The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
A machine-learning approach for computation of fractional flow reserve from coronary computed tomography
Open accessAbstract
Fractional flow reserve (FFR) is a functional index quantifying the severity of coronary artery lesions and is clinically obtained using an invasive, catheter-based measurement. Recently, physics-based models have shown great promise in being able to noninvasively estimate FFR from patient-specific anatomical information, e.g., obtained from computed tomography scans of the heart and the coronary arteries. However, these models have high computational demand, limiting their clinical adoption. In this paper, we present a machine-learning-based model for predicting FFR as an alternative to physics-based approaches. The model is trained on a large database of synthetically generated coronary anatomies, where the target values are computed using the physics-based model. The trained model predicts FFR at each point along the centerline of the coronary tree, and its performance was assessed by comparing the predictions against physics-based computations and against invasively measured FFR for 87 patients and 125 lesions in total. Correlation between machine-learning and physics-based predictions was excellent (0.9994, P < 0.001), and no systematic bias was found in Bland-Altman analysis: mean difference was -0.00081 ± 0.0039. Invasive FFR ≤ 0.80 was found in 38 lesions out of 125 and was predicted by the machine-learning algorithm with a sensitivity of 81.6%, a specificity of 83.9%, and an accuracy of 83.2%. The correlation was 0.729 (P < 0.001). Compared with the physics-based computation, average execution time was reduced by more than 80 times, leading to near real-time assessment of FFR. Average execution time went down from 196.3 ± 78.5 s for the CFD model to ∼2.4 ± 0.44 s for the machine-learning model on a workstation with 3.4-GHz Intel i7 8-core processor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Book Review: Pattern Recognition and Machine Learning
Nasrabadi, N. M. (2007) · Journal of Electronic Imaging · doi:10.1117/1.2819119 · Cited by 22,066
Learning Deep Architectures for AI
Bengio, Y. (2009) · Foundations and Trends® in Machine Learning · doi:10.1561/2200000006 · Cited by 9,239
Global status report on noncommunicable diseases 2010.
Alwan, A. (2011) · Cited by 8,494
Learning Deep Architectures for AI
Bengio, Y. (2009) · now publishers, Inc. eBooks · doi:10.1561/9781601982957 · Cited by 4,941
Fractional Flow Reserve versus Angiography for Guiding Percutaneous Coronary Intervention
Tonino, P. A. L., De Bruyne, B., Pijls, N. H. J., Siebert, U., Ikeno, F., van `t Veer, M., Klauss, V., Manoharan, G., Engstrøm, T., Oldroyd, K. G., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0807611 · Cited by 4,260
Developed with the special contribution of the European Association for Percutaneous Cardiovascular Interventions (EAPCI), Authors/Task Force Members, Wijns, W., Kolh, P., Danchin, N., Di Mario, C., Falk, V., Folliguet, T., Garg, S., Huber, K., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq277 · Cited by 3,184
Fractional Flow Reserve–Guided PCI versus Medical Therapy in Stable Coronary Disease
De Bruyne, B., Pijls, N. H. J., Kalesan, B., Barbato, E., Tonino, P. A. L., Piroth, Z., Jagic, N., Möbius-Winkler, S., Rioufol, G., Witt, N., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1205361 · Cited by 2,772
Fihn, S. D., Gardin, J. M., Abrams, J., Berra, K., Blankenship, J. C., Dallas, A. P., Douglas, P. S., Foody, J. M., Gerber, T. C., Hinderliter, A. L., et al. (2012) · Circulation · doi:10.1161/cir.0b013e3182776f83 · Cited by 2,410
Measurement of Fractional Flow Reserve to Assess the Functional Severity of Coronary-Artery Stenoses
Pijls, N. H. J., de Bruyne, B., Peels, K., van der Voort, P. H., Bonnier, H. J. R. M., Bartunek, J., & Koolen, J. J. (1996) · New England Journal of Medicine · doi:10.1056/nejm199606273342604 · Cited by 2,321
The Physiological Principle of Minimum Work: I. The Vascular System and the Cost of Blood Volume
Murray, C. D. (1926) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.12.3.207 · Cited by 2,087
Nørgaard, B. L., Leipsic, J., Gaur, S., Seneviratne, S., Ko, B. S., Ito, H., Jensen, J. M., Mauri, L., De Bruyne, B., Bezerra, H., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2013.11.043 · Cited by 1,498
Koo, B.-K., Erglis, A., Doh, J.-H., Daniels, D. V., Jegere, S., Kim, H.-S., Dunning, A., DeFrance, T., Lansky, A., Leipsic, J., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.066 · Cited by 1,282
Taylor, C. A., Fonte, T. A., & Min, J. K. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.11.083 · Cited by 1,208
Diagnostic Accuracy of Fractional Flow Reserve From Anatomic CT Angiography
Min, J. K., Leipsic, J., Pencina, M. J., Berman, D. S., Koo, B.-K., van Mieghem, C., Erglis, A., Lin, F. Y., Dunning, A. M., Apruzzese, P., et al. (2012) · JAMA · doi:10.1001/2012.jama.11274 · Cited by 1,162
Effects of adenosine on human coronary arterial circulation.
