CoChat

Second generation mixture theory equation for estimating intracellular water using bioimpedance spectroscopy

Matthie, James R. · 2005 · Journal of Applied Physiology
Cited by 94

The DOI matches its Crossref record.

Abstract

LETTERS TO THE EDITORSecond generation mixture theory equation for estimating intracellular water using bioimpedance spectroscopyJames R. MatthieJames R. MatthiePublished Online:01 Aug 2005https://doi.org/10.1152/japplphysiol.00145.2005MoreSectionsPDF (45 KB)Download PDF ToolsExport citationAdd to favoritesGet permissionsTrack citations To the Editor: In 1990, Xitron introduced a multifrequency impedance device designed for in vivo body composition studies (10). Soon after, Xitron provided software with the device for computing the Cole model of biological tissue (1) and predicting intracellular water (ICW) and extracellular water (ECW) using equations Xitron derived from mixture theory (8, 13). Before introduction of the software, an improvement in the ICW equation was developed and provided internally by Xitron.The Xitron ECW and first generation ICW volume equations have been published both by Xitron and others (2, 5, 7, 9, 10). On numerous occasions Xitron has indicated that there was a slight difference between Xitron's published ICW equation and that used (2, 4). Because the actual equation has not been published, it is possible that some investigators may have or still are using the first ICW equation (7, 9). In an unpublished analysis, Xitron found that the second ICW equation produces more accurate results then the first. A study published in this journal in 2000 found that Xitron's second ICW equation predicts ICW change more accurately than other published equations (4). Nonetheless, studies are underway to validate the differences between the two equations, and other investigators may wish to do the same. It is also important to make public Xitron's second generation ICW equation so that further progress can be made in the development of theoretically based volume equations (3, 11, 12).RATIONALE FOR NEW ICW EQUATIONThe first Xitron equations assumed that the relationship between impedance at low frequency and ECW volume was a simple nonlinear mixture effect involving two spaces (conductor and nonconductor). At high frequency we assumed that there were three spaces (ECW, ICW, and nonconductor) and that the relationship between total body water (TBW) resistivity and ECW-ICW ratio was linear.Internal analysis revealed that the effect of an ECW-ICW ratio change on TBW resistivity is highly nonlinear because the ICW has a 3–4 to 1 greater resistivity than ECW (1, 6). The ECW equation has not changed. The second generation ICW equation presented below assumes two vs. one mixture effect: one at low frequency to account for the relationship between ECW and the reminder of material in the body (considered nonconductor), and one at high frequency to account for the relationship between ECW, ICW, and nonconductor. Using the same analysis as used for the ECW volume equation described in the appendix, with the same assumptions: (1) where Wt is body weight (kg); Ht is height (cm); KB is a factor correcting for a whole body measurement between wrist and ankle, relating the relative proportions of the leg, arm, trunk, and height; VTBW is the TBW volume (liters) (ECW + ICW), ρTBW is the resistivity of the overall fluid (Ω·cm), and RINF is the resistance of the overall fluid (Ω) (i.e., infinite frequency resistance).Dividing Eq. 1 by the published ECW equation yields (2) where RE is the value from the model fitting (Ω), where VICW is the ICW volume (liters).RI is a model fitting term (Ω), and, from the parallel resistances formed by RE and RI, Thus (3) Simplifying Eq. 3, (4) or (5) From the theory of Hanai, for a mixture of two conductive fluids (6) where CICW = VICW/VTBW, i.e., the volumetric ratio concentration of ICW in the overall fluid, σTBW, σECW, and σICW are the conductivities of the overall fluid, ECW, and ICW, respectively.Reexpressing this equation using resistivities and the concentration of ECW (rather than ICW) yields (7) where ρICW is the resistivity of the ICW (Ω·cm).Expanding yields (8) Combining yields (9) But, as shown in Eq. 4, (10) i.e., (11) Combining Eqs. 9 and 11 yields (12) which after simplification becomes (13) or (14) Thus, from the measured circuit model resistances and the computed ECW volume, it is possible to calculate the ICW volume using Eqs. 5 and 14.APPENDIXAs reported, our equation for ECW is as follows: where VECW is the predicted total ECW volume (liters). ρECW is the resistivity of ECW (Ω·cm); and DB is body density (kg/cc).For a full description of the assumptions and computation of KB and values used for KB, ρECW, ρICW, and DB, please refer to the paper by De Lorenzo (2).REFERENCES1 Cole KS. Permeability and impermeability of cell membranes for ions. Cold Spring Harb Symp Quant Biol 8: 110–122, 1940.Crossref | Google Scholar2 De Lorenzo A, Andreoli A, Matthie J, and Withers P. Predicting body cell mass with bioimpedance by using theoretical methods: a technological review [published erratum appears in J Appl Physiol 83(6): following table of contents, 1997]. J Appl Physio

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1152/japplphysiol.00145.2005

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Matthie, J. R.
Venue
Journal of Applied Physiology
Published
2005-08
Volume
99
Issue
2
Pages
780-781
ISSN
  • 0161-7567 (ISSN-L)
  • 8750-7587
  • 1522-1601
OpenAlex
W2131392195
Cited by
94
References
0
FWCI
2.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.