Analytic assessment of the various bioimpedance methods used to estimate body water
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Knowledge of patient fluid distribution would be useful clinically. Both single-frequency (SF) and impedance modeling approaches are proposed. The high intercorrelation between body water compartments makes determining the best approach difficult. This study was conducted to evaluate the merits of an SF approach. Mathematical simulation was performed to determine the effect of tissue change on resistance and reactance. Dilution results were reanalyzed, and resistance and parallel reactance were used to predict the intracellular water for two groups. Results indicated that the amount of intracellular and extracellular water conduction at any SF can vary with tissue change, and reactance at any SF is affected by all tissue parameters. Modeling provided a good prediction of dilution intracellular and extracellular water, but an SF method did not. Intracellular, extracellular, and total body water were equally predicted at all frequencies by SF resistance and parallel reactance. Extracellular and intracellular water are best measured through modeling, because only at the zero and infinite frequencies are the results sensitive only to extracellular and intracellular water. At all other frequencies there are other effects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Total body water measurement in humans with 18O and 2H labeled water
Schoeller, D. A., van Santen, E., Peterson, D. W., Dietz, W., Jaspan, J., & Klein, P. D. (1980) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/33.12.2686 · Cited by 666
Kotler, D., Burastero, S., Wang, J., & Pierson, R. (1996) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/64.3.489s · Cited by 472 · cited 28×
“In this recent study the prediction of TBK by XP was also discussed, but BCM was interchanged with TBK throughout the article (14).”
BackgroundMethodInfluentialForbes, G. B. (1987) · doi:10.1007/978-1-4612-4654-1 · Cited by 431
Segal, K., Burastero, S., Chun, A., Coronel, P., Pierson, R., & Wang, J. (1991) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/54.1.26 · Cited by 311 · cited 3×
“reactance and ECW (32); thus, one datum (i.”
BackgroundNutritional assessment with bioelectrical impedance analysis in maintenance hemodialysis patients.
Chertow, G. M., Lowrie, E. G., Wilmore, D. W., Gonzalez, J., Lew, N. L., Ling, J., Leboff, M. S., Gottlieb, M. N., Huang, W., & Zebrowski, B. (1995) · Journal of the American Society of Nephrology · doi:10.1681/asn.v6175 · Cited by 257
Cited by
Human Body Composition: In Vivo Methods
Ellis, K. J. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.2.649 · Cited by 825
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712
“Estimation of TBW, ECF and ICF using BIS techniques can be performed using either an equation modules approach [10,31–33] or an analytically derived equations approach [27].”
MethodJaffrin, M. Y., & Morel, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.06.009 · Cited by 490
Marra, M., Sammarco, R., De Lorenzo, A., Iellamo, F., Siervo, M., Pietrobelli, A., Donini, L. M., Santarpia, L., Cataldi, M., Pasanisi, F., et al. (2019) · Contrast Media & Molecular Imaging · doi:10.1155/2019/3548284 · Cited by 401
(2006) · Routledge eBooks · doi:10.4324/9780203970157 · Cited by 258
Metadata
- Authors
- Matthie, J., Zarowitz, B., De Lorenzo, A., Andreoli, A., Katzarski, K., Pan, G., & Withers, P.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 1998-05-01
- Volume
- 84
- Issue
- 5
- Pages
- 1801-1816
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2145619937
- Cited by
- 134
- References
- 6
- FWCI
- 4.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Analytic assessment of the various bioimpedance methods used to estimate body water. https://app.cochat.ai/papers/10.1152/jappl.1998.84.5.1801
- The paper
- Matthie, J., Zarowitz, B., De Lorenzo, A., Andreoli, A., Katzarski, K., Pan, G., & Withers, P. (1998). Analytic assessment of the various bioimpedance methods used to estimate body water. Journal of Applied Physiology. https://doi.org/10.1152/jappl.1998.84.5.1801
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.