Wilson, R. F., Wyche, K., Christensen, B. V., Zimmer, S., & Laxson, D. D. (1990) · Circulation · doi:10.1161/01.cir.82.5.1595 · Cited by 906
Olufsen, M. S., Peskin, C. S., Kim, W. Y., Pedersen, E. M., Nadim, A., & Larsen, J. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1326031 · Cited by 862
Samady, H., Eshtehardi, P., McDaniel, M. C., Suo, J., Dhawan, S. S., Maynard, C., Timmins, L. H., Quyyumi, A. A., & Giddens, D. P. (2011) · Circulation · doi:10.1161/circulationaha.111.021824 · Cited by 751
Comprehensive Assessment of Coronary Artery Stenoses
Meijboom, W. B., Van Mieghem, C. A. G., van Pelt, N., Weustink, A., Pugliese, F., Mollet, N. R., Boersma, E., Regar, E., van Geuns, R. J., de Jaegere, P. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.05.024 · Cited by 637
Zheng, Y., Barbu, A., Georgescu, B., Scheuering, M., & Comaniciu, D. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2004421 · Cited by 546
Self-citationTu, S., Barbato, E., Köszegi, Z., Yang, J., Sun, Z., Holm, N. R., Tar, B., Li, Y., Rusinaru, D., Wijns, W., et al. (2014) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2014.03.004 · Cited by 361
Evolving concepts of angiogram: fractional flow reserve discordances in 4000 coronary stenoses
Toth, G., Hamilos, M., Pyxaras, S., Mangiacapra, F., Nelis, O., De Vroey, F., Di Serafino, L., Muller, O., Van Mieghem, C., Wyffels, E., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu094 · Cited by 329
Morris, P. D., Ryan, D., Morton, A. C., Lycett, R., Lawford, P. V., Hose, D. R., & Gunn, J. P. (2013) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2012.08.024 · Cited by 270
Coenen, A., Lubbers, M. M., Kurata, A., Kono, A., Dedic, A., Chelu, R. G., Dijkshoorn, M. L., Gijsen, F. J., Ouhlous, M., van Geuns, R.-J. M., et al. (2015) · Radiology · doi:10.1148/radiol.14140992 · Cited by 264
Scaling laws of vascular trees: of form and function
Kassab, G. S. (2006) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00579.2005 · Cited by 221
Renker, M., Schoepf, U. J., Wang, R., Meinel, F. G., Rier, J. D., Bayer, R. R., Möllmann, H., Hamm, C. W., Steinberg, D. H., & Baumann, S. (2014) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2014.07.064 · Cited by 191
Scaling of myocardial mass to flow and morphometry of coronary arteries
Choy, J. S., & Kassab, G. S. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01261.2007 · Cited by 172
The pattern of coronary arteriolar bifurcations and the uniform shear hypothesis
Kassab, G. S., & Fung, Y. C. (1995) · Annals of Biomedical Engineering · doi:10.1007/bf02368296 · Cited by 127
The Coronary Angiogram and Its Seminal Contributions to Cardiovascular Medicine Over Five Decades
Ryan, T. J. (2002) · Circulation · doi:10.1161/01.cir.0000024109.12658.d4 · Cited by 101
Hachamovitch, R., & Carli, M. F. D. (2008) · Circulation · doi:10.1161/circulationaha.107.714006 · Cited by 93
Tröbs, M., Achenbach, S. S., Röther, J., Redel, T., Scheuering, M., Winneberger, D., Klingenbeck, K., Lucian Mihai, I. T. U., Passerini, T., Kamen, A., et al. (2015) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2015.10.008 · Cited by 84
Self-citationTøndel, K., Indahl, U. G., Gjuvsland, A. B., Vik, J. O., Hunter, P. J., Omholt, S. W., & Martens, H. A. (2011) · BMC Systems Biology · doi:10.1186/1752-0509-5-90 · Cited by 48
Deng, S., Jing, X., Wang, J., Huang, C., Xia, S., Du, J., Liu, Y.-J., & She, Q. (2015) · International Journal of Cardiology · doi:10.1016/j.ijcard.2015.03.025 · Cited by 28
Ralovich, K., Lucian Mihai, I. T. U., Vitanovski, D., Sharma, P. K., Ionasec, R. I., Mihalef, V., Krawtschuk, W., Zheng, Y., Everett, A. D., Pongiglione, G., et al. (2015) · Medical Physics · doi:10.1118/1.4914856 · Cited by 21
Self-citationZheng, Y., & Comaniciu, D. (2014) · CERN Document Server (European Organization for Nuclear Research) · doi:10.1007/978-1-4939-0600-0 · Cited by 8
Self-citation
Cited by
Pesapane, F., Codari, M., & Sardanelli, F. (2018) · European Radiology Experimental · doi:10.1186/s41747-018-0061-6 · Cited by 833
Artificial Intelligence in Cardiovascular Imaging
Dey, D., Slomka, P. J., Leeson, P., Comaniciu, D., Shrestha, S., Sengupta, P. P., & Marwick, T. H. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.12.054 · Cited by 680
Self-citationAl’Aref, S. J., Anchouche, K., Singh, G., Slomka, P. J., Kolli, K. K., Kumar, A., Pandey, M., Maliakal, G., van Rosendael, A. R., Beecy, A. N., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy404 · Cited by 534
Liang, L., Liu, M., Martin, C., & Sun, W. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0844 · Cited by 502
Coenen, A., Kim, Y.-H., Kruk, M., Tesche, C., De Geer, J., Kurata, A., Lubbers, M. L., Daemen, J., Itu, L., Rapaka, S., et al. (2018) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.117.007217 · Cited by 397
Self-citation
Metadata
- Authors
- Itu, L., Rapaka, S., Passerini, T., Georgescu, B., Schwemmer, C., Schoebinger, M., Flohr, T., Sharma, P., & Comaniciu, D.
- Venue
- Journal of Applied Physiology
- Publisher
- American Physiological Society
- Published
- 2016-04-14
- Volume
- 121
- Issue
- 1
- Pages
- 42-52
- ISSN
- 0161-7567 (ISSN-L)
- 8750-7587
- 1522-1601
- OpenAlex
- W2335916523
- Cited by
- 406
- References
- 34
- FWCI
- 29.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.