Cited by 2,742 · cited 1×
“WITH THE ESTABLISHMENT of a negative correlation between energy costs of physical activities and incidence of morbidity/mortality for some chronic diseases, such as coronary heart disease, hypertension, and diabetes (2, 20), the quantification of energy expenditure (EE) and daily physical activities has gained conside…”
BackgroundPhysical Fitness and All-Cause Mortality: A Prospective Study of Healthy Men and Women
Blair, S. N. (1989) · JAMA · doi:10.1001/jama.1989.03430170057028 · Cited by 2,658
Cited by
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996
Self-citationMathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/2/r01 · Cited by 829
Najafi, B., Aminian, K., Paraschiv-Ionescu, A., Loew, F., Bula, C. J., & Robert, P. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.812189 · Cited by 762
Calibration of Accelerometer Output for Adults
MATTHEW, C. E. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185659.11982.3d · Cited by 659
Direct measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Martínez-González, M. A., López-Fontana, C., Varo, J. J., Sánchez-Villegas, A., & Martinez, J. A. (2005) · Public Health Nutrition · doi:10.1079/phn2005745 · Cited by 586
Kumahara, H., Schutz, Y., Ayabe, M., Yoshioka, M., Yoshitake, Y., Shindo, M., Ishii, K., & Tanaka, H. (2004) · British Journal of Nutrition · doi:10.1079/bjn20031033 · Cited by 534
Challenges and Opportunities for Measuring Physical Activity in Sedentary Adults
Tudor-Locke, C. E., & Myers, A. M. (2001) · Sports Medicine · doi:10.2165/00007256-200131020-00002 · Cited by 519
Ohkawara, K., Oshima, Y., Hikihara, Y., Ishikawa-Takata, K., Tabata, I., & Tanaka, S. (2011) · British Journal of Nutrition · doi:10.1017/s0007114510005441 · Cited by 458
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“7%) [343, 364] (Additional file 1: figure S3d).”
Actigraph GT3X: Validation and Determination of Physical Activity Intensity Cut Points
Santos-Lozano, A., Santín-Medeiros, F., Cardon, G., Torres-Luque, G., Bailón, R., Bergmeir, C., Ruiz, J., Lucia, A., & Garatachea, N. (2013) · International Journal of Sports Medicine · doi:10.1055/s-0033-1337945 · Cited by 383
Assessing Physical Activity Using Wearable Monitors: Measures of Physical Activity
BUTTE, N. F., EKELUND, U., & WESTERTERP, K. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399c0e · Cited by 359
Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure
FRUIN, M. L., & RANKIN, J. W. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000128144.91337.38 · Cited by 342
Principles of Design and Analyses for the Calibration of Accelerometry-Based Activity Monitors
WELK, G. J. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185660.38335.de · Cited by 339
Murphy, S. L. (2009) · Preventive Medicine · doi:10.1016/j.ypmed.2008.12.001 · Cited by 326
Ainslie, P. N., Reilly, T., & Westerterp, K. R. (2003) · Sports Medicine · doi:10.2165/00007256-200333090-00004 · Cited by 309
Brage, S., Ekelund, U., Brage, N., Hennings, M. A., Froberg, K., Franks, P. W., & Wareham, N. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00092.2006 · Cited by 303
Physical activity assessment with accelerometers
Westerterp, K. (1999) · International Journal of Obesity · doi:10.1038/sj.ijo.0800883 · Cited by 288
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Detection of daily physical activities using a triaxial accelerometer
Mathie, M. J., Coster, A. C. F., Lovell, N. H., & Celler, B. G. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348434 · Cited by 237
LEMMER, J. T., IVEY, F. M., RYAN, A. S., MARTEL, G. F., HURLBUT, D. E., METTER, J. E., FOZARD, J. L., FLEG, J. L., & HURLEY, B. F. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200104000-00005 · Cited by 203
“TEE estimated by the Tritrac has been shown to have very high positive correlations with oxygen consumption during level, ambulatory walking (29), and with TEE measured in a whole room calorimeter (7).”
MethodBonomi, A. G., Plasqui, G., Goris, A. H. C., & Westerterp, K. R. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00150.2009 · Cited by 196
“Additionally, nonlinear models such as artificial neural networks have been applied to the raw acceleration of the body to improve the prediction accuracy of energy expenditure (6, 23).”
MethodValidation of the GT3X ActiGraph in children and comparison with the GT1M ActiGraph
Hänggi, J. M., Phillips, L. R. S., & Rowlands, A. V. (2013) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2012.05.012 · Cited by 196
Validity of Physical Activity Intensity Predictions by ActiGraph, Actical, and RT3 Accelerometers
Rothney, M. P., Schaefer, E. V., Neumann, M. M., Choi, L., & Chen, K. Y. (2008) · Obesity · doi:10.1038/oby.2008.279 · Cited by 175
“Height and weight were measured the morning the subject entered the room calorimeter. table 1 characteristics of study participants All subjects (n = 85) Men (n = 37) Women (n = 48) Age (years) 39.3 ± 12.9 38.5 ± 13.1 39.9 ± 12.9 (20–69) (20–69) (20–67) Height (m) 1.70 ± 0.09 1.78 ± 0.06 1.64 ± 0.06 (1.52–1.91) (1.67–…”
BackgroundInfluentialSelf-citationPhysical activity in daily life in patients with chronic low back pain
Verbunt, J. A., Westerterp, K. R., van der Heijden, G. J., Seelen, H. A., Vlaeyen, J. W., & Knottnerus, J. A. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.23182 · Cited by 162
Brage, S., Westgate, K., Franks, P. W., Stegle, O., Wright, A., Ekelund, U., & Wareham, N. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137206 · Cited by 151
“Only one group-calibrated ACC-PAEE equation was evaluated [13], as it has previously been shown that individual calibration of this relationship provides little or no improvement in estimation accuracy for daily living activities [18,30–32].”
MethodActivity Monitoring and Energy Expenditure in COPD Patients: A Validation Study
Patel, S. A., Benzo, R. P., Slivka, W. A., & Sciurba, F. C. (2007) · COPD: Journal of Chronic Obstructive Pulmonary Disease · doi:10.1080/15412550701246658 · Cited by 144
Wearable Inertial Sensors and Their Applications
Tamura, T. (2014) · Wearable Sensors · doi:10.1016/b978-0-12-418662-0.00024-6 · Cited by 19
Metadata
- Authors
- Chen, K. Y., & Sun, M.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1997-12-01
- Volume
- 83
- Issue
- 6
- Pages
- 2112-2122
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2114006232
- Cited by
- 211
- References
- 2
- FWCI
- 0.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.